Search NASA⌕ Search

SEARCH · Search NASA

Results for “Utility Regulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Peer-to-peer Communication Control Architecture for Engaging Ubiquitous DERs to Support Distribution System Resiliency

In this project, we developed a leader-follower consensus (LFC) control architecture to coordinate between GFM and GFL inverters with the former being leaders and the latter being followers. The objective is to simultaneously achieve a fast frequency and voltage regulation along with accurate real power and var sharing among all inverters under various disturbances. The distinction of our work is that we consider both GFM and GFL inveters for frequency and voltage regulations. In addition, rather than a standard consensus algorithm, our work utilized a leader-follower consensus algorithm which exploits the physical characteristics of GFM-GFL inverters: (i) the GFM inverters directly control frequency and voltage, and hence, serve as leaders, (ii) the GFL inverters measure frequency/voltage to modulate their outputs, and hence, they should serve as followers. The effectiveness of the proposed LFC coordination was tested on a networked microgrid test system under different disturbances and communication degradation events. We demonstrated that the proposed fully coordinated control is robust to disturbances, while outperforming uncoordinated and GFM-only coordinated approaches. Overall, this work emphasized the necessity and benefits of the GFMGFL coordination in the secondary control of microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

LINAC Longitudinal Simulation and Measurement of Output Energy

The Fermilab Linac, a pivotal and historic accelerator at Fermilab, is crucial to the laboratory's operations, supplying a 400 MeV beam to various acceleration facilities. Due to daily variations in the Linac's output energy, precise monitoring and machine tuning are important to ensure the exiting energy meets the Booster's acceptance criteria. To address this, Beam Position Monitors (BPMs) are employed to assess and adjust the beam's energy, providing essential data on both the transverse position and longitudinal phase of the beam. We also aim to regulate the longitudinal phase profile to match our simulation predictions. By utilizing a Python-based simulation and beam data from three BPMs, we can determine the optimal phasing correction required for the final RF stage to achieve the desired energy. Currently, the calculations of longitudinal phase profile are based on simulations, so additional research is needed to verify if the predicted longitudinal phase distribution aligns with actual real-world data.

Safaryan, Milena↗

Precursor Analysis Report: SQL Slammer Worm Infection of Davis-Besse Nuclear Power Plant 2003

The SQL Slammer Worm Infection of Davis-Besse Nuclear Power Plant 2003 Precursor Analysis Report leverages publicly available information about Davis-Besse’s 2003 cyber attack and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. On 25 January 2003, the SQL Slammer worm infected more than 90% of vulnerable hosts and crashed the internet in 10 to 15 minutes, making it one of the fastest spreading worms in history. SQL Slammer is a fileless, memory-resident worm that remotely exploits a stack-based buffer overflow vulnerability on local hosts to intensively scan and rapidly self-propagate across the internet. The worm infected approximately 300,000 unpatched hosts running Microsoft Structured Query Language (SQL) Server 2000 or Microsoft Desktop Engine (MSDE) 2000 with SQL Server Resolution Service. The SQL Slammer worm indirectly infected FirstEnergy’s Davis-Besse nuclear power plant by first infecting a consultant’s company network server and then propagating through an external misconfigured connection into Davis-Besse’s site network. The infection caused major network congestion, slow performance, data overloads, and the inability of local hosts to communicate with each other, which eventually caused a loss of availability and a loss of view when the Safety Parameter Display System (SPDS) and Plant Process Computer (PPC) crashed. At the time of the infection, the plant was already offline, the digital monitoring systems had redundant analog backups, and the plant control and safety functions were not affected, so there were no concerns of a safety breach. However, this incident resulted in many lessons learned and spawned important discussions about cybersecurity’s role in nuclear safety and electric power reliability regulation, policy, and guidance. Researchers and analysts identified 10 unique techniques utilized during the attack with a total of 640 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Eight of the identified techniques used during Davis-Besse cyber attack were precursors to the triggering event. Analysis identified 596 observables associated with these precursor techniques, 428 of which were assessed to have an increased likelihood of being perceived in the 331 days preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Power processor design considerations for a solar electric propulsion spacecraft

Propulsion power processor design options are described. The propulsion power processor generated the regulated dc voltages and currents from a solar array source of a solar electric propelled spacecraft. The power processor consisted of 12 power supplies that provide the regulated voltages and currents necessary to power a 30-cm mercury ion thruster. The design options for processing unregulated solar array power and for generating the regulated power required by each supply are studied. The technical approaches utilized in the developed design and the technological limitation of the identified design options are discussed. Alternate approaches for delivering power to a number of mercury ion thrusters and methods of optimizing are described. It was concluded that this power processor design should be considered for application in solar electric propulsion missions of the future.

Costogue, E. N.↗

Battery life test using reconditioning

A discussion is presented on nickel cadmium battery life tests using reconditioning and some comparative tests not using reconditioning. The discussion is aimed at the program application part of the testing. The goals of the program were to get an increased utilization out of the battery system in geosynchronous orbit. An attempt was made to push the depth of discharge operation up around 80 to 85 percent and the intent with the reconditioning program was to extend this type of utilization out towards a 10-year life and attune the voltage regulation.

Sparks, R. H.↗

Regulation of nitrogen uptake and assimilation: Effects of nitrogen source, root-zone pH, and aerial CO2 concentration on growth and productivity of soybeans

An important feature of controlled-environment crop production systems such as those to be used for life support of crews during space exploration is the efficient utilization of nitrogen supplies. Making decisions about the best sources of these supplies requires research into the relationship between nitrogen source and the physiological processes which regulate vegetative and reproductive plant growth. Work done in four areas within this research objective is reported: (1) experiments on the effects of root-zone pH on preferential utilization of NO3(-) versus NH4(+) nitrogen; (2) investigation of processes at the whole-plant level that regulate nitrogen uptake; (3) studies of the effects of atmospheric CO2 and NO3(-) supply on the growth of soybeans; and (4) examination of the role of NO3(-) uptake in enhancement of root respiration.

Raper, C. D.↗

Xylanolytic metabolism is regulated by coordination of transcription factors XynR and XylR in extremely thermophilic Caldicellulosiruptorales

ABSTRACT Global transcription factors (TFs) control metabolic processes in bacteria to efficiently utilize available carbon. The orderCaldicellulosiruptoraleshas drawn interest due to the ability of its members to degrade components of lignocellulosic biomass. Regulatory reconstruction ofAnaerocellum (f. Caldicellulosiruptor) besciiidentified two major global transcription factors for xylan utilization, XynR and XylR, and the corresponding putative transcription factor binding sites. Recombinant versions of XynR (LacI family) and XylR (ROK family) were subjected to fluorescence polarization (FP) and biolayer interferometry (BLI) analysis to confirm the predicted binding sites. Four XynR sites and two XylR sites were validated, accounting for 20 of 26 genes regulated by XynR and six of seven genes regulated by XylR. Bioinformatic analysis of the individual genes controlled by the two regulators showed an inter-dependent scheme for xylan conversion; the transport of xylooligosaccharides (XOS) is dependent on XylR, while enzymes responsible for hydrolysis are controlled by both regulators. For xylose catabolism by the xylose isomerase-xylulose kinase pathway, regulation is also split, with XylR controlling xylose isomerase and XynR controlling xylokinase. The XynR/XylR regulator pair withinA. besciiis conserved in all sequenced species ofCaldicellulosiruptorales, suggesting similarities in regulating linear xylan conversion. In other xylanolytic thermophiles, XylR homologs control xylan degradation, compared to just 6 out of 26 genes forA. bescii. These results show that two separate regulatory schemes (dual repression) are coordinated byA. besciito effectively regulate the hemicellulose inventory and xylan catabolism. IMPORTANCE To take full advantage of extreme thermophiles as platform metabolic engineering microorganisms, the tools for genetic manipulation must be further developed, and strategies that exploit a better understanding of metabolic regulation need to be discerned.Anaerocellum bescii, the most studied of the extremely thermophilic fermentative anaerobic bacteria that can utilize microcrystalline cellulose, can degrade microcrystalline cellulose and hemicellulose and has been metabolically engineered to convert the resulting sugars to products such as ethanol and acetone. For xylan, in particular, two major global transcription factors (TFs), XynR and XylR, play a role in sugar metabolism, although their predicted regulatory interdependence from bioinformatics analysis has not been elucidated experimentally. Here, fluorescence polarization (FP) and biolayer interferometry (BLI) were used to explore this issue to support metabolic engineering efforts aimed at improving carbohydrate processing to industrial chemicals.

Biotechnology & Applied Microbiology↗

High-throughput genetics enables identification of nutrient utilization and accessory energy metabolism genes in a model methanogen

Archaea are widespread in the environment and play fundamental roles in diverse ecosystems; however, characterization of their unique biology requires advanced tools. This is particularly challenging when characterizing gene function. Here, we generate randomly barcoded transposon libraries in the model methanogenic archaeon Methanococcus maripaludis and use high-throughput growth methods to conduct fitness assays (RB-TnSeq) across over 100 unique growth conditions. Using our approach, we identified new genes involved in nutrient utilization and response to oxidative stress. We identified novel genes for the usage of diverse nitrogen sources in M. maripaludis including a putative regulator of alanine deamination and molybdate transporters important for nitrogen fixation. Furthermore, leveraging the fitness data, we inferred that M. maripaludis can utilize additional nitrogen sources including $\tiny{L}$-glutamine, $\tiny{D}$-glucuronamide, and adenosine. Under autotrophic growth conditions, we identified a gene encoding a domain of unknown function (DUF166) that is important for fitness and hypothesize that it has an accessory role in carbon dioxide assimilation. Finally, comparing fitness costs of oxygen versus sulfite stress, we identified a previously uncharacterized class of dissimilatory sulfite reductase-like proteins (Dsr-LP; group IIId) that is important during growth in the presence of sulfite. When overexpressed, Dsr-LP conferred sulfite resistance and enabled use of sulfite as the sole sulfur source. The high-throughput approach employed here allowed for generation of a large-scale data set that can be used as a resource to further understand gene function and metabolism in the archaeal domain.

59 BASIC BIOLOGICAL SCIENCES↗

Ten questions concerning energy flexibility in buildings

Demand side energy flexibility is increasingly being viewed as an essential enabler for the swift transition to a low-carbon energy system that displaces conventional fossil fuels with renewable energy sources while maintaining, if not improving, the operation of the energy system. Building energy flexibility may address several challenges facing energy systems and electricity consumers as society transitions to a low-carbon energy system characterized by distributed and intermittent energy resources. For example, by changing the timing and amount of building energy consumption through advanced building technologies, electricity demand and supply balance can be improved to enable greater integration of variable renewable energy. Although the benefits of utilizing energy flexibility from the built environment are generally recognized, solutions that reflect diversity in building stocks, customer behavior, and market rules and regulations need to be developed for successful implementation. In this paper, we pose and answer ten questions covering technological, social, commercial, and regulatory aspects to enable the utilization of energy flexibility of buildings in practice. In particular, we provide a critical overview of techniques and methods for quantifying and harnessing energy flexibility. We discuss the concepts of resilience and multi-carrier energy systems and their relation to energy flexibility. We argue the importance of balancing stakeholder engagement and technology deployment. Finally, we highlight the crucial roles of standardization, regulation, and policy in advancing the deployment of energy flexible buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Business Models for Coal Plant Decommissioning

Aging coal-fired power plants are retiring across the United States. Researchers at Pacific Northwest National Laboratory studied coal-fired power plant decommissioning business models to support program development for the Department of Energy’s Office of Energy Efficiency & Renewable Energy (EERE) to engage with communities affected by power plant retirement processes. Evaluating and reducing the impact on coal-dependent communities from phasing out coal production is a crucial piece of nationwide economic development and community-directed engagement in the clean energy future. This report describes the steps in the typical coal-fired power plant decommissioning process, including analysis of the following key factors: Drivers including policy and regulations, competition with other fuels, and corporate responsibility goals; Types of coal plant decommissioning including plant retirement without full decommissioning, repurposing with fuel switch, redeveloping to utilize existing transmission, and decommissioning and repurposing with other commercial activities; and, Costs of coal plant decommissioning, including variations across regulated and deregulated markets and the funding resources to support decommissioning activities. The details described in this report relied heavily on the availability of local news reports and communications regarding plant retirements, as the researchers identified a lack of formal literature surrounding business models for coal plant decommissioning and a need for a more robust source material collection. In addition, a lack of oversight entities responsible for decommissioning processes may have led to this shortfall of information. Future research regarding coal plant decommissioning can include quantitative studies on power plant retirement drivers, procedures, and costs, qualitative assessments on affects decommissioning has on surrounding communities, investors, and other stakeholders, and identifying best practices to engage community stakeholders in the decommissioning process.

01 COAL, LIGNITE, AND PEAT↗

Performance Evaluation of Hierarchical Controls for Advanced Distribution Management System-Centered Grid Operations: Preprint

This paper presents a hardware-in-the-loop (HIL) platform to evaluate the performance of voltage regulation using an advanced distribution management system (ADMS) for grid operations to control legacy and grid-edge voltage control devices and coordinate with distributed energy management systems (DERMS) to manage high penetrations of photovoltaics (PV) on a utility distribution system. The HIL platform provides realistic laboratory testing, including accurate modeling (legacy devices, grid-edge devices, and PV) of the real-world distribution system from a utility partner, a real controller (ADMS), software controller DERMS, hardware grid-edge devices, and standard communications protocols. The test results show proper functionalities of the integrated platform and the performance of voltage regulation of the coordinated control systems. Based on laboratory testing, the utility can set up the same grid-automation system to manage DERs, legacy devices, and grid-edge devices to achieve their system-level control and operation objectives (e.g., voltage regulation), thus de-risking potential issues (e.g., instability) for field deployment.

ADMS↗

End-Use Load Profiles for the U.S. Building Stock: Practical Guidance on Accessing and Using the Data

End-use load profiles (EULP), which quantify how and when energy is used, are critically important to utilities, public utility commissions, state energy offices, and other stakeholders. Applications of EULPs focus on understanding how efficiency, demand response, and other distributed energy resources are valued and used in R&D prioritization, utility resource and distribution system planning, and state and local energy planning and regulations. Consequently, high-quality EULPs are critical for widespread adoption of electrification, demand flexibility, and grid-interactive efficient buildings. For example, EULPs can be used to forecast energy savings in buildings or to identify energy using activities that can be shifted to different times of the day.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Topology-Aware Reinforcement Learning for Voltage Control: Centralized and Decentralized Strategies

Volt-VAR control (VVC) methods based on deep reinforcement learning (DRL) can effectively control distribution grid voltage and minimize power loss by implementing corrective and preventive control measures on the reactive power output of inverter-based distributed energy resources (DERs). However, model-free DRL-based VVC approaches usually cannot capture the important topological feature of the power system since they use a fully-connected network (FCN) to deliver the action. Therefore, this paper proposes a graph convolutional network (GCN)-based DRL approach that can employ the topological information of the network to take better control action for regulating the voltage. Our implementation allows for both centralized and decentralized configurations, utilizing a single agent and multiple agents respectively. Although the centralized GCN-based DRL approach has its advantages of minimizing voltage fluctuation and power loss, it is not suitable for large scale power systems due to its challenges in terms of scalability, computation speed and potential single points of failure. Therefore, these problems can be resolved using the decentralized GCN-based DRL approach. Moreover, to ensure the safe operation of the model, our proposed approach incorporates an exponential barrier function while formulating the reward function for each agent. To validate performance of the proposed approaches, the proposed model is tested on modified IEEE test systems and the performances are measured in terms on voltage fluctuation reduction, minimization of power loss and computational speed. Finally, the results show that the proposed topology-aware approach outperforms the FCN-based DRL approach in terms of reducing voltage fluctuation and minimizing power loss of the network. Moreover, it is shown that the decentralized GCN-based DRL has faster computational speed than other approaches.

42 ENGINEERING↗

Economic comparison of fabric filters and electrostatic precipitators for particulate control on coal-fired utility boilers

The uncertainties and associated costs involved in selecting and designing a particulate control device to meet California's air emission regulations are considered. The basic operating principles of electrostatic precipitators and fabric filters are discussed, and design parameters are identified. The size and resulting cost of the control device as a function of design parameters is illustrated by a case study for an 800 MW coal-fired fired utility boiler burning a typical southwestern subbituminous coal. The cost of selecting an undersized particulate control device is compared with the cost of selecting an oversized device.

Cukor, P. M.↗

Extraction of Mercury Utilizing 3D Printed Media - Mercury Extraction Coalescer (MEC)

Mercury is a persistent environmental hazard that is strictly regulated. The design of a 3D printed coalescer was proposed to facilitate segregation and/or adsorption of elemental mercury from aqueous solutions. 3D printing techniques were employed to generate designed surfaces and internal geometries that would otherwise be very difficult to near impossible through traditional manufacturing processes. The proposed coalescer was designed to take advantage of advancements in 3D printing to incorporate surface sub-structures and material compositions targeted specifically at mercury adsorption. The initial phase of research targeted the design of physical structures that could assist with adsorption or segregation of mercury from acidic condensate, rendering it isolated and preventing recirculation back into the chemical process, as well as implementation into standard environmental remediation techniques for contaminated aqueous solutions. Future work was to focus on formulating reactive coalescers to improve chemisorption along with physisorption.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Evaluation of Data-Enhanced Hierarchical Control for Grid Operations

This paper presents a hardware-in-the-loop (HIL) simulation to evaluate the performance of voltage regulation of Data-Enhanced Hierarchical Control (DEHC). This DEHC uses an advanced distribution management system (ADMS) for grid operations to control legacy and grid-edge devices and coordinate with distributed energy management systems (DERMS) to manage high penetrations of photovoltaics (PV) on a utility distribution system. The HIL platform provides realistic laboratory testing, including accurate modeling (legacy devices, grid-edge devices, and PV) of the real-world distribution system from a utility partner, a real controller (ADMS), software controller DERMS, hardware grid-edge devices, and standard communications protocols. The test results demonstrate functionalities of the integrated platform and the performance of voltage regulation of the coordinated control systems. Based on laboratory testing, the utility can set up the same grid-automation system to manage DERs, legacy devices, and grid-edge devices to achieve their system-level control and operation objectives (e.g., voltage regulation), thus de-risking potential issues such as instability for field deployment.

41 EE - Solar Energy Technologies Office (EE-4S)↗