Special radio frequency test on Apollo standard initiator Final technical report
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
A brief review of mean-square approximate systems is given. The case in which the masses are deterministic is considered first in the derivation of an estimator for the upper bound of the standard deviation of a natural frequency. Two examples presented include a two-degree-of-freedom system and a case in which the disorder in the springs is perfectly correlated. For purposes of comparison, a Monte Carlo simulation was done on a digital computer.
The standard ECG is by convention limited to 0.05-150 Hz, but higher frequencies are also present in the ECG signal. With high-resolution technology, it is possible to record and analyze these higher frequencies. The highest amplitudes of the high-frequency components are found within the QRS complex. In past years, the term "high frequency", "high fidelity", and "wideband electrocardiography" have been used by several investigators to refer to the process of recording ECGs with an extended bandwidth of up to 1000 Hz. Several investigators have tried to analyze HF-QRS with the hope that additional features seen in the QRS complex would provide information enhancing the diagnostic value of the ECG. The development of computerized ECG-recording devices that made it possible to record ECG signals with high resolution in both time and amplitude, as well as better possibilities to store and process the signals digitally, offered new methods for analysis. Different techniques to extract the HF-QRS have been described. Several bandwidths and filter types have been applied for the extraction as well as different signal-averaging techniques for noise reduction. There is no standard method for acquiring and quantifying HF-QRS. The physiological mechanisms underlying HF-QRS are still not fully understood. One theory is that HF-QRS are related to the conduction velocity and the fragmentation of the depolarization wave in the myocardium. In a three-dimensional model of the ventricles with a fractal conduction system it was shown that high numbers of splitting branches are associated with HF-QRS. In this experiment, it was also shown that the changes seen in HF-QRS in patients with myocardial ischemia might be due to the slowing of the conduction velocity in the region of ischemia. This mechanism has been tested by Watanabe et al by infusing sodium channel blockers into the left anterior descending artery in dogs. In their study, 60 unipolar ECGs were recorded from the entire ventricular surface and were signal-averaged and filtered in the 30-250 Hz frequency range. The results showed that the decrease noted in the HF-QRS correlated linearly with the local conduction delay. The results suggest that HF-QRS is a potent indicator of disturbed local conduction. An alternative theory is that HF-QRS reflect the shape of the original electrocardiographic signal. Bennhagen et al showed that root mean square (RMS) voltage values of the depolarization signal correlate poorly with the signal amplitude but highly with the first and second derivatives, i.e. the velocity and the acceleration of the signal. It has also been suggested that the autonomic nervous system affects HF-QRS. For example, sitting up causes significant changes in HF-QRS in some leads compared to the supine position [Douglas et al., 2006]. Unpublished results indicate that familial dysautonomic patients (both vagal and sympathetic degeneration) have very little Reduced Amplitude Zones (RAZ) formation . Athletic individuals, especially elite athletes, who have vagally-mediated changes on the conventional ECG (i.e. early repolarization, bradycardia) have increased RAZ formation. Further electrophysiological studies are needed, however, to better understand the underlying mechanisms of HF-QRS. Several investigators have studied HF-QRS in different cardiac conditions, including acute myocardial ischemia and myocardial infarction (MI). However, in order for clinicians to confidently use HF-QRS as an adjunct to standard ECG, more knowledge about the characteristics of HF-QRS is needed.
Traditionally, bowtie antennas have been known to exhibit wide impedance characteristics, omnidirectional radiation patterns, and linear polarization. There is a broad range of applications from medical imaging, archaeological survey, and Ground Penetrating Radar (GPR) to trackers and sensor networks where wideband bowtie antenna designs are required for their operations. Broadening the bandwidth of bowtie antenna requires widening the flare angle of the bowtie arms, which consequently results in a large surface area that may not be suitable for space-constrained applications. Moreover, drawback attributes of the wideband bowtie designs feature inconsistent radiation pattern across the bandwidth and low signal-to-noise (SNR) ratios. As it is known, the SNR would be improved in dual- or multi-band antennas due to their reduced bandwidth. To this end, dual-band/multi-band antennas are preferred over wideband antennas in applications where more than a single frequency of interest is present. Previously, a two-port double-dipole elements was reported, whose arms were orthogonally interleaved to facilitate operation in both the standard WLAN frequency bands (J. M. Steyn and et. al, Progress in Electromagnetic Research, Vol. – 10 pp. 151-161). Even though the antenna is not very compact it does exhibit good cross-polarization, moderate gain in both frequency bands. Another dual-band bowtie antenna which excites two bands using a single transmission line was reported (Wen Chao Zheng and et. al, IEEE Trans. Antennas propag., 2014). The design was compact and did not need multi-port feeding network. In this paper, a dual-band compact bowtie antenna operating at 900 MHz (RF band) and 2.45 GHz (ISM band) using a single excitation port is introduced. It is printed on a 1.54mm thick dielectric substrate (εr = 3.38). The antenna consists of two sets of bowtie arms, a microstrip transmission line to feed the bowtie arms, and a ground plane acting as a reflector to partially reduce the back radiation. One of the bowtie arms of each frequency is printed on the top layer and the other arm, which is mirror imaged, is printed on the bottom layer of the substrate. The length of the bowtie controls the resonance frequency of the antenna and the flare angle controls the bandwidth of the antenna. The microstrip transmission line, connected to a 50 Ω SMA probe, feeds the bowtie antenna. The compact antenna can be used for both RF and ISM band applications. The bowtie arms at the lower frequency band are miniaturized by elongating their electrical lengths. The influence of miniaturizing the bowtie arms and the supporting partial ground plane is observed in the reduced peak gain and degraded front-to-back ratio. These are partly neutralized using four quarter-wave choke-slots in the ground plane with two on each side of the feeding transmission line. The proposed antenna is numerically investigated and finalized by the finite-element based full-wave EM solver, ANSYS HFSS. The miniaturization has reduced the ground plane size by ~45% and the arms size by ~41%. In addition to the size reduction benefits, the antenna shows reasonable peak gain and front-to-back ratio in both the bands. The corresponding results will be presented and discussed at the conference.
Over the past decade, trapped ion atomic clock development at the Jet Propulsion Laboratory (JPL) has focused on two directions: 1) new atomic clock technology for space flight applications that require strict adherence to size, weight, and power requirements, and 2) ultra-stable atomic clocks, usually for terrestrial applications emphasizing ultimate performance. In this paper we present a new ultra-stable trapped ion clock designed, built, and tested in the second category. The first new standard, L10, will be delivered to the Naval Research Laboratory for use in characterizing DoD space clocks.
A standard radio frequency coaxial connector is modified so that a plastic insulating sleeve can be mounted in the wall of a vacuum chamber. This eliminates ground loops and interference from cable connections.
Photobeat characteristics between two independently stabilized He-Ne lasers
Frequency stabilization of double mode helium-neon laser via phase lock circuit
A method has been presented for estimating the variability of a system's natural frequencies arising from the variability of the system's parameters. The only information required to obtain the estimates is the member variability, in the form of second-order properties, and the natural frequencies and mode shapes of the mean system. It has also been established for the systems studied by means of Monte Carlo estimates that the specification of second-order properties is an adequate description of member variability.
An aircraft crash location transmitter tuned to transmit on standard emergency frequencies is reported that is shock mounted in a sealed circular case atop the tail of an aircraft by means of a shear pin designed to fail under a G loading associated with a crash situation. The antenna for the transmitter is a metallic spring blade coiled like a spiral spring around the outside of the circular case. A battery within the case for powering the transmitter is kept trickle charged from the electrical system of the aircraft through a break away connector on the case. When a crash occurs, the resultant ejection of the case from the tail due to a failure of the shear pin releases the free end of the antenna which automatically uncoils. The accompanying separation of the connector effects closing of the transmitter key and results in commencement of transmission.
This paper presents experimental and theoretical comparisons of three control laws applied to a complex laboratory structure. A reduced finite element model was generated for designing the control systems and then corrected based on measured mode shapes and frequencies. A standard time-invariant linear quadratic regulator with state estimation was investigated first. Two simple direct rate feedback control laws both guaranteeing stability were also designed using the reduced model. One minimizes the maximum control force and the other minimizes the same quadratic performance index as the linear quadratic regulator. The three control laws have comparable performance indices with the direct rate feedback designs having better spillover properties. Experimental results for all designs were obtained with digital implementation. It was shown that the performance of the control system designed on the basis of the corrected finite element model agreed better with experimental results than the performance of the control system designed on the basis of the uncorrected model.
Assembly of the Space Station requires numerous construction flights by the Space Shuttle. A particularly challenging problem is that of control of each intermediate station configuration when the shuttle orbiter is approaching it to deliver the next component. The necessary braking maneuvers cause orbiter thruster plumes to impinge on the station, especially its solar arrays. This in turn causes both overall attitude errors and excitation of flexible-body vibration modes. These plume loads are predicted to lead to CMG saturation during the approach of the orbiter to the SC-5 station configuration, necessitating the use of the station RCS jets for desaturation. They are also expected to lead to significant excitation of solar array vibrations. It is therefore of great practical importance to investigate the effects of plume loads on the flexible dynamics of station configuration SC-5 as accurately as possible. However, this system possesses a great many flexible modes (89 below 5 rad/s), making analysis time-consuming and complicated. Model reduction techniques can be used to overcome this problem, reducing the system model to one which retains only the significant dynamics, i.e. those which are strongly excited by the control inputs or plume disturbance forces and which strongly couple with the measured outputs. The particular technique to be used in this study is the subsystem balancing approach which was previously developed by the present investigator. This method is very efficient computationally. Furthermore, it gives accurate results even for the difficult case where the structure has many closed-spaced natural frequencies, when standard modal truncation can give misleading results. Station configuration SC-5 is a good example of such a structure.
Year 1 progress can be characterized with four major achievements which are crucial toward the development of robust, easy to use antenna analysis code on doubly conformal platforms. (1) A new FEM code was developed using prismatic meshes. This code is based on a new edge based distorted prism and is particularly attractive for growing meshes associated with printed slot and patch antennas on doubly conformal platforms. It is anticipated that this technology will lead to interactive, simple to use codes for a large class of antenna geometries. Moreover, the codes can be expanded to include modeling of the circuit characteristics. An attached report describes the theory and validation of the new prismatic code using reference calculations and measured data collected at the NASA Langley facilities. The agreement between the measured and calculated data is impressive even for the coated patch configuration. (2) A scheme was developed for improved feed modeling in the context of FEM. A new approach based on the voltage continuity condition was devised and successfully tested in modeling coax cables and aperture fed antennas. An important aspect of this new feed modeling approach is the ability to completely separate the feed and antenna mesh regions. In this manner, different elements can be used in each of the regions leading to substantially improved accuracy and meshing simplicity. (3) A most important development this year has been the introduction of the perfectly matched interface (PMI) layer for truncating finite element meshes. So far the robust boundary integral method has been used for truncating the finite element meshes. However, this approach is not suitable for antennas on nonplanar platforms. The PMI layer is a lossy anisotropic absorber with zero reflection at its interface. (4) We were able to interface our antenna code FEMA_CYL (for antennas on cylindrical platforms) with a standard high frequency code. This interface was achieved by first generating equivalent magnetic currents across the antenna aperture using the FEM code. These currents were employed as the sources in the high frequency code.
Explore the source record for details and available documents.
The PARCS experiment will use a laser-cooled cesium atomic clock operating in the microgravity environment aboard the International Space Station to provide both advanced tests of gravitational theory to demonstrate a new cold-atom clock technology for space.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.