Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electrode Engineering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Propellant-Flow-Actuated Rocket Engine Igniter

A rocket engine igniter has been created that uses a pneumatically driven hammer that, by specialized geometry, is induced into an oscillatory state that can be used to either repeatedly impact a piezoelectric crystal with sufficient force to generate a spark capable of initiating combustion, or can be used with any other system capable of generating a spark from direct oscillatory motion. This innovation uses the energy of flowing gaseous propellant, which by means of pressure differentials and kinetic motion, causes a hammer object to oscillate. The concept works by mass flows being induced through orifices on both sides of a cylindrical tube with one or more vent paths. As the mass flow enters the chamber, the pressure differential is caused because the hammer object is supplied with flow on one side and the other side is opened with access to the vent path. The object then crosses the vent opening and begins to slow because the pressure differential across the ball reverses due to the geometry in the tube. Eventually, the object stops because of the increasing pressure differential on the object until all of the kinetic energy has been transferred to the gas via compression. This is the point where the object reverses direction because of the pressure differential. This behavior excites a piezoelectric crystal via direct impact from the hammer object. The hammer strikes a piezoelectric crystal, then reverses direction, and the resultant high voltage created from the crystal is transferred via an electrode to a spark gap in the ignition zone, thereby providing a spark to ignite the engine. Magnets, or other retention methods, might be employed to favorably position the hammer object prior to start, but are not necessary to maintain the oscillatory behavior. Various manifestations of the igniter have been developed and tested to improve device efficiency, and some improved designs are capable of operation at gas flow rates of a fraction of a gram per second (0.001 lb/s) and pressure drops on the order of 30 to 50 kilopascal (a few psi). An analytical model has been created and tested in conjunction with a precisely calibrated reference model. The analytical model accurately captures the overall behavior of this innovation. The model is a simple "volume-orifice" concept, with each chamber considered a single temperature and pressure "node" connected to adjacent nodes, or to vent paths through flow control orifices. Mass and energy balances are applied to each node, with gas flow predicted using simple compressible flow equations.

Wollen, Mark↗

Engineering lithium-ion battery cathodes for high-voltage applications using electromagnetic excitation

Microwave radiation (MWR), a type of electromagnetic excitation source, reduces the synthesis temperature and processing time for chemical reactions compared to traditional synthesis methods. Recently, we demonstrated that MWR can engineer ceramics with different crystal phases compared to traditional methods [ Journal of Materials Chemistry A 5 , 35 (2017)]. Here, we further apply the MWR-assisted technique to improve the electrochemical performance of LiCoO 2 cathodes by engineering TiO 2 and ZrO 2 ceramic coatings. Electrochemical tests suggest that the TiO 2 coating improves the rate capability of the LiCoO 2 electrode. Both TiO 2 and ZrO 2 coatings improve the high-voltage (4.5 V) cycling stability of LiCoO 2 . The capacity remaining is improved from 52.8 to 84.4% and 81.9% by the TiO 2 coating and the ZrO 2 coating, respectively, after 40 cycles. We compare these results with existing studies that apply traditional methods to engineer TiO 2 /ZrO 2 on LiCoO 2 , and find that the MWR-assisted method shows better performance improvement. X-ray photoelectron spectroscopy measurements suggest that the improved cycling stability arises from the formation of metal fluorides that protect the electrode from side reactions with electrolytes. This mechanism is further supported by the reduced Co dissolution from TiO 2 /ZrO 2 -coated LiCoO 2 electrode after cycling. This study provides a new toolbox facilitating the integration of many delicate, low melting point materials like polymers into battery electrodes.

25 ENERGY STORAGE↗

Progress in Development of Electrochemical Methods in Corrosion Science and Engineering

The role and impact of four electrochemical techniques in the study of various corrosion applications are discussed, these are: scanning vibrating electrode technique (SVET), coupled multi-electrode array (CMEA) technique, scanning electrochemical microscope (SECM) and atomic emission spectroelectrochemistry (AESEC). A common theme is an ability to monitor corrosion phenomena in situ on a local electrochemical scale with high resolution of electrochemical and, in some cases, chemical reaction rates. In all cases, the techniques presented here are discussed in the context of specific corrosion problems carried out in full immersion conditions. Examples taken from the current literature, and new data, are presented to demonstrate the use and advantages of these techniques, or a combination of these techniques, as powerful tools for industrially important applications. Here, this includes: assessment of the galvanic interactions and throwing-power of metal-rich primer coatings for active corrosion protection, corrosion/corrosion resistance mechanisms of new metal alloys, the effect of pretreatments on coating integrity, current distributions within a crevice and pitting corrosion.

AESEC↗

Advanced PGM-free Cathode Engineering for High Power Density and Durability

Polymer electrolyte fuel cells (PEFCs) are among the most promising technologies for future electric vehicles by using clean H2 with much-improved energy conversion efficiency, longer range, and rapid refueling. However, due to a large amount of platinum group metal (PGM) catalyst used in their electrodes, their prohibitively high cost hinders broad commercialization of PEFCs for transportation. Therefore, there is a critical need to develop low-cost, high-performance PGM-free cathode catalysts that have the potential to dramatically transform the economics of PEFC commercialization by reducing catalyst costs by one to two orders of magnitude. However, before PGM-free cathodes become viable, several technical challenges associated with PGM-free cathodes must be addressed, including insufficient activity and stability of the catalysts, as well as severe water flooding and large transport losses in the electrodes. Overcoming those barriers and ultimately meeting the challenging automotive PEFC performance targets was the focus of this comprehensive research and development effort on new PGM-free cathodes. To this end, we assembled a team including leading researchers from universities and industry with different but complementary expertise and capabilities. The project combined three novel and promising approaches: Advanced metal-organic framework (MOF)-derived M-N-C catalysts with a high activity and impressive durability, Novel PGM-free specific cathode architectures and fabrication strategies capable of addressing the substantial flooding and transport resistances in thicker cathodes by introducing engineered hydrophobicity through additives and support layers, and Advanced electrode ionomers with high proton conductivity for low ohmic losses across the electrode and more uniform catalyst utilization. The implementation of these new materials and electrode designs was supported by a suite of advanced experimental and simulation tools that allows us to identify performance and durability bottlenecks, devise solutions, and establish rational material design and synthesis targets. These methods include advanced electrochemical characterization, high-resolution imaging, and multi-scale modeling. In addition, the project team leveraged a broad cross-section of the ElectroCat consortium’s national laboratory facilities and expertise in advancing these materials and design strategies. Finally, the industry partners on the project facilitated the evaluation of scaled-up synthesis and manufacturing in the United States. Over its four-year period, the project made significant year-over-year advances in PGM-free cathode performance and viability. A combination of high activity and highly durable catalysts were developed through novel catalyst synthesis strategies, which met several performance and durability targets. More specifically, a catalyst prepared from MOFs and Fe2O3 nanoparticles with ammonium chloride and chemical vapor deposition treatments yielded a significant advancement in PGM-free cathode durability. Several novel strategies for fabricating cathodes were demonstrated, including those designed to reduce flooding and thickness of the cells for significantly increased volumetric power density. An optimized cathode with high conductivity ionomer and tuned ink processing for hydrophobicity yielded high fuel cell performance with new levels power density and maximum current. The scientific studies and modeling assessment also provided an outlook for future efforts, including a focus on catalysts with an increased density of the highly stable active sites developed in this project.

08 HYDROGEN↗

Avoiding Fracture in a Conversion Battery Material through Reaction with Larger Ions

Conversion and alloying electrode materials offer high specific capacity for emerging sodium- and potassium-ion batteries, but the larger volume changes compared to reaction with lithium are thought to limit cyclability. The reaction mechanisms of many materials with Na + and K + are unknown, however, and this knowledge is key for engineering mechanically resilient materials. Here, in situ transmission electron microscopy is used to uncover the nanoscale transformations during the reaction of FeS 2 electrode materials with Li + , Na + , and K + . Surprisingly, despite larger volume changes during the conversion reaction with Na + and K + , the FeS 2 crystals only fracture during lithiation. Modeling of reaction-induced deformation shows that the shape of the two-phase reaction front influences stress evolution, and unique behavior during lithiation causes stress concentrations and fracture. The larger volume changes in Na- and K-ion battery materials may therefore be managed through understanding and control of reaction mechanisms, ultimately leading to better alkali-ion batteries.

25 ENERGY STORAGE↗

Resonant Mode Engineering of Photonic Crystal Sensors Clad with Ultralow Refractive Index Porous Silicon Dioxide

Porous SiO 2 (PSiO 2 ) with ultralow refractive index ($n$ = 1.09) is incorporated as the cladding of a photonic crystal (PC) refractive index sensor with enhanced sensitivity through the establishment of resonant modes that principally reside in the liquid medium covering the PC surface. PSiO 2 , obtained by thermal oxidation of porous Si that has been transferred to a transparent substrate, is transparent at visible and near infrared wavelengths with a refractive index determined by its porosity. The PSiO 2 periodic grating structure ($Λ$ = 590 nm) is patterned by nanoimprint lithography and reactive ion etching, then conformally coated by sputtering high refractive index TiO 2 to seal the pores from liquid infiltration. With the refractive index of PSiO 2 much lower than that of water, the resonant mode “flips” its spatial distribution from within the solid dielectric regions of the photonic crystal to reside mainly in the water media covering the PC, resulting in 4× greater resonant wavelength shift for a fixed refractive index change. This study demonstrates design, fabrication, and testing of the sensor as a refractometer, supported by electromagnetic simulations of the resonant mode spatial distribution, in which porous PC sensors are compared to nonporous PC sensors.

14 SOLAR ENERGY↗

Comparative Study on the Photoelectrochemical Hydrogen Production from the Layout Optimization in a Unit Cell

Solar-driven water splitting is achieved by connecting photovoltaics with electrolysis. Recently, integrated approaches of the two configurations for photoelectrochemical reactions have shown great potential in a combined unit, but strategies to address further material and cell development face significant scientific challenges. Here, in this work, we present an experimental demonstration of photoelectrochemical (PEC) unit-cells with efficient separate dual compartments for oxygen evolution and hydrogen evolution reactions. The design and fabrication of cell architectures with various degrees of integration are investigated efficient and sustainable PEC processes. The effect of the nanostructured silicon (Si) photoelectrodes, including the adoption of layer architectures, surface protection layer deposition, and membrane electrode assembly is further studied to optimize the design parameters of the PEC unit-cells. This developed PEC cell with the Si photocathode achieved a photocurrent density of -4.8 mA cm –2 at -2.0 V cell and -2.87 mA cm –2 at -1.6 V cell . It clearly provides a critical milestone for unbiased solar water splitting. Practical solar to hydrogen (STH) can be directly estimated in investigating PEC performance in this unit-cell as assembled with a solar cell. It is a significantly meaningful step forward in practical solar fuel production.

08 HYDROGEN↗

Carbon Electrode with Sputtered Au Coating for Efficient and Stable Perovskite Solar Cells

Halide perovskite solar cells (PSCs) represent a low-cost and high-efficiency solar technology. However, most of the highly efficient PSCs need a noble electrode, such as Au, through thermal evaporation. Here it is reported that a sputtered Au electrode on a PSC could damage the organic hole transport layer (HTL) and the perovskite layer. Here, we report a simple, yet effective sputtered gold nanoparticle decorated carbon electrode to fabricate efficient and stable planar PSCs. The sputtered Au layer on the doctor-bladed coated carbon electrode can be directly applied to the perovskite semicells by mechanical stacking. By optimizing the gold thickness, a power conversion efficiency (PCE) of 16.87% was obtained for the composite electrode-based PSC, while the reference device recorded a PCE of 12.38%. The composite electrode-based device demonstrated 96% performance retention after being stored under humid conditions (50-60%) without encapsulation for ~100 h. This demonstrates a promising pathway toward the commercialization of large-scale manufacturable sputtered electrodes for the PSC solar module.

14 SOLAR ENERGY↗

MEMS-tunable dielectric metasurface lens

Varifocal lenses, conventionally implemented by changing the axial distance between multiple optical elements, have a wide range of applications in imaging and optical beam scanning. The use of conventional bulky refractive elements makes these varifocal lenses large, slow, and limits their tunability. Metasurfaces, a new category of lithographically defined diffractive devices, enable thin and lightweight optical elements with precisely engineered phase profiles. Here we demonstrate tunable metasurface doublets, based on microelectromechanical systems (MEMS), with more than 60 diopters (about 4%) change in the optical power upon a 1-μm movement of one metasurface, and a scanning frequency that can potentially reach a few kHz. They can also be integrated with a third metasurface to make compact microscopes (~1 mm thick) with a large corrected field of view (~500 μm or 40 degrees) and fast axial scanning for 3D imaging. This paves the way towards MEMS-integrated metasurfaces as a platform for tunable and reconfigurable optics.

42 ENGINEERING↗

Suppressing sub-bandgap phonon-polariton heat transfer in near-field thermophotovoltaic devices for waste heat recovery

Here, we consider a near-field thermophotovoltaic device with metal as the emitter and semiconductor as the photovoltaic cell. We show that when the cell is a III-V semiconductor, such as GaSb, parasitic phonon-polariton heat transfer reduces efficiency in the near-field regime, especially when the temperature of the emitter is not high enough. We further propose ways to avoid the phonon-polariton heat transfer by replacing the III-V semiconductor with a non-polar semiconductor such as Ge. Our work provides practical guidance on the design of near-field thermophotovoltaic systems for efficient harvesting of low-quality waste heat.

14 SOLAR ENERGY↗

Rapid, all-optical crystal orientation imaging of two-dimensional transition metal dichalcogenide monolayers

Two-dimensional (2D) atomic materials such as graphene and transition metal dichalcogenides (TMDCs) have attracted significant research and industrial interest for their electronic, optical, mechanical, and thermal properties. While large-area crystal growth techniques such as chemical vapor deposition have been demonstrated, the presence of grain boundaries and orientation of grains arising in such growths substantially affect the physical properties of the materials. There is currently no scalable characterization method for determining these boundaries and orientations over a large sample area. We here present a second-harmonic generation based microscopy technique for rapidly mapping grain orientations and boundaries of 2D TMDCs. We experimentally demonstrate the capability to map large samples to an angular resolution of ±1° with minimal sample preparation and without involved analysis. A direct comparison of the all-optical grain orientation maps against results obtained by diffraction-filtered dark-field transmission electron microscopy plus selected-area electron diffraction on identical TMDC samples is provided. This rapid and accurate tool should enable large-area characterization of TMDC samples for expedited studies of grain boundary effects and the efficient characterization of industrial-scale production techniques.

36 MATERIALS SCIENCE↗

Investigation on the electron flux to the wall in the VENUS ion source

The long-term operation of high charge state electron cyclotron resonance ion sources fed with high microwave power has caused damage to the plasma chamber wall in several laboratories. Porosity, or a small hole, can be progressively created in the chamber wall which can destroy the plasma chamber over a few year time scale. A burnout of the VENUS plasma chamber is investigated in which the hole formation in relation to the local hot electron power density is studied. First, the results of a simple model assuming that hot electrons are fully magnetized and strictly following magnetic field lines are presented. The model qualitatively reproduces the experimental traces left by the plasma on the wall. However, it is too crude to reproduce the localized electron power density for creating a hole in the chamber wall. Second, the results of a Monte Carlo simulation, following a population of scattering hot electrons, indicate a localized high power deposited to the chamber wall consistent with the hole formation process. Finally, a hypervapotron cooling scheme is proposed to mitigate the hole formation in electron cyclotron resonance plasma chamber wall.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-loss and energy efficient modulation in silicon photonic waveguides by adiabatic elimination scheme

High-speed Silicon Photonics calls for solutions providing a small footprint, high density, and minimum crosstalk, as exemplified by the recent development of integrated optical modulators. Yet, the performances of such modulators are hindered by intrinsic material losses, which results in low energy efficiency. Using the concept of Adiabatic Elimination, here, we introduce a scheme allowing for the low-loss modulation in densely packed waveguides. Our system is composed of two waveguides, whose coupling is mediated by an intermediate third waveguide. The signal is carried by the two outer modes, while the active control of their coupling is achieved via the intermediate dark mode. The modulation is performed by the manipulation of the central-waveguide mode index, leaving the signal-carrying waveguides unaffected by the loss. We discuss how Adiabatic Elimination provides a solution for mitigating signal losses and designing relatively compact, broadband, and energy-efficient integrated optical modulators.

14 SOLAR ENERGY↗

Using the Principals of Electrochemistry to Understand and Overcome the Complicated Degradation Mechanisms of Silicon Anodes in Lithium-Ion Batteries [Slides]

Battery technology is the most significant problem facing widespread market adoption of battery electric vehicles (BEVs). The low energy density of state-of-the-art lithium-ion electrode materials leaves BEV owners and prospective buyers with lower ranges than a comparable internal combustion engine (ICE) vehicle, and vulnerable to a nascent fast charging network. Silicon has the potential to increase the anode energy density by nearly ten times compared to the incumbent material (graphite) and make BEVs a more competitive transportation option. However, lithiated silicon is extremely reactive towards components of the electrolyte and forms a heterogeneous, complicated, and dynamic solid at its surface known as the solid electrolyte interphase (SEI). Ideally, the SEI would passivate the silicon surface, but continuous chemical degradation persists even when the battery is not operating. This reactivity reduces silicon anode lifetimes well below the necessary standards for BEVs. The NREL-led Silicon Consortium Project is dedicated to understanding and solving these mechanisms of degradation. Here, I will discuss an electrochemical method that provides deep insights into the silicon interface during battery operation. I will link these observations to fundamental electrochemical principals and how they translate into actionable strategies that extend the lifetime of silicon anodes.

25 ENERGY STORAGE↗

Electrical Transfer Function and Poling Mechanisms for Nonlinear Optical Polymer Modulators

Electro-Optic Polymers hold great promise in increased electro-optic coefficients as compared to their inorganic corollaries. Many researchers have focused on quantum chemistry to describe how the dipoles respond to temperature and electric fields. Much work has also been done for single layer films to confirm these results. For optical applications, waveguide structures are utilized to guide the optical waves in 3 layer stacks. Electrode poling is the only practical poling method for these structures. This research takes an electrical engineering approach to develop poling models and electrical and optical transfer functions of the waveguide structure. The key aspect of the poling model is the large boundary charge density deposited during the poling process. The boundary charge density also has a large effect on the electrical transfer function which is used to explain the transient response of the system. These models are experimentally verified. Exploratory experiment design is used to study poling parameters including time, temperature, and voltage. These studies verify the poling conditions for CLDX/APC and CLDZ/APEC guest host electro optic polymer films in waveguide stacks predicted by the theoretical developments.

Watson, Michael Dale↗

DNA Extraction by Isotachophoresis in a Microfluidic Channel

Biological assays have many applications. For example, forensics personnel and medical professionals use these tests to diagnose diseases and track their progression or identify pathogens and the host response to them. One limitation of these tests, however, is that most of them target only one piece of the sample - such as bacterial DNA - and other components (e.g. host genomic DNA) get in the way, even though they may be useful for different tests. To address this problem, it would be useful to extract several different substances from a complex biological sample - such as blood - in an inexpensive and efficient manner. This summer, I worked with Maxim Shusteff at Lawrence Livermore National Lab on the Rapid Automated Sample Prep project. The goal of the project is to solve the aforementioned problem by creating a system that uses a series of different extraction methods to extract cells, bacteria, and DNA from a complex biological sample. Biological assays can then be run on purified output samples. In this device, an operator could input a complex sample such as blood or saliva, and would receive separate outputs of cells, bacteria, viruses, and DNA. I had the opportunity to work this summer with isotachophoresis (ITP), a technique that can be used to extract nucleic acids from a sample. This technique is intended to be the last stage of the purification device. Isotachophoresis separates particles based on different electrophoretic mobilities. This technique is convenient for out application because free solution DNA mobility is approximately equal for DNA longer than 300 base pairs in length. The sample of interest - in our case DNA - is fed into the chip with streams of leading electrolyte (LE) and trailing electrolyte (TE). When an electric field is applied, the species migrate based on their electrophoretic mobilities. Because the ions in the leading electrolyte have a high electrophoretic mobility, they race ahead of the slower sample and trailing electrolyte ions. Conversely, the trailing electrolyte ions have a slow electrophoretic mobility, so they lag behind the sample, thus trapping the species of interest between the LE and TE streams. In a typical isotachophoresis configuration, the electric field is applied in a direction parallel to the direction of flow. The species then form bands that stretch across the width of the channel. A major limitation of that approach is that only a finite amount of sample can be processed at once, and the sample must be processed in batches. For our purposes, a form of free-flow isotachophoresis is more convenient, where the DNA forms a band parallel to the edges of the channel. To achieve this, in our chip, the electric field is applied transversely. This creates a force perpendicular to the direction of flow, which causes the different ions to migrate across the flow direction. Because the mobility of the DNA is between the mobility of the leading and the trailing electrolyte, the DNA is focused in a tight band near the center of the channel. The stream of DNA can then be directed to a different output to produce a highly concentrated outlet stream without batch processing. One hurdle that must be overcome for successful ITP is isolating the electrochemical reactions that result from the application of high voltage for the actual process of isotachophoresis. The electrochemical reactions that occur around metal electrodes produce bubbles and pH changes that are detrimental to successful ITP. The design of the chips we use incorporates polyacrylamide gels to serve as electrodes along the central channel. For our design, the metal electrodes are located away from the chip, and high conductivity buffer streams carry the potential to the chip, functioning as a 'liquid electrode.' The stream then runs alongside a gel barrier. The gel electrode permits ion transfer while simultaneously isolating the separation chamber from any contaminants in the outer, 'liquid electrode' streams. The difference in potential from one side of the chip to the other creates an electric field. This field traverses the inner, separation channel, containing the leading electrolyte, the trailing electrolyte, and the sample of interest (DNA). To increase the ease of use of the chips, a newer chip design has been fabricated. This design has wire electrodes integrated on the chip, rather than elsewhere. To keep the pH changes and bubbling isolated from the separation channel, the chip contains deeper wells near the electrodes so that the flowing buffer can wash away any gases that form around the electrode. This design is significantly more compact because it eliminates the cumbersome electrode boxes. Eliminating the electrode boxes also decreases the required voltage, making the experiments safer. This happens because when the 'liquid electrode' streams travel through small diameter tubing, they lose much of their voltage due to the electrical resistance of the fluid in the tubing.

42 ENGINEERING↗

Particle Tracking Methods for Battery Precipitation Reactions

Precipitation and deposition reactions at solid–liquid interfaces play a key role in a number of battery chemistries, including Li-ion, so-called “anode free” batteries, zinc-based battery chemistries, and lithium–sulfur, among others. Although models with heterogeneous nucleation and growth phenomena are present in the literature, papers have not to date provided much detail on the numerical algorithms used to track the temporal evolution of the particle size distribution of deposits on electrode surfaces. In this paper we examine several approaches to discretize and track the particle size distribution, demonstrating that common approaches lead to anomalous flattening of the particle size distribution. We conclude by presenting an algorithm that preserves the appropriate particle size distribution during particle growth.

Algorithms↗