Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scanning techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Surface Diagnostics in Tribology Technology and Advanced Coatings Development

This paper discusses the methodologies used for surface property measurement of thin films and coatings, lubricants, and materials in the field of tribology. Surface diagnostic techniques include scanning electron microscopy, transmission electron microscopy, atomic force microscopy, stylus profilometry, x-ray diffraction, electron diffraction, Raman spectroscopy, Rutherford backscattering, elastic recoil spectroscopy, and tribology examination. Each diagnostic technique provides specific measurement results in its own unique way. In due course it should be possible to coordinate the different pieces of information provided by these diagnostic techniques into a coherent self-consistent description of the surface properties. Examples are given on the nature and character of thin diamond films.

Miyoshi, Kazuhisa↗

Atomic structure of different surface terminations of polycrystalline ZnPd

The intermetallic compound ZnPd has been found to have desirable characteristics as a catalyst for the steam reforming of methanol. The understanding of the surface structure of ZnPd is important to optimize its catalytic behavior. However, due to the lack of bulk single-crystal samples and the complexity of characterizing surface properties in the available polycrystalline samples using common experimental techniques, all previous surface science studies of this compound have been performed on surface alloy samples formed through thin-film deposition. In this study, we present findings on the chemical and atomic structure of the surfaces of bulk polycrystalline ZnPd studied by a variety of complementary experimental techniques, including scanning tunneling microscopy (STM), x-ray photoelectron spectroscopy (XPS), low energy electron microscopy (LEEM), photoemission electron microscopy (PEEM), and microspot low-energy electron diffraction ( μ -LEED). These experimental techniques, combined with density functional theory (DFT)-based thermodynamic calculations of surface free energy and detachment kinetics at the step edges, confirm that surfaces terminated by atomic layers composed of both Zn and Pd atoms are more stable than those terminated by only Zn or Pd layers. DFT calculations also demonstrate that the primary contribution to the tunneling current arises from Pd atoms, in agreement with the STM results. The formation of intermetallics at surfaces may contribute to the superior catalyst properties of ZnPd over Zn or Pd elemental counterparts. Published by the American Physical Society 2024

36 MATERIALS SCIENCE↗

Extending radiative transfer models by use of Bayes rule

This paper presents a procedure that extends some existing radiative transfer modeling techniques to problems in atmospheric science where curvature and layering of the medium and dynamic range and angular resolution of the signal are important. Example problems include twilight and limb scan simulations. Techniques that are extended include successive orders of scattering, matrix operator, doubling, Gauss-Seidel iteration, discrete ordinates and spherical harmonics. The procedure for extending them is based on Bayes' rule from probability theory.

Whitney, C.↗

Feasibility of inertialess conscan utilizing modified DSN feedsystems

The closed-loop conical-scan (conscan) technique has proven to be a useful method for pointing the DSN antennas more accurately than is possible by open-loop methods. As presently implemented, the antenna beam is scanned about the received signal direction by physical movement of the antenna. While straightforward, this approach has at least two disadvantages. Firstly, because of structural distortions, finite angle encoder resolution, and drive servo response, the actual antenna beam direction only approximates the commanded beam direction. Secondly, because of the large mass moved during scan, the rate of scan is severely restricted. If there are significant gain or signal level variations during a scan period, the conscan system interprets these variations as antenna pointing error. Both of these disadvantages would be alleviated in an inertialess conscan system in which the beam scanning was performed electronically. Recently, standard JPL antenna feedhorn software was upgraded to calculate, among other things, asymmetric corrugated horn radiation patterns of the type that would be needed for electronic beam scan. The required horn excitation is discussed and the results were described.

Potter, P. D.↗

NASA Glenn/AADC-Rolls Royce Collaborated to Measure Erosion Resistance on Coated Polymer Matrix Composites

Polymer matrix composites (PMCs) are increasingly used in aerospace and automotive applications because of their light weight and high strength-to-weight ratio relative to metals. However, a major drawback of PMCs is poor abrasion resistance, which restricts their use, especially at high temperatures. Simply applying a hard coating on PMCs to improve abrasion and erosion resistance is not effective since coating durability is short lived (ref. 1). Generally, PMCs have higher coefficients of thermal expansion than metallic or ceramic coatings have, and coating adhesion suffers because of poor interfacial adhesion strength. One technique commonly used to improve coating adhesion or durability is the use of bond coats that are interleaved between a coating and a substrate with vastly different coefficients of thermal expansion. An example of this remedy is the use of bondcoats for ceramic thermal barrier coatings on metallic turbine components (ref. 2). Prior collaborative research between the NASA Glenn Research Center and the Allison Advanced Development Company (AADC) demonstrated that bond coats sandwiched between PMCs and high-quality plasma-sprayed, erosion-resistant coatings substantially improved the erosion resistance of PMCs (ref. 3). One unresolved problem in this earlier collaboration was that there was no easy, accurate way to measure the coating erosion wear scar. Coating wear was determined by both profilometry and optical microscopy. Both techniques are time consuming. Wear measurement by optical microscopy requires sample destruction and does not provide a comprehensive measure of the entire wear volume. An even more subtle, yet critical, problem is that these erosion coatings contain two or more materials with different densities. Therefore, simply measuring specimen mass loss before and after erosion will not provide an accurate gauge for coating and/or substrate volume loss. By using a noncontact technique called scanning optical interferometry, which was recently developed at Glenn, researchers can accurately determine the wear performance of erosion-coated PMCs while preserving the sample. An example of this interferometry technique is shown in the preceding figure for an erosion-coated inlet guide vane from a Rolls Royce AE3007 regional gas turbine jet engine. Erosion was conducted with coated and uncoated PMC vanes, with the abrasive material moving at a velocity of 229 m/s at impingement angles of 20 and 90 degrees. The coatings for PMCs remarkably reduced the erosion volume loss by a factor of approximately 10. Currently, several erosion coatings for PMCs are being compared and downselected for engine testing at Rolls Royce.

Miyoshi, Kazuhisa↗

Localization of a Portion of an Endorectal Balloon for Prostate Image-Guided Radiation Therapy Using Cone-Beam Tomosynthesis: A Feasibility Study

Purpose: To assess the feasibility of using cone-beam tomosynthesis (CBTS) to localize the air-tissue interface for the application of prostate image-guided radiation therapy using an endorectal balloon for immobilization and localization. Methods and Materials: A Feldkamp-David-Kress-based CBTS reconstruction was applied to selected sets of cone-beam computed tomography (CBCT) projection data to simulate volumetric imaging achievable from tomosynthesis for a limited range of scan angles. Projection data were calculated from planning CT images of 10 prostate cancer patients treated with an endorectal balloon, as were experimental CBCT projections for a pelvic phantom in two patients. More than 50 points at the air-tissue interface were objectively identified by an intensity-based interface-finding algorithm. Using three-dimensional point sets extracted from CBTS images compared with points extracted from corresponding CBCT images, the relative shift resulting from a reduced scan angle was determined. Because the CBCT and CBTS images were generated from the same projection data set, shift identified was presumed to be due to distortions introduced by the tomosynthesis technique. Results: Scans of {>=}60 Degree-Sign were shown to be able to localize an air-tissue interface near the isocenter with accuracy on the order of a millimeter. The accuracy was quantified in terms of the mean discrepancy as a function of reconstruction angle. Conclusion: This work provides an understanding of the effect of scan angle used in localization of a portion of an endorectal balloon by means of CBTS. CBTS with relatively small scan angles is capable of accurately localizing an extended interface near the isocenter and may provide clinically relevant measurements to guide IGRT treatments while reducing imaging radiation to the patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Seeing is believing: visualization of antiferromagnetic domains

Abstract Understanding and utilizing novel antiferromagnetic (AFM) materials has been recently one of the central issues in condensed matter physics, as well as in materials science and engineering. The relevant contemporary topics include multiferroicity, topological magnetism and AFM spintronics. The ability to image magnetic domains in AFM materials is of key importance for the success of these exciting fields. While imaging techniques of magnetic domains on the surfaces of ferro-(ferri)magnetic materials with, for example, magneto-optical Kerr microscopy and magnetic force microscopy have been available for a number of decades, AFM domain imaging is a relatively new development. We review various experimental techniques utilizing scanning, optical, and synchrotron X-ray probes to visualize AFM domains and domain walls, and to unveil their physical properties. We also discuss the existing challenges and opportunities in these techniques, especially with further increase of spatial and temporal resolution.

36 MATERIALS SCIENCE↗

Scanning electrochemical probe microscopy investigation of two-dimensional materials

Research interests in two-dimensional (2D) materials have seen exponential growth owing to their unique and fascinating properties. The highly exposed lattice planes coupled with tunable electronic states of 2D materials have created manifold opportunities in the design of new platforms for energy conversion and sensing applications. Still, challenges in understanding the electrochemical (EC) characteristics of these materials arise from the complexity of both intrinsic and extrinsic heterogeneities that can obscure structure–activity correlations. Scanning EC probe microscopic investigations offer unique benefits in disclosing local EC reactivities at the nanoscale level that are otherwise inaccessible with macroscale methods. This review summarizes recent progress in applying techniques of scanning EC microscopy (SECM) and scanning EC cell microscopy (SECCM) to obtain distinctive insights into the fundamentals of 2D electrodes. We showcase the capabilities of EC microscopies in addressing the roles of defects, thickness, environments, strain, phase, stacking, and many other aspects in the heterogeneous electron transfer, ion transport, electrocatalysis, and photoelectrochemistry of representative 2D materials and their derivatives. Perspectives for the advantages, challenges, and future opportunities of scanning EC probe microscopy investigation of 2D structures are discussed.

36 MATERIALS SCIENCE↗

More than 10 years experience of beam monitoring with the Gantry 1 spot scanning proton therapy facility at PSI

Purpose: The beam monitoring equipments developed for the first PSI spot scanning proton therapy facility, Gantry 1, have been successfully used for more than 10 years. The purpose of this article is to summarize the author's experience in the beam monitoring technique for dynamic proton scanning. Methods: The spot dose delivery and verification use two independent beam monitoring and computer systems. In this article, the detector construction, electronic system, dosimetry, and quality assurance results are described in detail. The beam flux monitor is calibrated with a Faraday cup. The beam position monitoring is realized by measuring the magnetic fields of deflection magnets with Hall probes before applying the spot and by checking the beam position and width with an ionization strip chamber after the spot delivery. Results: The results of thimble ionization chamber dosimetry measurements are reproducible (with a mean deviation of less than 1% and a standard deviation of 1%). The resolution in the beam position measurement is of the order of a tenth of a millimeter. The tolerance of the beam position delivery and monitoring during scanning is less than 1.5 mm. Conclusions: The experiences gained with the successful operation of Gantry 1 represent a unique and solid background for the development of a new system, Gantry 2, in order to perform new advanced scanning techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multigrid Optimization for Large-Scale Ptychographic Phase Retrieval

Ptychography is a popular imaging technique that combines diffractive imaging with scanning microscopy. The technique consists of a coherent beam that is scanned across an object in a series of overlapping positions, leading to reliable and improved reconstructions. Ptychographic microscopes allow for large fields to be imaged at high resolution at the cost of additional computational expense. Herein, we propose a multigrid-based optimization framework to reduce the computational burdens of large-scale ptychographic phase retrieval. Our proposed method exploits the inherent hierarchical structures in ptychography through tailored restriction and prolongation operators for the object and data domains. Our numerical results show that our proposed scheme accelerates the convergence of its underlying solver and outperforms the ptychographical iterative engine, a workhorse in the optics community.

97 MATHEMATICS AND COMPUTING↗

TH-CD-209-10: Scanning Proton Arc Therapy (SPArc) - The First Robust and Delivery-Efficient Spot Scanning Proton Arc Therapy

Purpose: To develop a delivery-efficient proton spot-scanning arc therapy technique with robust plan quality. Methods: We developed a Scanning Proton Arc(SPArc) optimization algorithm integrated with (1)Control point re-sampling by splitting control point into adjacent sub-control points; (2)Energy layer re-distribution by assigning the original energy layers to the new sub-control points; (3)Energy layer filtration by deleting low MU weighting energy layers; (4)Energy layer re-sampling by sampling additional layers to ensure the optimal solution. A bilateral head and neck oropharynx case and a non-mobile lung target case were tested. Plan quality and total estimated delivery time were compared to original robust optimized multi-field step-and-shoot arc plan without SPArc optimization (Arcmulti-field) and standard robust optimized Intensity Modulated Proton Therapy(IMPT) plans. Dose-Volume-Histograms (DVH) of target and Organ-at-Risks (OARs) were analyzed along with all worst case scenarios. Total delivery time was calculated based on the assumption of a 360 degree gantry room with 1 RPM rotation speed, 2ms spot switching time, beam current 1nA, minimum spot weighting 0.01 MU, energy-layer-switching-time (ELST) from 0.5 to 4s. Results: Compared to IMPT, SPArc delivered less integral dose(−14% lung and −8% oropharynx). For lung case, SPArc reduced 60% of skin max dose, 35% of rib max dose and 15% of lung mean dose. Conformity Index is improved from 7.6(IMPT) to 4.0(SPArc). Compared to Arcmulti-field, SPArc reduced number of energy layers by 61%(276 layers in lung) and 80%(1008 layers in oropharynx) while kept the same robust plan quality. With ELST from 0.5s to 4s, it reduced 55%–60% of Arcmulti-field delivery time for the lung case and 56%–67% for the oropharynx case. Conclusion: SPArc is the first robust and delivery-efficient proton spot-scanning arc therapy technique which could be implemented in routine clinic. For modern proton machine with ELST close to 0.5s, SPArc would be a popular treatment option for both single and multi-room center.

60 APPLIED LIFE SCIENCES↗

Minimum Detectable Activity for Tomographic Gamma Scanning System

For any radiation measurement system, it is useful to explore and establish the detection limits and a minimum detectable activity (MDA) for the radionuclides of interest, even if the system is to be used at far higher values. The MDA serves as an important figure of merit, and often a system is optimized and configured so that it can meet the MDA requirements of a measurement campaign. The non-destructive assay (NDA) systems based on gamma ray analysis are no exception and well established conventions, such the Currie method, exist for estimating the detection limits and the MDA. However, the Tomographic Gamma Scanning (TGS) technique poses some challenges for the estimation of detection limits and MDAs. The TGS combines high resolution gamma ray spectrometry (HRGS) with low spatial resolution image reconstruction techniques. In non-imaging gamma ray based NDA techniques measured counts in a full energy peak can be used to estimate the activity of a radionuclide, independently of other counting trials. However, in the case of the TGS each “view” is a full spectral grab (each a counting trial), and each scan consists of 150 spectral grabs in the transmission and emission scans per vertical layer of the item. The set of views in a complete scan are then used to solve for the radionuclide activities on a voxel by voxel basis, over 16 layers of a 10x10 voxel grid. Thus, the raw count data are not independent trials any more, but rather constitute input to a matrix solution for the emission image values at the various locations inside the item volume used in the reconstruction. So, the validity of the methods used to estimate MDA for an imaging technique such as TGS warrant a close scrutiny, because the pair-counting concept of Currie is not directly applicable. One can also raise questions as to whether the TGS, along with other image reconstruction techniques which heavily intertwine data, is a suitable method if one expects to measure samples whose activities are at or just above MDA levels. The paper examines methods used to estimate MDAs for a TGS system, and explores possible solutions that can be rigorously defended.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Minimum detectable activity for tomographic gamma scanning system - 15648

For any radiation measurement system, it is useful to explore and establish the detection limits and a minimum detectable activity (MDA) for the radionuclides of interest, even if the system is to be used at far higher values. The MDA serves as an important figure of merit, and often a system is optimized and configured so that it can meet the MDA requirements of a measurement campaign. The non-destructive assay (NDA) systems based on gamma ray analysis are no exception and well established conventions, such the Currie method, exist for estimating the detection limits and the MDA. However, the Tomographic Gamma Scanning (TGS) technique poses some challenges for the estimation of detection limits and MDAs. The TGS combines high resolution gamma ray spectrometry (HRGS) with low spatial resolution image reconstruction techniques. In non-imaging gamma ray based NDA techniques measured counts in a full energy peak can be used to estimate the activity of a radionuclide, independently of other counting trials. However, in the case of the TGS each 'view' is a full spectral grab (each a counting trial), and each scan consists of 150 spectral grabs in the transmission and emission scans per vertical layer of the item. The set of views in a complete scan are then used to solve for the radionuclide activities on a voxel by voxel basis, over 16 layers of a 10x10 voxel grid. Thus, the raw count data are not independent trials any more, but rather constitute input to a matrix solution for the emission image values at the various locations inside the item volume used in the reconstruction. So, the validity of the methods used to estimate MDA for an imaging technique such as TGS warrant a close scrutiny, because the pair-counting concept of Currie is not directly applicable. One can also raise questions as to whether the TGS, along with other image reconstruction techniques which heavily intertwine data, is a suitable method if one expects to measure samples whose activities are at or just above MDA levels. The paper examines methods used to estimate MDAs for a TGS system, and explores possible solutions that can be rigorously defended. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Torsional force microscopy of van der Waals moirés and atomic lattices

In a stack of atomically thin van der Waals layers, introducing interlayer twist creates a moiré superlattice whose period is a function of twist angle. Changes in that twist angle of even hundredths of a degree can dramatically transform the system’s electronic properties. Setting a precise and uniform twist angle for a stack remains difficult; hence, determining that twist angle and mapping its spatial variation is very important. Techniques have emerged to do this by imaging the moiré, but most of these require sophisticated infrastructure, time-consuming sample preparation beyond stack synthesis, or both. In this work, we show that torsional force microscopy (TFM), a scanning probe technique sensitive to dynamic friction, can reveal surface and shallow subsurface structure of van der Waals stacks on multiple length scales: the moirés formed between bi-layers of graphene and between graphene and hexagonal boron nitride (hBN) and also the atomic crystal lattices of graphene and hBN. In TFM, torsional motion of an Atomic Force Microscope (AFM) cantilever is monitored as it is actively driven at a torsional resonance while a feedback loop maintains contact at a set force with the sample surface. TFM works at room temperature in air, with no need for an electrical bias between the tip and the sample, making it applicable to a wide array of samples. It should enable determination of precise structural information including twist angles and strain in moiré superlattices and crystallographic orientation of van der Waals flakes to support predictable moiré heterostructure fabrication.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-J-220: Micro-CT Based Quantification of Mouse Brain Vasculature: The Effects of Acquisition Technique and Contrast Material

Purpose: Cognitive impairment from radiation therapy to the brain may be linked to the loss of total blood volume in the brain. To account for brain injury, it is crucial to develop an understanding of blood volume loss as a result of radiation therapy. This study investigates µCT based quantification of mouse brain vasculature, focusing on the effect of acquisition technique and contrast material. Methods: Four mice were scanned on a µCT scanner (Siemens Inveon). The reconstructed voxel size was 18µm3 and all protocols were Hounsfield Unit (HU) calibrated. The mice were injected with 40mg of gold nanoparticles (MediLumine) or 100µl of Exitron 12000 (Miltenyi Biotec). Two acquisition techniques were also performed. A single kVp technique scanned the mouse once using an x-ray beam of 80kVp and segmentation was completed based on a threshold of HU values. The dual kVp technique scanned the mouse twice using 50kVp and 80kVp, this segmentation was based on the ratio of the HU value of the two kVps. After image reconstruction and segmentation, the brain blood volume was determined as a percentage of the total brain volume. Results: For the single kVp acquisition at 80kVp, the brain blood volume had an average of 3.5% for gold and 4.0% for Exitron 12000. Also at 80kVp, the contrast-noise ratio was significantly better for images acquired with the gold nanoparticles (2.0) than for those acquired with the Exitron 12000 (1.4). The dual kVp acquisition shows improved separation of skull from vasculature, but increased image noise. Conclusion: In summary, the effects of acquisition technique and contrast material for quantification of mouse brain vasculature showed that gold nanoparticles produced more consistent segmentation of brain vasculature than Exitron 12000. Also, dual kVp acquisition may improve the accuracy of brain vasculature quantification, although the effect of noise amplification warrants further study.

60 APPLIED LIFE SCIENCES↗

Combined microscopy studies of complex electronic materials. Final report

The aim of this project was to study the electronic properties of exotic electronic materials which are only available as micron-scale samples or have microscopic inhomogeneity, using a special combination of multiple submicron scanning microscopy techniques allied to control of temperature, magnetic and electric fields and mechanical strain. In nanobeams of VO 2 , with its still mysterious metal-insulator phase transition, we determined the phase diagram and demonstrated that hydrogen diffusion is strongly channelled along one crystal axis. Using graphene, we developed and applied the scanning photo-Nernst effect, in which a current is generated when a laser is focused on the edge a sample in a magnetic field. We demonstrated that CrI 3 , a two-dimensional layered magnet, retains true Ising ferromagnetization down the monolayer level due to its out-of-plane anisotropy. In exfoliated WTe 2 , a layered topological semimetal, we discovered that monolayers are the first monolayer topological insulator and we imaged the helical edge states with scanning microwave microscopy. We also discovered that the same material when stacked in a few layers is a ferroelectric metal, and that the monolayer can be converted to a superconducting state by electron doping with a gate a temperatures below 1 K. Additionally, we developed the capability to perform momentum-resolved electronic spectroscopy on operating nanoscale devices by applying micron-scale angle resolved photoemission spectroscopy to two-dimensional heterostructure devices incorporating graphene and transition metal dichalcogenide semiconductors. Using it, we measured the band gaps of a series of monolayer semiconductors and observed band renormalization as a function of electron doping in monolayer WSe 2 .

36 MATERIALS SCIENCE↗

Coupling Microstructural Evolution Simulations to Material Property Degradation Predictions for Plasma-Facing Materials

Reliable material performance is required for plasma-facing material (PFM) candidates. Previous research has shown that plasma and neutron radiation exposure induces microstructural changes in PFMs; changes in thermal and electrical conductivities and in material hardening and embrittlement were also observed after neutron irradiation. These material property changes will negatively impact the performance of the PFMs in a fusion reactor. Despite the well-known connection between material microstructure, properties, and performance, there is a need for validated modeling capabilities connecting PFM property degradation with microstructural evolution under fusion-relevant conditions. We are developing a simulation capability to couple plasma-induced microstructural evolution to material property degradation. Our approach relies on deliberate mapping between individual simulation models and experimental characterization for validation. The open-source Multiphysics Object-Oriented Simulation Environment (MOOSE) software was used for this simulation capability development. A MOOSE phase-field model was coupled with the cluster dynamics code, Xolotl, to predict microstructural evolution. Microstructure characterization techniques, including scanning electron microscopy (SEM), transmission electron microscopy (TEM), and laser scanning confocal microscopy (LSCM) are used to validate these microstructural evolution simulations. Calculation of thermal and electrical conductivities with first principles simulations was performed for bulk material and for grain boundaries; these results are used within MOOSE models to calculate effective thermal and electrical conductivities as a function of grain characteristics. Thermoreflectance and four-probe techniques were employed to measure the thermal and electrical conductivities, respectively. A MOOSE crystal plasticity model was adapted to predict microstructure-sensitive deformation behavior, and X-ray diffraction (XRD) was used to collect bulk dislocation density data for validation. After individual simulation validation, these models are coupled to predict material property changes resulting from plasma exposure. We focused here on an experimental design to emphasize the separate effects of moderate thermal loads and plasma exposure using tungsten. Annealing of tungsten was performed under a protective environment for temperatures ranging from 500 C to 1500 C. The plasma exposure was completed in the Tritium Plasma Experiment at Idaho National Laboratory under a deuterium flux of 1e22 D/m^2-s. This incremental approach is employed to build confidence in the modeling capability: separate-effects tests ensure that the models capture key mechanisms from single environmental conditions before predicting PFM property degradation under combined loads. We will show our early results from coupling these simulation models to predict PFM property changes from microstructural evolution. Comparisons of the simulation results with preliminary validation data will be discussed.

36 - MATERIALS SCIENCE↗

Connect microstructure evolution to property degradation with validated simulation

Reliable material performance is required for plasma-facing material (PFM) candidates. Previous research has shown that plasma and neutron radiation exposure induces microstructural changes in PFMs; changes in thermal and electrical conductivities and in material hardening and embrittlement were also observed after neutron irradiation. These material property changes will negatively impact the performance of the PFMs in a fusion reactor. Despite the well-known connection between material microstructure, properties, and performance, there is a need for validated modeling capabilities connecting PFM property degradation with microstructural evolution under fusion-relevant conditions. We are developing a simulation capability to couple plasma-induced microstructural evolution to material property degradation. Our approach relies on deliberate mapping between individual simulation models and experimental characterization for validation. The open-source Multiphysics Object-Oriented Simulation Environment (MOOSE) software was used for this simulation capability development. A MOOSE phase-field model was coupled with the cluster dynamics code, Xolotl, to predict microstructural evolution. Microstructure characterization techniques, including scanning electron microscopy (SEM), transmission electron microscopy (TEM), and laser scanning confocal microscopy (LSCM) are used to validate these microstructural evolution simulations. Calculation of thermal and electrical conductivities with first principles simulations was performed for bulk material and for grain boundaries; these results are used within MOOSE models to calculate effective thermal and electrical conductivities as a function of grain characteristics. Thermoreflectance and four-probe techniques were employed to measure the thermal and electrical conductivities, respectively. A MOOSE crystal plasticity model was adapted to predict microstructure-sensitive deformation behavior, and X-ray diffraction (XRD) was used to collect bulk dislocation density data for validation. After individual simulation validation, these models are coupled to predict material property changes resulting from plasma exposure. We focused here on an experimental design to emphasize the separate effects of moderate thermal loads and plasma exposure using tungsten. Annealing of tungsten was performed under a protective environment for temperatures ranging from 500$^o$C to 1500$^o$C. The plasma exposure was completed in the Tritium Plasma Experiment at Idaho National Laboratory under a deuterium flux of 1e22 $\frac{D}{m^2s}$. This incremental approach is employed to build confidence in the modeling capability: separate-effects tests ensure that the models capture key mechanisms from single environmental conditions before predicting PFM property degradation under combined loads. We will show our early results from coupling these simulation models to predict PFM property changes from microstructural evolution. Comparisons of the simulation results with preliminary validation data will be discussed.

36 - MATERIALS SCIENCE↗