Search NASA⌕ Search

SEARCH · Search NASA

Results for “voltage regulators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Preliminary Analysis of Nuclear-Powered Data Center Scenarios

This report provides a comprehensive analysis of the potential for nuclear energy to meet the growing energy demands of data centers (DCs). It evaluates the technical, economic, and socio-environmental implications of coupling Nuclear Power Plants (NPPs) with DCs, providing initial responses to several key research questions: What is the potential increased energy demand from DCs in the U.S., in the short, medium and long term? The U.S. is experiencing a rapid increase in energy demand from DCs, with projections indicating a total increase of 24-74 GWy(e) by 2028. Meeting this demand with nuclear energy would require 27–85 GWe of installed capacity. While this surge is expected to slow in the long term, the DC industry needs reliable, scalable, and clean energy sources. How much nuclear capacity can be deployed to meet DC demand and in which timeframe? Several pathways for increasing nuclear capacity were identified, including uprates, restarts of recently retired reactors, power purchase agreements with existing fleet, and new construction. Approximately 20‒28 GWe of nuclear capacity could be dedicated to DCs by the early 2030s. How much High Assay Low Enriched Uranium (HALEU) would be needed to support some nuclear deployment scenarios for DCs? Meeting the deployment targets announced by Google and Amazon for the Kairos Power Fluoride-Salt-Cooled High-Temperature Reactor or KP-FHR (~500 MWe by 2035) and the Xe-100 (~1 GWe by 2040), respectively, requires ramping up 19.75% enriched HALEU production to ~6 t/yr by 2040. What types of nuclear energy/DC coupling options exist, and what are the different benefits/challenges? Five coupling options were analyzed, ranging from grid-connected configurations to colocated, behind-the-meter setups. Key design considerations include the proximity to high- and/or medium-voltage transmission lines, the desired internal fault tolerance, and the sources of alternative/backup power during outages. Each coupling option offers unique benefits and challenges in terms of reliability, system costs, regulation, timeline, etc. A list of NPP/DC deployment scenarios was developed, considering existing or newly built NPP or DC projects. Colocated DCs with new small modular reactors or large reactors on greenfield and brownfield sites are the focus of this report. What types of reactors, especially what size, may be incentivized by DCs? Reactor sizing optimization revealed that the ideal reactor size and number of units depend on DC demand, coupling configurations defined in this report, and other economic factors. Larger reactors are preferred for high-demand DCs and grid-connected systems, while larger number of smaller reactors are better suited for DC configurations without grid backup. Which sites may be compatible with co-located nuclear-powered DCs? Siting those projects is a complicated evaluation factoring local water resources, grid connection availability and reliability, IT infrastructure, local work force, proximity to population zones, etc. For this effort greenfield and brownfield sites such as retired coal-fired plants were used to evaluate this question. This evaluation is not meant to recommend any particular site but it highlights key siting criteria and demonstrates large-scale site availability. What are the socio-economic impacts of co-located nuclear-powered DCs? Those projects generate substantial economic benefits to the local economy, particularly in urban settings. Hyperscale DCs colocated with nuclear power plants (sized around 1 GW of power) can create nearly 1,700 jobs for annual operations and more than 7,300 jobs among the supply chain and local businesses as a result of increased household spending. Rural projects also provide significant benefits, but at lower magnitudes compared to urban deployments.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Study of the Protection Improvements for a Weak Grid Area With High Inverter-Based Resources (IBRs)

This project designs enhanced protection scheme for the real-world weak grid area with a high penetration of IBRs. As the existing protection schemes are originally designed for traditional synchronous machines, we first evaluate if the protection scheme will continue to operate reliably in systems with high levels of IBRs. Hardware relays are tested using a controller-hardware-in-the-loop setup. PSCAD electromagnetic transient simulation with IBR original equipment manufacturer black-box models is used to perform fault studies and generate COMTRADE data, which are replayed by a real-time digital simulator (RTDS) to feed input to the hardware relays. Three scenarios are analyzed: normal operation, an N-1 contingency, and an IBR-only scenario. The evaluation results reveal the following: 1) the protection scheme remains reliable under normal conditions and N-1 contingencies and 2) in IBR-only scenarios, differential protection (87L) continues to operate reliably, whereas local protection elements, such as distance and directional elements, fail because of the lack of regulated negative sequence current contributed by IBRs. Enhanced protection is designed to address the challenge of lack of negative sequence current from IBRs, including increased restraining factors a2 and k2 to block 32Q or using V instead QV ORDER for ground faults, enhanced mho distance element with voltage and phase angle supervision for L-L faults. The efficacy of enhanced protection logic is validated and proven to work reliably. Additionally, IEEE Std. 2800-2022 negative sequence current compliant GFL and GFM IBRs from another vendor are tested and proven to work reliably without need for enhanced logic. Therefore, this work provides valuable decision-making for utilities facing protection system challenges due to IBRs, either designing enhanced protection scheme or requesting their IBRs being IEEE Std. 2800-2022 compliant to produce regulated negative sequence current for protection relay to make correct decision.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Charge Regulation Stabilizes the Formation of Ionic Liquid‐Based Amphiphilic Oligomer Droplet Interface Bilayers

Amphiphilic charged oligomers (oligodimethylsiloxane – methylimidazolium cation, ODMS-MIM (+) ), assemble into bilayers using the droplet interface bilayer (DIB) platform, possess similar size and functionality as phospholipid bilayers, but exhibit increased stability. The oligomer ionic headgroups (MIM (+) ) are covalently bound to monodisperse, short-chain (n = 13) hydrophobic tails (ODMS). These self-assemble as monolayer brushes at the oil–aqueous interface of water droplets that are influenced by both the charged cationic headgroups, and the nature of the covalently attached tails in the organic phase. Charge regulation (CR) stabilizes the formation of ordered, molecularly close-packed brush phases, which results in highly insulating, stable DIB membranes, with contributions from specific ion-pairing effects, Debye screening, and voltage-dependent electrocompressive stresses. In the oil phase, interactions between hexadecane, a good solvent for ODMS, and the hydrophobic tails result in extended waiting times for bilayer formation compared to phospholipid DIBs, for which hexadecane is a poor solvent. Close agreement between experimental values and predictions for two key parameters, the critical membrane thickness, h c , and maximal grafted headgroup density, Γ 0 , validate an electrostatic CR model consisting of adsorption and partial neutralization of counterions at a charged interface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhancing Synchronous Condenser Operation of Hydrogenerators

Hydropower plants are sometimes dispatched below capacity or even shut down to meet water regulations. These can temporarily be repurposed to operate as synchronous condensers. To enable this capability, this paper proposes a design that allows hydrogenerators to safely operate as synchronous condensers, providing fast voltage and reactive power support under both normal and boost conditions. The proposed design integrates capability curves with hydrogenerators’ excitation systems through modifications using proposed MVA-field current curve, current controller, and limiter. The design is implemented locally at the machine for rapid response. Simulation results demonstrate the effectiveness of the proposed design and using hydrogenerators as synchronous condensers in power grids.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Constructing uniform oxygen defect engineering on primary particle level for high-stability lithium-rich cathode materials

Lithium-rich layered cathode materials are considered to be research focus of cathode candidates for next generation lithium-ion batteries due to their high specific capacity and low cost. However, lattice deoxidation associated with elemental migration and internal local shrinkage usually results in deteriorated cyclic performance and notorious voltage attenuation, severely limiting its application. In this paper, we have successfully injected uniform oxygen defects into surface region of Li 1.2 Ni 0.13 Co 0.13 Mn 0.54 O 2 primary particles under the high-pressure and weak carbonate environment. Various experimental investigations indicate that the injected robust oxygen defects can not only mitigate detrimental interfacial reactions but also suppress unfavorable lattice variation and particle breakage. More importantly, theoretical calculations unravel the critical roles of oxygen defects in regulating energy band structure for strengthened anionic reversibility. Owing to stabilization effects of unique oxygen defect engineering, the modified Li 1.2 Ni 0.13 Co 0.13 Mn 0.54 O 2 cathode has harvested dramatically enhanced electrochemical performance including a high initial coulombic efficiency of 96.6%, an outstanding capacity retention of 91.96% (1C, 200 cycles) and suppressed voltage decay of only 1.62 mV per cycle. Therefore, this facile and effective defect engineering strategy could establish new guidance for promoting practical application of Li-rich Mn-based cathode material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Modulating physicochemical interfaces enables li-rich oxides based ceramic solid-state li batteries under ambient conditions

Li-rich layered oxides exhibit promising potential applications in high-energy-density solid-state lithium metal batteries. Nevertheless, the strong oxidative oxygen species generate at high voltage, which poses great challenges to positive electrode-side interface stability. Herein, a robust in-situ polymerization gel polymer electrolyte with bifunctional additives is designed for interface modification. These additives, include lithium difluoro(oxalate) borate and LiPO 2 F 2 , regulate the Li + chemical environment in gel polymer electrolyte to enhance crosslink density without residual oligomer, which reduce gas generation and suppress contact loss, thus avoiding interfacial impedance divergence. Concurrently, the designed gel polymer electrolyte enables a wide electrochemical stability window (up to 4.7 V) and a high Li + transference number (0.82). Additionally, the additives induced F- and B-rich inorganic cathode-electrolyte interphase inhibits side reactions and oxygen/transition metal loss effectively, stabilizing the chemical interface. The as-constructed Li-rich layered oxides-based ceramic solid-state lithium metal batteries with gel polymer electrolyte interface modification exert a high discharge capacity of 276.5 mAh g -1 at 30 °C without external pressure, delivering a retention of 81.7% after 100 cycles at 25 mA g -1 during 2.0-4.7 V. This work provides a guideline for developing high-voltage solid-state lithium metal batteries via interfacial design.

Hu, Xinchao [Xiamen University (China)]↗

Maximum Power Reference Tracking Algorithm for Power Curtailment of Photovoltaic Systems

This paper presents an algorithm for power curtailment of photovoltaic (PV) systems under fast solar irradiance intermittency. Based on the Perturb and Observe (P&O) technique, the method contains an adaptive gain that is compensated in real-time to account for moments of lower power availability. In addition, an accumulator is added to the calculation of the step size to reduce the overshoot caused by large irradiance swings. A testbed of a three-phase single-stage, 500 kVA PV system is developed on the OPAL-RT eMEGAsim real-time simulator. Field irradiance data and a regulation signal from PJM (RTO) are used to compare the performance of the proposed method with other techniques found in the literature. Results indicate an operation with smaller overshoot, less dc-link voltage oscillations, and improved power reference tracking capability.

Paduani, Victor↗

Short Circuit Detection and Voltage Sense for High Voltage Ionization Tube Power Supplies

Fermilab's PIP-II upgrade requires new rack-mounted power supplies for Beam Loss Monitor (BLM) ionization tubes compatible with the microTCA 4.1 standard, supporting high-side current measurement for short circuit detection, voltage sense telemetry, and low-side current measurement for beam loss readout. This work presents the design and preliminary schematic of such a supply. A resistive current sensing approach was chosen over inductive, optical, and Hall-effect alternatives for its independence from cable length and component availability. A 500 mΩ inline shunt steps the 2 kV common mode voltage down to roughly 70 V, producing a ~27 μV pulse during a short, which is amplified 500x, compared against a 14-bit DAC threshold, and latched to drive a fault line. Voltage sense steps the 2 kV output down at a 1V/1000V ratio, buffers it with a low bias current amplifier, and digitizes it via a 24-bit ADC over SPI. Onboard power is regulated from 12 V down to isolated 5 V and 3.3 V rails, with capacitive isolation on FPGA communication lines. Lumped parameter models were developed for the ionization tube (0.327 nF, 20 to 200 GΩ dynamic resistance) and the RG-58 coaxial cable to support the design. Component selection is complete and a preliminary schematic has been drawn in Altium Designer, forming the foundation for future prototyping and validation.

Yu, Kellen [Cornell U.]↗

Isochronous Architecture-Based Voltage-Active Power Droop for Multi-Inverter Systems

This article proposes an isochronous architecture for parallel inverters with only voltage-active power droop (VP-D) control for improving active power sharing as well as plug-and-play of multi-inverter-based distributed energy resources (DERs). The isochronous framework obviates the need for an explicit regulation of the frequency while allowing for sharing of reactive power. The article shows that the detrimental effects of circulating currents between inverters can be addressed in the framework developed. The isochronous architecture is implemented by employing a GPS to disseminate clock timing signals that enable the microgrid to maintain the nominal system frequency. Small signal eigenvalue analysis of a Multi-inverter Microgrid system near the steady-state operating point is presented to evaluate the system stability. Moreover, unlike traditional droop-based methods, the isochronous strategy lends itself to analytical guarantees which are developed in the article. Furthermore, the effect of delays in receiving GPS clock signals by an inverter is experimentally characterized and an inverter isolation mechanism is proposed that disconnects inverters facing large GPS communication delays. Hardware experiments on an 1.2 kVA-prototype and controller-hardware-in-the-loop validation on the CIGRE distribution network are conducted to demonstrate the effectiveness of the proposed architecture towards active and reactive power sharing between inverters with load scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Investigation of Fe-Ni Battery/Module for Grid Service Duty Cycles

Iron–nickel (Fe-Ni) batteries are renowned for their durability and resilience against overcharging and operating temperatures. However, they encounter challenges in achieving widespread adoption for energy storage applications due to their low efficiency and the need for regular maintenance and electrolyte replacement, which adds to maintenance costs. This study evaluates and demonstrates the capabilities of Fe-Ni batteries for participating in grid energy storage applications. Stable performance was observed frequency regulation (FR) testing at 100% and 50% state of charge (SOC)s, while at 50% SOC, there was a 14% increase in efficiency compared to 100% SOC. Although 25% SOC achieved higher efficiency, limited cyclability was observed due to reaching the discharge cutoff voltage. Optimal SOC selection, battery monitoring, maintenance, and appropriate charging strategies of Fe-Ni batteries seem to be crucial for their FR applications. Fe-Ni batteries exhibit stable peak shaving (PS) results, indicating their suitability and reliability under various load conditions for PS testing. Extended cycling tests confirm their potential for long-term grid-scale energy storage, enhancing their appeal for PS and FR applications.

25 ENERGY STORAGE↗

Operando characterization and regulation of metal dissolution and redeposition dynamics near battery electrode surface

Mn dissolution has been a longstanding, ubiquitous issue that negatively impacts the performance of Mn-based battery materials. Mn dissolution involves complex chemical and structural transformations at the electrode-electrolyte interface. The continuously evolving electrodeelectrolyte interface has posed great challenges for characterizing the dynamic interfacial process and quantitatively establishing the correlation with battery performance. In this study, we visualize and quantify the temporally and spatially resolved Mn dissolution/redeposition (D/R) dynamics of electrochemically operating Mn-containing cathodes. The particle-level and electrode-level analyses reveal that the D/R dynamics is associated with distinct interfacial degradation mechanisms at different states of charge. Our results statistically differentiate the contributions of surface reconstruction and Jahn-Teller distortion to the Mn dissolution at different operating voltages. Introducing sulfonated polymers (Nafion) into composite electrodes can modulate the D/R dynamics through trapping the dissolved Mn species and rapidly establishing the local Mn D/R equilibrium. This work represents an inaugural effort to pinpoint the chemical and structural transformations responsible for Mn dissolution via an operando synchrotron study and develops an effective method to regulate Mn interfacial dynamics for improving battery performance.

25 ENERGY STORAGE↗

Assessing the Intrinsic Roles of Key Dopant Elements in High–Nickel Layered Oxide Cathodes in Lithium–Based Batteries

A rational compositional design is critical for utilizing LiNiO 2 -based cathodes with Ni contents > 90% as promising next-generation cathode materials. Unfortunately, the lack of a fundamental understanding of the intrinsic roles of key elements, such as cobalt, manganese, and aluminum, makes the rational compositional design of high-Ni cathodes with a limited range of dopants (<10%) particularly challenging. Here, with 5% single-element doped cathodes, viz., LiNi 0.95 Co 0.05 O 2 , LiNi 0.95 Mn 0.05 O 2 , and LiNi 0.95 Al 0.05 O 2 , along with undoped LiNiO 2 (LNO), the influences of the dopants are systematically examined through a control of cutoff charge energy density and a common practice of cutoff charge voltage. Comprehensive investigations into the electrochemical properties, combined with in-depth analyses of the structural and interfasial stabilities and electrolyte decomposition pathways through advanced characterizations, unveil the following: i) the intrinsic role of dopants regulates the cathode energy density or state-of-charge and, more critically, the occurrence of H2–H3 phase transition, which essentially dictates cyclability; ii) undoped LNO can be stabilized well with the avoidance of H2–H3 phase transition; and iii) Co provides more merits overall with an optimized electrochemical operating condition. Finally, this work provides guidance for the compositional design of high-energy-density high-Ni cathodes and sheds light on the challenges of removing Co.

25 ENERGY STORAGE↗

Enhanced charge carrier extraction and transport with interface modification for efficient tin-based perovskite solar cells

Interface modification improves charge carrier extraction in tin-based perovskite solar cells. Tin-based perovskites have become the most promising non-lead perovskites due to their ideal band gap and low toxicity. Although the open circuit voltage of tin-based perovskite solar cells (TPSCs) continues to approach the theoretical value, the short-circuit current is still far from the theoretical value. Here, we describe an interface modification method by regulating the property of hole transport layer, PEDOT:PSS, which improves the surface molecular morphology and the energy level alignment of PEDOT:PSS/perovskite interface. Advanced GIWAXS and IR s-SNOM characterization are conducted to achieve multi-dimensional characterization of nanoscale surface morphology and chemical distribution of PEDOT:PSS. With the multi-attribute optimization, charge carrier extraction and non-radiative recombination are also improved. The resultant TPSCs exhibit a higher power conversion efficiency of 13.32% in compared with the control device of 10.50%, accompanied with an increase in the short-circuit current from 18.10 to 20.50 mA cm −2 and FF from 68.23% to 76.43%. This work demonstrates a reliable strategy for improving charge carrier extraction and device performance for lead-free TPSCs.

Zhao, Zhenzhu↗

Bulk Oxygen Stabilization via Electrode–Electrolyte Interphase Tailored Surface Activities of Li–Rich Cathodes

The O3-type Li-rich layered oxides (LLOs) are approaching industrial applications as high-energy cathode materials for Li-ion batteries (LIBs), however, they suffer from rapid performance decay associated with oxygen activities. The interplay between surface and bulk transformations in LLOs, especially the electrochemical behaviors of oxygen anions, remains elusive. Here, by regulating the surface of an O3-type LLO (Li 1.13 Mn 0.517 Ni 0.256 Co 0.097 O 2 ) using an all-fluorinated electrolyte, an enhanced capacity retention from 57.4% to 85.3% and a suppressed voltage decay from 1.34 mV cycle –1 to 0.58 mV cycle –1 within 300 cycles are realized. The performance enhancement is attributed to the thin, uniform, robust, and compact F-rich cathode-electrolyte interphase (CEI), which suppresses various types of oxygen-related surface degradation and, more importantly, stabilizes the bulk oxygen reactions. Finally, through the combined experimental and theoretical studies, this work directly reveals the intriguing association between the surface and bulk oxygen activities and demonstrates that optimizing the interphase is an effective approach for improving the stability of high-energy battery cathodes involving oxygen redox reactions.

25 ENERGY STORAGE↗

Aureochromes maintain polyunsaturated fatty acid content in Nannochloropsis oceanica

Abstract Nannochloropsis oceanica, like other stramenopile microalgae, is rich in long-chain polyunsaturated fatty acids (LC-PUFAs) such as eicosapentaenoic acid (EPA). We observed that fatty acid desaturases (FADs) involved in LC-PUFA biosynthesis were among the strongest blue light-induced genes in N. oceanica CCMP1779. Blue light was also necessary for maintaining LC-PUFA levels in CCMP1779 cells, and growth under red light led to a reduction in EPA content. Aureochromes are stramenopile-specific proteins that contain a light–oxygen–voltage (LOV)-sensing domain that associates with a flavin mononucleotide and is able to sense blue light. These proteins also contain a basic leucine zipper DNA-binding motif and can act as blue light-regulated transcription factors by associating with an E-box like motif, which we found enriched in the promoters of blue light-induced genes. We demonstrated that, in vitro, two CCMP1779 aureochromes were able to absorb blue light. Moreover, the loss or reduction of the expression of any of the three aureochrome genes led to a decrease in the blue light-specific induction of several FADs in CCMP1779. EPA content was also significantly reduced in NoAUREO2 and NoAUREO4 mutants. Taken together, our results indicate that aureochromes mediate blue light-dependent regulation of LC-PUFA content in N. oceanica CCMP1779 cells.

Plant Sciences↗

Thermal processing to modulate surface chemistry and bulk charge distribution in nickel-rich layered lithium positive electrodes

The broader application of nickel-rich layered oxides as positive electrode materials for lithium-ion batteries has been hindered by their high manufacturing cost and inferior cycling stability. Thermal processing, which is integral to electrode materials manufacturing and fundamental in materials science, has not been fully utilized to design advanced positive electrode materials. Herein, we demonstrate the capability of using quenching heat treatment to regulate Li distribution and modulate electronic structure near particle surface. The resulting materials exhibit less parasitic reactions with the electrolyte and an improved charge distribution homogeneity in secondary particles, leading to more stable cycling performance at high voltages (4.5 V vs Li/Li + ). Our synchrotron X-ray analyses reveal the underlying interplay between surface structure and bulk charge distribution in positive electrode materials particles. While strategies used to stabilize positive electrode materials through compositional control, surface modification, and electrolyte engineering have become mature, thermal processing can be advantageous to further improve positive electrode materials manufacturing.

36 MATERIALS SCIENCE↗

Controllers for Distributed Grid Support for Power Systems using Hybrid DER plants with Electrolyzers [SWR-20-06]

This software presents the design and control for a hybrid DER site with integrated dispatchable electrolyzers. It is a comprehensive solution for regulating the dispatch of electrolyzer demand to support the grid using the respective control functions. Multiple control functions (ramp control, frequency support control, dispatch prioritization) are developed to integrate the proposed site for multiple services around load, voltage and frequency control. This allows the site owners to participate in both distribution and bulk system energy markets for grid ancillary services.

Jain, Rishabh↗

Dielectric screening in perovskite photovoltaics

Abstract The performance of perovskite photovoltaics is fundamentally impeded by the presence of undesirable defects that contribute to non-radiative losses within the devices. Although mitigating these losses has been extensively reported by numerous passivation strategies, a detailed understanding of loss origins within the devices remains elusive. Here, we demonstrate that the defect capturing probability estimated by the capture cross-section is decreased by varying the dielectric response, producing the dielectric screening effect in the perovskite. The resulting perovskites also show reduced surface recombination and a weaker electron-phonon coupling. All of these boost the power conversion efficiency to 22.3% for an inverted perovskite photovoltaic device with a high open-circuit voltage of 1.25 V and a low voltage deficit of 0.37 V (a bandgap ~1.62 eV). Our results provide not only an in-depth understanding of the carrier capture processes in perovskites, but also a promising pathway for realizing highly efficient devices via dielectric regulation.

14 SOLAR ENERGY↗