Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mechanical instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

A next generation ultra short pulse reflectometry (USPR) diagnostic

Ultrashort Pulse Reflectometry (USPR) is a plasma diagnostic technique involving the propagation and reflection of ultrashort duration (~few ns) chirps. The reflected packets pass through a multichannel filter with time-of-flight measurements performed on each of the filtered packets. A next generation USPR system is under development, spanning 28–75 GHz, for use on compact, short duration, magnetically confined fusion devices. This system presents a dramatic increase in performance compared with an earlier USPR system employed on the LLNL Sustained Spheromak Physics Experiment device more than a decade ago. The new system replaces upconverting mixers with higher power active multiplier chains to generate mm-wave transmitter chirps, with custom time-of-flight electronics reducing the time per measurement by a factor of 3X. Finally, the system is equipped with a field programmable gate array for data acquisition and analysis.

47 OTHER INSTRUMENTATION↗

Scanning SQUID microscopy in a cryogen-free dilution refrigerator

We report a scanning superconducting quantum interference device (SQUID) microscope in a cryogen-free dilution refrigerator with a base temperature at the sample stage of at least 30 mK. The microscope is rigidly mounted to the mixing chamber plate to optimize thermal anchoring of the sample. The microscope housing fits into the bore of a superconducting vector magnet, and our design accommodates a large number of wires connecting the sample and sensor. Through a combination of vibration isolation in the cryostat and a rigid microscope housing, we achieve relative vibrations between the SQUID and the sample that allow us to image with micrometer resolution over a 150 μm range while the sample stage temperature remains at base temperature. To demonstrate the capabilities of our system, we show images acquired simultaneously of the static magnetic field, magnetic susceptibility, and magnetic fields produced by a current above a superconducting micrometer-scale device.

47 OTHER INSTRUMENTATION↗

High resolution atomic force microscopy with an active piezoelectric microcantilever

Active microcantilevers with on-chip sensing and actuation provide significant advantages in tapping mode Atomic Force Microscopy (AFM). Collocated transduction allows for effective manipulation of cantilever dynamics through feedback control, enabling higher scan rates. However, the adjacency of the sensing and actuation electrodes is known to result in a high level of feedthrough, leading to a low imaging resolution. Readout circuit noise further deteriorates the imaging precision. Here, we investigate the noise sources that affect AFM microcantilevers with collocated aluminum nitride (AlN) actuator–sensor pairs. We reported these cantilevers in earlier work and demonstrated that they display a very low level of feedthrough between the actuation and sensing electrodes. We present a high signal-to-noise ratio (SNR) sensing method that enables us to demonstrate high-resolution AFM on a calibration grating with nm-step silicon carbide (SiC) terraces. In conclusion, measuring the Lorentzian response of the cantilever’s Brownian motion with the on-chip active sensor at resonance enables us to calibrate the dynamic stiffness at the first fundamental resonance mode, without utilizing an optical sensor.

47 OTHER INSTRUMENTATION↗

Support of Integrated Health Management (IHM) through Automated Analyses of Flowfield-Derived Spectrographic Data

Flow-field analysis techniques under continuing development at NASA's Marshall Space Flight Center are the foundation for a new type of health monitoring instrumentation for propulsion systems and a vast range of other applications. Physics, spectroscopy, mechanics, optics, and cutting-edge computer sciences merge to make recent developments in such instrumentation possible. Issues encountered in adaptation of such a system to future space vehicles, or retrofit in existing hardware, are central to the work. This paper is an overview of the collaborative efforts results, current efforts, and future plans.

Patrick, Marshall C.↗

Cryogenic Optical Position Encoders for Mechanisms in the JWST Optical Telescope Element Simulator (OSIM)

The JWST Optical Telescope Element Simulator (OSIM) is a configurable, cryogenic, optical stimulus for high fidelity ground characterization and calibration of JWST's flight instruments. OSIM and its associated Beam Image Analyzer (BIA) contain several ultra-precise, cryogenic mechanisms that enable OSIM to project point sources into the instruments according to the same optical prescription as the flight telescope images stars - correct in focal surface position and chief ray angle. OSIM's and BIA's fifteen axes of mechanisms navigate according to redundant, cryogenic, absolute, optical encoders - 32 in all operating at or below 100 K. OSIM's encoder subsystem, the engineering challenges met in its development, and the encoders' sub-micron and sub-arcsecond performance are discussed.

Leviton, Douglas B.↗

Tandem pyrolysis evolved gas–gas chromatography–mass spectrometry

Analysis of byproducts from thermal degradation of polymer materials provides a wealth of information about a materials’ composition, thermal stability, degradation mechanisms, and kinetics. However, regardless of the instrumentation used, only limited information is obtainable from a single experiment. Microfurnace technology, when interfaced to a gas chromatography-mass spectrometry (GC-MS), can be used to obtain both thermal and chemical information via evolved gas analysis-MS (EGA-MS) and GC-MS analysis modes. While both EGA-MS and Py-GC-MS are valuable when characterizing polymer materials, at least two experiments on distinct samples are required, which can be a liability for clear interpretation of results from inhomogeneous samples. Here, we seek to overcome this limitation by combining EGA-MS and Py-GC-MS modes in a single experimental setup. Further, this was done by developing new gas line modifications to allow for tandem Pyrolysis Evolved Gas-Gas Chromatography-Mass Spectrometry (Py/EG-GC-MS) analysis. Verification of Py/EG-GC-MS analysis was performed using a polystyrene standard. Results demonstrate successful Py/EG-GC-MS analysis for the first-time showing the potential of these modifications for application in areas where sample is limited or direct correlation of products to the thermal profile is desirable such as in forensics or product-specific kinetics.

36 MATERIALS SCIENCE↗

Cortical Proteins and Individual Differences in Cognitive Resilience in Older Adults

Background and objectives: Cognitive resilience is a well-recognized concept, but knowledge gaps about its underlying mechanisms have made it difficult to develop instruments that identify older adults with high or low resilience. We tested whether aggregating cortical peptides associated with cognitive resilience into an index can identify adults with higher or lower cognitive resilience. Methods: We used data from 1,192 older decedents, including annual clinical testing, indices of 10 Alzheimer disease (AD) and related dementia (ADRD) pathologies, and 226 proteotypic peptides measured in the dorsal lateral prefrontal cortex. We used linear mixed-effects models to identify peptides that were related to cognitive resilience (i.e., cognitive decline not explained by ADRD pathologies [false discovery rate <0.05]). We aggregated the expression levels of these resilience peptides into a person-specific cognitive resilience index and examined its association with AD clinical and pathologic phenotypes. Results: We constructed a resilience index from 52 of 226 peptides related to cognitive resilience. A higher index was associated with slower cognitive decline (estimate 0.05, SE 0.003, p < 0.001) and slower motor decline (estimate 0.005, SE 0.001, p < 0.001). Most resilience peptides (70%) were specific to cognitive decline, but 30% also provided resilience for motor decline. A higher index was also related to a lower burden of AD pathologies (odds ratio [OR] 0.41, SE 0.01, p < 0.001) and modified the association of AD pathology with cognition in that a higher index modified the negative effects of AD pathology on AD dementia proximate to death (OR 0.70, SE 0.14, p = 0.010). Up to 90% of cognitive resilience peptides were related to AD pathologic phenotypes. Discussion: Cortical proteins may provide some degree of cognitive resilience. These multifunctional proteins also seem to provide resilience to other AD clinical phenotypes and have independent associations with ADRD pathologies. Resilience proteins may be high-value therapeutic targets for drug discovery of interventions that maintain brain health in aging adults via multiple pathways.

60 APPLIED LIFE SCIENCES↗

Surveyor 3 Preliminary Science Results

Surveyor III soft-landed on the Moon at 00:04 GMT on April 20, 1967. Data obtained have significantly increased our knowledge of the Moon. The Surveyor III spacecraft was similar to Surveyor I; the only major change in scientific instrumentation was the addition of a soil mechanics surface sampler. Surveyor III results at this preliminary evaluation of data give valuable information about the relation between the surface skin of under-dense material responsible for the photometric properties and the deeper layers of material whose properties resemble those of ordinary terrestrial soils. In addition, they provide new insight into the relation between the general lunar surface as seen by Surveyor I and the interior of a large subdued crater. The new results have also contributed to our understanding of the mechanism of downhill transport. Many critical questions cannot, however, be answered until final reduction of experimental data.

Source record↗

Microelectronics bioinstrumentation systems

Microelectronic bioinstrumentation systems to be employed in the Cardiovascular Deconditioning Program were developed. Implantable telemetry systems for long-term monitoring of animals on earth were designed to collect physiological data necessary for the understanding of the mechanisms of cardiovascular deconditioning. In-flight instrumentation systems, microelectronic instruments, and RF powering techniques for other life science experiments in the NASA program were studied.

Ko, W. H.↗

Bent glass optics

The paper describes how a glass strip may be bent to match any curve of large radius of curvature, to a high degree of accuracy, so that it may be used as a glancing incidence X-ray or extreme ultraviolet optical element. The desired match is obtained by applying a suitable combination of end couples and adjusting the cross-sectional moment of inertia along the length of the strip by varying its breadth. Two applications are described; a parabolic reflector for use as a laboratory X-ray collimator for testing mechanical collimators to be used in space instruments, and an elliptical reflector for point-to-point focussing. The latter device has been used for testing gratings in the X-ray and extreme ultraviolet (EUV) regions and for concentrating radiation on the entrance slit of a spectrometer, with a resultant gain in speed and resolution. It is suggested that the technique may have other laboratory and space applications, which are briefly described.

Underwood, J. H.↗

An extensometer for axial strain measurement at high temperature

Most existing strain measuring instruments, important for the investigation of the mechanical behavior of metals at high temperature, have temperature, strain range, and size limitations. In this short note the authors give the design and construction of an extensometer with sufficient dynamic range and good stability over long periods of time, for measuring the longitudinal strain of plane specimens from 0.001 to 0.1 at temperatures up to 800 C.

Schmidt, J.↗

High Resolution Imager (HRI) for the Roentgen Satellite (ROSAT) definition study

The design of the high resolution imager (HRI) on HEAO 2 was modified for use in the instrument complement of the Roentgen Satellite (ROSAT). Mechanical models of the front end assembly, central electronics assembly, and detector assembly were used to accurately represent the HRI envelope for both fit checks and focal plane configuration studies. The mechanical and electrical interfaces were defined and the requirements for electrical ground support equipment were established. A summary description of the ROSAT telescope and mission is included.

Source record↗

Thin metal film and multilayers experiment (A0138-3)

The sources of degradation of in state of the art and newly developed components and testing the usefulness of the concept of storing experiment samples in dry nitrogen under launch and space vacuum conditions during reentry mission phase were investigated. Ultraviolet (UV) and extreme ultraviolet (EUV) experiments suffer degradations during space missions of even 1 month duration. It is suggested that the degradation is due to condensation of outgassing products, followed by solar induced polymerization, however, penetrating charged particles are also known to produce volume effects. Degradation may also start immediately after manufacturing of the component due to oxidation, moisture, or chemical corrosion by atmospheric constituents such as CO2 and SO2. When the filters are used as windows for gas absorption cells or gas filters, or when they define the instrumental bandwidth by themselves. The effects of mechanical degradation by thermal cycling and/or dust may cause a dramatic impact.

Delaboudiniere, J. P.↗

Michelson interferometer with separated inputs and outputs, double pass, and compensation

A novel configuration is proposed for a Michelson interferometer spectrometer, which will be insensitive to tilts or displacements, and which employs separated inputs and outputs and double passing for higher resolution. The great advantage of such a compensated design is a relaxation of mechanical tolerances, which is especially beneficial for instruments in hostile environments. The Atmospheric Trace Molecule Spectroscopy project, which must work reliably after being subjected to the vibrations of a Space Shuttle launch, would benefit from the use of such an instrument.

Mather, J. C.↗

Turbomachinery technology for high-speed civil flight

NASA Lewis' research and technology efforts applicable to turbomachinery for high-speed flight are discussed. The potential benefits and cycle requirements for advanced variable cycle engines and the supersonic throughflow fan engine for a high-speed civil transport application are presented. The supersonic throughflow fan technology program is discussed. Technology efforts in the basic discipline areas addressing the severe operating conditions associated with high-speed flight turbomachinery are reviewed. Included are examples of work in internal fluid mechanics, high-temperature materials, structural analysis, instrumentation and controls.

Saunders, Neal T.↗

Modeling of internal contaminant deposition on a cold instrument sensor

A model is developed to predict the deposition of contaminants on the CCD sensors of the Wide Field Planetary Camera to determine expected performance parameters. Contaminant deposition due to internal instrument sources is considered as is the mechanism of transport to the CCDs themselves. The Contamination Analysis Program (CAP) model considers deposition and reemission kinetics, nodal containment sources, and internodal shape factors related to line-of-sight transport. Indirect transport is also accounted for in the CAP model by considering the effect of diffuse reflection at internodal exchanges. The effective total transport factors for each node-to-node exchange is precalculated to reduce the effective number of nodes and reducing run time of the CAP program. The method is applied to four distinct conditions and is found to be suitable for the analysis of internal self-contamination. Cold traps, venting, and vacuumlike design are factors which are found to be important for cold-sensitive sensors.

Barengoltz, Jack B.↗

Design of a fast computer-based partial discharge diagnostic system

Partial discharges cause progressive deterioration of insulating materials working in high voltage conditions and may lead ultimately to insulator failure. Experimental findings indicate that deterioration increases with the number of discharges and is consequently proportional to the magnitude and frequency of the applied voltage. In order to obtain a better understanding of the mechanisms of deterioration produced by partial discharges, instrumentation capable of individual pulse resolution is required. A new computer-based partial discharge detection system was designed and constructed to conduct long duration tests on sample capacitors. This system is capable of recording large number of pulses without dead time and producing valuable information related to amplitude, polarity, and charge content of the discharges. The operation of the system is automatic and no human supervision is required during the testing stage. Ceramic capacitors were tested at high voltage in long duration tests. The obtained results indicated that the charge content of partial discharges shift towards high levels of charge as the level of deterioration in the capacitor increases.

Oliva, Jose R.↗

A three dimensional radiative transfer method for optical remote sensing of vegetated land surfaces

In the application of remote sensing at optical wavelengths to vegetated surfaces from satellite borne high resolution instruments, an understanding of the various physical mechanisms that contribute to the measured signal is important. A numerical method of solving the radiative transfer equation in three dimensions is reported. The reliability of coding and accuracy of the algorithm are evaluated by benchmarching. Parametrization of the methods and results of a simulation are presented. The method is tested with experimental data of canopy bidirectional reflectance factors. The effect of spatial heterogeneity on the relationship between the simple ratio and normalized vrs absorbed Photosynthetically Active Radiation (PAR) is discussed.

Asrar, Ghassem↗