High-Moisture Diet for Laboratory Rats: Complete Blood Counts, Serum Biochemical Values, and Intestinal Enzyme Activity

Rats were fed an irradiated high-moisture diet (KSC-25) with or without access to a water bottle. Physiologic values were compared between these two groups and a group of rats fed a purified diet. Hematologic and serum biochemical values, urine specific gravity, and intestinal enzyme activities were determined from samples collected from the three groups of rats. Sprague Dawley rats (n=32) fed the irradiated high-moisture diet with or without a water bottle were the test animals. Rats (n=16) fed an irradiated purified diet and water provided via a water bottle were the control group. The purified diet formulation, modified AIN-76A, is a commonly used purified diet for laboratory rodents. All rats remained alert and healthy throughout the study. A comparison of the physiologic values of rats in this study with reported normal values indicated that all of the rats in the study were in good health. Significant differences (P less than 0.05) of the physiologic values from each rat group are reported.

Battles, August H.↗

Machine Learning based Correlation of the Mechanical Properties of Sub-sized and Standard-sized Specimens

Mechanical testing with sub-sized specimens is essential in the nuclear industry, offering the ability to conduct tests in confined spaces with lower irradiation and expediting material qualification. However, smaller specimens exhibit different material behavior across scales, a phenomenon known as the "specimen size effect". In this study, we compiled over 1,000 tensile testing records, covering 54 parameters such as material type, composition, manufacturing details, irradiation conditions, specimen dimensions, and tensile properties through a comprehensive literature review. We focus on correlating sub-sized and standard specimens’ tensile mechanical properties on SS316 alloy, which has the most extensive dataset available. We explore ML-based models and uncertainty quantification for tensile properties, analyze key factors influencing these properties, and compare the effectiveness of ML models with existing analytical methods in addressing the specimen size effect.

tensile properties↗

Fuel Performance Evaluation of THOR-C Experiments

The Temperature Heatsink Overpower Response Commissioning (THOR-C) and THOR-Metal (THOR-M) experiments will be performed as part of an ongoing project for testing sodium fast reactor fuels with the Japan Atomic Energy Agency (JAEA). The THOR-C experiments consist of fresh metallic fuel pins and have been analyzed using the ABAQUS, Ansys codes and the BISON fuel performance code. THOR-M-Loss of Flow-1 (THOR-M-LOF-1) is designed to test an EBR-II irradiated fuel pin under LOF conditions. Simulation of the THOR-MLOF-1 experiment required first simulating the base irradiation of the fuel pin in EBR-II. MFUEL module of SAS4A/SASSYS-1 [1] is a physics-based metallic fuel performance model applicable to the normal operation, transient scenarios and fuel failure modeling including scenarios with bulk fuel melting. The model has been validated using EBR-II normal operation, separate effect transient tests as well as TREAT M-Series transient tests [2]. In this study, MFUEL models has been utilized together with a new capsule heat transfer model developed in this project. The new heat transfer model was necessary due to (1) significant amount of heat losses that required 2D heat transfer, (2) the presence of a titanium heat sink, rejecting a significant amount of heat, and (3) stagnant coolant conditions, which are inconsistent with SAS4A/SASSYS-1 (SAS) heat transfer model. Updates to SAS4A/SASSYS-1 and MFUEL has been described below, followed by a preliminary validation effort using the results from THOR-C-2 fresh fuel capsule experiment. A previous study for THOR-C-2 analysis using BISON code is also utilized in this study to model this test [3]. [1] D. O’Grady, A. J. Brunett, L. Ibarra, A. Karahan, T. Kim, T. S. Sumner, R. Thomas, T. H. Fanning, “The SAS4A/SASSYS-2 Version 5.7 Safety Analysis Code System,” Argonne National Laboratory,ANL/NSE-SAS/5.7, (2023). [2] A. Karahan, T. Kim, T. Fanning, D. O’Grady, “Validation of MFUEL Metal Fuel Performance Models of SAS4A/SASSYS-1,” Argonne National Laboratory, ANL/NSE-23/11, (2023). [3] M. Mihelish, A. Zabriskie, K. Paaren, P. Medvedev, C. Jensen, “Fuel Performance Predictions for the TREAT THOR-C Experiments,” Idaho National Laboratory, INL/RPT-23-73397, Revision 0, (2023)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sulfate Conversion of Reillex HPQ Anion Exchange Resin for Disposal (Interim Report)

This report describes preliminary data to validate the Savannah River Plutonium Processing Facility’s (SRPPF) flowsheet for conversion of used Reillex HPQ anion exchange resin from the nitrate form to the sulfate form. The nitrate form is an oxidizer and therefore does not meet acceptance criteria for disposal at the Waste Isolation Pilot Plant (WIPP). The purpose of this study is to develop data to support acceptance for this disposition pathway. Due to the challenges characterizing the nitrate concentration on solid resin, the data developed to date are based upon indirect analysis of the ion exchange column effluent by ion chromatography. These challenges are discussed and two methods for quantification of nitrate directly on the resin are recommended for further development: TGA-MS and permanganate digestion followed by IC. The resin used for this work was provided in the chloride form; this is the form in which resin is supplied by the manufacturer. However, it had to be converted to the nitrate form, which is the form that will be used in SRPPF’s ion exchange process, prior to use in the sulfate conversion experiments. The chloride-form resin was characterized. A lab-scale procedure for the conversion of Reillex HPQ resin from the chloride to nitrate form was validated. The nitrate-form resin was assessed for particle size and chloride concentration to ensure it met SRPPF’s facility specifications. The baseline sulfate conversion flowsheet was tested. However, nitrate was still detectable in the effluent after approximately 10 bed volumes of 1 M sodium sulfate had been passed through the resin bed. Additional experiments were performed to assess the effect of increasing the feed volume, reducing the flowrate, the use of 2 M sulfuric acid instead of sodium sulfate, and the use of irradiated resin. The sulfuric acid test was the only one which provided a nondetectable nitrate concentration (<0.002 M) in the effluent. Detectable nitrate in the column effluent suggests that nitrate is still present on the resin itself.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design, Calibration, and Application of A Cryogenic Low-Background Infrared Radiometer for Spectral Irradiance and Radiance Measurements From 4- to 20-μm Wavelength

We have constructed, calibrated, and tested a cryogenic low-background infrared (IR) radiometer for both spectral radiance and irradiance measurements over the 4- to 20-μm wavelength range. The primary purpose of the Missile Defense Transfer Radiometer (MDXR) is to measure absolute irradiance or radiance from cryogenic IR test chamber sources using a photoconductive Si:As blocked-impurity band (BIB) detector and a set of spectral filters. The MDXR also includes an absolute cryogenic radiometer (ACR) and a Fourier-transform spectrometer (FTS). For irradiance measurements, the ACR is used to provide the primary power scale for the BIB detector in conjunction with spectral filters, whereas the FTS/BIB configuration derives its scale from an internal blackbody source. The two measurement scales show agreement for the irradiance of highly collimated (<1 mrad) IR beams from 10 -13 to 10 -8 W / μm / cm 2 within the combined relative uncertainties of 2.6% (coverage factor k = 1.) We have also calibrated the radiometer for radiance measurements using a large cavity fluid bath blackbody that overfills the spatial and angular extent of the radiometer entrance pupil. The radiometric calibration uncertainty analysis of the radiometer and its maintenance and stability are discussed.

radiometry↗

Testing of solar cell covers and encapsulants conducted in a simulated space environment

The materials included in the evaluation were 0211 micro-sheet, FEP-A used as a cover and as an adhesive, DC 93-500 adhesive, PFA "hard coat" used as a cover, GE 615/UV-24 used as a cover, GR 650 used as a cover, and electrostatically bonded 7070 glass. The test environments were 1 MeV electron irradiation interspersed with thermal cycling, 0.5 MeV proton irradiation interspersed with thermal cycling and UV exposure interspersed with thermal cycling. Summary data is given describing the response of the test materials both visually and electrically to the three different environments.

Russell, D. A.↗

Jellyfish: Special Tools for Biological Research on Earth and in Space

The most intriguing nature of the jellyfish polyps is their ability to metamorphose, giving rise to tiny immature medusae called ephyrae which have a different form or shape from the polyps. The Aurelia Metamorphosis Test System was used to determine the subtle effects of hydrocarbons found in oil spills and the effects of X-irradiation on developing ephyrae. Currently, this test system is used to determine the effects of the gravity-less environment of outer space on the development and behavior of ephyrae. For this purpose, the effects of clinostat rotation on development of the ephyrae and their gravity receptor are being studied. The behavior of the ephyrae during 0 gravity achieved for short intervals of 30 seconds in parabolic flight is examined. The developing ephyrae and the mature ephyrae are exposed to gravity-less environment of outer space via a six or seven day shuttle experiment. If gravity receptors do form in outer space, they will be studied in detail using various types of microscopes, including the electron microscope, to determin whether they developed normally in space as compared with control on Earth.

Spangenberg, Dorothy B.↗

Enhancing Post-Irradiation Examination (PIE) Efficiency with High-Throughput Experiments

Nuclear materials testing is essential for understanding changes in reactor environments, but traditional methods are costly and time-consuming. High-Throughput Experimentation (HTE) enables rapid screening and optimization of material properties by significantly increasing the number of specimens in the experiment. In this work, HTE methods were employed to irradiate novel materials at the Advanced Test Reactor (ATR) at Idaho National Laboratory. A total of 367 sub-sized tensile specimens were irradiated using the standard capsule design. To facilitate HTE, automated systems such as the Automated Mechanical Testing System were implemented for mechanical testing within hot cell environments, thereby reducing the need for manual interaction with hot cell manipulators and significantly lowering both the cost and duration of experiments. Digital image correlation (DIC) was used to measure displacement during mechanical testing, providing precise, non-contact measurement capabilities. The methodologies developed in this research will support the advancement of HTE techniques for future nuclear materials testing experiments at ATR. This approach allows for more efficient and cost-effective evaluation of new materials, ultimately leading to improved reactor performance, enhanced safety, and extended longevity within the nuclear industry.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Dose rate effects in MOS microcircuits

Three read/write random access memories, AM91L24, HM1-6514, and MWS 5114, were subjected to total dose irradiation at three dose rates, with electrical testing after each increment of dosage. Annealing measurements were performed after the radiation tests were completed. The AM91L24 showed a strong dose rate effect and substantial post-irradiation annealing of radiation-induced damage. The dose rate effect was that a lower dose rate produced less net damage than an eqivalent total dose applied at a higher rate. The HM1-6514 showed essentially no dose rate effect and no annealing damage, and the MWS 5114 exhibited a moderate effect with some annealing. It was concluded that dose rate is an important parameter in radiation test procedures for MOS microcircuits and that annealing measurements may be important evaluation aids for such tests.

Cleveland, D. G.↗

Total integrated dose testing of solid-state scientific CD4011, CD4013, and CD4060 devices by irradiation with CO-60 gamma rays

The total integrated dose response of three CMOS devices manufactured by Solid State Scientific has been measured using CO-60 gamma rays. Key parameter measurements were made and compared for each device type. The data show that the CD4011, CD4013, and CD4060 produced by this manufacturers should not be used in any environments where radiation levels might exceed 1,000 rad(Si).

Dantas, A. R. V.↗

Passive Temperature Sensors for Nuclear Applications

Thermocouples are generally used to provide real-time temperature indications in instrumented tests performed at material and test reactors. Passive temperature monitors, such as Silicon Carbide (SiC) and melt wires, may be included in such tests as an independent technique of detecting peak temperatures experienced during irradiation. In less expensive static (drop-in) capsule tests, which have no leads attached for real-time data transmission, melt wires, and SiC temperature monitors (TMs) are essentially the only possibility for peak temperature indication. A melt wire involves placing materials (wires) of a known composition and melting temperature in a test. An inventory is maintained at Material Science Laboratory (MSL) for melt wires ranging in temperatures from 30°C to 1500°C. Unfortunately, melt wires are limited in that it can only detect whether a single temperature is or is not exceeded (melt wire melted or not). SiC TMs, which can also be used to detect peak irradiation temperatures, are advantageous because a single monitor can allow to determine the peak temperature reached within a relatively broad range (100 – 1200°C) resulting in accuracies within ±20°C. Irradiation temperature is determined by measuring a property change after isochronal annealing or during a continuously monitored annealing process using specialized equipment at MSL. Recent research has produced a passive monitor known as sublime temperature monitor. This passive sensor has the capability of recording temperature gradients and pinpointing exactly where a temperature is located along that gradient. Long measurement lengths are achieved with very high accuracy in the location of desired temperature measurements (±2 mm over a 1 m span); however, this sensor has not been deployed in a nuclear reactor. This article will focus only on passive temperature sensors currently being researched and implemented under the Advanced Sensors and Instrumentation (ASI) program at Idaho National Laboratory (INL).

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Installation and Demonstration of CNC Machining for Mechanical Test Specimens in the IFEL Hot Cell

This report documents the installation and demonstration of computer numerical control (CNC) machining capabilities in the Irradiated Fuels Examination Laboratory hot cell facility at Oak Ridge National Laboratory (ORNL). A modified Tormach PCNC 440 mill was integrated into the hot cell with custom fixturing, fines management, and manipulator-compatible interfaces to enable the fabrication of axial tension test (ATT) and ring tension test (RTT) specimens from irradiated cladding. The first irradiated specimens machined included ATT and RTT geometries harvested from the high-burnup 6XV fuel rod. Dimensional inspections confirmed that machined specimens met the ±0.025 mm tolerance envelope established in prior development; deviations were consistent with expected measurement scatter and inherent specimen variability, such as wall thickness gradients and eccentricity. Comparisons with out-of-cell metrology confirmed that in-cell machining performance aligns with baseline scatter observed under ideal conditions. This work establishes reproducible, end-to-end specimen preparation at ORNL, directly supporting the US Department of Energy’s Accident-Tolerant Fuel program by enabling reliable, traceable mechanical testing of irradiated cladding.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fuel-Cladding Eutectic Study of Legacy Fast Flux Test Facility (FFTF) MFF HT9/U-10Zr Metallic Fuel

This report presents the first systematic investigation of fuel-cladding eutectic interaction (FCEI) in irradiated HT9/U-10Zr metallic fuel from the Fast Flux Test Facility (FFTF) Materials Fuels Form (MFF) program, using differential scanning calorimetry (DSC) coupled with scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS). Two irradiated fuel cross-sections, MNT07H (9.5 at% burnup, x/L = 0.78) and MNT08H (7.0 at% burnup, x/L = 0.93), were subjected to three successive isothermal annealing rounds (R1–R3) at 820°C for 20 minutes each, yielding a cumulative transient duration of one hour. This study directly addresses a recognized gap in the existing FCEI database, which previously lacked irradiated HT9/U-10Zr data at burnup levels above 8 at%. Two principal findings emerge from the study. First, for both samples, FCEI remained spatially confined within the pre-existing fuel-cladding chemical interaction (FCCI) zone boundaries after R3, with no measurable eutectic penetration into unaffected cladding beyond the original FCCI layer. This self-limiting behavior is consistent with historical Fuel Behavior Test Apparatus (FBTA) results and is attributed to the near-eutectic phase composition of the FCCI zone, which rapidly absorb the available eutectic-forming constituents and then stall penetration once the FCCI zone is consumed. A comparison with unirradiated surrogate data further supports this mechanism: whereas a U–34 at.% Fe sample would be expected to show ~176 µm of iron penetration under comparable conditions, the irradiated samples exhibited only ~20 µm, a discrepancy attributed to irradiation-induced interfacial porosity and pre-existing FCCI composition gradients. Second, for MNT08H, FCEI was observed exclusively on the half of the cladding circumference where pre-existing steady-state FCCI was present, with no detectable FCEI on the opposite half. Three hypotheses are proposed to explain this asymmetry: the inhibiting role of a zirconium-rich rind at the fuel-cladding interface; the chemical sequestration of iron by redistributed zirconium within the fuel matrix; and the persistence of fuel-cladding gaps on the FCEI-free half that preclude direct contact. All three hypotheses require further experimental investigation. The results extend the empirical FCEI database into higher-burnup territory and demonstrate the viability of DSC-based testing as a substitute for the no-longer-available FBTA apparatus. Future work will include additional cross-section testing, compilation of the full FCEI dataset, model evaluation, and DSC testing of ternary fuel compositions to broaden the experimental basis for safety assessment of sodium-cooled fast reactor systems.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Overview of IMPACT Data Acquisition System and Data Reduction Process

This report documents the development of the data acquisition system (DAS) and data reduction methodologies for the Irradiated Material Property Accelerated Characterization Test (IMPACT) experiment at the Advanced Test Reactor (ATR). The IMPACT experiment is designed to enable in-pile measurement of thermal conductivity in metallic nuclear fuels, specifically U-10Zr, using an instrumented thermal conductivity probe. The DAS supports both passive temperature monitoring and active thermal interrogation of the probe through controlled AC and DC excitation. Significant modifications to laboratory-scale systems were required to accommodate the higher resistance paths associated with the in-pile application. Custom electronics and relay-controlled measurement sequencing were developed to enable the measurement and sufficient power delivery to the sensing region. A reduced-order, axisymmetric thermal model based on the thermal quadrupoles method is presented to support data interpretation. This model enables efficient evaluation of transient heat transfer behavior and facilitates solution of the inverse problem required to extract thermal properties from measured signals. Multiple boundary condition formulations are discussed to address varying experimental time scales and geometries. Additionally, machine learning techniques are introduced to support data reduction and improve confidence in inverse solutions. Convolutional neural networks are applied to identify the presence of gas gaps and other evolving geometric features that significantly impact thermal response during irradiation. These efforts contribute to the broader integration of digital twin frameworks and real-time modeling capabilities within the Advanced Fuels Campaign.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Variation in spectral irradiance of the SES solar simulator

A test to determine the spectral characteristics of the solar simulation produced by the solar environment simulator (SES) comprised a statistical analysis to determine the spectral variance, and its effect on the average absorptivity of surface coatings.

Mcnutt, A. E.↗

The effects of space radiation on a chemically modified graphite-epoxy composite material

The effects of the space environment on the engineering properties and chemistry of a chemically modified T300/934 graphite-epoxy composite system are characterized. The material was subjected to 1.0 x 10 to the 10th power rads of 1.0 MeV electron irradiation under vacuum to simulate 30 years in geosynchronous earth orbit. Monotonic tension tests were performed at room temperature (75 F/24 C) and elevated temperature (250 F/121 C) on 4-ply unidirectional laminates. From these tests, inplane engineering and strength properties (E sub 1, E sub 2, Nu sub 12, G sub 12, X sub T, Y sub T) were determined. Cyclic tests were also performed to characterize energy dissipation changes due to irradiation and elevated temperature. Large diameter graphite fibers were tested to determine the effects of radiation on their stiffness and strength. No significant changes were observed. Dynamic-mechanical analysis demonstrated that the glass transition temperature was reduced by 50 F(28 C) after irradiation. Thermomechanical analysis showed the occurrence of volatile products generated upon heating of the irradiated material. The chemical modification of the epoxy did not aid in producing a material which was more radiation resistant than the standard T300/934 graphite-epoxy system. Irradiation was found to cause crosslinking and chain scission in the polymer. The latter produced low molecular weight products which plasticize the material at elevated temperatures and cause apparent material stiffening at low stresses at room temperature.

Reed, S. M.↗

Qualification of an Additively Manufactured Irradiation Capsule for the High Flux Isotope Reactor

As part of the Advanced Materials and Manufacturing Technologies (AMMT) Program’s work package Component Manufacturing and Demonstrations from AM 316 SS, irradiation capsules have been additively manufactured (AM) from 316H stainless steel for insertion into the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL). The irradiation capsules (commonly referred to as “rabbits”) have been successfully designed, fabricated, pressure tested, qualified, and inserted into the HFIR for irradiation and post-irradiation evaluation. Each rabbit consists of an AM housing and two standard AM end caps. The design is simple and amenable to geometric and material customization. This demonstration helps pave the way for acceptance of AM safety-critical components for nuclear energy applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Simulated Space Environmental Testing on Thin Films

An exploratory program has been conducted, to irradiate some mature commercial and some experimental polymer films with radiation simulating certain Earth orbits, and to obtain data about the response of each test film's reflective and tensile properties. Protocols to conduct optimized tests were considered and developed to a "prototype" level during this program. Fifteen polymer film specimens were arranged on a specially designed test fixture. The fixture featured controlled exposure areas, and protected the ends of the samples for later gripping in tensile tests. The fixture featured controlled exposure areas, and protected the ends of the samples for later gripping in tensile tests. The fixture containing the films was installed in a clean vacuum chamber where protons, electrons and solar ultraviolet (UV) radiation could simultaneously irradiate the specimens. Near realtime UV rates were used, whereas proton and electron rates were accelerated appreciably to simulate 5 years in orbit during a two month test. Periodically, the spectral reflectance of each film was measured in situ. After the end of the irradiation, final reflectance measurements were made in situ, and solar absorptance values were derived for each specimen. These samples were then measured in air for thermal emittance and for tensile strength. Most specimens withstood the irradiation intact, but with reduced reflectance (increased solar absorptance). Thermal emittance changed slightly in several materials, as did their tensile strength and elongation at break. Conclusions are drawn about the performance of the films. Simulated testing to an expected 5 year dose of electrons and protons consistent with those expected at L2 and 0.98 AU orbits and 100 equivalent solar hours exposure.

Russell, Dennis A.↗