Search NASA⌕ Search

SEARCH · Search NASA

Results for “segmentation averaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Molecular Accumulation during JWST’s Optical Telescope Cryogenic Thermal Vacuum Testing

Maintaining molecular cleanliness during the JWST’s Optical Telescope/Instrument Module (OTIS) Cryogenic Thermal Vacuum (TV) test campaign was critical to the success of its optical mission on orbit. In the thermal vacuum tests leading up to the final cryogenic test to validate the OTIS flight hardware, NASA Johnson Space Center’s (JSC’s) TV Chamber A was fully characterized for molecular contamination. It was found to contain common volatile condensable materials (VCM), including hydrocarbons, plasticizers, and silicones, all of which absorb in JWST’s infrared wavelength region. Due to the risks involved, cleaning molecular contamination from the OTIS mirrors was not an option and heating the Primary Mirror (PM) segments would have also been a risky and expensive endeavor. As a result, a monitoring process was developed and implemented during four different Pathfinder or risk reduction tests that were scheduled to occur prior to the flight hardware test. The goal was to quantify and assess the risk of molecular contamination depositing on the PM resulting from relatively warm chamber shrouds “leading” colder PM mirrors during warmup, by a margin of 10-50 Kelvin (K). This was accomplished using Cryogenic Quartz Crystal Microbalances (CQCMs), held at temperatures slightly cooler than the segments to signal the onset of contamination events. Per the JWST Contamination Control Plan (CCP)1, the total Primary Mirror molecular allocation requirement was 50 angstroms. In all tests, the results showed an average accumulated molecular contamination of <10 angstroms.

optics↗

Molecular Accumulation during JWST’s Optical Telescope Cryogenic Thermal Vacuum Testing

Maintaining molecular cleanliness during the JWST’s Optical Telescope/Instrument Module (OTIS) Cryogenic Thermal Vacuum (TV) test campaign was critical to the success of its optical mission on orbit. In the thermal vacuum tests leading up to the final cryogenic test to validate the OTIS flight hardware, NASA Johnson Space Center’s (JSC’s) TV Chamber A was fully characterized for molecular contamination. It was found to contain common volatile condensable materials (VCM), including hydrocarbons, plasticizers, and silicones, all of which absorb in JWST’s infrared wavelength region. Due to the risks involved, cleaning molecular contamination from the OTIS mirrors was not an option and heating the Primary Mirror (PM) segments would have also been a risky and expensive endeavor. As a result, a monitoring process was developed and implemented during four different Pathfinder or risk reduction tests that were scheduled to occur prior to the flight hardware test. The goal was to quantify and assess the risk of molecular contamination depositing on the PM resulting from relatively warm chamber shrouds “leading” colder PM mirrors during warmup, by a margin of 10-50 Kelvin (K). This was accomplished using Cryogenic Quartz Crystal Microbalances (CQCMs), held at temperatures slightly cooler than the segments to signal the onset of contamination events. Per the JWST Contamination Control Plan (CCP)1, the total Primary Mirror molecular allocation requirement was 50 angstroms. In all tests, the results showed an average accumulated molecular contamination of <10 angstroms.

molecular, contamination, thermal vacuum, cryogeni↗

Fast automatic 3D liver segmentation based on a three-level AdaBoost-guided active shape model

Purpose: A robust, automatic, and rapid method for liver delineation is urgently needed for the diagnosis and treatment of liver disorders. Until now, the high variability in liver shape, local image artifacts, and the presence of tumors have complicated the development of automatic 3D liver segmentation. In this study, an automatic three-level AdaBoost-guided active shape model (ASM) is proposed for the segmentation of the liver based on enhanced computed tomography images in a robust and fast manner, with an emphasis on the detection of tumors. Methods: The AdaBoost voxel classifier and AdaBoost profile classifier were used to automatically guide three-level active shape modeling. In the first level of model initialization, fast automatic liver segmentation by an AdaBoost voxel classifier method is proposed. A shape model is then initialized by registration with the resulting rough segmentation. In the second level of active shape model fitting, a prior model based on the two-class AdaBoost profile classifier is proposed to identify the optimal surface. In the third level, a deformable simplex mesh with profile probability and curvature constraint as the external force is used to refine the shape fitting result. In total, three registration methods—3D similarity registration, probability atlas B-spline, and their proposed deformable closest point registration—are used to establish shape correspondence. Results: The proposed method was evaluated using three public challenge datasets: 3Dircadb1, SLIVER07, and Visceral Anatomy3. The results showed that our approach performs with promising efficiency, with an average of 35 s, and accuracy, with an average Dice similarity coefficient (DSC) of 0.94 ± 0.02, 0.96 ± 0.01, and 0.94 ± 0.02 for the 3Dircadb1, SLIVER07, and Anatomy3 training datasets, respectively. The DSC of the SLIVER07 testing and Anatomy3 unseen testing datasets were 0.964 and 0.933, respectively. Conclusions: The proposed automatic approach achieves robust, accurate, and fast liver segmentation for 3D CTce datasets. The AdaBoost voxel classifier can detect liver area quickly without errors and provides sufficient liver shape information for model initialization. The AdaBoost profile classifier achieves sufficient accuracy and greatly decreases segmentation time. These results show that the proposed segmentation method achieves a level of accuracy comparable to that of state-of-the-art automatic methods based on ASM.

60 APPLIED LIFE SCIENCES↗

Transport in Random Media With Inhomogeneous Mixing Statistics

The Levermore-Pomraning (LP) model has been investigated for use in implicit Monte Carlo (IMC) algorithms to describe thermal photon transport computations in stochastically mixed cells with material energy coupling. For purely absorbing non-emitting materials, the LP-model is known to predict the exact material averaged fluxes when the mixing statistics are Markovian. In the presence of scattering or reemmission, or if the mixing is non-Markovian, the LP-model is approximate and has greatly diminished accuracy for optically thick, highly scattering materials. Nevertheless, the model enables a robust extension of the simple atomic mix approximation to accommodate spatial correlation effects through well characterized parameters such as mean chord lengths. In this work, we construct exact analytical solutions of the LP-equations for piecewise constant spatial variation of the material chord lengths. It is not possible in general to obtain closed form solutions when the chord lengths are continuous functions of space, although we briefly examine special conditions under which this is feasible. However, by allowing an arbitrarily fine spatial segmentation of the medium it is possible to construct highly refined solutions to fit desired spatial chord length profiles. Material volume fractions that are consistent with the chord lengths are first constructed by solving the associated Chapmann-Kolmogorov equations and applied to obtain the material averaged fluxes in two settings: when the materials are purely absorbing, and when scattering is present in rod model geometry. Illustrative numerical results for the volume fractions and material averaged fluxes are obtained by implementing the algorithms in MATLAB for spatially linear and quadratic variations of the chord lengths.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New velocimetry and revised cartography of the spiral arms in the Milky Way—a consistent symbiosis

Recent advances in the determinations of the positions (pitch angle, shape, numbers, interarm separation) and velocities (rotation curve) of the spiral arms are evaluated and compared to previous determinations. Based on these results, an average cartographic model is developed that fits the means of basic input data and provides predictions for the locations of the arms in the Milky Way, for each galactic quadrant. For each spiral arm segment in each galactic quadrant, the LSR radial velocities are calculated for the radial distance as well as for its galactic longitude. From our velocimetric model, arm intercepts (between line of sights and spiral arms) are indicated in velocity space and may be used to find the distance and velocity to any arm, in a given longitude range. Velocity comparisons between model predictions and published CO velocity distribution are done for each galactic quadrant, with good results. Our velocimetric model is not hydromagnetic in character, nor is it a particle-simulation scheme, yet it is simple to use for comparisons with the observations and it is in symbiosis and consistent with our cartographic model (itself simple to use for comparisons with observations). A blending in velocity of the Perseus and Cygnus arms is further demonstrated, as well as an apparent longitude-velocity blending of the starting points of the four spiral arms near 4 kpc (not a physical ring). An integrated (distance, velocity) model for the mass in the disk is employed, to yield the total mass of 3.0 × 10{sup 11} M{sub ☉} within a galactic radius of 28 kpc.

79 ASTRONOMY AND ASTROPHYSICS↗

A method for determining the weak statistical stationarity of a random process

A method for determining the weak statistical stationarity of a random process is presented. The core of this testing procedure consists of generating an equivalent ensemble which approximates a true ensemble. Formation of an equivalent ensemble is accomplished through segmenting a sufficiently long time history of a random process into equal, finite, and statistically independent sample records. The weak statistical stationarity is ascertained based on the time invariance of the equivalent-ensemble averages. Comparison of these averages with their corresponding time averages over a single sample record leads to a heuristic estimate of the ergodicity of a random process. Specific variance tests are introduced for evaluating the statistical independence of the sample records, the time invariance of the equivalent-ensemble autocorrelations, and the ergodicity. Examination and substantiation of these procedures were conducted utilizing turbulent velocity signals.

Sadeh, W. Z.↗

On the Quality of the Nimbus 7 LIMS Version 6 Water Vapor Profiles and Distributions

This report describes the quality of the Nimbus 7 Limb Infrared Monitor of the Stratosphere (LIMS) water vapor (H2O) profiles of 1978/79 that were processed with a Version 6 (V6) algorithm and archived in 2002. The V6 profiles incorporate a better knowledge of the instrument attitude for the LIMS measurements along its orbits, leading to improvements for its temperature profiles and for the registration of its water vapor radiances with pressure. As a result, the LIMS V6 zonal-mean distributions of H2O exhibit better hemispheric symmetry than was the case from the original Version 5 (V5) dataset that was archived in 1982. Estimates of the precision and accuracy of the V6 H2O profiles are developed and provided. Individual profiles have a precision of order 5% and an estimated accuracy of about 19% at 3 hPa, 14% at 10 hPa, and 26% at 50 hPa. Profile segments within about 2 km of the tropopause are often affected by emissions from clouds that appear in the finite field-of-view of the detector for the LIMS H2O channel. Zonally-averaged distributions of the LIMS V6 H2O are compared with those from the more recent Microwave Limb Sounder (MLS) satellite experiment for November, February, and May of 2004/2005. The patterns and values of their respective distributions are similar in many respects. Effects of a strengthened Brewer-Dobson circulation are indicated in the MLS distributions of the recent decade versus those of LIMS from 1978/79. A tropical tape recorder signal is present in the 7-month time series of LIMS V6 H2O with lowest values in February 1979, and the estimated, annually-averaged "entry-level" H2O is 3.5 to 3.8 ppmv. It is judged that this historic LIMS water vapor dataset is of good quality for studies of the near global-scale chemistry and transport for pressure levels from 3 hPa to about 70 to 100 hPa.

Remsberg, E. E.↗

Hydrodissection of the Gallbladder Bed: A Technique for Ablations Located Close to the Gallbladder

Objective: To report the technique of hydrodissection of the gallbladder bed, in order to separate the gallbladder wall from the liver surface during microwave ablation of liver malignancies located in segment V. Materials and Methods: Between January 2018 and March 2018, percutaneous hydrodissection of the gallbladder fossa was performed during four microwave ablation procedures in three patients (One patient was treated twice for the same lesion, making a total of four procedures for three lesions.) All treated lesions were located in segment V and abutting the gallbladder. Number of hydrodissection needles, volume of hydrodissection, repartition of hydrodissection, separation of tumour from the gallbladder post-hydrodissection, technical success of hydrodissection/ablation, and complications were recorded and evaluated. Results: Hydrodissection of the gallbladder fossa was technically feasible in all four procedures, and microwave ablation was performed at maximum power without any early interruption. Time to perform hydrodissection was 11.3 min on average (range 7–18 min). Minimal distance between the ablation area and the GB increased from virtual to 10 mm on average (range 6–13), with a mean volume of dissection of 65 ml (range 40–100). Technical success was 75%. There was no complication related to the hydrodissection itself, and no acute or delayed gallbladder complication. Conclusion: Hydrodissection of the gallbladder bed is a feasible technique to separate the gallbladder from the liver surface. This could potentially decrease the risk of thermal injuries to the gallbladder wall when ablating tumours located in segment V.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Verification of Accuracy of CyberKnife Tumor-tracking Radiation Therapy Using Patient-specific Lung Phantoms

Purpose: To investigate the accuracy of the CyberKnife Xsight Lung Tracking System (XLTS) compared with that of a fiducial-based target tracking system (FTTS) using patient-specific lung phantoms. Methods and Materials: Three-dimensional printing technology was used to make individualized lung phantoms that closely mimicked the lung anatomy of actual patients. Based on planning computed tomographic data from 6 lung cancer patients who underwent stereotactic ablative radiation therapy using the CyberKnife, the volume above a certain Hounsfield unit (HU) was assigned as the structure to be filled uniformly with polylactic acid material by a 3-dimensional printer (3D Edison, Lokit, Korea). We evaluated the discrepancies between the measured and modeled target positions, representing the total tracking error, using 3 log files that were generated during each treatment for both the FTTS and the XLTS. We also analyzed the γ index between the film dose measured under the FTTS and XLTS. Results: The overall mean values and standard deviations of total tracking errors for the FTTS were 0.36 ± 0.39 mm, 0.15 ± 0.64 mm, and 0.15 ± 0.62 mm for the craniocaudal (CC), left–right (LR), and anteroposterior (AP) components, respectively. Those for the XLTS were 0.38 ± 0.54 mm, 0.13 ± 0.18 mm, and 0.14 ± 0.37 mm for the CC, LR, and AP components, respectively. The average of γ passing rates was 100% for the criteria of 3%, 3 mm; 99.6% for the criteria of 2%, 2 mm; and 86.8% for the criteria of 1%, 1 mm. Conclusions: The XLTS has segmentation accuracy comparable with that of the FTTS and small total tracking errors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of governing factors controlling gas transport through fresh and aged triptycene-based polyimide films

In this report the fundamental gas transport properties and physical aging behavior of a series of triptycene-based polyimides with various substitution groups were investigated. Wide-angle x-ray diffraction revealed that the 6FDA-1,4-triptycene polyimides exhibit two chain packing domains with d-spacing values of ~6.7 Å and ~5.3 Å, corresponding to triptycene-induced chain packing disruption and chain segments lacking the triptycene moiety, respectively. Positron annihilation lifetime spectroscopy (PALS) showed a bimodal distribution of microcavity size made up of triptycene cleft cavities that are ~3 Å diameter and larger interchain cavities with an average diameter of ~7 Å. Additionally, PALS confirmed 6FDA-1,4-trip_CH 3 has the lowest fractional free volume, primarily due to smaller contributions from the interchain cavities, and 6FDA-1,4-trip_CF 3 has the largest fractional free volume. It was also found that the addition of substituent groups had a unique and positive effect on the aging properties over nine months, in which the addition of CH 3 and CF 3 groups led to permeability increases of ~20% and ~40%, respectively. This is caused by the combination of the lowered driving force for physical aging, the substituent groups sterically hindering tighter packing with time, and the interconnectivity and/or unblocking of free volume over time through small-scale, local chain motion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The south-central United States magnetic anomaly

A positive magnetic anomaly, which dominates the MAGSAT scalar field over the south-central United States, results from the superposition of magnetic effects from several geologic sources and tectonic structures in the crust. The highly magnetic basement rocks of this region show good correlation with increased crustal thickness, above average crustal velocity and predominantly negative free-air gravity anomalies, all of which are useful constraints for modeling the magnetic sources. The positive anomaly is composed of two primary elements. The western-most segment is related to middle Proterozoic granite intrusions, rhyolite flows and interspersed metamorphic basement rocks in the Texas panhandle and eastern New Mexico. The anomaly and the magnetic crust are bounded to the west by the north-south striking Rio Grande Rift. The anomaly extends eastward over the Grenville age basement rocks of central Texas, and is terminated to the south and east by the buried extension of the Ouachita System. The northern segment of the anomaly extends eastward across Oklahoma and Arkansas to the Mississippi Embayment. It corresponds to a general positive magnetic region associated with the Wichita Mountains igneous complex in south-central Oklahoma and 1.2 to 1.5 Ga. felsic terrane to the north.

Starich, P. J.↗

Evolution of Vapor Bubbles Nucleation Sites in Low Gravity

When liquid is expelled by a vapor bubble growing at a nucleation site on a superheated surface, a thin microlayer underneath the bubble is left behind. It is evaporated from the free microlayer surface that provides for bubble growth. The average thickness of the microlayer determining the evaporation rate increases with time if the latter does not exceed a threshold value associated with the burn-out crisis. The bubble is described as a spherical segment with its flattened part adjoining the microlayer. This introduces two independent variables - the radius of the spherical part of the bubble surface and the polar angle that defines the relative area of the flattened part. They are to be found out from a set of two strongly nonlinear equations resulting from mass and momentum conservation laws. The first one depends on both microlayer thickness and nonmonotonously changing bubble base area. The second involves two major factors favoring bubble detachment - the buoyancy and a force due to the initial momentum of vapor input into the bubble. The former force depends on gravity whereas the latter one does not. It is why the limiting regimes of bubble evolution that correspond to normal or moderately reduced gravity and to microgravity feature drastically different properties. In the first case, the buoyancy dominates and the bubble evolves in such a manner as to become a full sphere at a moment that can be viewed as that of detachment. The detachment volume grows as gravity decreases. In the second case, the buoyancy is negligible and the bubble stays near the surface, while its volume continues to increase for a sufficiently long time. The findings are discussed in connection with experimental data obtained under different gravity conditions, some unpublished experiments being included. They help to understand why the pool boiling heat transfer coefficient frequently increases as gravity falls down and eventually vanishes.

Buyevich, Yu A.↗

Dosimetric comparison of different multileaf collimator leaves in treatment planning of intensity-modulated radiotherapy for cervical cancer

To study the effect of multileaf collimator (MLC) leaf widths (standard MLC [sMLC] width of 10 mm and micro-MLC [mMLC] width of 4 mm) on intensity-modulated radiotherapy (IMRT) for cervical cancer. Between January 2010 and August 2010, a retrospective analysis was conducted on 12 patients with cervical cancer. The treatment plans for all patients were generated with the same machine setup parameters and optimization methods in a treatment planning system (TPS) based on 2 commercial Elekta MLC devices. The dose distribution for the planning tumor volume (PTV), the dose sparing for organs at risk (OARs), the monitor units (MUs), and the number of IMRT segments were evaluated. For the delivery efficiency, the MUs were significantly higher in the sMLC-IMRT plan than in the mMLC-IMRT plan (802 ± 56.9 vs 702 ± 56.7; p < 0.05). The number of segments in the plans were 58.75 ± 1.8 and 59 ± 1.04 (p > 0.05). For the planning quality, the conformity index (CI) between the 2 paired IMRT plans with the mMLC and the sMLC did not differ significantly (average: 0.817 ± 0.024 vs 0.810 ± 0.028; p > 0.05). The differences of the homogeneity index (HI) between the 2 paired plans were statistically significant (average: 1.122 ± 0.010 vs 1.132 ± 0.014; p < 0.01). For OARs, the rectum, bladder, small intestine, and bony pelvis were evaluated in terms of V{sub 10}, V{sub 20}, V{sub 30}, and V{sub 40}, percentage of contoured OAR volumes receiving 10, 20, 30, and 40 Gy, respectively, and the mean dose (D{sub mean}) received. The IMRT plans with the mMLC protected the OARs better than the plans with the sMLC. There were significant differences (p < 0.05) in evaluated parameters between the 2 paired IMRT plans, except for V{sub 30} and V{sub 40} of the rectum and V{sub 10}, V{sub 20}, V{sub 40}, and D{sub mean} of the bladder. IMRT plans with the mMLC showed advantages over the plans with the sMLC in dose homogeneity for targets, dose sparing of OARs, and fewer MUs in cervical cancer.

61 RADIATION PROTECTION AND DOSIMETRY↗

CHARACTERIZING COMPLEXITY IN SOLAR MAGNETOGRAM DATA USING A WAVELET-BASED SEGMENTATION METHOD

The multifractal nature of solar photospheric magnetic structures is studied using the two-dimensional wavelet transform modulus maxima (WTMM) method. This relies on computing partition functions from the wavelet transform skeleton defined by the WTMM method. This skeleton provides an adaptive space-scale partition of the fractal distribution under study, from which one can extract the multifractal singularity spectrum. We describe the implementation of a multiscale image processing segmentation procedure based on the partitioning of the WT skeleton, which allows the disentangling of the information concerning the multifractal properties of active regions from the surrounding quiet-Sun field. The quiet Sun exhibits an average Hoelder exponent {approx}-0.75, with observed multifractal properties due to the supergranular structure. On the other hand, active region multifractal spectra exhibit an average Hoelder exponent {approx}0.38, similar to those found when studying experimental data from turbulent flows.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A System for Dosage-Based Functional Genomics in Poplar

Altering gene dosage through variation in gene copy number is a powerful approach to addressing questions regarding gene regulation, quantitative trait loci, and heterosis, but one that is not easily applied to sexually transmitted species. Elite poplar (Populus spp) varieties are created through interspecific hybridization, followed by clonal propagation. Altered gene dosage relationships are believed to contribute to hybrid performance. Clonal propagation allows for replication and maintenance of meiotically unstable ploidy or structural variants and provides an alternative approach to investigating gene dosage effects not possible in sexually propagated species. Here, we built a genome-wide structural variation system for dosage-based functional genomics and breeding of poplar. We pollinated Populus deltoides with gamma-irradiated Populus nigra pollen to produce >500 F1 seedlings containing dosage lesions in the form of deletions and insertions of chromosomal segments (indel mutations). Using high-precision dosage analysis, we detected indel mutations in ~55% of the progeny. These indels varied in length, position, and number per individual, cumulatively tiling >99% of the genome, with an average of 10 indels per gene. Combined with future phenotype and transcriptome data, this population will provide an excellent resource for creating and characterizing dosage-based variation in poplar, including the contribution of dosage to quantitative traits and heterosis.

59 BASIC BIOLOGICAL SCIENCES↗

SU-F-T-345: Quasi-Dead Beams: Clinical Relevance and Implications for Automatic Planning

Purpose: Beam direction selection for fixed-beam IMRT planning is typically a manual process. Severe dose-volume limits on critical structures in the thorax often result in atypical selection of beam directions as compared to other body sites. This work demonstrates the potential consequences as well as clinical relevance. Methods: 21 thoracic cases treated with 5–7 beam directions, 6 cases including non-coplanar arrangements, with fractional doses of 150–411cGy were analyzed. Endpoints included per-beam modulation scaling factor (MSF), variation from equal weighting, and delivery QA passing rate. Results: During analysis of patient-specific delivery QA a sub-standard passing rate was found for a single 5-field plan (90.48% of pixels evaluated passing 3% dose, 3mm DTA). During investigation it was found that a single beam demonstrated a MSF of 34.7 and contributed only 2.7% to the mean dose of the target. In addition, the variation from equal weighting for this beam was 17.3% absolute resulting in another beam with a MSF of 4.6 contributing 41.9% to the mean dose to the target; a variation of 21.9% from equal weighting. The average MSF for the remaining 20 cases was 4.0 (SD 1.8) with an average absolute deviation of 2.8% from equal weighting (SD 3.1%). Conclusion: Optimization in commercial treatment planning systems typically results in relatively equally weighted beams. Extreme variation from this can result in excessively high MSFs (very small segments) and potential decreases in agreement between planned and delivered dose distributions. In addition, the resultant beam may contribute minimal dose to the target (quasi-dead beam); a byproduct being increased treatment time and associated localization uncertainties. Potential ramifications exist for automatic planning algorithms should they allow for user-defined beam directions. Additionally, these quasi-dead beams may be embedded in the libraries for model-based systems potentially resulting in inefficient and less accurate deliveries.

60 APPLIED LIFE SCIENCES↗

X-ray spectral and temporal analysis of narrow line Seyfert 1 galaxy Was 61

We present an analysis of spectrum and variability of the bright reddened narrow line Seyfert 1 galaxy Was 61 using 90 ks archival XMM-Newton data. The X-ray spectrum in 0.2–10 keV can be characterized by an absorbed power-law plus soft excess and an Fe Kα emission line. The power-law spectral index remains constant during the flux variation. The absorbing material is mildly ionized, with a column density of 3.2 × 10{sup 21} cm{sup −2}, and does not appear to vary during the period of the X-ray observation. If the same material causes the optical reddening (E(B–V) ≃ 0.6 mag), it must be located outside the narrow line region with a dust-to-gas ratio similar to the average Galactic value. We detect significant variations of the Fe Kα line during the observational period. A broad Fe Kα line at ≃6.7 keV with a width of ∼0.6 keV is detected in the low flux segment of the first 40 ks exposure, and is absent in the spectra of other segments; a narrow Fe Kα emission line ∼6.4 keV with a width of ∼0.1 keV is observed in the subsequent 20 ks segment, which has a count rate 35% higher and is in the next day. We believe this is due to the change in geometry and kinematics of the X-ray emitting corona. The temperature and flux of soft X-ray excess appear to correlate with the flux of the hard power-law component. Comptonization of disc photons by a warm and optically thick inner disk is preferred to interpret the soft excess, rather than the ionized reflection.

79 ASTRONOMY AND ASTROPHYSICS↗

Compressional features in the Tharsis Region of Mars: Orientations and Timing of Deformation

The Tharsis ridge system appears to form a great circle around the major volcanoes. The roughly circumferential orientation of these ridges could be interpreted as the formation of a ridge system in response to a single stress field with a center near Pavonis Mons. Wise, et al. (1979) plotted the perpendiculars to strikes of ridges on the eastern flanks of Tharsis as great circles on the upper hemisphere of an equal area net. In order to further test for circular symmetry and possible other influences on ridge orientations, normals to vector means of ridge orientations were calculated using over 1850 digitized ridge segments sampled in 10 degree boxes. Orientations of individual ridge segments were weighted by their lengths, and the magnitudes of normals to vectors means were weighted by cummulative length of the ridge segments. Normals to vector means with magnitudes less than 100 km are not shown. Assuming a single fold origin for ridges, the resulting plot shows compressive stress trajectories for the ridges in the Tharsis region. The averaged compressive stress orientation around Tharsis confirm the suggestion by Wise, et al. that the ridge system is not concentric to any single point.

Watters, T. R.↗