Search NASA⌕ Search

SEARCH · Search NASA

Results for “interconnect”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Interpreting Forced Oscillation Notifications from ESAMS: General Guidance for Reliability Coordinators

The Eastern Interconnection Situational Awareness Monitoring System (ESAMS) project demonstrated the feasibility of aggregating synchrophasor measurements from across an interconnection, analyzing them, and providing real-time wide-area situational awareness to system operators who may have excellent visibility within their footprint but lack an interconnection-wide view. An application within ESAMS that has garnered industry interest involves detecting forced oscillations visible across multiple areas, identifying the region where the oscillation originated from, quantifying the uncertainty in source localization results, and notifying users in real-time if the detected oscillation amplitudes cross a specified threshold. It is expected that system operators will utilize their internal SCADA/EMS/synchrophasor systems in conjunction with information provided by ESAMS to take effective mitigation actions if forced oscillation notifications are received. This report provides some general guidance on how the ESAMS information can be used for source localization and coordination among multiple reliability coordinators; and also identifies potential enhancements to ESAMS notifications for improved interpretability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

American-Made Solar Prize: Edgeli Enables DER Integration (CRADA 615) (Final Report)

The purpose of this project was to demonstrate how granular time series data and automated data transformation, and impact assessment tools could speed interconnection approvals for distributed energy resource projects of various types and sizes. Types included community solar, rooftop solar, and EV charging projects. Using software routines to automate the transformation of data (e.g. GIS) to a network database and power flow model then applying scenarios to create hourly (8760) hosting capacity values and voltage and thermal impacts for specific projects, we were able to demonstrate the feasibility of quickly assembling and analyzing key utility data sets for interconnection purposes. The outcomes of this effort will become the foundation for future work that will enhance and encapsulate the software components developed as part of this project, into web services (e.g. APIs) that can be integrated into queue management systems and automate interconnection screening processes.

14 SOLAR ENERGY↗

Key Performance Indicators for Vehicle Grid Integration

Electric vehicle (EV) sales account for a rapidly growing portion of the light-duty vehicle market and a portion of medium and heavy-duty fleet vehicles. However, in many locations, charging stations will require costly utility grid upgrades with long lead times. Today, there are a few methods of smart charge management (SCM) which can reduce the costs and wait times for electric vehicle supply equipment (EVSE) interconnection approvals, as well as reduce impacts of the charging stations on the grid and on EV driver transportation costs. It is crucial for the EV charging industry to understand the vehicle grid integration (VGI) requirements for EVSE to prevent adverse impacts from EVSE interconnections and assure that charging loads and interconnections are affordable.

33 - ADVANCED PROPULSION SYSTEMS↗

A Methodology to Evaluate the Grid Reliability Impact of Oscillations Induced by Large Loads

The rapid growth of hyperscale AI data centers is bringing renewed attention to the reliability risk that sustained forced oscillations pose to bulk power systems, with cyclic computational workloads emerging as a new forcing source. Unlike the broadband, stochastic disturbances from traditional industrial loads such as arc furnaces, AI training and inference facilities can inject large active power swings concentrated at specific frequencies over extended durations - characteristics that existing grid planning practices do not account for. While the North American Electric Reliability Corporation (NERC) has recognized this gap and called for system-level studies of large load interconnections, no standardized methodology exists to screen, simulate, and quantify these risks at the planning stage. This report presents the Risk Assessment Tool for Large Load-induced Events (RATLLE), a Python-based, publicly available script suite developed at the Pacific Northwest National Laboratory to evaluate bulk power system reliability risks from data center-induced oscillations. RATLLE implements a three-module workflow: a screening module that identifies vulnerable interconnection locations and excitable system modes; a simulation module that models cyclic data center load behavior using a commercial positive sequence simulation platform; and an analysis module that computes risk metrics and generates interactive visualization dashboards. The risk metrics, formulated around simulation observables, map oscillation impacts to a three-stage severity scale spanning latent equipment fatigue through imminent cascading failure. The methodology is demonstrated on two Western Electricity Coordinating Council (WECC) system models: a publicly available 240-bus reduced representation and a detailed 2031 Heavy Winter planning case. Case studies illustrate that even modest 50 MW forced oscillations at resonant frequencies can produce wide-area power swings, N-1 security constraint violations, and cascading generator trips through protection actions - outcomes that would not occur under normal operating conditions without oscillations present. The results underscore the need for standardized oscillation impact assessment in large load interconnection studies and provide a reproducible, extensible framework for utilities to adopt or customize within their existing planning workflows.

Biswas, Shuchismita↗

Cooperative Transmission Expansion Planning Experiment Data and Results

GO WEST is an open-source power grid modeling framework for U.S. Western Interconnection, which allows users to tailor the model depending on their research study and science questions. It covers 28 balancing authorities (BA) and 12 states in U.S. Western Interconnection. GO WEST allows users to select different number of nodes and come up with a simplified network by utilizing 10,000 nodal topology of U.S. Western Interconnection created by Texas A&M University. Users can try and select different number of nodes, mathematical formulations (linear programming vs. mixed-integer linear programming), transmission line limit scaling factors, and hurdle rate scaling factors. GO WEST offers a unit commitment and economic dispatch (UC/ED) module to simulate grid operations on an hourly scale. In this sense, users can calibrate and validate their model versions by comparing model outputs to historical datasets. TEP is an open-source transmission capacity expansion model, built on GO WEST framework. It utilizes linear programming to optimize transmission capacity addition investment on existing lines within GO WEST framework. In this sense, TEP model only increases the thermal capacity of existing transmission lines and does not add new lines to the system, which leaves the topology preserved. TEP minimizes the total cost of the system which comprises the operational cost of satisfying electricity demand (i.e., generation cost), cost of loss of load (i.e., unserved energy), cost of power flow, and cost of new transmission capacity additions (i.e., investment cost). In order to use TEP model, users need to create scenarios with GO WEST framework. In this analysis, outputs from several models are used to create future inputs to GO WEST and TEP models, including GCAM-USA, TELL, CERF and reV. This dataset includes experiment inputs and outputs from three different transmission expansion scenarios (cooperative, intermediate, and individual) for 2019 and 2059. For 2019, a base scenario to illustrate the default (i.e., historical) power grid operations is also included. This study utilizes rcp45hotter_ssp3 scenario from a previous version of GCAM-USA simulations. Sources of the shapefiles in supplementary data are HIFLD Open and U.S. Energy Atlas. Please see the README file for a detailed description of the main and supplementary data.

Capacity Expansion Model↗

A 100,000 pulse height analyzer for use in High Energy Cosmic Ray Experiments (HECRE) on high altitude balloon flights

A description is given of a wide dynamic range pulse height analyzer system developed for use on High Energy Cosmic Ray Experiment (HECRE) Balloon Flights. A wide dynamic range of 100,000 is obtained by extending the range of a basic 1024 channel analyzer through the use of multiple ranges and range selection. The system described here contains four 100,000 pulse height analyzers. Each 100,000 pulse height analyzer consists of a group of cordwood welded modules mounted and interconnected on a printed circuit card. Four of these card assemblies, the required clock drive circuitry (discrete components mounted and interconnected on a separate card) and three input-output connectors are interconnected and mounted on the system board.

Cancro, C. A.↗

Design guidelines for advanced LSI microcircuit packaging using thick film multilayer technology

Ceramic multilayer circuitry results from the sequential build-up of two or more layers of pre-determined conductive interconnections separated by dielectric layers and fired at an elevated temperature to form a solidly fused structure. The resultant ceramic interconnect matrix is used as a base to mount active and passive devices and provide the necessary electrical interconnection to accomplish the desired electrical circuit. Many methods are known for developing multilevel conductor mechanisms such as multilayer printed circuits, welded wire matrices, flexible copper tape conductors, and thin and thick-film ceramic multilayers. Each method can be considered as a specialized field with each possessing its own particular set of benefits and problems. This design guide restricts itself to the art of design, fabrication and assembly of ceramic multilayer circuitry and the reliability of the end product.

Peckinpaugh, C. J.↗

ATM solar array in-flight performance analysis

The physical and electrical characteristics of the Apollo Telescope Mount (ATM) solar array are described and in-flight performance data are analyzed and compared with predicted results. Two solar cell module configurations were used. Type I module consists of 228 2 x 6 cm solar cells with two cells in parallel and 114 cells in series. Type II modules contain 684 2 x 2 cm cells with six cells in parallel and 114 cells in series. A different interconnection scheme was used for each type. Panels using type II modules with mesh interconnect system performed marginally better than those using type I module with loop interconnect system. The average degradation rate for the ATM array was 8.2% for a 271-day mission.

Thornton, J. P.↗

Properties criteria for components and materials used in lightweight solar arrays

The present work describes the characteristics and design criteria for components and materials used in lightweight substrate solar arrays. This includes descriptions of wraparound-electrode solar cells, cell covers, and cell interconnects. Cell cover systems briefly discussed are fused silica, cerium stabilized glass, microsheet, FEP (tape, heat laminated, and spray on), and ESB 7070 glass integral covers. The majority of solar arrays orbited have used either silver, Kovar, copper, or molybdenum as interconnect metals. Data are presented comparing the Young's modulus E, ultimate tensile strength, coefficient of expansion, thermal conductivity, and percent elongation of these and other interconnect candidate materials. Guidelines for the use of end tab wraparound cells are listed.

Lott, D. R.↗

Assembly of Photovoltaic Arrays

Vacuum holddown fixtures hold photovoltaic solar cells during assembly into array. Tab attachment fixture holds single cell and interconnecting tabs during heat-lamp soldering. Array-layout fixture has computer-scribed layout template and holds cells (with attached tabs) while being placed in position and transferred to array-interconnection fixture, which holds cells during final soldering step. Group of heat lamps on trolley passes slowly over interconnection fixture to heat cells to soldering temperature.

Coyle, P. J.↗

Beam forming network

The network, which is connected to a layer of 134 feed elements that transmit and receive microwaves, consists of a pair of circuit boards parallel to the feed element layer. One of the two boards has 87 dividers that each divide a signal to be transmitted into seven portions, and the other board has 134 combiners that each collect seven transmit signal portions and deliver the sum to one of the feed elements. A similar arrangement is used to handle received signals. The large number of interconnections are made by printed circuit conductors radiating from each of the numerous dividers and combiners, and by providing interconnection pins that interconnect the ends of pairs of conductors lying on the two boards. The printed circuit conductors extend in undulating paths that provide maximum separation of conductors to minimize crosstalk.

Cramer, P. W., Jr.↗

Amorphous silicon photovoltaic modules and test devices design, fabrication and testing

In July of 1984, Hughes and JPL initiated a contract for Hughes to design, fabricate and test 10 thin film Amorphous Silicon (a-Si) photovoltaic power modules. These modules were to be 1 ft x 4 ft in size. They were to be preceded by the delivery of 10 a-Si 4 in. square test devices. This effort is very timely since thin film PV development has progressed to the point where intermediate load power applications are on the horizon. It is important to know if current a-Si submodule design and manufacturing processes yield a product that is compatible with the packaging needed to meet a 20 to 30 year life span expectancy. The term submodule is assigned to an interconnected assembly of 28 a-Si cells deposited on a 1 foot square glass superstrate. These assemblies are equipped with electrical terminations, i.e., copper tabs at the four corners of the inverted submodules. It is these submodules that are to be interconnected and packaged into power modules, as opposed to the interconnected individual crystalline cells packaged into todays PV modules. A discussion of the fabrication methods and results follows.

Vanleeuwen, M.↗

Reliability models applicable to space telescope solar array assembly system

A complex system may consist of a number of subsystems with several components in series, parallel, or combination of both series and parallel. In order to predict how well the system will perform, it is necessary to know the reliabilities of the subsystems and the reliability of the whole system. The objective of the present study is to develop mathematical models of the reliability which are applicable to complex systems. The models are determined by assuming k failures out of n components in a subsystem. By taking k = 1 and k = n, these models reduce to parallel and series models; hence, the models can be specialized to parallel, series combination systems. The models are developed by assuming the failure rates of the components as functions of time and as such, can be applied to processes with or without aging effects. The reliability models are further specialized to Space Telescope Solar Arrray (STSA) System. The STSA consists of 20 identical solar panel assemblies (SPA's). The reliabilities of the SPA's are determined by the reliabilities of solar cell strings, interconnects, and diodes. The estimates of the reliability of the system for one to five years are calculated by using the reliability estimates of solar cells and interconnects given n ESA documents. Aging effects in relation to breaks in interconnects are discussed.

Patil, S. A.↗

Concurrent communication among multi-transceiver stations over shared media

In order to increase a local-area network's throughput beyond a single bus data rate without using dedicated switching nodes, multiple buses and multitransceiver stations are required. The design space of single-hop interconnections is explored among such stations. Interconnections are presented whose throughput can grow quadratically with the number of transmitters and receivers per station. These are referred to as selective broadcast interconnections (SBIs). The performance of various SBIs are studied. A spread-spectrum channel can accommodate several current successful transmission, and a single-transceiver node can thus utilize only a small fraction of the channel capacity. In order to allocate the appropriate fraction of capacity to a busy node, it is proposed to equip it with several transmitters and receivers, thereby turning it into a supernode. Several architectures and operation policies for supernodes are suggested and compared. It is shown that a supernode can significantly outperform a collection of independent conventional nodes with the same total numbers of transmitters and receivers. Packet-radio networks with half-duplex nodes, as well as networks with full-duplex nodes, are considered.

Birk, Yitzhak↗

On-board processing satellite network architecture and control study

The market for telecommunications services needs to be segmented into user classes having similar transmission requirements and hence similar network architectures. Use of the following transmission architecture was considered: satellite switched TDMA; TDMA up, TDM down; scanning (hopping) beam TDMA; FDMA up, TDM down; satellite switched MF/TDMA; and switching Hub earth stations with double hop transmission. A candidate network architecture will be selected that: comprises multiple access subnetworks optimized for each user; interconnects the subnetworks by means of a baseband processor; and optimizes the marriage of interconnection and access techniques. An overall network control architecture will be provided that will serve the needs of the baseband and satellite switched RF interconnected subnetworks. The results of the studies shall be used to identify elements of network architecture and control that require the greatest degree of technology development to realize an operational system. This will be specified in terms of: requirements of the enabling technology; difference from the current available technology; and estimate of the development requirements needed to achieve an operational system. The results obtained for each of these tasks are presented.

Campanella, S. Joseph↗

Thermoelectric power conversion in space

A radiatively-heated multicouple for use in the next generation of radioisotope thermoelectric generator (RTG) will employ 20 individual couples within a single cell, so that 40 n- and p-semiconductor legs will be interconnected in series. At the hot end of the RTG, the legs will be electrically interconnected using silicon molybdenum; on the cold side, the legs are interconnected by tungsten. The entire cell is then mechanically attached to a radiator, which conducts heat away and radiates it into space. Deep-space applications will use RTGs developed for vacuum operation; thermoelectric converter power systems using a unicouple configuration have flown on such missions as Pioneers 10 and 11, which used lead telluride thermoelectric converters, and Voyagers I and II, which used silicon germanium-based thermoelectrics.

Awaya, Henry I.↗

Threshold voltage for arcing on negatively biased solar arrays

The arcing that has been found to occur when negatively biased high-voltage solar arrays in LEO lie at a critical voltage with respect to the plasma environment is presently proposed to be due to a breakdown of gas emitted under electron bombardment from the solar cells' cover-glass. The elements of the model for this phenomenon include an electron current flow from the interconnect to a neighboring cover-glass, which desorbs neutral molecules under the electron bombardment. The neutral molecules form a gas over the interconnect, and this gas breaks down when the voltage over the interconnect is sufficiently high. Specific scaling predictions are made on the basis of the geometric structure and gas in question.

Hastings, Daniel E.↗

Rapid thermal cycling of new technology solar array blanket coupons

NASA Lewis Research Center is conducting thermal cycle testing of a new solar array blanket technologies. These technologies include test coupons for Space Station Freedom (SSF) and the advanced photovoltaic solar array (APSA). The objective of this testing is to demonstrate the durability or operational lifetime of the solar array interconnect design and blanket technology within a low earth orbit (LEO) or geosynchronous earth orbit (GEO) thermal cycling environment. Both the SSF and the APSA array survived all rapid thermal cycling with little or no degradation in peak performance. This testing includes an equivalent of 15 years in LEO for SSF test coupons and 30 years of GEO plus ten years of LEO for the APSA test coupon. It is concluded that both the parallel gap welding of the SSF interconnects and the soldering of the APSA interconnects are adequately designed to handle the thermal stresses of space environment temperature extremes.

Scheiman, David A.↗