Search NASA⌕ Search

SEARCH · Search NASA

Results for “orifice”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Jet mixing into a heated cross flow in a cylindrical duct: Influence of geometry and flow variations

To examine the mixing characteristics of jets in an axi-symmetric can geometry, temperature measurements were obtained downstream of a row of cold jets injected into a heated cross stream. Parametric, non-reacting experiments were conducted to determine the influence of geometry and flow variations on mixing patterns in a cylindrical configuration. Results show that jet to mainstream momentum flux ratio and orifice geometry significantly impact the mixing characteristics of jets in a can geometry. For a fixed number of orifices, the coupling between momentum flux ratio and injector determines (1) the degree of jet penetration at the injection plane, and (2) the extent of circumferential mixing downstream of the injection plane. The results also show that, at a fixed momentum flux ratio, jet penetration decreases with (1) an increase in slanted slot aspect ratio, and (2) an increase in the angle of the slots with respect to the mainstream direction.

Hatch, M. S.↗

Experimental Study of Cross-Stream Mixing in a Rectangular Duct

An experimental investigation of non-reacting cross-stream jet injection and mixing in a rectangular duct was conducted for application in a low emissions combustor. Planar digital imaging was used to measure concentration distributions in planes perpendicular to the duct axis. Mixing rate was measured for 45 deg slanted slot and round orifice injectors. Five areas of inquiry are discussed: (1) mixing improves continuously with increasing momentum-flux ratio; (2) given a momentum-flux ratio, there is an optimum, orifice spacing; (3) mixing is more dependent on injector geometry than mass flow ratio; (4) mixing is influenced by relative slot orientation; and (5) jet structure is different for round holes and slanted slots injectors. The utility of acquiring multipoint fluctuating properties of the flow field is also demonstrated.

Liscinsky, D. S.↗

Ultra-high temperature stability Joule-Thomson cooler with capability to accomodate pressure variations

A Joule-Thomson cryogenic refrigeration system capable of achieving high temperature stabilities in the presence of varying temperature, atmospheric pressure, and heat load is provided. The Joule-Thomson cryogenic refrigeration system includes a demand flow Joule-Thomson expansion valve disposed in a cryostat of the refrigeration system. The expansion valve has an adjustable orifice that controls the flow of compressed gas therethrough and induces cooling and partial liquefaction of the gas. A recuperative heat exchanger is disposed in the cryostat and coupled to the expansion valve. A thermostatically self-regulating mechanism is disposed in the cryostat and coupled to the J-T expansion valve. The thermostatically self-regulating mechanism automatically adjusts the cross sectional area of the adjustable valve orifice in response to environmental temperature changes and changes in power dissipated at a cold head. A temperature sensing and adjusting mechanism is coupled to a cold head for adjusting the temperature of the cold head in response to the change in heat flow in the cold head. The temperature sensing and adjusting mechanism comprises a temperature sensitive diode, a wound wire heater, and an electrical feedback control circuit coupling the diode to the heater. An absolute pressure relief valve is interposed between the output of the cryostat and an exhaust port for maintaining a constant exhaust temperature in the refrigerating system, independent of the changes in atmospheric pressure.

Bard, Steven↗

A review of pulse tube refrigeration

This paper reviews the development of the three types of pulse tube refrigerators: basic, resonant, and orifice types. The principles of operation are given. It is shown that the pulse tube refrigerator is a variation of the Stirling-cycle refrigerator, where the moving displacer is substituted by a heat transfer mechanism or by an orifice to bring about the proper phase shifts between pressure and mass flow rate. A harmonic analysis with phasors is described which gives reasonable results for the refrigeration power, yet is simple enough to make clear the processes which give rise to the refrigeration. The efficiency and refrigeration power are compared with those of other refrigeration cycles. A brief review is given of the research being done at various laboratories on both one- and two-stage pulse tubes. A preliminary assessment of the role of pulse tube refrigerators is discussed.

Radebaugh, Ray↗

Low capacity Linde-Hampson nitrogen liquefier

A closed-cycle Linde-Hampson nitrogen liquefier was developed incorporating a new, non-clogging, demand flow Joule-Thomson nozzle. The flow area of the nozzle, a tapered annular orifice, is regulated by a very rugged load-sensitive differential thermal expansion scheme and by a manually adjustable micrometer mechanism. Labyrinth flow spoilers within the orifice provide turbulent voids which break up and clear contaminants from the flow. The system's four-stage compressor features sealed, oil-free compression spaces and a very compact nested piston configuration with a minimum of moving parts and drive complexity. The drive mechanism is a rolling Scotch yoke which minimizes piston side forces and seal wear for prolonged operating life. The closed-cycled system is controlled by an innovative load-responsive electronic feedback circuit which further reduces wear and input power.

Hedegard, K.↗

Factors influencing the effective spray cone angle of pressure-swirl atomizers

The spray cone angles produced by several simplex pressure-swirl nozzles are examined using three liquids whose viscosities range from 0.001 to 0.012 kg/ms (1 to 12 cp). Measurements of both the visible spray cone angle and the effective spray cone angle are carried out over wide ranges of injection pressure and for five different values of the discharge orifice length/diameter ratio. The influence of the number of swirl chamber feed slots on spray cone angle is also examined. The results show that the spray cone angle widens with increase in injection pressure but is reduced by increases in liquid viscosity and/or discharge orifice length/diameter ratio. Variation in the number of swirl chamber feed slots between one and three has little effect on the effective spray cone angle.

Chen, S. K.↗

Jet mixing into a heated cross flow in a cylindrical duct - Influence of geometry and flow variations

To examine the mixing characteristics of jets in an axi-symmetric can geometry, temperature measurements were obtained downstream of a row of cold jets injected into a heated cross stream. Parametric, non-reacting experiments were conducted to determine the influence of geometry and flow variations on mixing patterns in a cylindrical configuration. Results show that jet to mainstream momentum flux ratio and orifice geometry significantly impact the mixing characteristics of jets in a can geometry. For a fixed number of orifices, the coupling between momentum flux ratio and injector determines (1) the degree of jet penetration at the injection plane, and (2) the extent of circumferential mixing downstream of the injection plane. The results also show that, at a fixed momentum flux ratio, jet penetration decreases with (1) an increase in slanted slot aspect ratio, and (2) an increase in the angle of the slots with respect to the mainstream direction.

Hatch, M. S.↗

Experimental study of cross-stream mixing in a rectangular duct

An experimental investigation of non-reacting cross-stream jet injection and mixing in a rectangular duct was conducted for application in a low emissions combustor. Planar digital imaging was used to measure concentration distributions in planes perpendicular to the duct axis. Mixing rate was measured for 45 deg slanted slot and round orifice injectors. Five areas of inquiry are discussed: (1) mixing improves continuously with increasing momentum-flux ratio; (2) given a momentum-flux ratio, there is an optimum, orifice spacing; (3) mixing is more dependent on injector geometry than mass flow ratio; (4) mixing is influenced by relative slot orientation; and (5) jet structure is different for round holes and slanted slots injectors. The utility of acquiring multipoint fluctuating properties of the flow field is also demonstrated.

Liscinsky, D. S.↗

Air data system optimization using a genetic algorithm

An optimization method for flush-orifice air data system design has been developed using the Genetic Algorithm approach. The optimization of the orifice array minimizes the effect of normally distributed random noise in the pressure readings on the calculation of air data parameters, namely, angle of attack, sideslip angle and freestream dynamic pressure. The optimization method is applied to the design of Pressure Distribution/Air Data System experiment (PD/ADS) proposed for inclusion in the Aeroassist Flight Experiment (AFE). Results obtained by the Genetic Algorithm method are compared to the results obtained by conventional gradient search method.

Deshpande, Samir M.↗

Modifications Of A Commercial Spray Gun

Commercial spray gun modified to increase spray rate and make sprayed coats more nearly uniform. Consists of gun head and pneumatic actuator. Actuator opens valves for two chemical components, called "A" and "B," that react to produce foam. Components flow through orifices, into mixing chamber in head. Mixture then flows through control orifice to spray tip. New spray tip tapered to reduce area available for accumulation of foam and makes tip easier to clean.

Allen, Peter B.↗

SUMS experiment flight results on STS-35

Calibrated pressure measurements for species with mass to charge ratios up to 50 amu/e(-) were obtained from the Shuttle Upper Atmosphere Mass Spectrometer (SUMS) experiment during reentry on the STS-35 mission. Data were collected from 180 km, when the signal rose above the background, to about 87 km, when the SUMS system automatically closed the gas inlet value. However, data above 115 km was contaminated from a source of gas emanating from pressure transducers connected in parallel to the mass spectrometer. At lower altitudes, the pressure transducer data is compared with the mass spectrometer total pressure with excellent agreement. The free-stream density in the rarefied flow flight regime is calculated using an orifice pressure coefficient model based upon direct simulation Monte Carlo results. This density, when compared with the 1976 U.S. standard atmosphere model, exhibits the wave-like nature seen on previous flights using accelerometry. In addition, selected spectra are presented at higher altitudes (320 km) showing the effects of the ingestion of gases from a forward fuselage fuel dump. An analysis of the spectra data from this event is presented to show that no significant permanent changes occurred which affected the data interpretation at lower altitudes. Further, the localized chemistry from the individual species during the onset of aerodynamic heating is examined to the extent possible for a closed source system, such as SUMS. Near the orifice entrance, a significant amount of CO2 was generated from chemical reactions with the carbon panels of the Orbiter and absorbed oxygen on the system tubing.

Blanchard, Robert C.↗

Experimental effects of wing location on wing-body pressures at supersonic speeds

An experimental study was performed at supersonic speeds to measure wing and body spanwise pressure distributions on an axisymmetric-body delta wing model on which the wing vertical location on the body was systematically varied from low- to high-mounted positions. In addition, for two of these positions both horizontal and radial wing angular orientations relative to the body were tested, and roll angle effects were investigated for one of the positions. Seven different wing-body configurations and a body-alone configuration were studied. The test was conducted at Mach numbers from 1.70 to 2.86 at angles of attack from about -4 deg to 24 deg. Pressure orifices were located at three longitudinal stations on each wing-body model, and at each station the orifices were located completely around the body, along the lower surface of the right wing (looking upstream), and along the upper surface of the left wing. All pressure coefficient data are tabulated and selected samples are shown graphically to illustrate the effects of the test variables. The effects of angle of attack, roll angle, Mach number, longitudinal station, wing vertical location, wing angular orientation, and wing-body juncture are analyzed. The vertical location of the wing on the body had a very strong effect on the body pressures. For a given angle of attack at a roll angle of 0 deg, the pressures were virtually constant in the spanwise direction across the windward surfaces of the wing-body combination. Pressure-relieving, channeling, and vortex effects were noted in the data.

Allen, Jerry M.↗

An Analytical Study of Dilution Jet Mixing in a Cylindrical Duct

The mixing performance in a mixing section of a rich burn/quick mix/lean burn (RQL) combustor was calculated using a 3-D numerical model in a non-reacting environment. The numerically calculated results were compared with the measured data reported by Hatch, Sowa, Samuelsen, and Holdeman, 1992. The numerical 3-D temperature fields qualitatively agree with the experimental data. Also, the development of the mixing flow and temperature non-uniformity trends throughout the mixing section for the numerically calculated results quantitatively agree with the measured data. The numerical model predicts less mixing and enhances the temperature gradients as compared to the measured data for the cases reported by Hatch et al. (1992) which include circular and slot orifice shapes (with different slant angles and aspect ratios). The predicted and measured results generally agree in the selection of the slanted slot orifice configuration yielding the best overall mixing performance (based on temperature uniformity) of all the configurations analyzed.

Oechsle, V. L.↗

An evaluation of Shuttle Entry Air Data System (SEADS) flight pressures - Comparisons with wind tunnel and theoretical predictions

The SEADS pressure data obtained from the Shuttle flight 61-C are analyzed in conjunction with the preflight database. Based on wind tunnel data, the sensitivity of the Shuttle Orbiter stagnation region pressure distribution to angle of attack and Mach number is demonstrated. Comparisons are made between flight and wind tunnel SEADS orifice pressure distributions at several points throughout the re-entry. It is concluded that modified Newtonian theory provides a good tool for the design of a flush air data system, furnishing data for determining orifice locations and transducer sizing. Ground-based wind tunnel facilities are capable of providing the correction factors necessary for the derivation of accurate air data parameters from pressure data.

Henry, M. W.↗

DSMC simulation of the interaction between rarefied free jets

This paper presents a direct simulation Monte Carlo (DSMC) calculation of two interacting free jets exhausting into vacuum. The computed flow field is compared against available experimental data and shows excellent agreement everywhere except in the very near field (less than one orifice diameter downstream of the jet exhaust plane). The lack of agreement in this region is attributed to having assumed an inviscid boundary condition for the orifice lip. The results serve both to validate the DSMC code for a very complex, three dimensional non-equilibrium flow field, and to provide some insight as to the complicated nature of this flow.

Dagum, Leonardo↗

An analytical study of dilution jet mixing in a cylindrical duct

The mixing performance in a mixing section of a rich burn/quick mix/lean burn (RQL) combustor was calculated using a 3-D numerical model in a non-reacting environment. The numerically calculated results were compared with the measured data reported by Hatch, Sowa, Samuelsen, and Holdeman, 1992. The numerical 3-D temperature fields qualitatively agree with the experimental data. Also, the development of the mixing flow and temperature non-uniformity trends throughout the mixing section for the numerically calculated results quantitatively agree with the measured data. The numerical model predicts less mixing and enhances the temperature gradients as compared to the measured data for the cases reported by Hatch et al. (1992) which include circular and slot orifice shapes (with different slant angles and aspect ratios). The predicted and measured results generally agree in the selection of the slanted slot orifice configuration yielding the best overall mixing performance (based on temperature uniformity) of all the configurations analyzed.

Oechsle, V. L.↗

CFD mixing analysis of axially opposed rows of jets injected into confined crossflow

A CFD parametric study was performed to analyze axially opposed rows of jets mixing with crossflow in a rectangular duct. An isothermal analysis was conducted to determine the influence of lateral geometric arrangement on mixing for the cases of: (1) inline (jets' centerlines aligned with each other on top and bottom walls), and (2) staggered (jets' centerlines offset with each other on top and bottom walls) configurations. For a jet-to-mainstream mass flow ratio (MR) of 2.0, design parameters were systematically varied for jet-to-mainstream momentum-flux ratios (J) between 16 and 64 and orifice spacing-to-duct height ratios (S/H) between 0.125 and 1.5. Comparisons were made between geometries optimized for S/H at a specified J. Inline configurations had a unique spacing for best mixing at a specified J. In contrast, staggered configurations had two 'good mixing' spacings for each J, one corresponding to optimum inline spacing and the other corresponding to optimum nonimpinging jet spacing. Increasing J resulted in better mixing characteristics if each configuration was optimized with respect to orifice spacing. Mixing performance was shown to be similar to results from previous dilution jet mixing investigations (MR less than 0.5).

Bain, D. B.↗

An Investigation of the Characteristics of Steel Diaphragms for Automatic Fuel-Injection Valves

This research on steel diaphragms was undertaken at the Langley Memorial Aeronautical Laboratory, as a part of a general investigation on fuel injection engines for aircraft. The work determined the load-deflection, load- deformation and hysteresis characteristics for single diaphragms having thicknesses from 0.00s inch to 0.012 inch, and for similar diaphragms tested in multiple having total thicknesses from 0.012 inch to 0.180 inch. The elastic limit loads and deflections, and rupture points of single diaphragms were also determined. Some work was done on diaphragms having central orifices in order to determine the effect of orifice diameter upon the load deflection characteristics.

Joachim, W F↗