Search NASA⌕ Search

SEARCH · Search NASA

Results for “Liquid helium”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Balloon-based measurements of the cosmic background radiation

A balloon-borne liquid-helium-cooled spectrometer was developed and flown to measure the cosmic background radiation in the 3- to 18-per-cm region. It features a cooled horn antenna, a polarizing Michelson interferometer, and a germanium bolometer. These design features and the performance of the instrument are discussed.

Mather, J. C.↗

Performance characteristics of the U.VA. superconducting wind tunnel balance

Initial operational characteristics of a wind tunnel electromagnetic balance utilizing superconducting coils are reported. Both dc and ac superconducting coils are used for balancing and measuring 3-component aerodynamic forces on simple models in Mach 3, room temperature flow. Liquid helium boil-off measurements corresponding to a wide range of operating conditions are presented together with results of systematic ac losses scaling experiments using various pancake coils wound with superconducting tape. This unique prototype facility is primarily for studying the practical feasibility of using superconducting magnetic suspension techniques for aerodynamic testing and accumulating the knowledge and expertise required for extrapolating these techniques to large-scale facilities.

Humphris, R. R.↗

Measurement of the spectrum of the submillimeter cosmic background

The spectrum of the night sky has been measured in the wave number range from 3 to 40 per cm using a fully calibrated liquid-helium-cooled balloon-borne spectrophotometer at an elevation of 39 km. A model based on the known molecular parameters was used to subtract the atmospheric emission. In the range from 4 to 17 per cm, the spectrum of the background radiation is that of a blackbody with a temperature of about 2.99 K.

Woody, D. P.↗

Far Infrared Spectroscopy of H II Regions

The far infrared spectra of H II regions are investigated. A liquid helium cooled grating spectrometer designed to make observations from the NASA Lear Jet is described along with tests of the instrument. The observing procedure on the Lear Jet telescope is described and the method of data analysis is discussed. Results are presented from a search for the (O III) 88.16 micron line. An upper limit on the emission in this line is obtained and line detection is described. Results are compared to theoretical predictions, and future applications of fine structure line observations are discussed. Coarse resolution results are given along with calibration problems. The spectra obtained are compared to models for dust emission.

Ward, D. B.↗

Quantum principles and free particles

The quantum principles that establish the energy levels and degeneracies needed to evaluate the partition functions are explored. The uncertainty principle is associated with the dual wave-particle nature of the model used to describe quantized gas particles. The Schroedinger wave equation is presented as a generalization of Maxwell's wave equation; the former applies to all particles while the Maxwell equation applies to the special case of photon particles. The size of the quantum cell in phase space and the representation of momentum as a space derivative operator follow from the uncertainty principle. A consequence of this is that steady-state problems that are space-time dependent for the classical model become only space dependent for the quantum model and are often easier to solve. The partition function is derived for quantized free particles and, at normal conditions, the result is the same as that given by the classical phase integral. The quantum corrections that occur at very low temperatures or high densities are derived. These corrections for the Einstein-Bose gas qualitatively describe the condensation effects that occur in liquid helium, but are unimportant for most practical purposes otherwise. However, the corrections for the Fermi-Dirac gas are important because they quantitatively describe the behavior of high-density conduction electron gases in metals and explain the zero point energy and low specific heat exhibited in this case.

Source record↗

Dewar technology study

The development of a Dewar system for handling liquid helium under weightless conditions is described. Porous plug designs for the prevention of superfluid creep out of the dewar through the vent line were evaluated. For the purpose of designing a neck to provide a transition from the cold cavity to the outside, the loads carried by the neck and equipment supports were studied. Temperature, pressure, and mass flow instrumentation for monitoring Dewar performance were also evaluated. In addition, multilayer blankets consisting of aluminized Mylar separated by Dacron net sheets were designed to insulate the pressure vessel. The dewar system is suggested for use with the star tracking telescope aboard the relativity satellite.

Davis, W.↗

Far-infrared photometry of NGC 1068

The detection of far-IR emission from the galaxy NGC 1068 in four passbands spanning the spectral range from 28 to 320 microns is reported. The observations were made with a 61-cm airborne IR telescope and a liquid-helium-cooled multifilter radiometer. It is found that the flux density between 38 and 100 microns increases with increasing wavelength to a maximum value of 454 (plus or minus 94) Jy, but decreases rapidly for wavelengths greater than 100 microns. The total flux is estimated to be about 3 by 10 to the -11th power W/sq m, which corresponds to a bolometric luminosity of 3.7 by 10 to 11th power times the solar luminosity at a distance of 20 Mpc. The nuclear M/L ratio is shown to be no greater than about 0.003, indicating that the scale, optical depth, or both, of a thermal far-IR source in NGC 1068 would have to be larger than those of the extended IR sources around the nuclei of our Galaxy, NGC 253, or M82.

Telesco, C. M.↗

16-25 micron spectroscopy of the Trapezium and BN-KL source in Orion

Spectrophotometric observations from 16 to 25 microns of the Trapezium and the Becklin-Neugebauer-Kleinmann-Low (BN-KL) object in Orion are reported. These observations were obtained with a liquid-helium-cooled grating spectrometer. The observations of the Trapezium show a relatively flat spectrum between 16 and 25 microns, which is consistent with a 20-micron emission peak similar to that previously found at 10 microns. The BN-KL source has a smooth spectrum over the same range, showing little absorption such as characterizes the 10-micron spectrum of this source. This lack of a deep 20-micron absorption is attributed to complex radiative-transfer processes within the molecular cloud.

Forrest, W. J.↗

Germanium-overcoated niobium Dayem bridges

Overcoating constriction microbridges with semiconducting germanium provides additional thermal conductivity at liquid-helium temperatures to reduce the effects of self-heating in these Josephson junctions. Microwave-induced steps were observed in the I-V characteristics of an overcoated Dayem bridge fabricated in a 15-nm-thick niobium film; at least 20 steps could be counted at 4.2 K. No steps were observed in the I-V characteristics of the bridge prior to overcoating. In addition, the germanium overcoat can protect against electrical disturbances at room temperature.

Holdeman, L. B.↗

Mass spectrometer beam system for applications in the stratosphere

A special gas inlet system is required for reduction of high ambient pressures to ion source operating pressures for mass spectrometer investigations in the stratosphere for the determination of the abundance of minor constituents. A system has been designed which combines a mass spectrometer and a gas inlet system reducing pressure by differential pumping using high-speed liquid helium pumps and small orifices. The gas particles are formed into a neutral beam with a flag mechanism proceeding into the mass spectrometer ion source where they are ionized for subsequent mass separation. A laboratory model has been tested under conditions simulating stratospheric pressures. It was shown that the process is able to identify gases with abundances below 10 to the -8th. Some of the problems associated with gas analysis of trace constituents have been alleviated, and other applications of the system have been identified, such as pollution control and medicine.

Mauersberger, K.↗

A Multi-Band Far-Infrared Survey with a Balloon-Borne Telescope

Nine additional radiation sources, above a 3-sigma confidence level of 1300 Jy, were identified at 100 microns by far infrared photometry of the galactic plane using a 0.4 meter aperture, liquid helium cooled, multichannel far infrared balloon-borne telescope. The instrument is described, including its electronics, pointing and suspension systems, and ground support equipment. Testing procedures and flight staging are discussed along with the reduction and analysis of the data acquired. The history of infrared astronomy is reviewed. General infrared techniques and the concerns of balloon astronomers are explored.

Jacobson, M. R.↗

Atomic hydrogen storage method and apparatus

Atomic hydrogen, for use as a fuel or as an explosive, is stored in the presence of a strong magnetic field in exfoliated layered compounds such as molybdenum disulfide or an elemental layer material such as graphite. The compound is maintained at liquid helium temperatures and the atomic hydrogen is collected on the surfaces of the layered compound which are exposed during delamination (exfoliation). The strong magnetic field and the low temperature combine to prevent the atoms of hydrogen from recombining to form molecules.

Woollam, J. A.↗

Balloon-borne photoionization mass spectrometer for measurement of stratospheric gases

A balloon-borne photoionization mass spectrometer used to measure stratospheric trace gases is described. Ions are created with photons from high-intensity krypton discharge lamps and a quadrupole mass analyzer is employed for ion identification. Differential pumping is achieved with liquid helium cryopumping. To insure measurement of unperturbed stratospheric air, the entire system is contained in a sealed gondola and the atmospheric sample is taken some distance away during descent. The photoionization technique allows the detection of a low ionization potential constituent, such as nitric oxide, at less than a part in one billion in the presence of the major atmospheric gases and their isotopes. Operation of the mass spectrometer system was demonstrated during a daytime flight from Palestine, Texas on 26 April 1977. The sensitivity achieved and the unique selectivity afforded by this technique offer a capability for trace constituent measurement not possible with the more conventional electron impact ionization approach.

Aikin, A. C.↗

Preliminary results from the University of Denver infrared spectrometer - 1977 intertropical convergence zone experiment

The Denver University Infrared Spectrometer (DUIRS) is a liquid-helium-cooled emission radiometer designed to study minor atmospheric constituents. DUIRS flew on 12 data flights during the 1977 Intertropical Convergence Zone experiment. No data were obtained on the flight from Wallops Island to Panama because of a power failure or on the return flight to Wallops Island because of a cryogen line freeze-up. The data coverage on the nine vertical profile flights that were flown before the freeze-up are shown. Typical spectra and variations as a function of U-2 (research aircraft) altitude are also shown. Radio metric data and rawinsonde temperature data were used to perform band model calculations to obtain molecular number densities in the column above the aircraft at each altitude.

Barker, D. B.↗

Low background focal plane array testing in the far infrared

A new long-wavelength infrared test facility is being developed to conduct proof-of-performance tests of focal plane arrays for the Infrared Astronomical Satellite (IRAS) telescope. This facility is believed to be unique in that it will calibrate full-sized arrays designed for the 5-120-micron region of the IR spectrum under simulated spaceflight conditions and at background levels as low as 8 million photons/sq cm-sec. Most of the tests will be performed in a main test chamber which contains a liquid helium shroud, blackbody sources, an arrangement to simulate zodiacal background, and spot scanning optics. A noncontaminating high-vacuum pumping system will be used to evacuate the chamber prior to cool-down to prevent molecular deposition. All housekeeping and focal plane signal outputs are multiplexed, digitized, and transmitted on high-speed data lines to a PDP-11/70 computer. The computer provides real-time displays on a color CRT terminal and stores data for subsequent reduction and hard copy output. An overview of the conceptual design and performance specifications of the test facility are given.

Iufer, E. J.↗

Mission design for the infrared astronomical satellite /IRAS/

IRAS, a joint United States, Netherlands, United Kingdom astronomical satellite, is scheduled to be launched early in 1981 with the purpose of completing an all-sky survey in the infrared wavelengths from 8 to 120 microns and to observe objects of special interest. The mission design is driven by thermal constraints primarily determined by the Sun and Earth; the orbit and survey strategy must be chosen so as to satisfy the mission requirements before the cryogenic system is depleted of its liquid helium. Computer graphics help the designer choose valid survey strategies and evaluate resulting sky coverage.

Lundy, S. A.↗

Spectrum of the cosmic background radiation

Measurements of the emission spectrum of the night sky have been made in the frequency range from 1.7 to 40 kaysers by using a fully calibrated liquid-helium-cooled balloon-borne spectrophotometer. The results show that the spectrum of the cosmic background radiation peaks at 6 kaysers and is approximately that of a 3-K blackbody out to several times that frequency. However, the data show deviations from a simple blackbody curve.

Woody, D. P.↗

Four-color infrared bolometer system for one-meter telescope

A far-infrared photometer has been developed as a focal plane instrument for a balloon-borne 102-cm telescope. The four gallium-doped Ge bolometers adopted for the system operate at 1.8 K in a liquid-helium dewar. Wavelength bands of the four-bolometer system are a narrow spectrum between 18 and 22 microns, and bands centered at 42, 70, and 140 microns. The responsivity and Johnson noise of the detectors limit the performance of the instrument.

Daneu, V.↗