Search NASA⌕ Search

SEARCH · Search NASA

Results for “Laser interferometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Application of optical fibers to wide-band differential interferometry

A broadband differential optical interferometer that uses an optical-fiber waveguide to transmit coherent light to a surface under inspection is discussed. Input laser light is coupled into two single-mode optical fibers in a stationary input optics enclosure. The fibers transmit the light to a small, remote detection head where it is used in a wide-band differential interferometer to detect continuous and pulsed surface-particle displacements. The effective separation between the input optics and the detection head allows simple surface scanning and probe alignment. Detection of simulated acoustic emission pulses by a prototype test unit is reported.

Garg, A. O.↗

Digital Averaging Phasemeter for Heterodyne Interferometry

A digital averaging phasemeter has been built for measuring the difference between the phases of the unknown and reference heterodyne signals in a heterodyne laser interferometer. This phasemeter performs well enough to enable interferometric measurements of distance with accuracy of the order of 100 pm and with the ability to track distance as it changes at a speed of as much as 50 cm/s. This phasemeter is unique in that it is a single, integral system capable of performing three major functions that, heretofore, have been performed by separate systems: (1) measurement of the fractional-cycle phase difference, (2) counting of multiple cycles of phase change, and (3) averaging of phase measurements over multiple cycles for improved resolution. This phasemeter also offers the advantage of making repeated measurements at a high rate: the phase is measured on every heterodyne cycle. Thus, for example, in measuring the relative phase of two signals having a heterodyne frequency of 10 kHz, the phasemeter would accumulate 10,000 measurements per second. At this high measurement rate, an accurate average phase determination can be made more quickly than is possible at a lower rate.

Johnson, Donald↗

Transonic rotor flow-measurement technique using holographic interferometry

Holographic interferometry is used to record interferograms of the flow near a hovering transonic rotor blade. A pulsed ruby laser recorded 40 interferograms with a 2 ft dia. view field near the model rotor blade tip operating at a tip Mach number of 0.90. The experimental procedure is presented and example interferograms recorded in the rotor's tip path plane. In addition, a method currently being pursued to obtain quantitative flow information using computer assisted tomography (CAT) with the holographic interferogram data, is outlined.

Kittleson, John K.↗

Future Evolution of NASA's SLR and VLBI Networks

Over the first half of this decade the NASA Space Geodesy Program is planning a major transformation of its existing (Satellite Laser Ranging) SLR network of stations and also further evolutionary changes to its network of (Very Long Base Interferometry) VLBI stations. These network changes will be made to meet the ever more demanding requirements of the earth and space science programs that these networks support while seeking through automation and electronic data communications to increase efficiency and decrease cost of operations and maintenance. The major aspects of the NASA plan will be outlined and the benefits to the scientific community will be addressed.

Bosworth, John M.↗

LISA Optics Model

The Laser Interferometer Space Antenna (LISA) experiment has six telescopes, in three spacecraft, in orbit about the sun. There is a continuous two-way laser link between all of the spacecraft. The ability to make sub picometer level performance predictions about the interferometry for such a large optical system which has major subassemblies separated by 5 million kilometer distances which are constantly moving with respect to each other requires a slight extension of existing optical analysis techniques. To see this a description of the approach used to model all of the optics, in the spacecraft in orbit, is presented and the ability of this model to analyze requirements is discussed.

Waluschka, Eugene↗

Photon-Counting Interferometry to Detect Geontropic Space-Time Fluctuations with GQuEST

The gravity from the quantum entanglement of space-time (GQuEST) experiment uses tabletop-scale Michelson laser interferometers to probe for fluctuations in space-time. We present a practicable interferometer design featuring a novel photon-counting readout method that provides unprecedented sensitivity, as it is not subject to the interferometric standard quantum limit. We evaluate the potential of this design to measure space-time fluctuations motivated by recent “geontropic” quantum gravity models. The accelerated accrual of Fisher information offered by the photon-counting readout enables GQuEST to detect the predicted quantum gravity phenomena within measurement times at least 100 times shorter than equivalent conventional interferometers. The GQuEST design, thus, enables a fast and sensitive search for signatures of quantum gravity in a laboratory-scale experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vibration measurement by pulse differential holographic interferometry

Technique measures structural deformation of materials subjected to wide range of temperatures and other environmental conditions. Effects of convection currents are eliminated by operating a pulsed laser in double pulse mode that exposes hologram twice in quick succession.

Evensen, D. A.↗

Multi-axis Heterodyne Interferometry at MHz Frequencies: a Short-Arm Measurement Demonstration for LISA with Off-The-Shelf Hardware

We report the design, construction, and operation of a multi-axis heterodyne interferometry (MAHI) system operating at MHz heterodyne frequencies, which provides a testbed for technologies to be used in the Laser Interferometer Space Antenna (LISA) space-based gravitational wave mission. The system was calibrated for measurement of the piston, pitch, and yaw of a three-axis piezo-actuated mirror, giving measured calibration values that closely match those predicted by a simulation based on Gaussian beam tracing. The piston sensitivity of the MAHI system in the LISA band was measured to be below 10pmHz 1/2 10pmHz1/2 for frequencies above 4 mHz and below 1pmHz 1/2 1pmHz1/2 for frequencies above 35 mHz. The sensitivity is limited above 2 Hz by the mechanical vibrations of the apparatus and below 1 mHz by dimensional changes caused by temperature fluctuations. Evidence points towards scattered light as the limiting noise source at intermediate frequencies. The angular sensitivity of the MAHI system was measured to be close to or below 10nradHz 1/2 10nradHz1/2 for frequencies above 4 mHz and below 1nradHz 1/2 1nradHz1/2 for frequencies above 100 mHz. Noise budgets for both length and angle were determined, indicating the areas in which improvements must be made in order to reach increased sensitivity. The current operating sensitivity already provides a useful testbed for LISA technologies and a potential blueprint for future ground segment equipment.

Fulda, P.↗

Microscale Thermophoresis (MST) as a Tool to Study Binding Interactions of Oxygen-Sensitive Biohybrids

Microscale thermophoresis (MST) is a technique used to measure the strength of molecular interactions. MST is a thermophoretic-based technique that monitors the change in fluorescence associated with the movement of fluorescent-labeled molecules in response to a temperature gradient triggered by an IR LASER. MST has advantages over other approaches for examining molecular interactions, such as isothermal titration calorimetry, nuclear magnetic resonance, biolayer interferometry, and surface plasmon resonance, requiring a small sample size that does not need to be immobilized and a high-sensitivity fluorescence detection. In addition, since the approach involves the loading of samples into capillaries that can be easily sealed, it can be adapted to analyze oxygen-sensitive samples. In this Bio-protocol, we describe the troubleshooting and optimization we have done to enable the use of MST to examine protein–protein interactions, protein–ligand interactions, and protein–nanocrystal interactions. The salient elements in the developed procedures include 1) loading and sealing capabilities in an anaerobic chamber for analysis using a NanoTemper MST located on the benchtop in air, 2) identification of the optimal reducing agents compatible with data acquisition with effective protection against trace oxygen, and 3) the optimization of data acquisition and analysis procedures. The procedures lay the groundwork to define the determinants of molecular interactions in these technically demanding systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A holographic interferometry technique for measuring transonic flow near a rotor blade

A technique that uses holographic interferometry to record the first interferograms of the flow near a hovering transonic rotor blade is presented. A pulsed ruby laser is used to record interferograms of a 2 ft diam field of view near a rotor tip operating at a tip Mach number of 0.90. Several interferograms, recorded along planes perpendicular to the rotor's tip path plane at various azimuth angles around the flow, are presented. These interferograms yield quantitative information about shock structure and location, flow separation, and radiated noise that will help helicopter researchers understand the complexities of the flow around high speed rotor blades and thus improve performance and reduce noise.

Kittleson, J. K.↗

Fourier-transform optical microsystems

The design, fabrication, and initial characterization of a miniature single-pass Fourier-transform spectrometer (FTS) that has an optical bench that measures 1 cm x 5 cm x 10 cm is presented. The FTS is predicated on the classic Michelson interferometer design with a moving mirror. Precision translation of the mirror is accomplished by microfabrication of dovetailed bearing surfaces along single-crystal planes in silicon. Although it is miniaturized, the FTS maintains a relatively high spectral resolution, 0.1 cm-1, with adequate optical throughput.

NASA Discipline Environmental Health↗

SIM vs. SOS: A Space Interferometry Trade Study

This study was undertaken at the Jet Propulsion Laboratory to identify salient features of two competing instrument designs and to select the design that best meets the goals of the Space Interferometry Mission.

trade-study↗

XFEL imaging techniques for high energy density and inertial fusion energy research at HED-HiBEF

The imaging platform developed at the High Energy Density-Helmholtz International Beamline for Extreme Fields (HED-HiBEF) instrument at the European X-ray Free Electron Laser (XFEL) and its applications to HED and fusion related research are presented. The platform combines the XFEL beam with the high-intensity short-pulse laser ReLaX and the high-energy nanosecond-pulse laser DiPOLE-100X. The spatial resolution is better than 500 nm and the temporal resolution of the order of 50 fs. The influence of the XFEL source in the x-ray imaging method is discussed. Free-propagation x-ray phase contrast imaging and Talbot-Lau imaging setups are shown. We show examples of blast waves and converging cylindrical shocks in aluminum, resonant absorption measurements of specific charged states in copper with ReLaX and planar shocks in polystyrene material generated by DiPOLE-100X. For the first time, we show the application of Talbot-Lau interferometry to convergent cylindrical shocks as well as resonant absorption processes. We also discuss the possibilities introduced by combining this imaging platform with a kJ-class laser.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Beauty and Limitations of 10 Micron Heterodyne Interferometry (ISI)

Until recently, heterodyne interferometry at 10 microns has been the only successful technique for stellar interferometry in the very difficult atmospheric window from 9-12 microns. For most of its operational lifetime the U.C. Berkeley Infrared Spatial Interferometer was a single-baseline two telescope (1.65 m aperture) system using CO2 lasers as local oscillators. This instrument was designed and constructed from 1983-1988, and first fringes were obtained at Mt. Wilson in June 1988. During the past few years, a third telescope was constructed and just recently the first closure phases were obtained at 11.15 microns. We discuss the history, physics and technology of heterodyne interferometry in the mid-infrared, and some key astronomical results that have come from this unique instrument.

Danchi, William C.↗