Search NASA⌕ Search

SEARCH · Search NASA

Results for “radiance calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Characterization and Calibration of an AERONET-OC Radiometer

The Ocean Color component of the global Aerosol Robotic Network (AERONET-OC) utilizes CE-318 sun photometers modified for above-water radiometry from fixed structures such as oil rigs, lighthouses and service platforms. Primarily, AERONET-OC measurements allow determination of the water-leaving radiance required for the validation of ocean color satellite data products. In this study, we characterized and calibrated one instrument from the AERONET-OC network, identified as AERONET #080. A laser-illuminated integrating sphere of known radiance enabled determination of the absolute radiance responsivity for 7 bands. We compared the results to calibrations from the AERONET facility at the Goddard Space Flight Center of the National Aeronautics and Space Administration and from the Joint Research Centre of the European Commission. These results agree within the estimated mean comparison uncertainty of 1.88 % (k = 2). We also assessed these results using calibrated lamp-illuminated integrating spheres and observed a spectral dependence to the comparison results that is unexplained.

B. C. Johnson↗

Vicarious Calibration of the Long Near Infrared Band: Cross-Sensor Differences in Sensitivity

Numerous assumptions and approximations are employed when translating satellite-derived radiance to surface remote sensing reflectance (RRS) for ocean color applications. Among these is the vicarious calibration coefficient (g) of the “long” near infrared band (NIRL) used for atmospheric correction. For this band, the prelaunch calibration has always been deemed sufficient [thus g(NIRL) = 1.00] as long as other bands are vicariously calibrated. Recent research, however, suggests that Moderate Resolution Imaging Spectroradiometer (MODIS)/Aqua RRS time series is quite sensitive to g(NIRL) (and associated vicarious gains in other bands). In this work, we assessed the sensitivity of Visible Infrared Imaging Radiometer Suite onboard the Suomi National Polar-orbiting Partnership satellite (VIIRS/SNPP) RRS to NIRL calibration and compared our results to previous MODIS/Aqua and Sea-viewing Wide Field-of-View Sensor onboard OrbView2 (SeaWiFS)/OrbView2 analysis. In doing so, we note that g(NIRL) sensitivities of mission-averaged RRS time series are lower for VIIRS and Sea-WiFS, relative to MODIS. At the scale of monthly climatologies (MCs), however, all sensors show prominent g(NIRL) sensitivity with that of SeaWiFS being the most substantial. These findings informed simulation analyses, whereby we identified signal-tonoise ratio (SNR) and radiant path geometry, as well as their interaction, as having notable impacts on g(NIRL) sensitivity. As such, g(NIRL) sensitivity is a necessary consideration for reflectance uncertainty budgets, especially for sensors with higher NIR SNR or particular prevailing radiant path geometries. Given the geometry components embedded within g(NIRL) sensitivity, such studies should be coupled with cross-sensor intercalibrations [e.g., using simultaneous same view (SSV) measurements] toward minimizing NIRL errors between satellite instruments, but such efforts will not completely remediate remaining cross-sensor biases in RRS. Index Terms—Moderate Resolution Imaging Spectroradiometer (MODIS)/Aqua, ocean color, ocean gyres, Sea-viewing Wide Field-of-View Sensor onboard OrbView2 (SeaWiFS), system vicarious calibration (SVC), Visible Infrared Imaging Radiometer Suite onboard the Suomi National Polar-orbiting Partnership satellite (VIIRS/SNPP).

MODIS↗

Vicarious Calibration of the Long Near Infrared Band: Cross-Sensor Differences in Sensitivity

Numerous assumptions and approximations are employed when translating satellite-derived radiance to surface remote sensing reflectance (RRS) for ocean color applications. Among these is the vicarious calibration coefficient (g) of the ‘long’ near infrared band (NIRL) used for atmospheric correction. For this band, the pre-launch calibration has always been deemed sufficient [thus g(NIRL) = 1.00] as long as other bands are vicariously calibrated. Recent research, however, suggests that MODIS/Aqua RRS time series are quite sensitive to g(NIRL) (and associated vicarious gains in other bands). In this work, we assessed the sensitivity of VIIRS/SNPP RRS to NIRL calibration, and compared our results to previous MODIS/Aqua and SeaWiFS/OrbView2 analysis. In doing so, we note g(NIRL) sensitivities of mission-averaged RRS timeseries are lower for VIIRS and SeaWiFS, relative to MODIS. At the scale of monthly climatologies, however, all sensors show prominent g(NIRL) sensitivity, with that of SeaWiFS being the most substantial. These findings informed simulation analyses, whereby we identified signal-to-noise ratio (SNR) and radiant path geometry, as well as their interaction, as having notable impacts on g(NIRL) sensitivity. As such, g(NIRL) sensitivity is a necessary consideration for reflectance uncertainty budgets, especially for sensors with higher NIR SNR or particular prevailing radiant path geometries. Given the geometry components embedded within g(NIRL) sensitivity, such studies should be coupled with cross-sensor intercalibrations (e.g., using simultaneous same view measurements) toward minimizing NIRL errors between satellite instruments, but such efforts will not completely remediate remaining cross-sensor biases in RRS.

Brian B Barnes↗

Inflight Validation of AVIRIS Calibration in 1996 and 1997

The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) measures spectral radiance in the solar reflected spectrum from 400 to 2500 nm. Spectra are measured through 224 spectral channels with nominally 10-nm sampling and 10-nm full width at half maximum (FWHM). From a NASA ER-2 aircraft flying at 20,000 m altitude, these spectra are acquired as images with an 11-km width by up to 800-km length. The spatial sampling is 17 m, and the instantaneous field of view (IFOV) 20 m. The objective of AVIRIS is to acquire calibrated spectra that are used to derive properties of the Earth's land, water, and atmosphere for scientific research and environmental applications. To achieve this objective, the AVIRIS spectra must be calibrated. The AVIRIS sensor is calibrated in the laboratory before and after each flight season, however, the spectra acquired by AVIRIS for science investigators are acquired in the Q-bay of the ER-2 at 20 km altitude. The objective of the AVIRIS inflight calibration experiment is to validate the calibration of AVIRIS spectral images in the low pressure, low temperature operating environment of the ER-2. Inflight calibration experiments have been orchestrated for AVIRIS in every year of flight operations.

Green, Robert O.↗

SNPP VIIRS RSB on-orbit radiometric calibration algorithms Version 2.0 and the performances. Part II: The performances

In Part I (Lei et. al, submitted to J. of Appl. Rem. Sens.),we gave detailed reviews of the algorithms Version 2.0 used for the on-orbit radiometric calibration of the reflective solar bands (RSBs) of the first Visible Infrared Imaging Radiometer Suite instrument. These algorithms improve the accuracy of the measured on-orbit change factor of the solar diffuser bidirectional reflectance distribution function, the H-factor, and reveal that the H-factor is angle dependent. With the help of lunar observations and the improved H-factor, the algorithms give more accurate values for the RSB detector on-orbit F-factor changes (F-factor is a correction factor to the initially retrieved scene spectral radiance). In this paper we review the RSB radiometric calibration performances. We show the H-factor temporal trend, the estimated uncertainty of the retrieved H-factor, and the F-factor temporal trend. Additionally we show the detector signal-to-noise ratio (SNR), the estimated uncertainty of the top-of-the-atmosphere solar spectral reflectance, the reflectance temporal trend for the Libya 4 desert, and the differences in the reflectances among the SNPP and the NOAA-20 VIIRS, and the Aqua MODIS. Our results show that although the SNRs trend downwards, they exceed the requirements by large margins. The reflectances from the Libya 4 desert show that the SNPP VIIRS’ reflectance is higher than those of the Aqua MODIS and the NOAA-20 VIIRS.

on-orbit calibration↗

SNPP VIIRS RSB on-orbit radiometric calibration algorithms Version 2.0 and the performances. Part II: The performances

In Part I (Lei et. al, submitted to J. of Appl. Rem. Sens.),we gave detailed reviews of the algorithms Version 2.0 used for the on-orbit radiometric calibration of the reflective solar bands (RSBs) of the first Visible Infrared Imaging Radiometer Suite instrument. These algorithms improve the accuracy of the measured on-orbit change factor of the solar diffuser bidirectional reflectance distribution function, the H-factor, and reveal that the H-factor is angle dependent. With the help of lunar observations and the improved H-factor, the algorithms give more accurate values for the RSB detector on-orbit F-factor changes (F-factor is a correction factor to the initially retrieved scene spectral radiance). In this paper we review the RSB radiometric calibration performances. We show the H-factor temporal trend, the estimated uncertainty of the retrieved H-factor, and the F-factor temporal trend. Additionally we show the detector signal-to-noise ratio (SNR), the estimated uncertainty of the top-of-the-atmosphere solar spectral reflectance, the reflectance temporal trend for the Libya 4 desert, and the differences in the reflectances among the SNPP and the NOAA-20 VIIRS, and the Aqua MODIS. Our results show that although the SNRs trend downwards, they exceed the requirements by large margins. The reflectances from the Libya 4 desert show that the SNPP VIIRS’ reflectance is higher than those of the Aqua MODIS and the NOAA-20 VIIRS

Ning Lei↗

Monitoring VIIRS Thermal Emissive Bands Long-Term Performance Using Lunar Observations

Two Visible Infrared Imaging Radiometer Suite (VIIRS) instruments are currently operating in space, one onboard the Suomi National Polar-orbiting Partnership (S-NPP) satellite launched on October 28, 2011 and the other onboard the NOAA-20 satellite launched on November 18, 2017. The performance of the seven VIIRS thermal emissive bands (TEBs) is monitored via on-orbit calibration data, the analysis of Earth view observations, as well as inter-comparisons with other sensors. The Moon has been used as a unique invariant target for on-orbit sensor calibration because its surface property is considered extremely stable over time in spectra, radiometry, and geometry with a repeatable lunar phase. This paper presents the assessments of the S-NPP and NOAA-20 VIIRS TEB on-orbit calibration stability using near-monthly scheduled lunar observations over their respective missions. The methodology previously developed for MODIS is now applied to VIIRS to monitor the TEB long-term stability by extracting and trending the lunar brightness temperatures from selected unsaturated pixels. It includes a correction applied to reduce any impact from the Sun–Moon geometry (e.g. Sun-Moon distance variation). The results show that the mission-long brightness temperature trends from the lunar surface are stable for all VIIRS TEBs, despite noticeable seasonal variations in the lunar thermal emissive radiance.

VIIRS↗

Contrasting Target, Stray-Light, and Other Performance Metrics for MISR

The Multi-angle Imaging Spectrometer (MISR) is an Earth-observing sensor to be flown as part of the Earth Observing System (EOS) in 1998. The radiometric and spectral calibration of the nine cameras which compose this instrument will be done using targets which are uniform in space and in angle, unpolarized, and lacking in absorption lines. A calibration uncertainty will also be determined for this configuration. This allows one to estimate the accuracy of measured radiances, assuming the scene is likewise featureless with respect to these parameters. In addition to these calibrations, the MISR engineering team will be responsible for verification of certain performance specifications which assure data products can be produced for a range of target types.

Multi-angle Imaging Spectrometer MISR Earth Observ↗

TPSAS-NF1676L-32323-DND

The GSICS VIS/NIR subgroup has several items to discuss and to provide a brief summary of the GSICS VIS/NIR activities. The first item is currently using Aqua-MODIS as the visible calibration reference. The plan is to migrate to NPP-VIIRS as the visible calibration reference. Then official source is the NOAA NPP VIIRS dataset, which is only archived with V0. However, NOAA has updated the calibration known as V2. The specifics will be discussed of how to scale the V0 visible radiances to the V2 standard. Second item is to outline a deep convective cloud (DCC) paper visible calibration paper with input from the various agencies using the GSICS DCC calibration approach. Also, to finalize the solar spectra selection. Lastly, to start the conversation with Rayleigh scattering calibration. Several slides will be compile using conclusions from GSICS web meetings, which are compiled from input across multiple agencies. Topics include improvements in spectral band adjustment factors, desert calibration, and homogenization of data records.

David Doelling↗

Additional Characterization of Sonoran Pics in Support of A Stable Multi-Sensor Geostationary Imager Record

The Sonoran Desert is the most utilized Pseudo Invariant Calibration Site (PICS) located in the Americas for post-launch radiometer drift monitoring and sensor pair radiometric scaling. The Sonoran Desert is located near the US Arizona and Mexican border with an elevation of 37 m. The site has small spatial and angular variations; however, soil moisture can cause short- term periodic reflectance fluctuations. The NASA Clouds and the Earth’s Radiant Energy System (CERES) project utilizes the site to validate the GOES East and West imager calibration coefficients derived from inter-calibrating GOES with MODIS. Because the daily local noon angular solar and viewing angles repeat every year over the site, a daily exoatmospheric radiance model (DERM) can be constructed over the lifetime of a well-calibrated GOES sensor. DERM based on a well-calibrated GOES imager can then be used to determine the calibration coefficients of successive GOES imagers to provide a stable multi-sensor GOES imager record. This will ensure that the GOES retrieved clouds and derived broadband fluxes can be used to infer the regional diurnal cycle in between Terra and Aqua CERES measurements to accurately compute the daily mean regional fluxes and clouds over the 20-year CERES SYN1deg product. Although the Sonoran Desert surface reflectance and atmospheric column vary seasonally, the inter-annual variability of the seasonal cycle is small, but it adds noise to the resulting DERM calibration coefficients. We seek to reduce the uncertainty of the DERM approach by improving the clear-sky filtering and correlating the observed interannual reflectance variability with atmospheric parameters, such as precipitable water, ozone concentration, and aerosol optical depth. The additional characterization of the Sonoran Desert site DERM for both the GOES East and West positions should improve the accuracy of the CERES SYN1deg product clouds and fluxes.

Prathana Khakurel↗

Evaluation of Radiometric Performance of CERES Instruments Aboard Terra

The Terra satellite platform carries the first two flight models of the Clouds and the Earth’s Radiant Energy System, which make radiometric measurements of the Earth to examine the roles of cloud feedback and radiation balance in the Earth System. The Terra-borne instruments use three channels: the shortwave (0.2 - 5 µm), total (0.2 – 100 µm) and window (8 – 12 µm), which are calibrated using an onboard internal calibration module to track the long-term stability of each channel. Observed measurements are converted to top-of-atmosphere radiances by accounting for the instrument optics and detector sensitivity coefficients determined from prelaunch calibrations. Trends in the instrument’s radiometric performance determined through on-orbit calibrations and vicarious studies were applied, and these corrections have shown to produce a stable data record of radiative fluxes over the lifetime of the mission. Changes in instrument observations and new methods to account for them as a result of the discontinuation of station keeping for Terra will be discussed.

Alexander Jarnot↗

MOBY, A Radiometric Buoy for Performance Monitoring and Vicarious Calibration of Satellite Ocean Color Sensors: Measurement and Data Analysis Protocols

The Marine Optical Buoy (MOBY) is the centerpiece of the primary ocean measurement site for calibration of satellite ocean color sensors based on independent in situ measurements. Since late 1996, the time series of normalized water-leaving radiances L(sub WN)(lambda) determined from the array of radiometric sensors attached to MOBY are the primary basis for the on-orbit calibrations of the USA Sea-viewing Wide Field-of-view Sensor (SeaWiFS), the Japanese Ocean Color and Temperature Sensor (OCTS), the French Polarization Detection Environmental Radiometer (POLDER), the German Modular Optoelectronic Scanner on the Indian Research Satellite (IRS1-MOS), and the USA Moderate Resolution Imaging Spectrometer (MODIS). The MOBY vicarious calibration L(sub WN)(lambda) reference is an essential element in the international effort to develop a global, multi-year time series of consistently calibrated ocean color products using data from a wide variety of independent satellite sensors. A longstanding goal of the SeaWiFS and MODIS (Ocean) Science Teams is to determine satellite-derived L(sub WN)(labda) with a relative combined standard uncertainty of 5 %. Other satellite ocean color projects and the Sensor Intercomparison for Marine Biology and Interdisciplinary Oceanic Studies (SIMBIOS) project have also adopted this goal, at least implicitly. Because water-leaving radiance contributes at most 10 % of the total radiance measured by a satellite sensor above the atmosphere, a 5 % uncertainty in L(sub WN)(lambda) implies a 0.5 % uncertainty in the above-atmosphere radiance measurements. This level of uncertainty can only be approached using vicarious-calibration approaches as described below. In practice, this means that the satellite radiance responsivity is adjusted to achieve the best agreement, in a least-squares sense, for the L(sub WN)(lambda) results determined using the satellite and the independent optical sensors (e.g. MOBY). The end result of this approach is to implicitly absorb unquantified, but systematic, errors in the atmospheric correction, incident solar flux, and satellite sensor calibration into a single correction factor to produce consistency with the in situ data.

Clark, Dennis K.↗

Absolute Radiometric Calibration of Narrow-Swath Imaging Sensors with Reference to Non-Coincident Wide-Swath Sensors

An inter-calibration method is developed to provide absolute radiometric calibration of narrow-swath imaging sensors with reference to non-coincident wide-swath sensors. The method predicts at-sensor radiance using non-coincident imagery from the reference sensor and knowledge of spectral reflectance of the test site. The imagery of the reference sensor is restricted to acquisitions that provide similar view and solar illumination geometry to reduce uncertainties due to directional reflectance effects. Spectral reflectance of the test site is found with a simple iterative radiative transfer method using radiance values of a well-understood wide-swath sensor and spectral shape information based on historical ground-based measurements. At-sensor radiance is calculated for the narrow-swath sensor using this spectral reflectance and atmospheric parameters that are also based on historical in situ measurements. Results of the inter-calibration method show agreement on the 2 5 percent level in most spectral regions with the vicarious calibration technique relying on coincident ground-based measurements referred to as the reflectance-based approach. While the variability of the inter-calibration method based on non-coincident image pairs is significantly larger, results are consistent with techniques relying on in situ measurements. The method is also insensitive to spectral differences between the sensors by transferring to surface spectral reflectance prior to prediction of at-sensor radiance. The utility of this inter-calibration method is made clear by its flexibility to utilize image pairings with acquisition dates differing in excess of 30 days allowing frequent absolute calibration comparisons between wide- and narrow-swath sensors.

McCorkel, Joel↗

Spectral Polarization Distribution Models (PDMs) for NASA CLARREO Pathfinder’s Inter-Calibration Applications

Solar radiation scattered by Earth surfaces of various scene types such as oceans, deserts, tree leaves etc and atmospheric molecules and particles is polarized and the amount of polarization depends on the surface composition and particle physical properties. This can be a source of measurement errors in satellite data if a non-polarimetric radiometric sensor is sensitive to the polarization state of light. To obtain highly accurate spectral solar radiation data from the Earth-atmosphere system for the space-borne inter-calibration studies as proposed in NASA's Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission and the CLARREO Pathfinder (CPF) mission, the spectral polarization state of the reflected solar light at the top of atmosphere (TOA) must be known with sufficient accuracy. The degree of polarization (DOP) and the angle of linear polarization (AOLP) of the light at the TOA as functions of incident and viewing geometry and scene type construct the Polarization Distribution Models (PDMs) for correction of polarization-induced error of satellite data. In this work, algorithms for modeling the spectral polarization state of reflected sunlight from various types of Earth, including oceans, deserts, vegetated land surfaces and these scene types with all kinds of clouds, are developed. By comparing the model results with the PARASOL satellite data, our numerical results demonstrate that the model can provide a reliable approach for making the spectral PDMs for wavelengths between 320 and 2300 nm for satellite inter-calibration applications as proposed in the CLARREO and the CLARREO CPF missions.

Sun, Wenbo↗

Calibration analysis for a multi-channel infrared scanning radiometer

A procedure for calibrating an infrared scanning spectroradiometer by a computerized parametric error analysis technique was developed. The uncertainties in the radiometric measurements of scene radiance and (for the case of a blackbody scene) temperature due to possible uncertainties in the calibration target temperature, calibration target emissivity, and instrument temperature were calculated for a range of uncertainty levels in the parameters, as well as for a gamut of scent temperatures corresponding to a given spectral channel. This technique is applicable to the radiometric calibration of any infrared radiometer. It was applied specifically to the Cloud-Top Scanning (C.T.S) Radiometer, a three-channel instrument designed for aircraftborne cloud radiance measurements in the 6.75 and 11.5 micron thermal emission spectral regions.

Walden, H.↗

Status of Terra and Aqua MODIS Instruments

Currently, two nearly identical MODIS instruments are operating in space: one on the Terra spacecraft launched in December 1999 and another on the Aqua spacecraft launched in May 2002. MODIS has 36 spectral bands with wavelengths covering from visible (VIS) to long-wave infrared (LWIR). Since launch, MODIS observations and data products have contributed significantly to studies of changes in the Earth system of land, oceans, and atmosphere. To maintain its on-orbit calibration and data product quality, MODIS was built with a comprehensive set of on-board calibrators, consisting of a solar diffuser (SD) and a solar diffuser stability monitor (SDSM) for the reflective solar bands (RSB) and an on-board blackbody (BB) for the thermal emissive bands (TEB). Both instruments have demonstrated good performance. The primary Level 1 B (LIB) data products are top of the atmosphere (TOA) reflectance for RSB and radiance for TEB This paper provides an overview of MODIS calibration methodologies, activities, lifetime on-orbit performance and challenging issues for each MODIS, the impact on LIB product quality, and lessons learned for future sensors such as the NPOESS VIIRS.

Xiong, Xiaoxiong↗

Calibration and Characterization of the NASA EOS Terra and Aqua MODIS Instruments

The Moderate Resolution Imaging Spectroradiometer (MODIS) instrument is operating on both of the Terra and Aqua missions within the NASA Earth Observing System (EOS). The Terra MODIS instrument began taking observations in February 2000 and the Aqua MODIS instrument began taking observations in June of 2002 and both continue to operate successfully up to the present time. The MODIS instrument scans the entire Earth every 24 hours at nominal spatial resolutions between 250 and 1000 meters. It has 36 spectral bands spanning the electromagnetic spectrum from the visible wavelengths mar 400 micrometers to the emissive thermal infrared wavelengths at 15 micrometers. The MODIS instruments produce approximately 40 geophysical products devoted to observing land, ocean, and atmospheric processes and trends. To meet the scientific objectives associated with the NASA Earth sciences efforts the MODIS instruments must be and have been carefully calibrated and the performance characterized to meet specifications and goals such as five percent radiance and two percent relative to the sun accuracy in the twenty bands providing reflected solar radiation observations and one percent radiance accuracy in the sixteen bands observing in the thermal infrared. Over the time spanning instrument development and the pre-launch calibration and characterization of the instrument through the years of operation in space, the performance of the MODIS instruments have changed in multiple ways and appropriate adjustments made in relevant algorithms and look-up tables necessary to produce observations that meet the scientific objectives and requirements. The changes have been quantified and accounted for through careful use of on-board calibration devices such as the Spectro-Radiometric Calibration Assembly (SRCA), the Solar Diffuser (SD) and its companion Solar Diffuser Stability Monitor (SDSM), deep-space and lunar observations, and calibration targets on the Earth's surface. The strictest and most difficult challenges have come in trying to meet the requirements for observing Ocean color and related ocean biology processes over time and space. Overall the MODIS observations have been very successful in providing valuable scientific and applications results. The essential capabilities of MODIS are to be provided in the future by the Visible and Infrared Imaging Radiometer Suite (VIIRS) on the National Polar Orbiting Environmental Satellite Series (NPOESS).

Salomonson, Vincent V.↗

Analysis of AIS radiometry with emphasis on determination of atmospheric properties and surface reflectance

Airborne Imaging Spectrometer data from Mono Lake, California, were studied in order to establish spectral radiance of test areas under solar illumination. The objective is to provide a method of atmospheric correction for major absorbers from the spectrometer data themselves. Crucial to the analysis is radiometric calibration of the instrument. Good agreement is found between calculated and measured radiances for uniform surface targets (beaches), but simulations of atmospheric properties with LOWTRAN lead to unreasonably low values of atmospheric precipitable water. Absorptions from carbon dioxide are not detected in the AIS data, but are strongly present in the LOWTRAN model. The apparent low contrast of all atmospheric absorption bands leads to a study of contamination from overlapping spectral orders in the AIS data. The suspected contamination is shown unambiguously to be present beyond approximately 1500 nm and consists of an extra radiance term including atmospheric bands from the delta/2 wavelength interval. A rigorous removal of the unwanted spectral contamination does not seem possible for any data taken in the rock mode. Rough estimates for tree-mode observations might be pieced together is a suitable after-the-fact radiometric claibration of the instrument can be formulated.

Conel, J. E.↗