Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Structural Modification of Starch Nanoparticles Via Graft Copolymerization Using KMnO{sub 4}, HClO{sub 4} and HNO{sub 3} Redox Pair

The novelty addressed here is commenced with a view to use our formerly prepared starch nanoparticles (SNPs) of size around 80–100 nm as a starting substrate for grafting meth acrylic acid (MAA) using KMnO{sub 4}, HClO{sub 4} in presence of HNO{sub 3} as innovative redox pair in aqueous medium. This was done to see the effect of SNPs with respect to well-dispersed nanosized particles, large surface areas, biodegradability and reactivity on the rate and extent of grafting. Besides; maximize the graft yield and graft reaction efficiency and reduce the homopolymer formation to lower extent. This could be accomplished via an in-depth assessment into the chief factors affecting the polymerization reaction such as initiator, monomer, SNPs and acid concentrations, time and temperature of polymerization, and liquor ratio. The results obtained indicate that the magnitude of the polymer yield including graft yield, graft reaction efficiency and homopolymer formation are determined by these factors. The structure of the resultant copolymers was confirmed instrumentally by Fourier transforms infrared spectroscopy; while both the surface morphology, crystalline structure and thermal properties were characterized by scanning electron microscopy, X-ray diffraction and thermal gravimetric analysis. Furthermore, the resultant copolymers were evaluated as environmental remediation materials via cadmium ions and cationic dyes removal from their solutions with different extent; in addition to higher swelling and chemical resistance in water as polar solvent and hydrochloric acid as acidic solution. The anticipated mechanisms involved in the synthesis are reported.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Theoretical Studies in Heterogenous Catalysis: Towards a Rational Design of Novel Catalysts for Hydrodesulfurization and Hydrogen Production

Traditionally, knowledge in heterogeneous catalysis has come through empirical research. Nowadays, there is a clear interest to change this since millions of dollars in products are generated every year in the chemical and petrochemical industries through catalytic processes. To obtain a fundamental knowledge of the factors that determine the activity of heterogeneous catalysts is a challenge for modern science since many of these systems are very complex in nature. In principle, when a molecule adsorbs on the surface of a heterogeneous catalyst, it can interact with a large number of bonding sites. It is known that the chemical properties of these bonding sites depend strongly on the chemical environment around them. Thus, there can be big variations in chemical reactivity when going from one region to another in the surface of a heterogeneous catalyst. A main objective is to understand how the structural and electronic properties of a surface affect the energetics for adsorption processes and the paths for dissociation and chemical reactions. In recent years, advances in instrumentation and experimental procedures have allowed a large series of detailed works on the surface chemistry of heterogeneous catalysts. In many cases, these experimental studies have shown interesting and unique phenomena. Theory is needed to unravel the basic interactions behind these phenomena and to provide a general framework for the interpretation of experimental results. Ideally, theoretical calculations based on density-functional theory have evolved to the point that one should be able to predict patterns in the activity of catalytic surfaces. As in the case of experimental techniques, no single theoretical approach is able to address the large diversity of phenomena occurring on a catalyst. Catalytic surfaces are usually modeled using either a finite cluster or a two-dimensionally periodic slab. Many articles have been published comparing the results of these two approaches. An important advantage of the cluster approach is that one can use the whole spectrum of quantum-chemical methods developed for small molecules with relatively minor modifications. On the other hand, the numerical effort involved in cluster calculations increases rather quickly with the size of the cluster. This problem does not exist when using slab models. Due to the explicit incorporation of the periodicity of the crystal lattice through the Bloch theorem, the actual dimension of a slab calculation depends only on the size of the unit cell. In practical terms, the slab approach is mainly useful for investigating the behavior of adsorbates at medium and high coverages. Very large unit cells are required at the limit of low to zero coverage, or when examining the properties and chemical behavior of isolated defect sites in a surface. In these cases, from a computational viewpoint, the cluster approach can be much more cost effective than the slab approach. Slab and cluster calculations can be performed at different levels of sophistication: semi-empirical methods, simple ab initio Hartree-Fock, ab initio post-Hartree-Fock (CI, MP2, etc), and density functional theory. Density-functional (DF) based calculations frequently give adsorption geometries with a high degree of accuracy and predict reliable trends for the energetics of adsorption reactions. This article provides a review of recent theoretical studies that deal with the behavior of novel catalysts used for hydrodesulfurization (HDS) reactions and the production of hydrogen (i.e. catalytic processes employed in the generation of clean fuels). These studies involve a strong coupling of theory and experiment. A significant fraction of the review is focused on the importance of size-effects and correlations between the electronic and chemical properties of catalytic materials. The article begins with a discussion of results for the desulfurization of thiophene on metal carbides and phosphides, systems which have the potential to become the next generation of industrial HDS catalysts. Then, systematic studies concerned with the hydrogen-evolution reaction (HER) on extended surfaces, organometallic complexes and enzymes are presented. Finally, the reasons for the high catalytic activity of Au-CeO{sub 2} and Cu-CeO{sub 2} in the production of hydrogen through the water-gas shift reaction (CO + H{sub 2}O {yields} H{sub 2} + CO{sub 2}) are analyzed. It is shown that theoretical methods are very valuable tools for helping in the rational design of heterogeneous catalysts.

02 PETROLEUM↗

Comparison of Observations and Predictions of Daytime Planetary-Boundary-Layer Heights and Surface Meteorological Variables in the Columbia River Gorge and Basin During the Second Wind Forecast Improvement Project

The second Wind Forecast Improvement Project (WFIP2) is an 18-month field campaign in the Pacific Northwest U.S.A., whose goal is to improve the accuracy of numerical-weather-prediction forecasts in complex terrain. The WFIP2 campaign involved the deployment of a large suite of in situ and remote sensing instrumentation, including eight 915-MHz wind-profiling radars, and surface meteorological stations. The evolution and annual variability of the daytime convective planetary-boundary-layer (PBL) height is investigated using the wind-profiling radars. Three models with different horizontal grid spacing are evaluated: the Rapid Refresh, the High-Resolution Rapid Refresh, and its nested version. The results are used to assess errors in the prediction of PBL height within the experimental and control versions of the models, with the experimental versions including changes and additions to the model parametrizations developed during the field campaign, and the control version using the parametrizations present in the National Oceanic and Atmospheric Administration/National Centers for Environmental Prediction operational version of the models at the start of the project. Results show that the high-resolution models outperform the low-resolution versions, the experimental versions perform better compared with the control versions, model PBL height estimations are more accurate on cloud-free days, and model estimates of the PBL height growth rate are more accurate than model estimates of the rate of decay. Finally, using surface sensors, we assess surface meteorological variables, finding improved surface irradiance and, to a lesser extent, improved 2-m temperature in the experimental version of the model.

54 ENVIRONMENTAL SCIENCES↗

Bulk ratio method for determining surface enhancement using Auger analysis

The surface analysis techniques of Auger electron spectroscopy (AES) and x-ray photoelectron spectroscopy (XPS) are often used to characterize the near surface composition of stainless steel. AES is most often used to determine the oxide thickness and the maximum chromium to iron ratio as this information is used to determine if the material is properly electropolished. XPS is primarily used to determine the near surface chemistry as well as the chromium to iron ratio. Instrument calibration is critical to reliable composition determination. For AES, the use of elemental sensitivity factors is found to be a significant source of error. Proposed is a new method for the determination of Cr/Fe ratios using AES. The resulting depth profiles show the proper stainless steel composition under the surface enhanced layer.

36 MATERIALS SCIENCE↗

In-situ fatigue monitoring procedure using nonlinear ultrasonic surface waves considering the nonlinear effects in the measurement system

Second harmonic generation using nonlinear ultrasonic waves have been shown to be an early indicator of possible fatigue damage in nuclear power plant components. This technique relies on measuring amplitudes, making it highly susceptible to variations in transducer coupling and instrumentation. This paper proposes an experimental procedure for in-situ surface wave nonlinear ultrasound measurements on specimen with permanently mounted transducers under high cycle fatigue loading without interrupting the experiment. It allows continuous monitoring and minimizes variation due to transducer coupling. Moreover, relations describing the effects of the measurement system nonlinearity including the effects of the material transfer function on the measured nonlinearity parameter are derived. An in-situ high cycle fatigue test was conducted using two 304 stainless steel specimens with two different excitation frequencies. A comprehensive analysis of the nonlinear sources, which result in variations in the measured nonlinearity parameters, was performed and the effects of the system nonlinearities are explained and identified. In both specimens, monotonic trend was observed in nonlinear parameter when the value of fundamental amplitude was not changing.

42 ENGINEERING↗

High-stability cryogenic scanning tunneling microscope based on a closed-cycle cryostat

We report on the design and operation of a cryogenic ultra-high vacuum (UHV) scanning tunneling microscope (STM) coupled to a closed-cycle cryostat (CCC). The STM is thermally linked to the CCC through helium exchange gas confined inside a volume enclosed by highly flexible rubber bellows. The STM is thus mechanically decoupled from the CCC, which results in a significant reduction of the mechanical noise transferred from the CCC to the STM. Noise analysis of the tunneling current shows current fluctuations up to 4% of the total current, which translates into tip-sample distance variations of up to 1.5 picometers. This noise level is sufficiently low for atomic-resolution imaging of a wide variety of surfaces. To demonstrate this, atomic-resolution images of Au(111) and NaCl(100)/Au(111) surfaces, as well as of carbon nanotubes deposited on Au(111), were obtained. Thermal drift analysis showed that under optimized conditions, the lateral stability of the STM scanner can be as low as 0.18 Å/h. Scanning Tunneling Spectroscopy measurements based on the lock-in technique were also carried out, and showed no detectable presence of noise from the closed-cycle cryostat. Using this cooling approach, temperatures as low as 16 K at the STM scanner have been achieved, with the complete cool-down of the system typically taking up to 12 h. These results demonstrate that the constructed CCC-coupled STM is a highly stable instrument capable of highly detailed spectroscopic investigations of materials and surfaces at the atomic scale.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of a new coaxial ion–molecule reaction region for low-pressure chemical ionization mass spectrometry with reduced instrument wall interactions

Abstract. Chemical ionization mass spectrometry (CIMS) techniques have become prominent methods for sampling trace gases of relatively low volatility. Such gases are often referred to as being “sticky”, i.e., having measurement artifacts due to interactions between analyte molecules and instrument walls, given their tendency to interact with wall surfaces via absorption or adsorption processes. These surface interactions can impact the precision, accuracy, and detection limits of the measurements. We introduce a low-pressure ion–molecule reaction (IMR) region primarily built for performing iodide-adduct ionization, though other adduct ionization schemes could be employed. The design goals were to improve upon previous low-pressure IMR versions by reducing impacts of wall interactions at low pressure while maintaining sufficient ion–molecule reaction times. Chamber measurements demonstrate that the IMR delay times (i.e., magnitude of wall interactions) for a range of organic molecules spanning 5 orders of magnitude in volatility are 3 to 10 times lower in the new IMR compared to previous versions. Despite these improvements, wall interactions are still present and need to be understood. To that end, we also introduce a conceptual framework for considering instrument wall interactions and a measurement protocol to accurately capture the time dependence of analyte concentrations. This protocol uses short-duration, high-frequency measurements of the total background (i.e., fast zeros) during ambient measurements as well as during calibration factor determinations. This framework and associated terminology applies to any instrument and ionization technique that samples compounds susceptible to wall interactions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a high precision dosimetry system for the measurement of surface dose rate distribution for eye applicators

Purpose: The therapeutic outcome of the therapy with ophthalmic applicators is highly dependent on the application of a sufficient dose to the tumor, whereas the dose applied to the surrounding tissue needs to be minimized. The goal for the newly developed apparatus described in this work is the determination of the individual applicator surface dose rate distribution with a high spatial resolution and a high precision in dose rate with respect to time and budget constraints especially important for clinical procedures. Inhomogeneities of the dose rate distribution can be detected and taken into consideration for the treatment planning. Methods: In order to achieve this, a dose rate profile as well as a surface profile of the applicator are measured and correlated with each other. An instrumental setup has been developed consisting of a plastic scintillator detector system and a newly designed apparatus for guiding the detector across the applicator surface at a constant small distance. It performs an angular movement of detector and applicator with high precision. Results: The measurements of surface dose rate distributions discussed in this work demonstrate the successful operation of the measuring setup. Measuring the surface dose rate distribution with a small distance between applicator and detector and with a high density of measuring points results in a complete and gapless coverage of the applicator surface, being capable of distinguishing small sized spots with high activities. The dosimetrical accuracy of the measurements and its analysis is sufficient (uncertainty in the dose rate in terms of absorbed dose to water is <7%), especially when taking the surgical techniques in positioning of the applicator on the eyeball into account. Conclusions: The method developed so far allows a fully automated quality assurance of eye applicators even under clinical conditions. These measurements provide the basis for future calculation of a full 3D dose rate distribution, which then can be used as input for a refined clinical treatment planning system. The improved dose rate measurements will facilitate a clinical study, which could correlate the therapeutic outcome of a brachytherapy treatment with an applicator and its individual dose rate distribution.

61 RADIATION PROTECTION AND DOSIMETRY↗

Airborne Infrasound Makes a Splash

Natural and anthropogenic events may create low frequency sound waves, or infrasound, that can travel for vast distances in planetary atmospheres. They permit the remote monitoring of geophysical activity over local to global scales. Most studies have utilized ground-based recorders, but it is possible to deploy acoustic sensors to altitudes of over 50 km. Such elevated platforms can capture sounds that their surface analogs cannot access. High altitude balloons and low altitude aerostats are filling this observation gap, but key environments remain out of reach of both of these. Furthermore, recent work by den Ouden, Smets et al. (2021) addressed this with a new instrumentation platform—a large seabird flying just above the ocean's surface. Their work demonstrates that, infrasound sensing using heavier-than-air platforms in windy environments is possible, which has implications both terrestrially (e.g., extending sensor networks over the oceans) and extraterrestrially (proposed or planned missions to Venus and Titan).

47 OTHER INSTRUMENTATION↗

Secondary Aerosol: Precursors and Formation Mechanisms. Technical Report on Grant

This project focused on studying trace gases that participate in chemical reactions that form atmospheric aerosols. Ammonium sulfate is a major constituent of these tiny particles, and one important pathway to sulfate formation is oxidation of dissolved sulfur dioxide by hydrogen peroxide in cloud, fog and rainwater. Sulfate aerosols influence the number and size of cloud droplets, and since these factors determine cloud radiative properties, sulfate aerosols also influence climate. Peroxide measurements, in conjunction with those of other gaseous species, can used to distinguish the contribution of in-cloud reaction to new sulfate aerosol formation from gas-phase nucleation reactions. This will lead to more reliable global climate models. We constructed and tested a new 4-channel fluorescence detector for airborne detection of peroxides. We integrated the instrument on the G-1 in January, 2006 and took a test flight in anticipation of the MAX-Mex field program, where we planned to fly under pressurized conditions for the first time. We participated in the 2006 Megacity Initiative: Local and Global Research Observations (MILAGRO) - Megacity Aerosol EXperiment Mexico City (MAX-Mex) field measurement campaign. Peroxide instrumentation was deployed on the DOE G-1 research aircraft based in Veracruz, and at the surface site at Tecamac University.

47 OTHER INSTRUMENTATION↗

DUSEL Research and Development on Sub-Kelvin Germanium Detectors for Ton Scale Dark Matter Search (Final Technical Report)

We have supported one graduate student and a small percentage of fabrication staff on $\$$135k per year for three years plus one no cost extension year on this DUSEL R&D grant. There were three themes within our research program: (1) how to improve the radial sensitivity for single sided phonon readout with four equal area sensors of which three form a central circle and fourth a surrounding ring; (2) how to instrument double sided phonon readouts which will give us better surface event rejection and increased fiducial volume for future CDMS style detectors; and (3) can we manufacture much larger Ge detectors using six inch diameter material which is not suitable for standard gamma ray spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Atomic Force Microscope Controlled Topographical Imaging and Proximal Probe Thermal Desorption/Ionization Mass Spectrometry Imaging

This paper reports on the development of a hybrid atmospheric pressure atomic force microscopy/mass spectrometry imaging system utilizing nano-thermal analysis probes for thermal desorption surface sampling with subsequent atmospheric pressure chemical ionization and mass analysis. The basic instrumental setup and the general operation of the system were discussed and optimized performance metrics were presented. The ability to correlate topographic images of a surface with atomic force microscopy and a mass spectral chemical image of the same surface, utilizing the same probe without moving the sample from the system, was demonstrated. Co-registered mass spectral chemical images and atomic force microscopy topographical images were obtained from inked patterns on paper as well as from a living bacterial colony on an agar gel. Spatial resolution of the topography images based on pixel size (0.2 m x 0.8 m) was better than the resolution of the mass spectral images (2.5 m x 2.0 m), which were limited by current mass spectral data acquisition rate and system detection levels.

Ovchinnikova, Olga S↗

Direct Observation of Plasma-Stimulated Activation of Surface Species Using Multimodal In Situ/Operando Spectroscopy Combining Polarization-Modulation Infrared Reflection-Absorption Spectroscopy, Optical Emission Spectroscopy, and Mass Spectrometry

Nonthermal plasmas (NTPs) produce reactive chemical environments, including electrons, ions, radicals, and vibrationally excited molecules, that can drive chemistry at temperatures at which such species are thermally inaccessible. There has been growing interest in the integration of conventional catalysis with reactive NTPs to promote novel chemical transformations. Unveiling the full potential of plasma-catalytic processes requires a comprehensive understanding of plasma-catalytic synergies, including characterization of plasma-catalytic surface interactions. In this work, we report on a newly designed multimodal spectroscopic instrument combining polarization-modulation infrared reflection-absorption spectroscopy (PM-IRAS), mass spectrometry, and optical emission spectroscopy (OES) for the investigation of plasma–surface interactions such as those found in plasma catalysis. In particular, this tool has been utilized to correlate plasma-phase chemistry with both surface chemistry and gas-phase products in situ (1) during the deposition of carbonaceous surface species via NTP-promoted nonoxidative coupling of methane and (2) during subsequent activation of surface deposits with an atmospheric pressure and temperature argon plasma jet on both nickel (Ni) and silicon dioxide (SiO 2 ) surfaces. For the first time, the activation of carbonaceous surface species by a NTP on Ni and SiO 2 surfaces to form hydrogen gas and C 2 hydrocarbons was directly observed, where both PM-IRAS and OES measurements suggest that they may form through different pathways. Furthermore, this unique tool for studying plasma–surface interactions could enable more rational design of plasma-stimulated catalytic processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Green’s function for a sharpened and metal-coated dielectric probe

In apertureless scanning-probe optical microscopy and in the case of more traditional scanned optical probes coated with a metal that is thin near the probe tip (in lieu of an aperture), samples are probed via interaction between the probe and surface. In the nanometer-scale region between the tip and the sample, the field can be approximated by quasi-electrostatic analytics. Hence, the coated probe can be modeled as in the present case as a hyperboloid of revolution without the need for hyperboloidal wave functions in the near zone. The solutions to Laplace’s equation and in general Green’s function with the application of the boundary conditions, therefore, yield an appropriate approximation and allow a completely analytical solution for the resonance effects upon the probe tip to be obtained. In conclusion, the large field enhancements due to the sharpness of the tip and to surface plasmon fields may thus be analytically examined.

47 OTHER INSTRUMENTATION↗

Active–Source Seismic Tomography at the Brady Geothermal Field, Nevada, with Dense Nodal and Fiber–Optic Seismic Arrays

We deployed a dense seismic array to image the shallow structure in the injection area of the Brady Hot Springs geothermal power plant in western Nevada. The array was composed of 238 three-component, 5 Hz nodal instruments, 8700 m of distributed acoustic sensing (DAS) fiber-optic cable (FOC) installed horizontally in surface trenches, and 400 m of FOC installed vertically in a borehole. The geophone array had about 60 m instrument spacing in the target zone, whereas DAS channel separations were about 1 m with an averaging (gauge) length of 10 m. The acquisition systems provided 15 days of continuous records, including active-source and ambient noise signals. A large vibroseis truck was operated at 196 locations, exciting a swept-frequency signal from 5 to 80 Hz over 20 s using three vibration modes (vertical, longitudinal, and transverse), with three sweeps per mode at each site. Sweeps were repeated up to four times at each site during four different stages of power plant operation: normal operation, shutdown, high and oscillatory injection and production, and normal operation. After removal of the sweep signal from the raw data, the first P-wave arrivals were automatically picked using a combination of methods. Here, the travel times were then used to invert for the 3D P-wave velocity structure. Models with 100 m horizontal and 20–50 m vertical node spacing were obtained, covering an area 2000 m by 1300 m, with acceptable resolution extending to about 250 m below surface. The travel-time data were fit to a root mean square (rms) misfit of 31 ms, close to our estimated picking uncertainty. Lateral boundaries between high and low velocity zones agree relatively well with the location of local faults from previous studies, and low near-surface velocities are associated with faults and fumarole locations. A sharp increase in velocity from < 1500 to > 2000 m/s at approximately 50 m below the ground surface in many parts of the study area may indicate a shallower water table than expected for the region.

15 GEOTHERMAL ENERGY↗