Search NASA⌕ Search

SEARCH · Search NASA

Results for “border”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Whole-breast irradiation: a subgroup analysis of criteria to stratify for prone position treatment

To select among breast cancer patients and according to breast volume size those who may benefit from 3D conformal radiotherapy after conservative surgery applied with prone-position technique. Thirty-eight patients with early-stage breast cancer were grouped according to the target volume (TV) measured in the supine position: small ({<=}400 mL), medium (400-700 mL), and large ({>=}700 ml). An ad-hoc designed and built device was used for prone set-up to displace the contralateral breast away from the tangential field borders. All patients underwent treatment planning computed tomography in both the supine and prone positions. Dosimetric data to explore dose distribution and volume of normal tissue irradiated were calculated for each patient in both positions. Homogeneity index, hot spot areas, the maximum dose, and the lung constraints were significantly reduced in the prone position (p < 0.05). The maximum heart distance and the V{sub 5Gy} did not vary consistently in the 2 positions (p = 0.06 and p = 0.7, respectively). The number of necessary monitor units was significantly higher in the supine position (312 vs. 232, p < 0.0001). The subgroups analysis pointed out the advantage in lung sparing in all TV groups (small, medium and large) for all the evaluated dosimetric constraints (central lung distance, maximum lung distance, and V{sub 5Gy}, p < 0.0001). In the small TV group, a dose reduction in nontarget areas of 22% in the prone position was detected (p = 0.056); in the medium and high TV groups, the difference was of about -10% (p = NS). The decrease in hot spot areas in nontarget tissues was 73%, 47%, and 80% for small, medium, and large TVs in the prone position, respectively. Although prone breast radiotherapy is normally proposed in patients with breasts of large dimensions, this study gives evidence of dosimetric benefit in all patient subgroups irrespective of breast volume size.

61 RADIATION PROTECTION AND DOSIMETRY↗

Field match verification during combination proton, photon, and electron therapy for oligometastatic inflammatory breast cancer

Postmastectomy radiation therapy (PMRT) has been shown in randomized trials to improve overall survival for patients with locally advanced breast cancer. The standard PMRT clinical target volume (CTV) encompasses the chest wall and undissected regional lymphatics. Conformal isodose distributions covering the standard CTV with acceptable dose limits to normal tissue can typically be achieved with a combination of photon and electron fields. Field borders are marked on the patient's skin using a light field projection of each beam and are subsequently used to verify daily field matching clinically. Initial imaging of a patient with oligometastatic inflammatory breast cancer demonstrated direct extension of disease from the involved internal mammary lymph node chain into the anterior mediastinum as the only site of metastatic disease. The patient achieved a pathologic complete response to neoadjuvant chemotherapy and underwent mastectomy. The initial sites of gross disease, including the anterior mediastinal node was included in the CTV for PMRT, and treatment planning demonstrated a clear advantage to the inclusion of proton fields in this case. The absence of a light source on the proton delivery system that accurately projects proton field edges onto the patient's skin posed a significant challenge for daily verification of proton-to-photon and -electron field matching. Proton field-specific radiographic imaging devices were designed and used such that proton field edges could be delineated on the patient's skin and used for daily matching with photon and electron fields. Manufacture of the imaging devices was quick and inexpensive. Weekly verification of proton field alignment with the proton field delineation on the skin demonstrated agreement within 3-mm tolerance. The patient remains with no evidence of disease 18 months after completing radiation. Other patients with similar indications may benefit from multimodality radiation therapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Prostate treatment with helical TomoTherapy in patients with bilateral hip prostheses—Two case studies

Prostate cancer patients with bilateral hip prostheses require additional planning and treatment considerations. Visualization of the organs at risk (OAR) and the planning target volume (PTV) is hindered by the large amount of artifact streaking between the metallic implants. The density of this area must be accounted for when using heterogeneity correction. Fusion of a megavolt computed tomography (MVCT) to the planning CT aids in viewing the prostate, bladder, and rectum, and implantation of 6 fiducial markers along the posterior border of the prostate helps with the delineation between it and the rectum. When planning, the amount of beam entry angles is limited because of the position of the prostheses and prevents the use of any lateral beams. Therefore, TomoTherapy presents an effective option for these patients because of the ability to use a directional block, which prevents any primary beams from entering through the bilateral hip prostheses (but the beams may exit through the structures), use of MVCT for daily localization, and delivery of radiation with intensity modulation allows for effective sparing of the OAR.

61 RADIATION PROTECTION AND DOSIMETRY↗

Whole-brain Irradiation Field Design: A Comparison of Parotid Dose

Whole-brain radiation therapy (WBRT) plays an important role in patients with diffusely metastatic intracranial disease. Whether the extent of the radiation field design to C1 or C2 affects parotid dose and risk for developing xerostomia is unknown. The goal of this study is to examine the parotid dose based off of the inferior extent of WBRT field to either C1 or C2. Patients treated with WBRT with either 30 Gy or 37.5 Gy from 2011 to 2014 at a single institution were examined. Parotid dose constraints were compared with Radiation Therapy Oncology Group (RTOG) 0615 nasopharyngeal carcinoma for a 33-fraction treatment: mean <26 Gy, volume constraint at 20 Gy (V20) < 20 cc, and dose at 50% of the parotid volume (D50) < 30 Gy. Biologically effective dose (BED) conversions with an α/β of 3 for normal parotid were performed to compare with 10-fraction and 15-fraction treatments of WBRT. The constraints are as follows: mean < BED 32.83 Gy, V15.76 (for 10-fraction WBRT) or V17.35 (for 15-fraction WBRT) < 20 cc, and D50 < BED 39.09 Gy. Nineteen patients treated to C1 and 26 patients treated to C2 were analyzed. Comparing WBRT to C1 with WBRT to C2, the mean left, right, and both parotids' doses were lower when treated to C1. Converting mean dose to BED{sub 3}, the parotid doses were lower than BED{sub 3} constraint of 32.83 Gy: left (30.12 Gy), right (30.69 Gy), and both parotids (30.32 Gy). V20 to combined parotids was lower in patients treated to C1. When accounting for fractionation of WBRT received, the mean corrected V20 volume was less than 20 cc when treating to C1. D50 for C1 was lower than C2 for the left parotid, right parotid, and both parotids. BED{sub 3} conversion for the mean D50 of the left, right, and both parotids was less than 39.09 Gy. In conclusion, WBRT to C1 limits parotid dose, and parotid dose constraints are achievable compared with inferior border at C2. A possible mean parotid dose constraint with BED{sub 3} should be less than 32.83 Gy.

61 RADIATION PROTECTION AND DOSIMETRY↗

SORIS - A standoff radiation imaging system

The detection of radiological and special nuclear material within the country’s borders is a crucial component of the national security network. Being able to detect small amounts of radiological material at large distances is especially important for search applications. To provide this capability General Electric’s Research Center has developed, as a part of DNDO’s standoff radiation detection system advanced technology demonstration (SORDS-ATD) program, a standoff radiation imaging system (SORIS). This vehicle-based system is capable of detecting weak sources at large distances in relatively short times. To accomplish this, GE has developed a novel coded aperture detector based on commercial components from GE Healthcare. An array of commercial gamma cameras modified to increase the system efficiency and energy range are used as position sensitive detectors. Unlike typical coded aperture systems, however, SORIS employs a non-planar mask and thus does not suffer the typical limitations of partially encoded regions giving it a wide field of view. Source identification is done using both low-statistics anomaly indicators and conventional high-statistics algorithms being developed by Pacific Northwest National Laboratory. The results of scanned areas and threats identified are displayed to the user and overlaid on satellite imagery.commercial components from GE Healthcare. An array of commercial gamma cameras modified to increase the system efficiency and energy range are used as position sensitive detectors. Unlike typical coded aperture systems, however, SORIS employs a non-planar mask and thus does not suffer the typical limitations of partially encoded regions giving it a wide field of view. Source identification is done using both low-statistics anomaly indicators and conventional high-statistics algorithms being developed by Pacific Northwest National Laboratory. The results of scanned areas and threats identified are displayed to the user and overlaid on satellite imagery.

Coded aperture imager↗

Optimizing moderation of He-3 neutron detectors for shielded fission sources

Abstract: The response of 3-He neutron detectors is highly dependent on the amount of moderator incorporated into the detector system. If there is too little moderation, neutrons will not react with the 3-He. If there is too much moderation, neutrons will not reach the 3-He. In applications for portal or border monitors where 3He detectors are used to interdict illicit Importation of plutonium, the fission source is always shielded to some extent. Since the energy distribution of neutrons emitted from the source depends on the amount and type of shielding present, the optimum placement of moderating material around 3-He tubes is a function of shielding. In this paper, we use Monte Carlo techniques to model the response of 3-He tubes placed in polyethylene boxes for moderation. To model the shielded fission neutron source, we use a 252-Cf source placed in the center of spheres of water of varying radius. Detector efficiency as a function of box geometry and shielding are explored. We find that increasing the amount of moderator behind and to the sides of the detector generally improves the detector response, but that benefits are limited if the thickness of the polyethylene moderator is greater than about 5-7 cm. The thickness of the moderator in front of the 3He tubes, however, is very important. For bare sources, about 5-6 cm of moderator is optimum, but as the shielding increases, the optimum thickness of this moderator decreases to 0-1 cm. A two-tube box with a moderator thickness of 5 cm in front of the first tube and a thickness of 1 cm in front of the second tube is proposed to improve the detector's sensitivity to lower-energy neutrons.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Root cause analysis and solutions for plastic gamma detector degradation in challenging environments—An overview

Polyvinyl toluene (PVT) plastic is often used to make gamma ray sensitive scintillators and is used in many important applications. For example, PVT is used to scan recycled steel going into a plant to be processed. It is also used in personnel portals to scan employees, and is used at the borders of many countries to scan cargo and cars passing through. In recent years, it was discovered that PVT can become degraded when it absorbs water and then is subjected to daily temperature swings, as is evidence by a reduction in scintillation light. Water absorption by PVT was notionally associated with temporary fogging (i.e., a rapid decrease in opacity which was reversible over time) and permanent fogging (i.e., permanent crack-like defects) and was for some time suspected to be the leading cause of the fogging due to circumstantial evidence. However, definitive proof was not established and in particular the specific mechanisms by which water entered the plastic and ultimately created temporary and permanent point-like defects was not fully understood. This paper is an overview of an effort initiated to reveal the fundamental root cause and also the dynamics of the fogging and degradation processes. This understanding is important not only to solve degradation problems for PVT in fielded systems, but also (1) to provide direction for future procurements for new equipment, and (2) to provide direction for future R&D efforts into advanced plastics with enhanced spectroscopic capabilities or dual particle gamma/neutron capabilities. Unexpected outcomes of this investigation included (1) the capability to predict the onset of fogging based on models using weather data alone, and (2) new modified formulations of PVT and PS which are fog-resistant. This paper provides an overview of the water uptake and associated mechanisms for various compositions, characterization of resulting temporary and permanent defects, predictive modeling of fogging, and possible solutions including encapsulation, heaters and new formulations. While this paper is an overview of the root cause analysis and solution, five accompanying papers (Lance et al., 2018, Myllenbeck and Feng, 2018, Payne et al., 2018, Zaitseva et al. 2018, Kouzes et al., 2018) from the same conference (SORMA 2018) delve further into the details and also expand upon the scope of what will be reported herein.

36 MATERIALS SCIENCE↗

Effect of natural gamma background radiation on portal monitor radioisotope unmixing

It is well known that national security relies on several layers of protection. One of the most important is the traffic control at borders and ports that exploits Radiation Portal Monitors (RPMs) to detect and deter potential smuggling attempts. Most portal monitors rely on plastic scintillators to detect gamma rays. Despite their poor energy resolution, their cost effectiveness and the possibility of growing them in large sizes make them the gamma-ray detector of choice in RPMs. Unmixing algorithms applied to organic scintillator spectra can be used to reliably identify the bare and unshielded radionuclides that triggered an alarm, even with fewer than 1000 detected counts and in the presence of two or three nuclides at the same time. In this work, we experimentally studied the robustness of a state-of-the-art unmixing algorithm to different radiation background spectra, due to varying atmospheric conditions, in the 16 °C to 28 °C temperature range. In the presence of background, the algorithm is able to identify the nuclides present in unknown radionuclide mixtures of three nuclides, when at least 1000 counts from the sources are detected. With fewer counts available, we found larger differences of approximately 35.9% between estimated nuclide fractions and actual ones. In these low count rate regimes, the uncertainty associated by our algorithm with the identified fractions could be an additional valuable tool to determine whether the identification is reliable or a longer measurement to increase the signal-to-noise ratio is needed. Moreover, the algorithm identification performances are consistent throughout different data sets, with negligible differences in the presence of background types of different intensity and spectral shape.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Radiation portal monitor data file format for comprehensive background radiation monitoring

Radiation portal monitors (RPMs) are widely used at border security checkpoints to detect the presence of radioactive materials in people, vehicles, and cargo. Typically, RPM detection systems consist of two pillars equipped with gamma and neutron detectors. To improve detection efficiency, RPMs employ techniques such as a limited energy window, dynamic alarm thresholds, and lead shielding. However, without continuous monitoring of background radiation, signal interpretation can be compromised, because environmental factors and mechanical failures can cause fluctuations. Here, we introduce a daily file format that logs gamma background and neutron background radiation levels continuously over a 24 h period; this format is different from traditional formats that record data only when the RPM is active or occupied. The approach enables RPM operators and analysts to (1) identify and diagnose malfunctioning components, (2) adjust system settings to account for dynamic environmental factors, and (3) use the recorded data to characterize outer space phenomena. Continuous background reporting is essential for identifying issues such as faulty connections, voltage divider failures, and errors in background updates. Continuous background reporting also enables the detection of external influences, including nearby X-ray scanners, temperature fluctuations, rainfall, cosmic radiation, and lunar phase changes. These data files are designed to be easily evaluated and parsed using common tools, and a quick review by an expert is often sufficient for problem diagnosis. We anticipate that continuous background radiation monitoring and these new strategies will significantly improve the accuracy and reliability of RPM systems, reducing the rate of false alarms and enhancing overall system performance.

Background radiation monitoring↗

A generalized machine learning workflow to visualize mechanical discontinuity

Accurate detection and mapping of mechanical discontinuity in materials has widespread industrial and research applications. Herein, we developed a generalized machine-learning framework for visualizing single mechanical discontinuity embedded in material of any composition, velocity, density, porosity, and size with limited data. The proposed visualization of discontinuity requires accurate estimations of the length, location, and orientation of the embedded discontinuity by processing multipoint wave-transmission measurements. k-Wave simulator is used to create a large dataset of elastic waveforms recorded during multi-point wave-transmission measurements through materials containing single mechanical discontinuity. k-Wave simulator considers the wave attenuation, dispersion, and mode conversion in wave motion. Discrete wavelet transform (DWT) and statistical feature extraction are essential for data preprocessing prior to the data-driven model development. DWT also minimizes the effect of noise. Using hyper-parameter tuning and cross validation, gradient boosting regression can visualize the mechanical discontinuity with an accuracy of 0.85, in terms of coefficient of determination. A double-layered neural network-based regression has better performance with an accuracy of 0.95. Use of convolutional neural network converts the predictive task from a waveform processing to an image processing problem. Convolutional neural network achieved a generalization performance of 0.91. The proposed generalized workflow requires robust simulation of wave propagation, signal processing, feature engineering, and model evaluation. Sensors closest to the source and those located opposite the source are the most significant for the desired visualization. Notably, the sensors closest to the source capture the non-linear associations, whereas the sensor on the border opposite to the source capture the linear associations between the measured waveforms and the properties of the mechanical discontinuity.

42 ENGINEERING↗

Detecting ecological signatures of long-term human activity across an elevational gradient in the Šumava Mountains, Central Europe

Central European mountains, including the Šumava Mountains located along the Czechia/Germany border, have a long and rich anthropogenic history. Yet, documenting prehistoric human impact in Central European mountain environments remains a challenge because of the need to disentangle climate and human-caused responses in terrestrial systems. Here, we present the first reconstructed water table depths (WTDs) from two sites, Pěkná and Blatenská slať, located in the Šumava Mountains. We compare these local WTD records with new and published pollen, non-pollen palynomorphs (NPPs), plant macrofossils, geochemistry and archeological records to investigate how changes in local hydrology and human activities impacted forest succession and fire activity throughout the Holocene across an elevational gradient. Using a generalized additive model, our results suggest that changes in forest succession and fire activity have been primarily caused by climate throughout the Holocene. However, humans have been utilizing mountain environments and their resources continuously since ∼4600 cal yr BP, thus playing a secondary role in modifying forest succession to increase resources beneficial to both humans and grazers. Over the last 1000 years, we provide evidence of directly observed human-caused modifications to the landscape. These results contribute to a growing body of literature illustrating human activities and landscape modifications in Central European mountains.

54 ENVIRONMENTAL SCIENCES↗

A comprehensive academic and industrial survey of blockchain technology for the energy sector using fuzzy Einstein decision-making

The global energy sector is undergoing a significant transformation driven by decarbonization and digitalization, leading to the emergence of Distributed Ledger Technology (DLT) — particularly blockchain — as a promising tool for enhancing transparency, security, and efficiency in modern power systems. This study aims to provide a comprehensive academic and industrial survey of blockchain applications in the energy sector and develop a robust decision-making framework to identify and prioritize the most promising real-world use cases based on multidisciplinary criteria. A three-stage methodology was adopted: (i) a literature and market review encompassing over 300 academic publications and commercial blockchain initiatives in energy, (ii) an in-depth evaluation of the evolution and viability of blockchain initiatives in energy with the help of expert surveys, and (iii) a novel decision-making model using a q-rung orthopair fuzzy Multi-Attributive Border Approximation (q-ROF-MABAC) method under the Einstein operator. The results were compared with existing decision models to validate consistency and robustness. Nine key blockchain use case categories were identified and ranked based on technical, economic, and governance dimensions. The results demonstrated that integrating expert insights into a fuzzy logic framework helps filter out overhyped claims in the literature and prioritize realistic and high-impact applications such as green certificates, grid services, and peer-to-peer energy trading. The model’s rankings remained stable across varying weight configurations, confirming the robustness of the methodology. This study provides an evidence-based decision-support tool for researchers, industry stakeholders, and policymakers to better understand, evaluate, and adopt blockchain technologies in the energy sector.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Radon kinetics in a natural indoor radon chamber

An unusual 180 m 3 storage room in the basement of a two-story laboratory building is unventilated, and separated from occupiable rooms by double steel doors. The space completely borders on soil through the concrete floor and two of its concrete walls. The room also contains a separate inner chamber with 1 m thick concrete walls designed to damp vibrations in the room above it. The space boasts a relatively high radon level, 1083 Bq m –3 , which varies with local outdoor environmental conditions. Measurements were made of radon concentrations at various locations and heights within the facility. More than a year of continuous radon concentration data corresponding to a single location are also available, along with measurements of indoor and outdoor pressure, temperature, and humidity. Data were also collected with as many as five fans placed in different locations and cycled on for variable time periods. First order linear kinetic models were created to explain the observed approaches to steady state due to changing conditions and wash-out resulting from intentional ventilation. Results demonstrate a good fit between changes in the radon concentration level and the developed compartmental models. Furthermore, no significant differences were observed between radon concentration at different locations or heights in the chamber.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integrative investigation of dust emissions by dust storms and dust devils in North Africa

Dust aerosols in North Africa account for >50% of the global total; however dust emission areas are still unclear. Based on the analysis of dust storms simulated with the numerical Weather Research and Forecast (WRF) model, satellite aerosol index (AI), and the dust data observed at 300 meteorological stations over 20 years, the spatio-temporal distribution characteristics of dust storm, dust devil and AI are compared and analyzed. From this study, the results show that: 1) There are two dust emission mechanisms: the dynamically-dominated dust storm and thermally-dominated dust devil; 2) Dust storms occur most frequently in Spring and are concentrated in the areas of Grand Erg Occidental Desert to the Erg Chech-Adrar Desert, the northern part of Grand Erg Oriental, the Atouila Desert to the Ouarane Desert, the Mediterranean coast, the eastern side of Nubian Desert and Bodélé Depression; 3) Dust devils occur most frequently from April to August and are mainly concentrated in the central part of North Africa, especially in the southwest of Hoggar Mountains to the west of Air Mountains, the border area of Egypt - Sudan - Libya and the vicinity of Tibesti Plateau; 4) The spatio-temporal distribution of AI is correlated more with the dust devils emission whereas the annual average contributions by dust storms and dust devils are 61.3% and 38.7%, respectively. This study discovers a new area of dust emissions by dust devils, and provides a better explanation for the spatio-temporal distribution of AI in North Africa.

54 ENVIRONMENTAL SCIENCES↗

Structure of Epstein-Barr Virus Glycoprotein 42 Suggests a Mechanism for Triggering Receptor-Activated Virus Entry

Epstein-Barr virus requires glycoproteins gH/gL, gB, and gp42 to fuse its lipid envelope with B cells. Gp42 is a type II membrane protein consisting of a flexible N-terminal region, which binds gH/gL, and a C-terminal lectin-like domain that binds to the B-cell entry receptor human leukocyte antigen (HLA) class II. Gp42 triggers membrane fusion after HLA binding, a process that requires simultaneous binding to gH/gL and a functional hydrophobic pocket in the lectin domain adjacent to the HLA binding site. Here we present the structure of gp42 in its unbound form. Comparisons to the previously determined structure of a gp42:HLA complex reveals additional N-terminal residues forming part of the gH/gL binding site and structural changes in the receptor binding domain. Although the core of the lectin domain remains similar, significant shifts in two loops and an {alpha} helix bordering the essential hydrophobic pocket suggest a structural mechanism for triggering fusion.

59 BASIC BIOLOGICAL SCIENCES↗

Role of rat sodium/phosphate cotransporters in the cell membrane transport of arsenate

Inorganic arsenate (As{sup V}) is a common contaminant of underground water. Following oral exposure, it is assumed that As{sup V} is distributed and crosses cell membranes through inorganic phosphate (Pi) transporters. We have tested this hypothesis by studying the inhibition of rat Na/Pi cotransporters by As{sup V} in Xenopus laevis oocytes and in several rat tissues. The ubiquitously expressed type III Pi transporters (PiT-1 and PiT-2) showed a low affinity for As{sup V} (K{sub i} {approx} 3.8 mM), similar to the Pi transport system in aortic vascular smooth muscle cells (K{sub i} 1.5 mM). The type II renal isoforms, NaPi-IIa and NaPi-IIc, were also poorly inhibited by As{sup V} (K{sub i} {approx} 1 mM), similar to the Pi transport from kidney cortex brush-border membrane (BBM) vesicles. Conversely, the high-affinity intestinal transporter, NaPi-IIb, was very efficiently inhibited with a K{sub i} of 51 {mu}M, similar to the Pi transport from intestinal BBM vesicles. Taking into account the 1.1 mM Pi in blood and renal ultrafiltrate, and the nanomolar range of As{sup V} exposures, we have determined that the contribution by Na/Pi cotransporters to As{sup V} membrane transport is negligible, given that 10-15 mM As{sup V} would be necessary in these fluids to be significantly transported. Intestinal transport is an exception, because Pi competition is weak, thereby considering that its concentration in lumen mainly depends on low Pi levels from ingested fresh water, and because As{sup V} very efficiently inhibits Pi intestinal transport. Our data agree with current toxicokinetic knowledge, and they explain the asymmetric excretion of trivalent and pentavalent arsenic species into bile and urine.

60 APPLIED LIFE SCIENCES↗

Low doses of ochratoxin A upregulate the protein expression of organic anion transporters Oat1, Oat2, Oat3 and Oat5 in rat kidney cortex

Mycotoxin ochratoxin A (OTA) is nephrotoxic in various animal species. In rodents, OTA intoxication impairs various proximal tubule (PT) functions, including secretion of p-aminohippurate (PAH), possibly via affecting the renal organic anion (OA) transporters (Oat). However, an effect of OTA on the activity/expression of specific Oats in the mammalian kidney has not been reported. In this work, male rats were gavaged various doses of OTA every 2nd day for 10 days, and in their kidneys we studied: tubule integrity by microscopy, abundance of basolateral (rOat1, rOat3) and brush-border (rOat2, rOat5) rOat proteins by immunochemical methods, and expression of rOats mRNA by RT-PCR. The OTA treatment caused: a) dose-dependent damage of the cells in S3 segments of medullary rays, b) dual effect upon rOats in PT: low doses (50-250 {mu}g OTA/kg b.m.) upregulated the abundance of all rOats, while a high dose (500 {mu}g OTA/kg b.m.) downregulated the abundance of rOat1, and c) unchanged mRNA expression for all rOats at low OTA doses, and its downregulation at high OTA dose. Changes in the expression of renal Oats were associated with enhanced OTA accumulation in tissue and excretion in urine, whereas the indicators of oxidative stress either remained unchanged (malondialdehyde, glutathione, 8-hydroxydeoxyguanosine) or became deranged (microtubules). While OTA accumulation and downregulation of rOats in the kidney are consistent with the previously reported impaired renal PAH secretion in rodents intoxicated with high OTA doses, the post-transcriptional upregulation of Oats at low OTA doses may contribute to OTA accumulation and development of nephrotoxicity.

60 APPLIED LIFE SCIENCES↗

Standoff trace explosives vapor detection at meter distances

Vapor detection is a noncontact sampling method, which is a less invasive means of explosives screening than physical swiping. Explosive vapor detection is a challenge due to the low levels of vapors available for detection. This study demonstrates that the parts-per-quadrillion sensitivity of atmospheric flow tube-mass spectrometry (AFT-MS) combined with a high-volume air sampler enables standoff detection of trace explosives vapor at distances of centimeters to meters. Standoff detection of explosives vapor was possible both upstream and downstream of the vapor source relative to room air currents. RDX vapor from a saturated source was detected at up to 2.5 m. Vapors from RDX residue and nitroglycerin residue were detected at distances up to 0.5 m. The sampling can be optimized by accounting for air movement in the room or environment, which could further extend standoff detection distances. In conclusion, using AFT-MS with a high-volume sampler could also be effective for standoff vapor detection of drugs and additional chemical threats and could be useful for security screening applications such as at mail facilities, border crossings, and security checkpoints.

47 OTHER INSTRUMENTATION↗