At least 433 records · Page 24

Long lifetime hollow cathodes for 30-cm mercury ion thrusters

An experimental investigation of hollow cathodes for 30-cm Hg bombardment thrusters was carried out. Both main and neutralizer cathode configurations were tested with both rolled foil inserts coated with low work function material and impregnated porous tungsten inserts. Temperature measurements of an impregnated insert at various positions in the cathode were made. These, along with the cathode thermal profile are presented. A theory for rolled foil and impregnated insert operation and lifetime in hollow cathodes is developed. Several endurance tests, as long as 18,000 hours at emission currents of up to 12 amps were attained with no degradation in performance.

Mirtich, M. J.↗

Thermionic energy conversion technology - Present and future

Aerospace and terrestrial applications of thermionic direct energy conversion and advances in direct energy conversion (DEC) technology are surveyed. Electrode materials, the cesium plasma drop (the difference between the barrier index and the collector work function), DEC voltage/current characteristics, conversion efficiency, and operating temperatures are discussed. Attention is centered on nuclear reactor system thermionic DEC devices, for in-core or out-of-core operation. Thermionic fuel elements, the radiation shield, power conditions, and a waste heat rejection system are considered among the thermionic DEC system components. Terrestrial applications include topping power systems in fossil fuel and solar power generation.

Shimada, K.↗

Status of research on advanced thermionic converters

It is shown that it is possible to controllably and continuously elevate the electron temperature in the plasmatron thermionic energy converter from the emitter temperature to the maintenance electron temperature for the diode arc mode. This ability and the apparent validity of an elementary analytical model of the plasma should make possible the optimization and evaluation of operation under strong ionization conditions for which the plasma resistance should be acceptably low. Measurement of the vacuum space charge arising from the emission from a surface in cesium vapor indicates the presence of a substantial negative ion emission current. Apparatus has been constructed for identifying and directly measuring the flux of positive, negative and neutral species emitted from an electrode surface in a cesium vapor diode. The primary purpose of the investigation is to determine the influence of negative ion emission on the effective work function of thermionic converter electrodes. Initial data indicate the presence of H(-), Cs(-) and possibly C(-) and CH(-).

Hatch, G. L.↗

Low arc drop hybrid mode thermionic converter

The hybrid mode operation for the reduction of plasma drops is being investigated. This report discusses the results obtained from two molybdenum emitter converters. One converter had a molybdenum collector and the other a nickel collector. The molybdenum collector converter was operated in a hybrid mode (at an interelectrode distance of 1.7 mm) and produced a minimum barrier index of 1.96 eV at an emitter temperature of 1500 K. The arc drop was calculated to be 0.14 eV, using the published results for a molybdenum collector. On the other hand, the nickel collector converter was operated in a conventional ignited mode (at an interelectrode distance of 0.5 mm) and produced a minimum barrier index of 2.1 eV at an emitter temperature of 1700 K. It is tentatively concluded that a large-gap operation of the hybrid mode converter permits the diffusion of cesium ions to a distance in the order of one millimeter for an effective neutralization of electron space charge. By employing a low work function collector (1.55 eV) in a hybrid mode converter with an arc drop of 0.14 eV, it appears that a barrier index as low as 1.69 eV could be achieved.

Shimada, K.↗

The adsorption and early stages of condensation of Ag and Au on W single-crystal surfaces

Silver and gold were evaporated up to several monolayers in thickness onto W single-crystal surfaces of the 110 and 100 plane types in the temperature range between 300 and 1300 K. The mode of growth and the structure of the layers were studied by Auger electron spectroscopy and low-energy electron diffraction. The results are compared with thermal desorption spectroscopy data and work-function change measurements. They show certain similarities but also some striking differences between the two systems Ag/W and Au/W as well as a strong crystallographic anisotropy of adsorption and condensation.

Bauer, E.↗

Manufacture of ionizers intended for electric propulsion

An electric propulsion system which relies on the formation of cesium ions in contact with a porous wall made of a metal with a high work function when the wall is heated to 1500 K was described. The manufacture of porous walls on the mountings was considered. Erosion of the electrodes by slow ions was examined, and the life times of the ionizers was estimated by means of experimental studies. The purpose of the electric propulsion system was to bring about minor corrections in the orbits of geostationary satellites; the main advantage of this system was that it weighs less than currently used hydrazine systems.

Hivert, A.↗

Diminiode thermionic energy conversion with lanthanum-hexaboride electrodes

Thermionic conversion data obtained from a variable gap cesium diminiode with a hot pressed, sintered lanthanum hexaboride emitter and an arc melted lanthanum hexaboride collector are presented. Performance curves cover a range of temperatures: emitter 1500 to 1700 K, collector 750 to 1000 K, and cesium reservoir 370 to 510 K. Calculated values of emitter and collector work functions and barrier index are also given.

Kroeger, E. W.↗

ERDA-NASA advanced thermionic technology program

Research is summarized on surface studies (work functions of different LaB6 surfaces), plasma studies, converter development (tungsten emitter, nickel collector and tungsten emitter La B6 collector), and hot shell development for using thermionic converters in the topping cycle of fossil-fuel plants.

Source record↗

Anode power in quasisteady magnetoplasmadynamic accelerators

Anode heat flux in a quasi-steady MPD accelerator has been measured directly and locally by thermocouples attached to the inside surface of a shell anode. These measurements show that over a range of arc current from 5.5 to 44 kA, and argon mass flow from 1 to 48 g/s, the fraction of the total arc power deposited in the anode decreases from 50% at 200 kW to 10% at 20 MW. A theoretical model of the anode heat transfer asserts that energy exchange between electrons and heavy particles in the plasma near the anode occurs over distances greater than the anode sheath thickness, and hence the usual anode fall voltage, electron temperature, and work function contributions to the anode heat flux are supplemented by a contribution from the interelectrode potential. Calculations of anode heat flux using the measured current density, plasma potential, and electron temperature in the plasma adjacent to the anode agree with the direct measurements and indicate that the decrease in anode power fraction at higher arc powers can be attributed to the smaller mean free paths in the interelectrode plasma.

Saber, A. J.↗

A hollow cathode hydrogen ion source

High current density ion sources have been used to heat plasmas in controlled thermonuclear reaction experiments. High beam currents imply relatively high emission currents from cathodes which have generally taken the form of tungsten filaments. This paper describes a hydrogen ion source which was primarily developed to assess the emission current capability and design requirements for hollow cathodes for application in neutral injection devices. The hydrogen source produced ions by electron bombardment via a single hollow cathode. Source design followed mercury ion thruster technology, using a weak magnetic field to enhance ionization efficiency. A 1.3-cm-diam hollow cathode using a low work function material dispenser performed satisfactorily over a discharge current range of 10-90 A. Cylindrical probe measurements taken without ion extraction indicate maximum ion number densities on the order of 10 trillion/cu cm. Discharge durations ranged from 30 sec to continuous operation. Tests with beam extraction at 2.5 keV and 30 A discharge current yield average ion beam current densities of 0.1 A/sq cm over a 5-cm extraction diameter. Results of this study can be used to supply the baseline information needed to scale hollow cathodes for operation at discharge currents of hundreds of amperes using distributed cathodes.

Sovey, J. S.↗

Diminiode thermionic energy conversion with lanthanum-hexaboride electrodes

This paper presents thermionic-conversion data obtained from a variable-gap cesium diminiode with a hot-pressed, sintered lanthanum-hexaboride emitter and an arc-melted lanthanum-hexaboride collector. Performance curves cover a range of temperatures: emitter 1500 to 1700 K, collector 750 to 1000 K, and cesium reservoir 370 to 510 K. Calculated values of emitter and collector work functions and barrier index are also given.

Kroeger, E. W.↗

A proposed physical model for the impregnated tungsten cathode based on Auger surface studies of the Ba-O-W system

Auger spectra and work function measurements are used to study the surface reactions between tungsten surface and adsorbed layers of barium, and barium and oxygen. The barium on an impregnated tungsten cathod seems to be an intermediate state, probably a coadsorbed barium-oxygen layer on tungsten. A slightly revised version of the previously suggested (1976) impregnated tungsten cathode model is proposed. This revised model assumes that the cathode surface during life has an adsorbed surface layer of a monolayer or less of both barium and oxygen on the surface. At end of life, steep drop in electron emission and resultant cathode failure occur. Recent NASA life test results on TWT type tubes are reported and explained by the proposed model.

Forman, R.↗

Thermionic energy converter investigations

This paper presents evaluation of a variety of thermionic converter configurations to obtain improved efficiency. A variable-spacing diode using an iridium emitter gave emission properties comparable to platinum, but the power output from a sintered LaB6 collector diode was not consistent with its work function. Reflectivities above 0.5 were measured at thermal energies on oxygenated-cesiated surfaces using a field emission retarding potential gun. Performance of converters with structured electrodes and the characteristics of a pulsed triode were studied as a function of emitter, collector, cesium reservoir, interelectrode spacing, xenon pressure, and pulsing parameters.

Goodale, D. B.↗

Fabrication and surface characterization of composite refractory compounds suitable for thermionic converters

The techniques of fabricating and characterizing the surface properties of electrode materials were investigated. The basic surface properties of these materials were studied with respect to their utilization as thermionic energy converter electrodes. Emphasis was placed on those factors (e.g, cesium disorption kinetic and mechanisms of low work function production) which are of primary concern to thermionic converter performance.

Davis, P. R.↗

Comparison of the early stages of condensation of Cu and Ag on Mo/100/ with Cu and Ag on W/100/

The adsorption and condensation of Cu and Ag, up to several monolayers in thickness, onto Mo(100) has been observed at pressures below 2 times 10 to the -10th torr in a study that used combined LEED, Auger, TDS (Thermal Desorption Spectroscopy), and work function measurements in a single experimental setup. The results show that Cu behaves similarly on Mo(100) and W(100) substrates, while some differences are found for Ag adsorption.

Soria, F.↗

Electric energy production by particle thermionic-thermoelectric power generators

Thermionic-thermoelectric power generators, composed of a thin layer of porous, low work function material separating a heated emitter electrode and a cooler collector electrode, have extremely large Seebeck coefficients of over 2 mV/K and can provide significant output power. Preliminary experiments with 20-micron thick (Ba Sr Ca)O coatings, limited by evaporative loss to temperatures below 1400 K, have yielded short circuit current densities of 500 mA/sq cm and power densities of 60 mW/ sq cm. Substantially more output is expected with cesium-coated refractory oxide particle coatings operating at higher temperatures. Practical generators will have thermal-to-electrical efficiencies of 10 to 20%. Further increases can be gained by cascading these high-temperature devices with lower temperature conventional thermoelectric generators.

Oettinger, P. E.↗

Collector temperature effects on the performance of advanced thermionic converters and nuclear electric propulsion systems

The specific weight of a thermionic nuclear electric propulsion (NEP) system depends on the collector temperature because of changes in power density, efficiency and the temperature of heat rejection. Increasing the collector temperature above the value for maximum converter performance decreases both the efficiency and the power density of the converters, but the specific weight of the total system is decreased because of the reduction in radiator weight due to the increased heat rejection temperature. The effect of collector temperature on the performance of thermionic converters was investigated. The behavior of conventional ignited mode converters as well as advanced converters with lower collector work functions; the specific mass of an 'uninsulated' NEP system design was then evaluated as a function of collector temperature. The uninsulated design uses the electrical resistance of the heat pipes between the converters and the reactor to provide electrical insolation, eliminating the need for ceramic insulators at emitter temperature and providing other design advantages. The results indicate that an optimum collector temperature, which minimizes system weight, exists at a temperature above the optimum temperature for converter performance.

Dick, R. S.↗

Heat flux at the thermionic collector

Heat flux arriving at the thermionic collector is theoretically considered to be composed of an electron heating term, proportional to the output current, plus the radiation and conduction terms. However, the measured electron heating term is always larger than what one would expect from the accepted theory. In this paper, the electron heating term at the collector is theoretically calculated as a sum of the conventional electron heating term and the heat flux which is carried into the collector by the random plasma current. The arriving random electrons and ions are considered to recombine nonradiatively at the collector surface after imparting their kinetic energies to the collector, in addition to the ionization potential energy. In this process, random electrons do not lose their potential energy equal to the collector work function, since they do not contribute to the output current.

Shimada, K.↗