Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical memory”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Physical Modeling and Design of a Nonvolatile Optically Gated High‐Power Diamond Transistor

In this work, we present the theory and modeling framework of a diamond optically gated junction field‐effect transistor (DOGFET). The device utilizes nitrogen substitutional centers in type‐1b diamond to optically modulate a p‐ boron doped diamond channel. Using sub‐gap lasers with intensities as low as 100 W/cm 2 , electrons are optically excited from substitutional nitrogen sites to the conduction band of the diamond substrate, thus enabling the optical gate to exercise control on modulating the space‐charge region at the junction and therefore the channel conductivity. We show that the device can deliver a current of 7 μA/μm, or equivalently 1750 A/cm 2 , while switching at a frequency greater than 100 kHz, in a form factor of 5 μm 2 . The breakdown voltage is found to be greater than 1850 V, with a breakdown field strength of ~13 MV/cm. Moreover, the device supports nonvolatile operation with a “memory effect” enabling single transistor state retention. The presented simulation framework provides a physically grounded insight into the limits and opportunities of optoelectronic diamond systems.

Engineering - Electronic and electrical engineerin↗

Predicting Lightning Initiation using Deep Learning

Lightning occurrence presents safety challenges to people and property. The main challenge with lightning safety is that the majority of guidance is reactive. In other words, lightning has to have already occurred nearby before a person will respond and take shelter. Further, most injuries or fatalities occur as the storm approaches, or as it's moving away, when rainfall may not be present at the time of the flash. Thus, this project develops a physically-based deep learning model to produce lightning probabilities out to 15 minutes. The deep learning model combines a Convolutional Neural Network (CNN) with a Long Short-Term Memory (LSTM) network to capture both the spatial and temporal evolution of storms to predict the probability that lightning initiation will occur in the next 15 minutes. The model combines radar reflectivity, correlation coefficient and differential reflectivity to inferred storm hydrometer type and precipitation phase, which aids in the identification of electrification processes. The model is trained with data from the Geostationary Lightning Mapper (GLM), which is a near infrared sensor onboard the GOES-R series of satellites that measures optical brightness from lightning. This presentation will provide an overview of the project.

Andrew T White↗

Average nonlinear dynamics of particles in gravitational pulses: Effective Hamiltonian, secular acceleration, and gravitational susceptibility

Particles interacting with a prescribed quasimonochromatic gravitational wave (GW) exhibit secular (average) nonlinear dynamics that can be described by Hamilton’s equations. We derive the Hamiltonian of this “ponderomotive” dynamics to the second order in the GW amplitude for a general background metric. For the special case of vacuum GWs, we show that our Hamiltonian is equivalent to that of a free particle in an effective metric, which we calculate explicitly. We also show that already a linear GW pulse displaces a particle from its unperturbed trajectory by a finite distance that is independent of the GW phase and proportional to the integral of the pulse intensity.This effect is independent from the nonlinear memory effects that has been known. We calculate the particle displacement analytically and show that our result is in agreement with numerical simulations. We also show how the Hamiltonian of the nonlinear averaged dynamics naturally leads to the concept of the linear gravitational susceptibility of a particle gas with an arbitrary phase-space distribution. We calculate this susceptibility explicitly to apply it, in a follow-up paper, toward studying self-consistent GWs in inhomogeneous media within the geometrical-optics approximation

79 ASTRONOMY AND ASTROPHYSICS↗

NASA Tech Briefs, April 2007

Topics include: Wearable Environmental and Physiological Sensing Unit; Broadband Phase Retrieval for Image-Based Wavefront Sensing; Filter Function for Wavefront Sensing Over a Field of View; Iterative-Transform Phase Retrieval Using Adaptive Diversity; Wavefront Sensing With Switched Lenses for Defocus Diversity; Smooth Phase Interpolated Keying; Maintaining Stability During a Conducted-Ripple EMC Test; Photodiode Preamplifier for Laser Ranging With Weak Signals; Advanced High-Definition Video Cameras; Circuit for Full Charging of Series Lithium-Ion Cells; Analog Nonvolatile Computer Memory Circuits; JavaGenes Molecular Evolution; World Wind 3D Earth Viewing; Lithium Dinitramide as an Additive in Lithium Power Cells; Accounting for Uncertainties in Strengths of SiC MEMS Parts; Ion-Conducting Organic/Inorganic Polymers; MoO3 Cathodes for High-Temperature Lithium Thin-Film Cells; Counterrotating-Shoulder Mechanism for Friction Stir Welding; Strain Gauges Indicate Differential-CTE-Induced Failures; Antibodies Against Three Forms of Urokinase; Understanding and Counteracting Fatigue in Flight Crews; Active Correction of Aberrations of Low-Quality Telescope Optics; Dual-Beam Atom Laser Driven by Spinor Dynamics; Rugged, Tunable Extended-Cavity Diode Laser; Balloon for Long-Duration, High-Altitude Flight at Venus; and Wide-Temperature-Range Integrated Operational Amplifier.

Source record↗

Self-Latching Piezocomposite Actuator

A self-latching piezocomposite actuator includes a plurality of shape memory ceramic fibers. The actuator can be latched by applying an electrical field to the shape memory ceramic fibers. The actuator remains in a latched state/shape after the electrical field is no longer present. A reverse polarity electric field may be applied to reset the actuator to its unlatched state/shape. Applied electric fields may be utilized to provide a plurality of latch states between the latched and unlatched states of the actuator. The self-latching piezocomposite actuator can be used for active/adaptive airfoils having variable camber, trim tabs, active/deformable engine inlets, adaptive or adjustable vortex generators, active optical components such as mirrors that change shapes, and other morphing structures.

Wilkie, William K.↗

System and method for remote detection and location of gas leaks

A system for monitoring for a gas leak from a gas containing structure is disclosed. The system includes a lens that directs an image of a scene of interest through an optical filter onto a detector. The filter is associated with the lens and the filter has one or more passbands that passes wavelengths which match one or more emission or reflectively wavelengths of the gas being monitored. A detector receives the image after the image passes through the lens and the filter. The detector generates image data representing the scene including the gas containing structure. A processor is configured to process the image data by executing machine executable code stored on a memory. The machine executable code processes the image data to identify turbulence flows in the image data such that turbulence flow indicates a gas leak, and generate and send an alert in response to the identification of a turbulence flow.

O'Neill, Mary D.↗

A Third Arm for the Surgeon

In laparoscopic surgery, tiny incisions are made in the patient's body and a laparoscope (an optical tube with a camera at the end) is inserted. The camera's image is projected onto two video screens, whose views guide the surgeon through the procedure. AESOP, a medical robot developed by Computer Motion, Inc. with NASA assistance, eliminates the need for a human assistant to operate the camera. The surgeon uses a foot pedal control to move the device, allowing him to use both hands during the surgery. Miscommunication is avoided; AESOP's movement is smooth and steady, and the memory vision is invaluable. Operations can be completed more quickly, and the patient spends less time under anesthesia. AESOP has been approved by the FDA.

Source record↗

Sonoluminescence Bubble Measurements using Vision-Based Algorithms

Vision-based measurement methods were used to measure bubble sizes in this sonoluminescence experiment. Bubble imaging was accomplished by placing the bubble between a bright light source and a microscope-CCD camera system. A collimated light-emitting diode was operated in a pulsed model with an adjustable time delay with respect to the piezo-electric transducer drive signal. The light-emitting diode produced a bubble shadowgraph consisting of a multiple exposure made by numerous light pulses imaged onto a charge-couple device camera. Each image was transferred from the camera to a computer-controlled machine vision system via a frame grabber. The frame grabber was equipped with on-board memory to accomodate sequential image buffering while images were transferred to the host processor and analyzed. This configuration allowed the host computer to perform diameter measurements, centroid position measurements and shape estimation in "real-time" as the next image was being acquired. Bubble size measurement accuracy with an uncertainty of 3 microns was achieved using standard lenses and machine vision algorithms. Bubble centroid position accuracy was also within the 3 micron tolerance of the vision system. This uncertainty estimation accounted for the optical spatial resolution, digitization errors and the edge detection algorithm accuracy. The vision algorithms include camera calibration, thresholding, edge detection, edge position determination, distance between two edges computations and centroid position computations.

Hall, Nancy R.↗

Scalable Quantum Monte Carlo Method for Polariton Chemistry via Mixed Block Sparsity and Tensor Hypercontraction Method

We present a reduced-scaling auxiliary-field quantum Monte Carlo (AFQMC) framework designed for large molecular systems and ensembles, with or without coupling to optical cavities. Our approach leverages the natural block sparsity of the Cholesky decomposition (CD) of electron repulsion integrals in molecular ensembles and employs tensor hypercontraction (THC) to efficiently compress low-rank Cholesky blocks. By representing the Cholesky vectors in a mixed format, keeping high-rank blocks in block-sparse form and compressing low-rank blocks with THC, we reduce the scaling of exchange-energy evaluation from quartic to robust cubic in the number of molecular orbitals N, while lowering memory from cubic toward quadratic. Benchmark analyses on one-, two-, and three-dimensional molecular ensembles (up to ∼1,200 orbitals) show that (a) the number of nonzeros in Cholesky tensors grows linearly with system size across dimensions; (b) the average numerical rank increases sublinearly and does not saturate at these sizes; and (c) rank heterogeneity─some blocks nearly full rank and many low rank, naturally motivates the proposed mixed block sparsity and THC scheme for efficient calculation of exchange energy. In conclusion, we demonstrate that the mixed scheme yields cubic wall-time scaling with favorable prefactors and preserves AFQMC accuracy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nature of the nonequilibrium phase transition in the non-Markovian driven Dicke model

The Dicke model famously exhibits a phase transition to a superradiant phase with a macroscopic population of photons and is realized in multiple settings in open quantum systems. In this paper, we study a variant of the Dicke model where the cavity mode is lossy due to the coupling to a Markovian environment while the atomic mode is coupled to a colored bath. We analytically investigate this model by inspecting its low-frequency behavior via the Schwinger-Keldysh field theory and carefully examine the nature of the corresponding superradiant phase transition. Integrating out the fast modes, we can identify a simple effective theory allowing us to derive analytical expressions for various critical exponents including the dynamical exponent. We find excellent agreement with previous numerical results when the non-Markovian bath is at zero temperature; however, contrary to these studies, our low-frequency approach reveals that the same exponents govern the critical behavior when the colored bath is at finite temperature unless the chemical potential is zero. Furthermore, we show that the superradiant phase transition is classical in nature, while it is genuinely nonequilibrium. In this work, we derive a fractional Langevin equation and conjecture the associated fractional Fokker-Planck equation that captures the system's long-time memory as well as its nonequilibrium behavior. Finally, we consider finite-size effects at the phase transition and identify the finite-size scaling exponents, unlocking a rich behavior in both statics and dynamics of the photonic and atomic observables.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Video image processor on the Spacelab 2 Solar Optical Universal Polarimeter /SL2 SOUP/

The SOUP instrument is designed to obtain diffraction-limited digital images of the sun with high photometric accuracy. The Video Processor originated from the requirement to provide onboard real-time image processing, both to reduce the telemetry rate and to provide meaningful video displays of scientific data to the payload crew. This original concept has evolved into a versatile digital processing system with a multitude of other uses in the SOUP program. The central element in the Video Processor design is a 16-bit central processing unit based on 2900 family bipolar bit-slice devices. All arithmetic, logical and I/O operations are under control of microprograms, stored in programmable read-only memory and initiated by commands from the LSI-11. Several functions of the Video Processor are described, including interface to the High Rate Multiplexer downlink, cosmetic and scientific data processing, scan conversion for crew displays, focus and exposure testing, and use as ground support equipment.

Lindgren, R. W.↗

Weaves as an Interconnection Fabric for ASIM's and Nanosatellites

Many of the micromachines under consideration require computer support, indeed, one of the appeals of this technology is the ability to intermix mechanical, optical, analog, and digital devices on the same substrate. The amount of computer power is rarely an issue, the sticking point is the complexity of the software required to make effective use of these devices. Micromachines are the nano-technologist's equivalent of 'golden screws'. In other words, they will be piece parts in larger assemblages. For example, a nano-satellite may be composed of stacked silicon wafers where each wafer contains hundreds to thousands of micromachines, digital controllers, general purpose computers, memories, and high-speed bus interconnects. Comparatively few of these devices will be custom designed, most will be stock parts selected from libraries and catalogs. The novelty will lie in the interconnections. For example, a digital accelerometer may be a component part in an adaptive suspension, a monitoring element embedded in the wrapper of a package, or a portion of the smart skin of a launch vehicle. In each case, this device must inter-operate with other devices and probes for the purposes of command, control, and communication. We propose a software technology called 'weaves' that will permit large collections of micromachines and their attendant computers to freely intercommunicate while preserving modularity, transparency, and flexibility. Weaves are composed of networks of communicating software components. The network, and the components comprising it, may be changed even while the software, and the devices it controls, are executing. This unusual degree of software plasticity permits micromachines to dynamically adapt the software to changing conditions and allows system engineers to rapidly and inexpensively develop special purpose software by assembling stock software components in custom configurations.

Gorlick, Michael M.↗

Multiplexed Holographic Data Storage in Bacteriorhodopsin

High density optical data storage, driven by the information revolution, remains at the forefront of current research areas. Much of the current research has focused on photorefractive materials (SBN and LiNbO3) and polymers, despite various problems with expense, durability, response time and retention periods. Photon echo techniques, though promising, are questionable due to the need for cryogenic conditions. Bacteriorhodopsin (BR) films are an attractive alternative recording medium. Great strides have been made in refining BR, and materials with storage lifetimes as long as 100 days have recently become available. The ability to deposit this robust polycrystalline material as high quality optical films suggests the use of BR as a recording medium for commercial optical disks. Our own recent research has demonstrated the suitability of BR films for real time spatial filtering and holography. We propose to fully investigate the feasibility of performing holographic mass data storage in BR. Important aspects of the problem to be investigated include various data multiplexing techniques (e.g. angle- amplitude- and phase-encoded multiplexing, and in particular shift-multiplexing), multilayer recording techniques, SLM selection and data readout using crossed polarizers for noise rejection. Systems evaluations of storage parameters, including access times, memory refresh constraints, erasure, signal-to-noise ratios and bit error rates, will be included in our investigations.

Mehrl, David J.↗

A Reversible Structural Phase Transition by Electrochemically-Driven Ion Injection into a Conjugated Polymer

We nd that conjugated polymers can undergo reversible structural phase transitions during electrochemical oxidation and ion injection. We study poly[2,5-bis(thiophenyl)-1,4-bis(2-(2-(2- methoxyethoxy)ethoxy)ethoxy)benzene] (PB2T-TEG), a conjugated polymer with glycolated side chains. Using grazing incidence wide angle X-ray scattering (GIWAXS), we show that, in contrast to previously known polymers, this polymer switches between two structurally distinct crystalline phases associated with electrochemical oxidation/reduction in an aqueous electrolyte. Importantly, we show that this unique phase change behavior has important physical consequences for ion transport. Notably, using moving front experi- ments visualized by both optical microscopy and super-resolution photoinduced force microscopy (PiFM), we show that a propagating ion front in PB2T-TEG exhibits non-Fickian transport, retaining a sharp step-edge prole, in stark contrast to the Fickian diusion more commonly observed. This structural phase transition is reminiscent of those accompanying ion uptake in inorganic materials like LiFePO4. We propose that engineering similar properties in future conjugated polymers may enable the realization of new materials with superior performance in electrochemical energy storage or neuromorphic memory applications.

Bischak, Connor G.↗

Thermal Radiation Transport with Tensor Trains

We present a novel tensor network algorithm to solve the time-dependent, gray thermal radiation transport equation. The method invokes a tensor train (TT) decomposition for the specific intensity. The efficiency of this approach is dictated by the rank of the decomposition. When the solution is “low rank,” the memory footprint of the specific intensity solution vector may be significantly compressed. The algorithm, following a step-then-truncate approach of a traditional discrete ordinates method, operates directly on the compressed state vector, thereby enabling large speedups for low-rank solutions. To achieve these speedups, we rely on a recently developed rounding approach based on the Gram-SVD. We detail how familiar S N algorithms for (gray) thermal transport can be mapped to this TT framework and present several numerical examples testing both the optically thick and thin regimes. The TT framework finds low-rank structure and supplies up to ≃60× speedups and ≃1000× compressions for problems demanding large angle counts, thereby enabling previously intractable SN calculations and supplying a promising avenue to mitigate ray effects.

79 ASTRONOMY AND ASTROPHYSICS↗

Photophysics of O-band and transition metal color centers in monolithic silicon for quantum communications

Color centers in the O-band (1260–1360 nm) are crucial for realizing long-coherence quantum network nodes in memory-assisted quantum communications. However, only a limited number of O-band color centers have been thoroughly explored in silicon hosts as spin-photon interfaces. This study explores and compares two promising O-band color centers in silicon for high-fidelity spin-photon interfaces: T and *Cu (transition metal) centers. During T center generation process, we observed the formation and dissolution of other color centers, including the copper-silver related centers with a doublet line around 1312 nm (*Cu$^0_n$), near the optical fiber zero dispersion wavelength (around 1310 nm). We then investigated the photophysics of both T and *Cu centers, focusing on their emission spectra and spin properties. The *Cu$^0_0$ line under a 0.5 T magnetic field demonstrated a 25% broadening, potentially due to spin degeneracy, suggesting that this center can be a promising alternative to T centers.

42 ENGINEERING↗

Optimal Padding for the Two-Dimensional Fast Fourier Transform

One-dimensional Fast Fourier Transform (FFT) operations work fastest on grids whose size is divisible by a power of two. Because of this, padding grids (that are not already sized to a power of two) so that their size is the next highest power of two can speed up operations. While this works well for one-dimensional grids, it does not work well for two-dimensional grids. For a two-dimensional grid, there are certain pad sizes that work better than others. Therefore, the need exists to generalize a strategy for determining optimal pad sizes. There are three steps in the FFT algorithm. The first is to perform a one-dimensional transform on each row in the grid. The second step is to transpose the resulting matrix. The third step is to perform a one-dimensional transform on each row in the resulting grid. Steps one and three both benefit from padding the row to the next highest power of two, but the second step needs a novel approach. An algorithm was developed that struck a balance between optimizing the grid pad size with prime factors that are small (which are optimal for one-dimensional operations), and with prime factors that are large (which are optimal for two-dimensional operations). This algorithm optimizes based on average run times, and is not fine-tuned for any specific application. It increases the amount of times that processor-requested data is found in the set-associative processor cache. Cache retrievals are 4-10 times faster than conventional memory retrievals. The tested implementation of the algorithm resulted in faster execution times on all platforms tested, but with varying sized grids. This is because various computer architectures process commands differently. The test grid was 512 512. Using a 540 540 grid on a Pentium V processor, the code ran 30 percent faster. On a PowerPC, a 256x256 grid worked best. A Core2Duo computer preferred either a 1040x1040 (15 percent faster) or a 1008x1008 (30 percent faster) grid. There are many industries that can benefit from this algorithm, including optics, image-processing, signal-processing, and engineering applications.

Dean, Bruce H.↗

Far Ultraviolet Imaging from the Image Spacecraft: Wideband FUV Imaging - 2

The Far Ultraviolet Wideband Imaging Camera (WIC) complements the magnetospheric images taken by the IMAGE satellite instruments with simultaneous global maps of the terrestrial aurora. Thus, a primary requirement of WIC is to image the total intensity of the aurora in wavelength regions most representative of the aurora] source and least contaminated by dayglow, have sufficient field of view to cover the entire polar region from spacecraft apogee and have resolution that is Sufficient to resolve auroras on a scale of 1 to 2 latitude degrees, The instrument is sensitive in the spectral region from 140- 190 nm. The WIC is mounted on the rotating, IMAGE spacecraft viewing radially outward and has a field of view of 17 deg in the direction parallel to the spacecraft spin axis. Its field of view is 30 deg in the direction perpendicular to the spin axis, although only a 17 deg x 17 deg image of the Earth is recorded. The optics was an all-reflective, inverted Cassegrain Burch camera using concentric optics with a small convex primary and a large concave secondary mirror. The mirrors were coated by a special multi-layer coating, which has low reflectivity in the visible and near UV region, The detector consists of a MCP-Intensified CCD. The MCP is curved to accommodate the focal surface of the concentric optics. Tile phosphor of the image intensifier is deposited on a concave fiberoptic window, which is then Coupled to the CCD with a fiberoptic taper. The camera head operates in a fast frame transfer mode with the CCD being read approximately 30 full frames (512 by 256 pixel) per second with an exposure time of 0.033 s. The image motion (file to the satellite spin is minimal during such a short exposure. Each image is electronically distortion corrected using the look up table scheme. An offset is added to each memory address that is proportional to the image shift due to satellite rotation, and the charge signal is digitally summed in memory. On orbit, approximately 300 frames will be added to produce one WIC image in memory. The advantage of the electronic motion compensation and distortion correction is that it is extremely flexible, permitting several kinds of corrections including motions parallel and perpendicular to the predicted axis of rotation. File instrument was calibrated by applying ultraviolet light through a vacuum monochromator and measuring the absolute responsivity of the instrument. To obtain the data for the distortion look up table the camera was turned through various angles and the input angles corresponding to a pixel matrix were recorded. It was found that the spectral response peaked at 150 nm and fell off in either direction. The equivalent aperture of the camera, including mirror reflectivities and effective photocathode quantum efficiency, is about 0.04 sq cm. Thus, a 100 Rayleigh LBH aurora is expected to produce 23 equivalent counts per pixel per 10 s exposure at the peak of instrument response.

Mende, S. B.↗