Search NASA⌕ Search

SEARCH · Search NASA

Results for “linear array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Operation of the SUPARAMP at 33 GHz

A 9-mm degenerate parametric amplifier has been constructed using a linear series array of unbiased Josephson junctions as the active nonlinear element. A balanced diode mixer was used as a synchronous detector, with a single source serving both as the pump and as the mixer local oscillator. A stable net gain of 15 dB in an instantaneous bandwidth (FWHM) of 3.4 GHz has been achieved. A system noise temperature of 220 plus or minus 5 K (DSB) was measured with a SUPARAMP contribution of only 20 plus or minus 10 K. Output saturation has been observed. This complicates the interpretation of noise-temperature measurements and may render them upper limits. Comparison is made with the results of an earlier 3-cm SUPARAMP.

Chiao, R. Y.↗

Technology requirements for an orbital navigation/position finding system

The concept of an orbiting personal navigation system as a possible application for a large space structure is considered. The navigation system would have to be part of a large, integrated, multifunction Information Service Platform to justify its complexity and assured use by a large segment of the civilian population. The navigation configuration is a large cruciform which utilizes a linear phased array antenna design. The two antenna arms generate narrow, orthogonal beam patterns on the ground which are electrically scanned east to west and south to north. A passive ground receiver detecting the beam passage determines the user's position in earth longitude and latitude coordinates.

Lang, A. L., Jr.↗

Placement technique for semicustom digital LSI circuits

Small lots of special-purpose integrated circuits are fabricated from standard transitor arrays. Folded linear order of cells minimzes interconnection length and puts cell in juxtaposition. Cell-placement technique is carried out via computer program.

Carroll, B.↗

Near-infrared spectral imaging Michelson interferometer for astronomical applications

The design and operation of an imaging Michelson interferometer-spectrometer used for near-infrared (0.8 micron to 2.5 microns) spectral imaging are reported. The system employs a rapid scan interferometer modified for stable low resolution (250/cm) performance and a 42 element PbS linear detector array. A microcomputer system is described which provides data acquisition, coadding, and Fourier transformation for near real-time presentation of the spectra of all 42 scene elements. The electronic and mechanical designs are discussed and telescope performance data presented.

Wells, C. W.↗

Detection and recognition of simple spatial forms

A model of human visual sensitivity to spatial patterns is constructed. The model predicts the visibility and discriminability of arbitrary two-dimensional monochrome images. The image is analyzed by a large array of linear feature sensors, which differ in spatial frequency, phase, orientation, and position in the visual field. All sensors have one octave frequency bandwidths, and increase in size linearly with eccentricity. Sensor responses are processed by an ideal Bayesian classifier, subject to uncertainty. The performance of the model is compared to that of the human observer in detecting and discriminating some simple images.

Watson, A. B.↗

Fizeau wavemeter for pulsed laser wavelength measurement

A Fizeau wavelength meter optimized for use with pulsed laser sources has been developed and characterized which demonstrates a CW resolution better than 2 parts in 10 to the 7th and a pulsed resolution better than 1 part in 10 to the 6th. The static optical design is based on a Fizeau wedge interferometer, which together with spatial filtering and collimating optics is used to produce a pattern of parallel fringes which is imaged on a linear photodiode array and analyzed by a minicomputer. A series of CW and pulsed measurements of various narrowband laser sources are described, and particular difficulties involved in pulsed laser measurements with the wavemeter are examined.

Morris, M. B.↗

Advanced optical position sensors for magnetically suspended wind tunnel models

A major concern to aerodynamicists has been the corruption of wind tunnel test data by model support structures, such as stings or struts. A technique for magnetically suspending wind tunnel models was considered by Tournier and Laurenceau (1957) in order to overcome this problem. This technique is now implemented with the aid of a Large Magnetic Suspension and Balance System (LMSBS) and advanced position sensors for measuring model attitude and position within the test section. Two different optical position sensors are discussed, taking into account a device based on the use of linear CCD arrays, and a device utilizing area CID cameras. Current techniques in image processing have been employed to develop target tracking algorithms capable of subpixel resolution for the sensors. The algorithms are discussed in detail, and some preliminary test results are reported.

Lafleur, S.↗

Submillimeter-wave antennas on thin membranes

Submillimeter-wave antennas have been fabricated on 1-micron thick silicon-oxynitride membranes. This approach results in better patterns than previous lens-coupled antennas, and eliminates the dielectric loss associated with the substrate lens. Measurements on a wideband log-periodic antenna at 700 GHz, 370 GHz and 167 GHz show no sidelobes and 3-dB beamwidths between 40 and 60 deg. A linear imaging array has similar patterns at 700 GHz. Possible applications for membrane antennas include wideband superconducting tunnel-junction receivers for radio astronomy and imaging arrays for radiometry and plasma diagnostics.

Rebeiz, Gabriel M.↗

A five component electro-optical positioning system

The development of a five-component electrooptical positioning system for detecting the location of wind tunnel models within the test section is discussed. The system consists of three low power helium-neon lasers, five linear photodiode arrays, an assembly of optics that includes lenses and mirrors, and a signal conditioner. The system has been successfully installed and is currently in use at the 13-inch magnetic suspension and balance system (MSBS) at NASA Langley Research Center. Initially the system was developed as an auxiliary model position and attitude detecting system for that facility, but it has since been modified and interfaced with a PDP minicomputer to provide position feedback for the control loop.

Tcheng, Ping↗

Signal Restoration of Non-stationary Acoustic Signals in the Time Domain

Signal restoration is a method of transforming a nonstationary signal acquired by a ground based microphone to an equivalent stationary signal. The benefit of the signal restoration is a simplification of the flight test requirements because it could dispense with the need to acquire acoustic data with another aircraft flying in concert with the rotorcraft. The data quality is also generally improved because the contamination of the signal by the propeller and wind noise is not present. The restoration methodology can also be combined with other data acquisition methods, such as a multiple linear microphone array for further improvement of the test results. The methodology and software are presented for performing the signal restoration in the time domain. The method has no restrictions on flight path geometry or flight regimes. Only requirement is that the aircraft spatial position be known relative to the microphone location and synchronized with the acoustic data. The restoration process assumes that the moving source radiates a stationary signal, which is then transformed into a nonstationary signal by various modulation processes. The restoration contains only the modulation due to the source motion.

Babkin, Alexander S.↗

An interferometric strain-displacement measurement system

A system for measuring the relative in-plane displacement over a gage length as short as 100 micrometers is described. Two closely spaced indentations are placed in a reflective specimen surface with a Vickers microhardness tester. Interference fringes are generated when they are illuminated with a He-Ne laser. As the distance between the indentations expands or contracts with applied load, the fringes move. This motion is monitored with a minicomputer-controlled system using linear diode arrays as sensors. Characteristics of the system are: (1) gage length ranging from 50 to 500 micrometers, but 100 micrometers is typical; (2) least-count resolution of approximately 0.0025 micrometer; and (3) sampling rate of 13 points per second. In addition, the measurement technique is non-contacting and non-reinforcing. It is useful for strain measurements over small gage lengths and for crack opening displacement measurements near crack tips. This report is a detailed description of a new system recently installed in the Mechanisms of Materials Branch at the NASA Langley Research Center. The intent is to enable a prospective user to evaluate the applicability of the system to a particular problem and assemble one if needed.

Sharpe, William N., Jr.↗

Solar sensor subsystems alignment check using solar scans for the Halogen Occultation Experiment

The alignment of a dual-axes sun sensor subsystem to a telescope having a multiple sensor subsystem is described. The sun sensor consists of two analog and one digital silicon detectors. The analog detectors are shadow mask type operating in the visible spectrum. The detectors are mounted for azimuth and elevation positioning of biaxial gimbals. The digital detector is a linear diode array that operates at a spectral position of 0.7 micron and is used for elevation positioning. The position signals correspond to relative angles between the sun sensor and the solar disk. These three detectors are aligned on an Invar structure which is mounted to a Cassegrain telescope. This telescope relays solar radiance to an eight channel detector subsystem operating in the infrared range from 2 to 10 microns. The test technique and results to check the boresight alignment of these two subsystems by scanning the solar disk will be reported. The boresight alignment for both the azimuth and elevation axes of the two detector subsystems is verified using this technique.

Jurczyk, S. G.↗

Photometric observations of the energetics of small solar active regions

The energetics of small solar active regions was investigated using for the analysis the photometric solar images taken from July 29 to September 6, 1984 with the San Fernando Observatory's 28-cm vacuum telescope, vacuum spectroheliograph, and dual 512 element Reticon linear diode arrays. Ten small newly formed regions were observed, whose entire sunspot evolution apparently occurred within the observed disk crossing. Seven of these showed a net energy excess of a few times 10 to the 33th ergs during this time. These results are discussed in connection with the 0.1 percent decline in solar irradiance observed by the SMM/ACRIM and Nimbus 7/ERB radiometers between 1980 and 1986.

Lawrence, J. K.↗

Electro-optical Position-Measuring System

Electro-optical system developed to measure five components of coordinates representing position and orientation of model in test section of wind tunnel. Located entirely outside test section, uses small lasers as sources of light and self-scanning linear photodiode arrays (LPDA's) as sensing elements. With improvements in measuring ranges, adapted for use in other aerodynamic applications.

Tcheng, Ping↗

Scanning imaging absorption spectrometer for atmospheric chartography

The SCanning Imaging Absorption SpectroMeter for Atmospheric CHartographY is an instrument which measures backscattered, reflected, and transmitted light from the earth's atmosphere and surface. SCIAMACHY has eight spectral channels which observe simultaneously the spectral region between 240 and 1700 nm and selected windows between 1940 and 2400 nm. Each spectral channel contains a grating and linear diode array detector. SCIAMACHY observes the atmosphere in nadir, limb, and solar and lunar occultation viewing geometries.

Burrows, John P.↗

Real time thermal imaging for analysis and control of crystal growth by the Czochralski technique

A real time thermal imaging system with temperature resolution better than +/- 0.5 C and spatial resolution of better than 0.5 mm has been developed. It has been applied to the analysis of melt surface thermal field distributions in both Czochralski and liquid encapsulated Czochralski growth configurations. The sensor can provide single/multiple point thermal information; a multi-pixel averaging algorithm has been developed which permits localized, low noise sensing and display of optical intensity variations at any location in the hot zone as a function of time. Temperature distributions are measured by extraction of data along a user selectable linear pixel array and are simultaneously displayed, as a graphic overlay, on the thermal image.

Wargo, M. J.↗

OPAD 1991

The Optical Plume Anomaly Detection Program, an experimental study in the attempt to create a rocket engine health monitor based on detection and possible quantification of anomalous atomic and molecular species in the exhaust plume, has been in existence for several years. The instruments developed to monitor the exhaust plumes are presented. Two optical instruments are employed: the polychromator and the spectrometer. The polychromator is a 16 channel spectroradiometer having independent channels individually adjustable for center wavelength and pass bandwidth. Those values may be mechanically reset, with the aid of certain lab equipment. The spectrometer is a multichannel spectral analyzer having two 2048 element linear photodiode arrays at the exit plane of the dispersing instrument, which, like the 16 channel device, is a 1/2 meter grating spectrograph. These instruments are equipped with ultraviolet grade multifiber optical input cables, allowing the instruments to be placed in a benign environment. Telescopes mounted on the test stand observe the plume keeping the shock structure in view. The data acquisition and control system consist of four 80386-33 MHz computers: two at the test stand for instrument control and data preconditioning, and two in the test support building providing data archiving, display, and system control. Further descriptions of the instrumentation are provided.

Powers, W. T.↗

Tropospheric Emission Spectrometer for the Earth Observing System

A Tropospheric Emission Spectrometer (TES) for the Earth Observing System (EOS) series of polar-orbiting platforms is described. TES is aimed at studying tropospheric chemistry, in particular, the exchange of gases between the surface and the atmosphere, urban and regional pollution, acid rain precursors, sources and sinks of greenhouse gases, and the interchange of gases between the troposphere and the stratosphere. TES is a high-resolution (0.025/cm) infrared Fourier transform spectrometer operating in the passive thermal-emission mode in a very wide spectral range (600 to 4350/cm; 2.3 to 16.7 microns). TES has 32 spatial pixels in each of four optically conjugated linear detector arrays, each optimized for a different spectral region.

Glavich, Thomas A.↗