Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electron backscattering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

High Resolution Ozone Mapper (HROM)

Using the backscatter ultraviolet instrument (BUV) aboard NIMBUS 4 as a baseline, point scanner mechanisms and spatial multiplex scanning systems were compared on the basis of sensitivity, field of view and simplicity. This comparison included both spectral and spatial scanning and multiplexing techniques. The selected system which optimally met the performance requirements for a shuttle based instrument was a pushbroom spatial scanner using a 15 element photomultiplier tube array and a Hadamard multiplex spectral scan. The selected system was conceptually designed. This design includes ray traces of the monochromator, mechanical layouts and the electronic block diagram.

Kohr, J. R.↗

Laser velocimeter measurement of developing and periodic flows

The transmitting-receiving lens system of a two-component backscatter laser-velocimeter optical package currently in operation is discussed. It is basically a Galilean-type telescope which provides for spatial translation of the focal volume along the optical axis, but it also has certain optical constraints which are discussed. This scanning feature of the unit has been used with spectrum analyzer processing for the measurement of (1) trailing vortices in a wind tunnel and (2) a developing (decaying) vortex that was generated by towing a wing model through a water towing tank. The optical system has also been interfaced with period counting electronics and has been applied to the periodic flow generated by a model helicopter rotor. Results are presented and the techniques of data acquisition and the 'strobing' of the processor are discussed.

Orloff, K. L.↗

Colossal anisotropic absorption of spin currents induced by chirality

The chiral induced spin selectivity (CISS) effect, in which the structural chirality of a material determines the preference for the transmission of electrons with one spin orientation over that of the other, is emerging as a design principle for creating next-generation spintronic devices. CISS implies that the spin preference of chiral structures persists upon injection of pure spin currents and can act as a spin analyzer without the need for a ferromagnet. Here, we report an anomalous spin current absorption in chiral metal oxides that manifests a colossal anisotropic nonlocal Gilbert damping with a maximum-to-minimum ratio of up to 1000%. A twofold symmetry of the damping is shown to result from differential spin transmission and backscattering that arise from chirality-induced spin splitting along the chiral axis. These studies reveal the rich interplay of chirality and spin dynamics and identify how chiral materials can be implemented to direct the transport of spin current.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Investigation of electron dynamics in the magnetosphere with electron beams injected from sounding rockets

This paper describes an empirical study of the basic mechanisms by which electrons precipitate from the geomagnetic field to produce 'auroral X rays' during periods of geomagnetic activity. The study was based on data obtained by the Echo satellites. Echo I, launched in 1970, injected 40 keV, 0.1 amp electron pulses at low latitude (L ? 2.6) and successfully measured the returning pulses from the conjugate region. Electric fields and multiple Coulomb scattering were studied. Echo II, launched in 1972 from high latitude (L ? 8) studied the interaction of the beams with background radiation and the detailed motion of the beams near the rocket. Evidence for a beam plasma instability was obtained. Echo III launched in April 1974, (L ? 5.5) detected a series of conjugate echoes during the presence of a strong convective field in the magnetosphere. It was shown that the electric field measurement in the ionosphere using the incoherent backscatter radar and detectors on the rocket was transferred to the equatorial plane as though field lines were equipotentials.

Winckler, J. R.↗

Electron precipitation zones around major ground-based VLF signal sources

The spatial distribution of electron precipitation induced by VLF signals from ground-based transmitters is determined by using a test particle computer model of the gyroresonant wave-particle interaction (Inan et al., 1982). The results are presented as contours of energy flux on a map of the region around each transmitter. It is shown that the size of the precipitation zones is a strong function of the geographic location of the transmitter, as well as its radiated power and operating frequency. In general, the precipitation zones are much wider in longitude than in latitude and are oriented along lines of constant geomagnetic latitude. Assuming backscatter and/or wave echoing, precipitation zones around the points that are magnetically conjugate to the sources are also estimated. The results presented can be used to interpret satellite- or ground-based measurements of the precipitation induced by ground-based VLF transmitters.

Inan, U. S.↗

Exploratory study on microanalysis of thin films by backscattering techniques

Solid phase epitaxial growth of Si layers was studied by backscattering spectrometry for controllable electrical characteristics. Samples were fabricated by vacuum deposition on a thin layer of Sb before deposition of the amorphous Si layer. Analysis of the resulting SPEG layer showed that Sb was present in the SPEG layer of Si. The characteristic of the SPEG layer against the Si substrate was rectifying. A scanning microprobe picture of a cleaved sample established the presence of a depletion region more than 1 micron below the surface. Hall effect data indicated that the SPEG layer was n-type, with average free carrier concentration of about 10 to the 19th power cm/3 and average electron mobility of about 40 sq cm/Vs. SPEG with Pd silicide or Ni silicide transport layers showed fast initial transient growth regimes with slower growth in the steady state regimes.

Mayer, J. W.↗

Particle and fluid simulations of resistive current-driven electrostatic ion cyclotron waves

The results from 1-D numerical simulations of electrostatic ion cyclotron waves (EIC) are presented for a model in which the electrons are a resistive (collisional) fluid. Simulations of both the kinetic and fluid descriptions are performed and compared in order to assess the fundamental limitations of fluid theory for EIC waves. The effect of ion-neutral collisions is also included using a simple Monte Carlo technique. It is found that a small ion-neutral collision frequency destroys the frequency harmonic coupling of kinetic EIC waves and tends to validate the fluid description. The saturation amplitude of the current-driven EIC instability is in agreement with recent laboratory experiments. The coherent nature (extremely narrow spectral width) and phase velocity agree with ground based (coherent backscatter radars) and in situ observations of current-driven EIC waves in the high latitude ionosphere.

Seyler, Charles E.↗

The 2nd phase of the LEANDRE program: Water-vapor DIAL measurement

As a follow-on of the backscattered lidar, a differential absorption lidar (LEANDRE 2) is now being developed as part of the LEANDRE program for airborne meteorological studies. The primary measurement objective of LEANDRE 2 is water vapor. Pressure and temperature measurements are aimed at a second stage. The goals are to obtain a horizontal resolution of a few hundred meters for a vertical resolution of less than a hundred meters, with an absolute accuracy of 10 percent for humidity measurement. As compatibility is an important feature between the 2 first phases of LEANDRE, most of the LEANDRE 1 sub-system will be used and adapted for LEANDRE 2. For example, detection electronics, central computer, detectors and telescope will be the same. However, important modifications have to be done on the laser source, and spectral control has to be added. Most of the work is thus devoted to those developments, and the status is presented here.

Quaglia, P.↗

Linear operating region in the ozone dial photon counting system

Ozone is a relatively unstable molecule found in Earth's atmosphere. An ozone molecule is made up of three atoms of oxygen. Depending on where ozone resides, it can protect or harm life on Earth. High in the atmosphere, about 15 miles up, ozone acts as a shield to protect Earth's surface from the sun's harmful ultraviolet radiation. Without this shield, we would be more susceptible to skin cancer, cataracts, and impaired immune systems. Closer to Earth, in the air we breathe, ozone is a harmful pollutant that causes damage to lung tissue and plants. Since the early 1980's, airborne lidar systems have been used for making measurements of ozone. The differential absorption lidar (DIAL) technique is used in the remote measurement of O3. This system allows the O3 to be measured as function of the range in the atmosphere. Two frequency-doubled Nd:YAG lasers are used to pump tunable dye lasers. The lasers are operating at 289 nm for the DIAL on-line wavelength of O3, and the other one is operated at 300 nm for the off-line wavelength. The DIAL wavelengths are produced in sequential laser pulses with a time separation of 300 micro s. The backscattered laser energy is collected by telescopes and measured using photon counting systems. The photon counting system measures the light signal by making use of the photon nature of light. The output pulse from the Photo-Multiplier Tube (PE), caused by a photon striking the PMT photo-cathode, is amplified and passed to a pulse height discriminator. The peak value of the pulse is compared to a reference voltage (discrimination level). If the pulse amplitude exceeds the discrimination level, the discriminator generates a standard pulse which is counted by the digital counter. Non-linearity in the system is caused by the overlapping of pulses and the finite response time of the electronics. At low count rates one expects the system to register one event for each output pulse from the PMT corresponding to a photon incident upon the photocathode, however, at higher rates the limitations of the discrimination/counting system will cause the observed count rate to be non-linear with respect to the true count rate. Depending on the pulse height distribution and the discriminator level, the overlapping of pulses (pulse pile-up) can cause count loss or even an additional apparent count gain as the signal levels increase. Characterization of the system, including the pulse height distribution, the signal to noise ratio, and the effect of the discriminator threshold level, is critical in maximizing the linear operating region of the system, thus greatly increasing the useful dynamic range of the system.

Andrawis, Madeleine↗

Ozone depletion in the high latitude lower stratosphere - 1979-1990

Archived Stratospheric Aerosol and Gas Experiment (SAGE, SAGE II) and Solar and Backscattered Ultraviolet (SBUV) data are used to examine lower stratospheric O3 variations at 50 deg latitude in both hemispheres. These data indicate that from 1979 to 1985, 73-90 percent of the total O3 changes have occurred below approximately 25 km in altitude. Significant O3 depletions (up to 15 percent) have occurred in the partial column (127-15.8 mbar) in both hemispheres with indications of a recovery after 1985. Two-dimensional model simulations of O3 changes from 1979 to 1990 have been carried out. Comparisons with O3 data are presented. Model results suggest that by 1985, significant declines in global O3 were caused by destruction by odd nitrogen associated with long-term variations in the flux of precipitating relativistic electrons (2.6 percent); solar UV flux changes (1.8 percent); the dilution effect associated with the Antarctic O3 hole (1.2 percent); and atmospheric increases in CH4, N2O, and chlorofluorocarbons (0.4 percent). Analyses of drift-corrected SBUV and Total Ozone Mapping Spectrometer data and model calculations indicate that between 1979 and 1985, reductions of 4.3 to 4.8 percent in total column O3 averaged between 65 deg S and 65 deg N have occurred. Calculations indicate a full global O3 decline of 5.2 percent (peak-to-peak) or 6 percent (annual average) between 1979 and 1985 with a partial recovery between 1985 and 1989.

Callis, Linwood B.↗

Coherent lidar design and performance verification

The verification of LAWS beam alignment in space can be achieved by a measurement of heterodyne efficiency using the surface return. The crucial element is a direct detection signal that can be identified for each surface return. This should be satisfied for LAWS but will not be satisfied for descoped LAWS. The performance of algorithms for velocity estimation can be described with two basic parameters: the number of coherently detected photo-electrons per estimate and the number of independent signal samples per estimate. The average error of spectral domain velocity estimation algorithms are bounded by a new periodogram Cramer-Rao Bound. Comparison of the periodogram CRB with the exact CRB indicates a factor of two improvement in velocity accuracy is possible using non-spectral domain estimators. This improvement has been demonstrated with a maximum-likelihood estimator. The comparison of velocity estimation algorithms for 2 and 10 micron coherent lidar was performed by assuming all the system design parameters are fixed and the signal statistics are dominated by a 1 m/s rms wind fluctuation over the range gate. The beam alignment requirements for 2 micron are much more severe than for a 10 micron lidar. The effects of the random backscattered field on estimating the alignment error is a major problem for space based lidar operation, especially if the heterodyne efficiency cannot be estimated. For LAWS, the biggest science payoff would result from a short transmitted pulse, on the order of 0.5 microseconds instead of 3 microseconds. The numerically errors for simulation of laser propagation in the atmosphere have been determined as a joint project with the University of California, San Diego. Useful scaling laws were obtained for Kolmogorov atmospheric refractive turbulence and an atmospheric refractive turbulence characterized with an inner scale. This permits verification of the simulation procedure which is essential for the evaluation of the effects of refractive turbulence on coherent Doppler lidar systems. The analysis of 2 micron Doppler lidar data from Coherent Technologies, Inc. (CTI) has demonstrated many of the advantages of doppler lidar measurements of boundary layer winds. The effects of wind shear and wind turbulence over the pulse volume are probably the dominant source of the reduced performance. The effects of wind shear and wind turbulence on the statistical description of doppler lidar data has been derived and calculated.

Frehlich, Rod↗

Observations of Enhanced Radar Backscatter (ERB) from Millstone Hill

Intense enhancements of the incoherent radar backscatter spectrum from the topside ionosphere were observed with the Millstone Hill UHF radar. Enhancements occurring at the local ion acoustic frequency causing large asymmetries in the measured ion line may be produced by current driven instabilities. These enhancements pose a practical problem for space surveillance systems because their cross section and spectral width are characteristic of satellites. Conversely, their hard target signature complicates the study of naturally occurring ERB events; it is nearly impossible to distinguish them from satellites based on a single measurement. Statistical comparisons of observed coherent echo distributions with predictions from a satellite catalog were used to broadly identify periods of ERB activity. A series of experiments using multiple diagnostics, including satellite instruments, for simultaneous observations have established the association of ERB with large fluxes of soft suprathermal electrons carrying field aligned currents. Zenith data are also presented which show the asymmetric growth of ion acoustic waves directly above Millstone Hill. Details of these results are presented.

Lee, M. C.↗

Development of a Photon Counting System for Differential Lidar Signal Detection

Photon counting has been chosen as a means to extend the detection range of current airborne DIAL ozone measurements. Lidar backscattered return signals from the on and off-line lasers experience a significant exponential decay. To extract further data from the decaying ozone return signals, photon counting will be used to measure the low light levels, thus extending the detection range. In this application, photon counting will extend signal measurement where the analog return signal is too weak. The current analog measurement range is limited to approximately 25 kilometers from an aircraft flying at 12 kilometers. Photon counting will be able to exceed the current measurement range so as to follow the mid-latitude model of ozone density as a function of height. This report describes the development of a photon counting system. The initial development phase begins with detailed evaluation of individual photomultiplier tubes. The PMT qualities investigated are noise count rates, single electron response peaks, voltage versus gain values, saturation effects, and output signal linearity. These evaluations are followed by analysis of two distinctive tube base gating schemes. The next phase is to construct and operate a photon counting system in a laboratory environment. The laboratory counting simulations are used to determine optimum discriminator setpoints and to continue further evaluations of PMT properties. The final step in the photon counting system evaluation process is the compiling of photon counting measurements on the existing ozone DIAL laser system.

Elsayed-Ali, Hani↗

LASE validation experiment: preliminary processing of relative humidity from LASE derived water vapor in the middle to upper troposphere

Lidar Atmospheric Sensing Experiment (LASE) is the first fully engineered, autonomous airborne DIAL (Differentials Absorption Lidar) system to measure water vapor, aerosols, and clouds throughout the troposphere. This system uses a double-pulsed Ti:sapphire laser, which is pumped by a frequency-doubled flashlamp-pumped Nd: YAG laser, to transmit light in the 815 mn absorption band of water vapor. LASE operates by locking to a strong water vapor line and electronically tuning to any spectral position on the absorption line to choose the suitable absorption cross-section for optimum measurements over a range of concentrations in the atmosphere. During the LASE Validation Experiment, which was conducted over Wallops Island during September, 1995, LASE operated on either the strong water line for measurements in middle to upper troposphere, or on the weak water line for measurements made in the middle to lower troposphere including the boundary layer. Comparisons with water vapor measurements made by airborne dew point and frost point hygrometers, NASA/GSFC (Goddard Space Flight Center) Raman Lidar, and radiosondes showed the LASE water vapor mixing ratio measurements to have an accuracy of better than 6% or 0.01 g/kg, whichever is larger, throughout the troposphere. In addition to measuring water vapor mixing ratio profiles, LASE simultaneously measures aerosol backscattering profiles at the off-line wavelength near 815 nm from which atmospheric scattering ratio (ASR) profiles are calculated. ASR is defined as the ratio of total (aerosol + molecular) atmospheric scattering to molecular scattering. Assuming a region with very low aerosol loading can be identified, such as that typically found just below the tropopause, then the ASR can be determined. The ASR profiles are calculated by normalizing the scattering in the region containing enhanced aerosols to the expected scattering by the "clean" atmosphere at that altitude. Images of the total ASR clearly depict cloud regions, including multiple cloud layers, thin upper level cirrus, etc., throughout the troposphere. New data products that are being derived from the LASE aerosol and water measurements include: 1) aerosol extinction coefficient, 2) aerosol optical thickness, 3) precipitable water vapor, and 4) relative humidity (RH). These products can be compared with airborne in-situ, and ground and satellite remote sensing measurements,. This paper presents a preliminary examination of RH profiles in the middle to upper troposphere that are generated from LASE measured water vapor mixing ratio profiles coupled with rawinsonde profiles of temperature and pressure.

Brackett, Vincent G.↗

Enhancing the ATIC Charge Resolution

The Advanced Thin Ionization Calorimeter (ATIC) experiment measures the energy spectra of elements, from H to Fe, in the energy region from about 100 GeV to tens of TeV. The ATIC instrument was flown twice in long-duration balloon flights around the South Pole; the ATIC-1 test flight during Dec. 2000 - Jan. 2001 and the ATIC-2 science flight during Dec. 2002 - Jan. 2003. Analyses of both datasets have, to date, relied upon the highly segmented Silicon Matrix (SiM) detector to separate the incident cosmic ray from the calorimeter backscatter and to identify the charge. This method has worked well, enabling ATIC to separate protons from helium and to resolve all the major species up through iron. This charge resolution can be significantly improved by restricting the analysis to particle trajectories that pass through two SiM pixels at the cost of using only a fraction of the potential instrument geometry. However, immediately below the SiM is the two layer SI hodoscope (x, y) consisting of Bicron BC-408 plastic scintillator 2 cm wide, 1 cm thick, 88.2 cm long strips viewed by Hamamatsu R5611 photomultiplier tubes on each end of each strip. The primary purpose of the ATIC hodoscopes is to provide a fast trigger, and each hodoscope includes two crossed layers of strips (42 per layer in the case of Sl) providing supplemental particle trajectory information. The hodoscope readout electronics were designed to provide reasonable charge resolution over the dynamic range from protons through iron. This presentation discusses the S 1 hodoscope energy deposit calibrations, examines the charge resolution possible with this detector and investigates combining the S1 and SiM charge measurements to improve the overall ATIC charge resolution while minimizing degradation of the instrument geometry.

Guzik, T. G.↗

Dielectric Permittivity Measurements of Geologic Samples at Venus Surface Temperatures

Synthetic-aperture radar (SAR) and radar sounding are two powerful remote sensing techniques used to examine the surface and subsurface of planets. Their value is critical in the case of Venus due to this planet’s global and visually opaque cloud layer. The recently selected VERITAS and EnVision orbital missions, slated to study the planet in the early 2030’s, employ radar instruments to image the surface (VERITAS and EnVision) and probe the subsurface (EnVision). For both techniques, the complex dielectric permittivity of the surface and subsurface materials control radar backscatter intensity and penetration depth. Since the 1970’s, many studies have characterized the dielectric permittivity of geologic materials collected both on Earth and on the Moon to constrain the radar reflectivity and transparency at a variety of radar frequencies [e.g., 1]. Two consistent findings from those studies are that complex permittivity depends on both the density (or porosity) and the composition of the material. Denser materials and more metal-rich compositions tend to have higher permittivity values and to incur greater propagation path loss. Water content also elevates permittivity of otherwise dry rocks/soils/regolith [e.g., 2]. However, permittivity is independent of frequency for the 0.5-18 GHz range, within which SAR imaging commonly lies. The one aspect poorly explored thus far is the effect of elevated temperatures on dielectric permittivity. Previous work suggests that increased lattice vibrations and flow of free electrons associated with an increase in temperature elevate both the real (reflectivity) and imaginary (path loss) parts of the complex permittivity. We are currently conducting a 3-year campaign to measure the complex dielectric permittivity of Venusrelevant geologic materials at Venus surface temperatures (380°C - 460°C) and with frequencies relevant to VERITAS, EnVision, and Magellan imaging synthetic aperture radars.

M Barmatz↗

High-speed wide-angle interleaved scanning technique for a 3D imaging lidar

In this paper, we describe a novel interleaved scanner for an eye-safe 3D scanning lidar system to measure aerodynamic phenomena in a wind tunnel using elastic backscatter from seeding particles. The scanner assembly consists of a rotating polygon scanner for line scanning along the fast axis, a galvanometer (galvo) scanner for scanning along the slow axis, angular position sensors and motor controllers. The polygon scanner sweeps the lidar beam at up to 10,000 lines/s across a 27 deg angular field-of-regard in the fast axis, while the galvo scanner covers an angular range of 20 deg in the slow axis. Using this scanner, the lidar can perform non-intrusive flow visualization, velocimetry, and hard target mapping at mmscale spatial resolution to a standoff range of 5 m at an update rate of 50 Hz for the full field-of-regard. An interleaved scanning methodology for the acquisition of two snapshots of 3D lidar intensity data with a 100 μs time offset is discussed. The design of the control and data acquisition electronics is described. The effects of rapid scanning on the response of a narrow field-of-view lidar are addressed. The design of the scanner is scalable and can be tailored to meet the requirements of other applications by increasing or decreasing the standoff range, angular field-of-regard and scan rate.

3D Imaging Lidar↗

Decoupling of peeling and ballooning thresholds for pedestal stability and reduction in ELM frequency via enhanced turbulence with edge electron cyclotron heating in DIII-D

Abstract The edge localized mode (ELM) frequency ( f ELM ) decreased by 63% when electron cyclotron heating (ECH) deposition location is shifted from ρ = 0.4 to ρ = 0.8 in DIII-D discharges where the power ratio between neutral beam injection (NBI) and ECH ( P NBI / P ECH ) is kept at ∼1. The performance of the pedestal in the ECH heated case is compared with a pure NBI reference discharge while keeping the total input power constant. All these discharges are performed at balanced input torque conditions. Furthermore, in the pure NBI discharge a strong decoupling of the peeling–ballooning (PB) thresholds is observed. The PB decoupling is preserved when the ECH is deposited at ρ = 0.8 and P NBI / P ECH ∼ 1, while the thresholds manifest a closed stability boundary when the ECH is deposited at ρ = 0.4. The inter-ELM pedestal recovery time is considerably larger for the ECH at ρ = 0.8 case. Increased pedestal turbulence is observed in beam emission spectroscopy (BES), Doppler backscattering and magnetic diagnostics for the ECH at the ρ = 0.8 case. Strong growth of a TEM-like mode is observed in BES and the mode growth is correlated with the decrease in f ELM . In view of these observations, the increased pedestal turbulence seems to be the plausible reason behind the delayed pedestal recovery following an ELM event in the ECH at ρ = 0.8 case, and the preservation of PB decoupling through temperature pedestal profile widening. TRANSP interpretative simulations show that the ECH at the ρ = 0.8 case is more susceptible to ITG/TEM turbulence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗