Search NASA⌕ Search

SEARCH · Search NASA

Results for “Precision optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Cold Gas and Star Formation in the Phoenix Cluster with JWST

We present integral field unit observations of the Phoenix Cluster with the JWST Mid-infrared Instrument’s Medium Resolution Spectrometer. We focus this study on the molecular gas, dust, and star formation in the brightest cluster galaxy (BCG). We use precise spectral modeling to produce maps of the silicate dust, molecular gas, and polycyclic aromatic hydrocarbons (PAHs) in the inner ∼50 kpc of the cluster. We measure the optical depth from silicates by comparing the observed H 2 line ratios to those predicted by excitation models. We provide updated measurements of the total molecular gas mass of $1.9^{+0.5}_{-0.04}$ x 10 10 M ⊙ , which agrees with CO-based estimates, providing an estimate of the CO-to-H 2 conversion factor of α CO = 0.8 ± 0.2 M ⊙ pc -2 (K km s -1 ) -1 ; an updated stellar mass of M * = 2.6 ± 0.5 × 10 10 M ⊙ ; and star formation rates (SFRs) averaged over 10 and 100 Myr of $\langle$SFR$\rangle$ 10 = 1340 ± 100 M ⊙ yr −1 and $\langle$SFR$\rangle$ 100 = 740 ± 80 M ⊙ yr −1 , respectively. The H 2 emission seems to be powered predominantly by shocks and star formation within the central ∼20 kpc, induced by stellar feedback and radio jets from the active galactic nucleus. Additionally, we find nearly an order-of-magnitude drop in the SFRs estimated by PAH fluxes in cool core BCGs compared to field galaxies, suggesting that hot particles from the intracluster medium are destroying PAH grains even in the central-most tens of kiloparsecs.

Active galaxies↗

A modular apparatus for use in high-precision measurements of parity violation in polarized eV neutron transmission

We describe a modular apparatus for use in parity-violation measurements in epithermal neutron–nucleus resonances with high instantaneous neutron fluxes at the Manuel Lujan Jr. Neutron Scattering Center at Los Alamos National Laboratory. This apparatus is designed to conduct high-precision measurements of the parity-odd transmission asymmetry of longitudinally polarized neutrons through targets containing nuclei with p-wave neutron–nucleus resonances in the 0.1–10 eV energy regime and to accommodate a future search for time reversal violation in polarized neutron transmission through polarized nuclear targets. The apparatus consists of an adjustable neutron and gamma collimation system, a 3 He- 4 He ion chamber neutron flux monitor, two identical cryostats for target cooling, an adiabatic eV-neutron spin flipper, a near-unit efficiency 6 Li- 7 Li scintillation detector operated in current mode, a flexible CAEN data acquisition system, and a neutron spin filter based on spin-exchange optical pumping of 3 He gas. We describe the features of the apparatus design devoted to the suppression of systematic errors in parity-odd asymmetry measurements. We describe the configuration of the apparatus used to conduct a precision measurement of parity violation at the 0.7 eV p-wave resonance in 139 La which employs two identical 139 La targets, one to polarize the beam on the p-wave resonance using the weak interaction and one to analyze the polarization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Eos: conceptual design for a demonstrator of hybrid optical detector technology

Eos is a technology demonstrator, designed to explore the capabilities of hybrid event detection technology, leveraging both Cherenkov and scintillation light simultaneously. With a fiducial mass of four tons, Eos is designed to operate in a high-precision regime, with sufficient size to utilize time-of-flight information for full event reconstruction, flexibility to demonstrate a range of cutting edge technologies, and simplicity of design to facilitate potential future deployment at alternative sites. Results from Eos can inform the design of future neutrino detectors for both fundamental physics and nonproliferation applications. This paper describes the conceptual design and potential applications of the Eos

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision Loading and Delivery of Molecular Cargo by Size-Controlled Coacervation of Gold Nanoparticles Functionalized with Elastin-like Peptides

Thermoresponsive elastin-like peptides (ELPs) have been extensively investigated in biotechnology and medicine, but little attention has been paid to the process by which coacervation causes ELP-decorated particles to aggregate. Here, using gold nanoparticles (AuNPs) functionalized with a cysteine-terminated 96-repeat of the VPGVG sequence (V96-Cys), we show that the size of the clusters that reversibly form above the ELP transition temperature can be finely controlled in the 250 to 930 nm range by specifying the concentration of free V96-Cys in solution and using AuNPs of different sizes. We further find that the localized surface plasmon resonance peak of the embedded AuNPs progressively red-shifts with cluster size, likely due to an increase in particle–particle contacts. We exploit this fine control over size to homogeneously load precise amounts of the dye Nile Red and the antibiotic Tetracycline into clusters of different hydrodynamic diameters and deliver cargos near-quantitatively by deconstructing the aggregates below the ELP transition temperature. Beyond establishing a key role for free ELPs in the agglomeration of ELP-functionalized particles, our results provide a path for the thermally controlled delivery of precise quantities of molecular cargo. This capability might prove useful in combination photothermal therapies and theranostic applications, and to trigger spatially and temporally uniform responses from biological, electronic, or optical systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microwave-Absorbing Foams with Adjustable Absorption Frequency and Structural Coloration

Microwave-absorbing materials with regulatable absorption frequency and optical camouflage hold great significance in intelligent electronic devices and advanced stealth technology. Herein, we present an innovative microwave-absorbing foam that can dynamically tune microwave absorption frequencies via a simple mechanical compression while in parallel enabling optical camouflage over broad spectral ranges by adjusting the structural colors. In this study, the vivid colors spanning different color categories generated from thin-film interference can be precisely regulated by adjusting the thickness of the conformal TiO 2 coatings on Ni/melamine foam. Enhanced interfacial and defect-induced polarizations resulting from the introduction of TiO 2 coating synergistically contribute to the dielectric attenuation performance. Consequently, such a foam exhibits exceptional microwave absorption capabilities, and the absorption frequency can be dynamically tuned from the S band to the Ku band by manipulating its compression ratio. Additionally, simulation calculations validate the adjustable electromagnetic wave loss behavior, offering valuable insights for the development of next-generation intelligent electromagnetic devices across diverse fields.

36 MATERIALS SCIENCE↗

A Visual Understanding of Circular Dichroism Spectroscopy

Mapping chemical and structural properties to electronic and magnetic responses is critical to many applications such as quantum information science, where the precise storage and transmission of unique information is paramount. Specifically, constructing molecules and materials that provide strong polarized responses at tunable frequencies and with large anisotropies is key to optical processing of quantum information. Chiral molecules provide chiroptical response to circularly polarized light, making them attractive for quantum information science and other applications related to sensing, polarized photodetectors, and spintronics. Predicting a molecular design, a priori, with large anisotropies to circularly polarized light is challenging due to the complex interplay between electric and magnetic components of the optical response. In this work, we explore a visual representation of the electronic chiroptical response by decomposing the rotary strength into its constituent components. Here, we make use of the intuitive electronic oscillator framework to develop classical intuition regarding the rotary strength and its constituents. We explore three model chemical systems that exhibit local and global chirality. Our analysis reveals that local chirality necessarily exhibits competition between the local chiral center and chirality induced in other fragments of the molecule, resulting in both unexpected nonmonotonic trends and sign flips in chemically adjacent geometries. Furthermore, we can visually distinguish between local and global chirality via examination of the transition chiral tensor. Interestingly, we make strong connections to ferromagnetic and antiferromagnetic spin systems in that chiroptically inactive transitions exhibit antiferromagnetic-like alternating orbital patterns while active transitions show domain formation in an ferromagnetic-like alignment that produces a net chiroptical response.

36 MATERIALS SCIENCE↗

Laser cutting apparatus for high energy density and diamond anvil cell science

In this paper, we present a low-cost, high-resolution laser cutting system designed for use in the fabrication of samples for high energy density physics. Such samples are necessarily small but require precision and repeatability, particularly with the recently available high repetition rates possible at modern facilities. The system allows simultaneous laser cutting, using nanosecond near-infrared laser pulses, and optical microscopy so that the cut can be monitored in real time. The capabilities of the system are demonstrated on a range of materials for both laser-matter interaction targets and components for high pressure diamond anvil cell experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimized manufacturing process for multilayer two-dimensional focusing mirrors in laboratory X-ray applications

Recent advances in laboratory X-ray applications require high-performance optical components that achieve exceptional imaging resolution and beam uniformity within compact experimental setups. Montel mirrors have become a preferred solution due to their unique dual-reflection focusing mechanism and a space-efficient design. Here, in this study, we present an effective manufacturing process for producing Montel mirrors tailored to focus laboratory X-ray beams. The mirrors were fabricated from single-crystal silicon substrates, chosen for their high mechanical stability and compatibility with precision polishing techniques. Our approach begins with the integration of a deterministic chemo-mechanical polishing (CMP)-based pre-shaping step followed by ion beam figuring (IBF), significantly improving manufacturing efficiency. Subsequently, our custom-developed advanced metrology and IBF techniques were employed for fabricating an off-axis, elliptical cylinder Montel mirror system with a 6-mrad total slope, with stringent optical specifications. While post-IBF processes, including multilayer coating, dicing, and gluing, introduced minor surface errors, yet their impact on performance remained negligible. The Montel mirrors manufactured with the optimized process exhibited significantly improved beam uniformity and a reduced focal spot size. These findings validate our approach as a viable solution for high-precision Montel mirror fabrication and facilitate further advancements in laboratory X-ray applications.

36 MATERIALS SCIENCE↗

Detecting keyhole porosity and monitoring process signatures in additive manufacturing: an in situ pyrometry and ex situ X-ray radiography correlation

Creation of pores and defects during laser powder bed fusion (LPBF) can lead to poor mechanical properties and thus must be minimized. Post-build inspection is required to ensure the printed parts contain acceptably low defect concentrations. These inspections are time consuming and costly, especially for large or complex parts. As a potential solution, in situ process monitoring can be used to detect the creation of defects, characterize local material behavior and predict expected component properties. However, the precise relationship between pore creation and in situ process monitoring still needs to be understood. In this work, high-speed infrared diode-based pyrometry and high-speed optical imaging signals were used to monitor LPBF printing of 446 stainless steel 316 L single tracks with varying laser power and velocity. Results indicate an increase in pyrometer signal and melt pool dimensions with increasing laser power and decreasing velocity in agreement with previous work. In addition, careful analysis of pyrometer signal reveals a distinct signature of the conduction-to-keyhole mode transition which was confirmed by metallography. Critically, pore defect initiation as characterized by ex situ X-ray radiography was correlated with in situ thermal monitoring signals to derive the probability of defect creation. Our results show that, in principle, a probabilistic prediction of pore formation can be achieved based on in situ high-speed pyrometry monitoring of the LPBF melt pool.

36 MATERIALS SCIENCE↗

Two Spacers, One Perovskite: Integrating Ruddlesden–Popper and Dion–Jacobson Halide Perovskites

Hybrid organic–inorganic perovskites are a rapidly developing class of materials due to their desirable properties for optoelectronic applications such as their ease of synthesis, solution-processable film formation, tunable band gap, strong photoluminescence, good charge carrier mobilities, and high defect tolerance. Here, we present a novel 2D perovskite motif that seamlessly integrates the structural elements from both Ruddlesden–Popper and Dion–Jacobson halide perovskites. We demonstrate the incorporation of two different organic spacer cations in an ordered manner in 5 novel 2D perovskite iodide materials. Both a cyclic diammonium cation 3-(aminomethyl)piperidinium (3AMP) and a linear alkyl monoammonium cation (Cn = C n H 2n+4 N, n = 4–8) are present in distinct alternating layers, making the new series (Cn) 2 (3AMP)[PbI 4 ] 2 . The crystallization of these materials was optimized through careful temperature control to obtain precise crystal structures via single-crystal X-ray diffraction (XRD) which confirmed the presence of the two cations in distinct layers. The influence of the two spacers on optical properties including the band gaps and photoluminescence spectra are found to more closely resemble (3AMP)PbI 4 than (Cn) 2 PbI 4 , which can be attributed to the amount of distortion imposed by the 3AMP spacer on the lead iodide layers. The findings are supported by density functional theory calculations. The strong photoelectric response of solution-processed thin films shows the potential of these materials in photodetectors or photovoltaics. This unprecedented amalgamation of RP–DJ in (Cn) 2 (3AMP)[PbI 4 ] 2 in a structurally ordered fashion suggests a potential vastly underexplored phase space of 2D perovskites in which there are chemically different spacers in distinct layers of the structure, providing an additional parameter to tune perovskite properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Uranium Single Particle Analysis for Simultaneous Fluorine and Uranium Isotopic Determinations via Laser-Induced Breakdown Spectroscopy/Laser Ablation–Multicollector–Inductively Coupled Plasma–Mass Spectrometry

Uranyl fluoride (UO 2 F 2 ) particles (<20 μm) were subjected to first-of-its-kind analysis via simultaneous laser-induced breakdown spectroscopy (LIBS) and laser ablation multi-collector inductively coupled plasma–mass spectrometry (LA–MC–ICP–MS). Briefly, a nanosecond pulsed high-energy laser was focused onto the sample (particle) surface. In a single laser pulse, the UO 2 F 2 particle was excited/ionized within the microplasma volume, and the emission of light was collected via fiber optics such that emission spectroscopy could be employed for the detection of uranium (U) and fluorine (F). The ablated particle was simultaneously transported into the MC–ICP–MS for high precision isotopic (i.e., 234 U, 235 U, and 238 U) analysis. This method, LIBS/LA–MC–ICP–MS was optimized and employed to rapidly measure 80+ UO 2 F 2 particles, which were subjected to different calcination processes, which results in varying degrees of F loss from the individual particles. In measuring the particles, the average F/U ratios for the populations treated at 100 and 500 °C were 2.78 ± 1.28 and 1.01 ± 0.50, respectively, confirming loss of F through the calcination process. The average 235 U/ 238 U on the particle populations for the 100 and 500 °C were 0.007262 (22) and 0.007231 (23), which was determined to be <0.2% from the expected value. The 234 U/ 238 U ratios on the same particles were 0.000053 (11) and 0.000050 (10) for the 100 and 500 °C, respectively, <10% from the expected value. Notably, each population was analyzed in under 5 min, demonstrating the truly rapid analysis technique presented here in this paper.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Assessment of errors in analytic modeling of permanent magnet electron spectrometers for laser-plasma accelerators

Here, we assess the error in three treatments of a critical electron beam diagnostic for laser-plasma acceleration (LPA) experiments: a permanent magnet electron spectrometer. Since LPA electron spectrometers are often difficult to calibrate due to the scarcity of well-characterized, tunable electron beam sources in the appropriate energy range and the mechanical complexity of electron spectrometers, the standard of calibration is Hall probe measurements. We first compare the electron spectrometer performance between SIMION calculations and the Hall probe measurements. We find up to a 60% (<8%) error in determining the absolute energy for electrons below (above) 80 MeV when using the SIMION-modeled magnetic field vs the measured magnetic field due to SIMION overpredicting fringe field strength. The difference in spectrometer energy resolution is within ∼10% between the modeled and measured fields. We then assess a simple block model, which is commonly used. We find that the simple block model presented here sufficiently captures the predicted as-built spectrometer performance for any application provided that the user can tolerate uncertainties on absolute energy determination up to 5% and errors on energy resolution up to 1%.

Electromagnetic optics↗

Strongly Coupled Plasmon and Phonon Polaritons as Seen by Photon and Electron Probes

The ability to control and modify infrared excitations in condensed matter is of both fundamental and applied interest. Here we explore a system supporting low-energy excitations, in particular, mid-infrared localized plasmon modes and phonon polaritons that are tuned to be strongly coupled. We study the coupled modes by using far-field infrared spectroscopy, state-of-the-art monochromated electron energy-loss spectroscopy, numerical simulations, and analytical modeling. Here we demonstrate that the electron probe facilitates a precise characterization of polaritons constituting the coupled system, and enables an active control over the coupling and the resulting sample response both in frequency and space. Although far-field optical spectra can be substantially different from near-field electron energy-loss spectra, we show that a direct comparison is possible via postprocessing and right positioning of the electron beam. The resulting spectra allow us to evaluate the key parameters of the coupled system, such as the coupling strength, which we demonstrate to be probe independent. Our work establishes a rigorous description of the spectral features observed in light- and localized electron-based spectroscopies, which can be extended to the analysis of analogous optical systems with applications in heat management and electromagnetic field concentration or nanofocusing.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sensitivity of ultralight axion dark matter search with optical quantum sensors

An optical quantum sensor (OQS) based on lasers and alkali-metal atoms is a sensitive ambient-temperature magnetometer that can be used in axion dark matter search with an inductor-capacitor (LC) circuit at kHz and MHz frequencies. We have previously investigated the sensitivity of an LC circuit-OQS axion detector to ultralight axion dark matter that could be achieved using a fT-noise OQS constructed in our lab. In this paper, we investigate the sensitivity that could be potentially reached by an OQS performing close to the fundamental quantum noise levels of 10 aT / $\sqrt{Hz}$. To take advantage of the quantum-limited OQS, the LC circuit has to be made of a superconductor and cooled to low temperature of a few K. After considering the intrinsic noise of the advanced axion detector and characterizing possible background noises, we estimate that such an experiment could probe benchmark QCD axion models in an unexplored mass range near 10 neV. Reaching such a high sensitivity is a difficult task, so we have conducted some preliminary experiments with a large-bore magnet and a prototype axion detector consisting of a room-temperature LC circuit and a commercial OQS unit. In conclusion, this paper describes the prototype experiment and its projected sensitivity to axions in detail.

79 ASTRONOMY AND ASTROPHYSICS↗

Does the Sun have a dark disk?

The Sun is not quite a perfect sphere, and its oblateness, thought to be induced through its rotation, has been measured using optical observations of its radius. Its gravitational quadrupole moment can then be deduced using solar models, or through helioseismology, and it can also be determined from measurements of its gravitational effects on Mercury’s orbit. The various assessments do not appear to agree, with the most complete and precise orbital assessments being in slight excess of other determinations. This may speak to the existence of a nonluminous disk or ring, where we also note evidence for a circumsolar dust ring within Mercury’s orbit from the Solar TErrestrial RElations Observatory (STEREO) mission. Historically, too, a protoplanetary disk may have been key to reconciling the Sun’s metallicity with its neutrino yield. The distribution of the nonluminous mass within Mercury’s orbit can modify the relative size of the optical and orbital quadrupole moments in different ways. We develop how we can use these findings to limit the mass of a dark disk, ring, or halo in the immediate vicinity of the Sun, and we note how future observational studies of the inner Solar System can not only refine these constraints but can also help to identify and to assess the mass of its dark-matter component. Published by the American Physical Society 2025

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optical Design and Characterization of 40-GHz Detector and Module for the BICEP Array

Families of cosmic inflation models predict a primordial gravitational-wave background that imprints B-mode polarization pattern in the cosmic microwave background (CMB). High-sensitivity instruments with wide frequency coverage and well-controlled systematic errors are needed to constrain the faint B-mode amplitude. We have developed antenna-coupled transition edge sensor arrays for high-sensitivity polarized CMB observations over a wide range of millimeter-wave bands. BICEP array, the latest phase of the BICEP/Keck experiment series, is a multi-receiver experiment designed to search for inflationary B-mode polarization to a precision σ(r) between 0.002 and 0.004 after 3 full years of observations, depending on foreground complexity and the degree of lensing removal. We describe the electromagnetic design and measured performance of BICEP array’s low-frequency 40-GHz detector, their packaging in focal plane modules, and optical characterization including efficiency and beam matching between polarization pairs. We summarize the design and simulated optical performance, including an approach to improve the optical efficiency due to mismatch losses. Here, we report the measured beam maps for a new broadband corrugation design to minimize beam differential ellipticity between polarization pairs caused by interactions with the module housing frame, which helps minimize polarized beam mismatch that converts CMB temperature to polarization (T→P) anisotropy in CMB maps.

47 OTHER INSTRUMENTATION↗

High-bandwidth CMOS-voltage-level electro-optic modulation of 780 nm light in thin-film lithium niobate

Integrated photonics operating at visible-near-infrared (VNIR) wavelengths offer scalable platforms for advancing optical systems for addressing atomic clocks, sensors, and quantum computers. The complexity of free-space control optics causes limited addressability of atoms and ions, and this remains an impediment on scalability and cost. Networks of Mach-Zehnder interferometers can overcome challenges in addressing atoms by providing high-bandwidth electro-optic control of multiple output beams. Here, we demonstrate a VNIR Mach-Zehnder interferometer on lithium niobate on sapphire with a CMOS voltage-level compatible full-swing voltage of 4.2 V and an electro-optic bandwidth of 2.7 GHz occupying only 0.35 mm 2 . Our waveguides exhibit 1.6 dB/cm propagation loss and our microring resonators have intrinsic quality factors of 4.4 × 10 5 . This specialized platform for VNIR integrated photonics can open new avenues for addressing large arrays of qubits with high precision and negligible cross-talk.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Reverse Polarizability of Rare Earth Ions (La 3+ , Gd 3+ , Lu 3+ , Y 3+ ) in Tellurite Glasses and Glass Ceramics for Optical Limiting

All-optical modulation using inherent third-order optical nonlinearity of a medium has garnered considerable interest in photonics and optoelectronics. Herein, nonlinear optical (NLO) properties of tellurite glasses and glass ceramics (GCs) containing four different rare earths (RE = La, Gd, Lu, and Y) have been deliberated in near-infrared regions under an ultrafast regime. The La-based glass exhibits ~10 times higher nonlinear refraction (n 2 ) and absorption (α 2 ) than reported NLO materials. The NLO susceptibility [χ (3) ] trend in the studied glasses is La > Gd > Lu > Y, matching with RE 3+ polarizability. Furthermore, Ln 2 Te 6 O 15 nanocrystallite-embedded transparent GCs exhibit a larger NLO coefficient due to the enhanced local field from oxygen vacancies in crystallites. Interestingly, the trend of χ (3) in GCs follows the sequence of Y > Lu > Gd > La, precisely opposite to the glasses. This observation challenges the general polarizability approach of RE 3+ ions, emphasizing that quadratic hyperpolarizability of RE 3+ is pivotal for NLO properties of GCs. Among the studied matrices, Y-containing GCs showed the lowest optical limiting (OL) threshold (5.4 mJ/cm 2 at 800 nm), much lower than those of the reported NLO materials, suggesting its potential as a femtosecond NIR-laser safety material. A combination of large α 2 and n 2 from the studied matrices indicates their advantage for harmonic generation, potentially aiding in the design of ultrafast signal processing devices.

36 MATERIALS SCIENCE↗