Search NASA⌕ Search

SEARCH · Search NASA

Results for “closed loop”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

A Voltage Injection-Based Current Harmonics Suppression Strategy for Six-Phase PMSM With Nonsinusoidal Back EMF

This article presents a voltage injection-based current harmonic minimization method for wide bandgap device-based six-phase permanent magnet synchronous machine (PMSM) drives. The presence of low-order harmonics is common in the back EMF of PMSMs with low slot and high pole numbers. The back EMF harmonics generate low-order harmonic currents that increase torque ripples. Furthermore, zero-sequence current (ZSC) is also observed if all six phases are connected to a common neutral point. ZSC does not affect the torque ripple but reduces the system efficiency. A special technique is required to reduce ZSC for variable speed drives as direct ac component to synchronous reference frame (SRF) dc transformation is not possible for ZSC. In this article, a voltage injection-based current harmonics reduction method is proposed. The injected harmonic voltage coefficients are calculated from the harmonic estimations of back EMF and updated using closed-loop harmonic compensators to improve steady-state performance. For ZSC reduction, third harmonics power controller, and for 6n ± 1 (n = 1, 2,...) order harmonic current reduction, SRF current controllers are presented in this article. Furthermore, the current harmonics minimization method is experimentally verified using a GaN-based three-level active neutral point clamped inverter-driven six-phase PMSM.

42 ENGINEERING↗

Analysis and Control of a Three-Port Converter with High-Frequency AC Link for Hybrid Unmanned/Autonomous Aerial Vehicles

In this study, a three-port resonant converter with a high-frequency isolation link for hybrid unmanned/autonomous aerial vehicle (UAV/AAV) applications is analyzed. The rectified engine-generator set output supplies the first input ports while the other is connected to a battery energy storage system. Input ports consist of half-bridge high-frequency inverters, whereas output port utilizes a semi-bridgeless active rectifier. This rectifier is formed by replacing rectifier low-side diodes with active switching devices. A phase-shift duty-cycle control is implemented for switching signals to regulate the power share and flow between ports. The proposed control system implemented achieves zero voltage switching (ZVS), reduces switching losses, and minimum current flow optimization ensures regulation in a wide range of output power. Compared to the existing bidirectional pulse width modulation (PWM) converters, the proposed system decreases the number of power conversion stages and provides centralized control without needing communications between the ports. The proposed control technique operating in closed-loop control achieves the power flow between ports under various load conditions. Finally, theoretical analysis demonstrates the proposed converter’s viability and laboratory experimental validations at 500 W full power.

33 ADVANCED PROPULSION SYSTEMS↗

Fusion Intelligence: A Paradigm for Merging Natural and Artificial Intelligence

Here, this article presents fusion intelligence (FI), a bio-inspired paradigm that synergistically integrates the intrinsic capabilities of intelligent biological organisms with the advanced potential of artificial intelligence (AI)-driven systems. FI harnesses the unique intelligence, sensing, actuation, and mobility attributes of living organisms, such as honeybees, blending these with the sophisticated data-driven problem-solving functionalities of AI. By bridging the gap between natural intelligence (NI) and AI, FI can transform how humans interact with and harness the capabilities of both natural and artificial systems. This article presents the model of FI and its application to solve practical problems, discusses the challenges and future directions of FI research, emphasizing a generalized approach to solve complex problems, where AI can observe/control NI in a closed-loop system. We demonstrate the potential for FI to enhance the performance of an agricultural IoT system via a simulated case study, which achieves 50% improvement in the efficacy of insect pollination (entomophily).

47 OTHER INSTRUMENTATION↗

Robust Stabilization of Inverter-Based Resources Using Virtual Resistance-Based Control

This letter proposes a virtual resistance-based nonlinear control to stabilize and robustify the current layer of inverter-based resources, subject to the grid voltage disturbances, and the grid parameter uncertainties. A class of virtual resistances is proposed and analyzed using concepts from dissipative systems theory. Moreover, specific nonlinear virtual resistance-based controllers are derived, with their corresponding performance analytically bounded. Here, the theoretical and simulation results show that the proposed nonlinear virtual resistance-based controllers significantly reduce the L 2 gain of the closed-loop error system to grid voltage variation and parametric uncertainties. Significant improvements of the transient and steady-state current responses are also demonstrated over linear virtual resistance counterparts.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Robust Data-Driven Predictive Run-to-Run Control for Automated Serial Sectioning

This letter presents a one-step predictive run-to-run controller (R2R-MPC) for the automation of mechanical serial sectioning (MSS), a destructive material analysis process. To address the inherent uncertainty and disturbances in the MSS process, a robust closed-loop approach is presented. Here, the robust R2R-MPC models the uncertainty of the MSS process using a linear differential inclusion. As an analytical model of the MSS process is unavailable, the differential inclusion is identified from historical data. The R2R-MPC is posed as an optimization problem that computes incremental changes to the control input which minimize the worst-case material removal errors. This optimization-based controller is combined with a run-to-run controller to provide integral action that rejects constant disturbances and tracks constant reference removal rates. To demonstrate the efficacy of our robust R2R-MPC, we present simulation results which compare the presented controller with a conventional non-robust R2R.

42 ENGINEERING↗

Real-time Optimal Dispatch of Behind-the-Meter DERs for Secondary Frequency Regulation

Active distribution networks (ADNs) can provide grid services such as peak load shaving, loss reduction, VoltNar control, congestion management, and frequency regulation. The fast response of inverter-based distributed energy resources (DERs) and battery storage systems enables them to provide ramping support and frequency control. This paper proposes a real-time optimization approach for behind-the-meter DERs to participate in the secondary frequency regulation. The proposed approach determines optimal set-points of output power of DERs to respond to requests from system operators (SOs) in realtime to maintain the frequency of the system at the nominal value. To satisfy the real-time requirement for the secondary frequency control, the nonlinear AC power flow model is linearized considering power losses in the system to achieve both high computational speed and acceptable accuracy. The optimization problem is rerun in a closed loop manner until the mismatch between the requested power by the system operators and actual delivered power at the substation reaches an acceptable tolerance. Furthermore, the proposed approach is validated using modified versions of the IEEE 33-bus and IEEE 69-bus distribution systems. Although the contribution of a single distribution system in the frequency regulation may not be significant, stacked and coordinated contributions from several distribution systems can provide frequency regulation and other grid services at scale.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Model Based Validation of Intelligent Powertrain Strategies for Connected and Automated Vehicles

Systems incorporating Vehicle to Everything (V2X) and conventional cellular based communication in vehicles can significantly help improve energy consumption via a combination of intelligent powertrain control strategies, smarter routing algorithms and driving in such a way as to minimize fuel economy and the emission of carbon dioxide, known as "eco-driving." In projects led by the Southwest Research Institute (SwRI), large-scale traffic simulations are created to model real-world scenarios with dynamic behavior that is reactive to imposed changes. Coupled with high fidelity powertrain models, the closed loop framework enables research and development of such Connected and Automated Vehicle (CAV) enabled technologies at scale. This paper will discuss a traffic system simulation environment that was built based on the High Street urban corridor in Columbus, Ohio. Eco-driving strategies were tested at scale on a variety of powertrain platforms – internal combustion engines, hybrid electric and fully electric vehicles. Furthermore, the paper will focus on hybrid electric powertrain modeling along with details on how the powertrain model was leveraged to develop a sophisticated clustering scheme to help down-select speed traces from large scale simulation studies for validation on vehicle dynamometer. Nominal energy consumption improvement around 12% was observed with good match between simulation studies and vehicle testing.

33 ADVANCED PROPULSION SYSTEMS↗

Data-Conforming Data-Driven Control: Avoiding Premature Generalizations Beyond Data

Data-driven and adaptive control approaches face the problem of introducing sudden distributional shifts beyond the distribution of data encountered during learning. Therefore, they are prone to invalidating the very assumptions used in their own construction. This is due to the linearity of the underlying system, inherently assumed and formulated in most data-driven control approaches, which may falsely generalize the behavior of the system beyond the behavior experienced in the data. This article seeks to mitigate these problems by enforcing consistency of the newly designed closed-loop systems with data and slowing down any distributional shifts in the joint state-input space. This is achieved through incorporating affine regularization terms and linear matrix inequality constraints to data-driven approaches, resulting in convex semi-definite programs that can be efficiently solved by standard software packages. We discuss the optimality conditions of these programs and then conclude this article with a numerical example that further highlights the problem of premature generalization beyond data and shows the effectiveness of our proposed approaches in enhancing the safety of data-driven control methods.

97 MATHEMATICS AND COMPUTING↗

Shell-Based Support Structure for the 45 GHz ECR Ion Source MARS-D

Superconducting electron cyclotron resonance ion sources (ECRISs) using NbTi coils and optimized for 28 GHz resonant heating have been successfully operated for almost two decades. Moving to higher heating frequencies requires increased magnetic fields, but traditional racetrack-and-solenoid ECRIS structures are at their limit using NbTi. Rather than moving to a superconductor untested in this field, we report the Mixed Axial and Radial field System (MARS) being developed at Lawrence Berkeley National Laboratory employs a novel closed-loop-coil design that more efficiently utilizes conductor fields and will allow the use of NbTi in a next-generation, 45 GHz ECRIS. This article presents the design of the shell-based support structure central to the MARS-D magnet design, as well as structural analysis of its components and optimization of pre-load parameters that will guarantee its successful operation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design of a Structure for Assembly and Cooling the Magnet of the Next-Generation 45 GHz ECR Ion Source MARS-D

Here, the current Electron Cyclotron Resonance Ion Sources (ECRISs), constructed with Nb-Ti wires and the conventional racetrack-and-solenoid structure, have achieved operating frequencies up to 28 GHz and utilized about 90% of the critical current of the Nb-Ti wire. A Mixed Axial and Radial field System Demonstrator (MARS-D) is being developed at Lawrence Berkeley National Laboratory (LBNL). This system, which consists of an innovative hexagonal Closed-Loop Coil (CLC) and a set of solenoids, can generate higher magnetic fields (up to 150% ) while requiring only about 50% of the superconducting wire, enabling Nb-Ti wires to be used in the next-generation 45 GHz ECRIS. However, the assembly and cooling of such an efficient and compact magnet are particularly challenging due to the small radial gap between the CLC and solenoids, as well as the tight operating temperature margin. To address these challenges, a structure was developed that combines a three-section radially split solenoid mandrel with a series of shrink-fit reinforcement rings and cooling channels. This paper presents the detailed structure, manufacturing method, assembly procedure, impregnation method, mechanical Finite Element Analysis (FEA) comparison, and thermal FEA comparison.

ECR ion sources↗

Robust Optimal Control of Inverter-Based Resources Under Grid-Forming Operation

In this paper, we propose and solve a robust control problem for inverter-based resources under grid-forming operation to regulate the voltage and frequency. One major challenge is to mitigate the effect of unmeasurable load current disturbance, grid and load parametric uncertainties. Moreover, strong coupling between the state variables on both the AC and DC sides, as well as between the modulating control input and the frequency impose additional challenges. To address these challenges, first, a robust control problem is solved at the high level via transformation into an equivalent, but more tractable, optimal control problem. Then, in the middle layer a voltage control law is designed on the one side, and a frequency control law on the other side. Finally, an inverter filter current controller is designed to complete the controller design. Theoretical results are derived to provide stability guarantees for the resulting closed-loop system. Specifically, we show that the inverter current injection error is dissipative, the frequency error is semi-globally asymptotically stable, and the inverter terminal voltage error is globally asymptotically stable, all with provided sufficient conditions. Here, numerical simulation experiments are used to validate the theoretical claims. Furthermore, the developed controller is compared with existing work in literature to show the efficacy of the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Effective Current Balancing Method for Inverters With Paralleled Silicon Carbide Power Modules

Silicon carbide (SiC) MOSFET has many superior characteristics in high power applications. Paralleling the SiC devices is an effective approach to increase the current capacity of the system, which also leads to current sharing issues. In this article, both transient and steady-state current sharing issues are studied for the high-power grid-tied inverters with paralleled SiC modules with an effective current balancing strategy proposed to address both issues simultaneously. The steady-state imbalance current due to the parameter mismatch is suppressed by the self-inductance of power cables used for paralleling connection. With the elimination of steady-state imbalance current, the transient imbalance current sensing is much simplified and can be realized by using low-cost current sensors. With the sensed imbalance current, a closed-loop control approach is proposed to adjust the modulation reference signal for each module to mitigate the remaining transient imbalance current. Furthermore, the proposed method is straightforward to implement with enhanced compatibility and flexibility compared to existing methods. Experimental studies are performed using inverters with 2 and 4 power modules paralleled in each phase to demonstrate the effectiveness of the proposed method.

42 ENGINEERING↗

Bounded Universal Droop Control to Enable the Operation of Power Inverters Under Some Abnormal Conditions and Maintain Voltage and Frequency Within Predetermined Ranges

The universal droop control (UDC) can be applied to power inverters having an impedance angle between -pi/2 rad and pi/2 rad to achieve voltage and frequency regulation and accurate proportional power sharing without the need of knowing the type or value of impedance. However, there is an increasing need for voltage and frequency regulation within predetermined ranges even under some abnormal conditions, such as overloading, sensor faults, and large set-point changes, etc. In this paper, a bounded nonlinear dynamics is introduced into the UDC to ensure that the voltage and frequency can always stay within predetermined ranges under normal and some abnormal conditions, up to hardware limits when current protection needs to be triggered. As a result, the proposed controller can extend the operational range of power inverters in terms of voltage and frequency regulation to cover different scenarios. More importantly, the ranges for both voltage and frequency can be chosen independently from each other. Since the original structure of the UDC is kept in the proposed controller, the properties of the UDC, such as without the need of knowing the type or value of impedance, are well maintained. Furthermore, the closed-loop stability of the system is established via the Lyapunov method. Extensive simulation and experimental results are presented to validate the effectiveness of the proposed controller.

14 SOLAR ENERGY↗

Signal-Compensation-Based Adaptive PID Control for Fused Magnesia Smelting Processes

For fused magnesia smelting processes, the proportional-integral-derivative (PID) controller is difficult to regulate the smelting currents within desired ranges due to unexpected variations of the dynamics caused by material feeding operations. To solve this problem, we first proposed its dynamic model composed of a linear model and an uncertain nonlinear dynamic system that describes the unknown time-varying dynamics of nonlinearity and strong couplings among controlled variables. Then, using the accurately calculated value of the uncertain part at the previous sampling time instant and the tracking error that reflects the influence of its change rate, we developed a feedforward and a one-step optimal control to obtain two signal compensators to eliminate the impact of frequent variations of the uncertainties. For the compensators, we proposed a weight selection method to minimize the sum of the squared tracking error with ensured closed-loop stability. Based on the abovementioned modeling and control structure, we finally developed a novel adaptive PID controller augmented with signal compensators to control the whole process. Industrial applications have shown that the proposed method can always keep the tracking error and the control input within their targeted ranges, leading to a significantly reduced energy consumption per ton and increased fused magnesia production.

Wang, Weizhou↗

Optimal Control for X-Ray Mircroscopes

In this article, a systematic framework for designing the control for fine positioning (scanning) stages of X-ray microscopes is presented. This framework facilitates designs that simultaneously achieve specifications on positioning resolution and tracking bandwidth while guaranteeing robustness of the closed loop device to unmodeled uncertainties. We use robust optimal control techniques for modeling, quantifying design objectives and system-specific challenges, and designing the control laws. The control designs were implemented on a three degree of freedom piezoactuated flexure stages dedicated for fine positioning of X-ray optics. Experimental results demonstrate significant improvements in positioning performance of 134%, 150%, and 132% in tracking bandwidths along the lateral (X), vertical (Y), and beam (Z) directions, respectively, when compared to proportional-integral-derivative controller designs. This was achieved while keeping similar or better positioning resolution and robustness measures. Fast scanning for X-ray imaging was demonstrated in both the step scan and flyscan modes, where bandwidth was improved by over 450 times with flyscan compared to the step scan.

42 ENGINEERING↗

Decentralized Filtering Adaptive Neural Network Control for Uncertain Switched Interconnected Nonlinear Systems

This article presents a novel decentralized filtering adaptive neural network control framework for uncertain switched interconnected nonlinear systems. Each subsystem has its own decentralized controller based on the established decentralized state predictor. For each subsystem, the nonlinear uncertainties are approximated by a Gaussian radial basis function (GRBF) neural network incorporated with a piecewise constant adaptive law, where the adaptive law will update adaptive parameters from the error dynamics between the host system and the decentralized state predictor by discarding the unknowns, whereas a decentralized filtering control law is derived to cancel both local and mismatched uncertainties from other subsystems, as well as achieve the local objective tracking of the host system. The achievement of global objective depends on the achievement of local objective for each subsystem. The matched uncertainties are canceled directly by adopting their opposite in the control signal, whereas a dynamic inversion of the system is required to eliminate the effect of the mismatched uncertainties on the output. By exploiting the average dwell time principle, the error bounds between the real system and the virtual reference system, which defines the best performance that can be achieved by the closed-loop system, are derived. A numerical example is given to illustrate the effectiveness of the decentralized filtering adaptive neural network control architecture by comparing against the model reference adaptive control (MRAC).

Average dwell time, decentralized, filtering adapt↗

Framework for Analysis and Quantification of Wide-Area Control Resilience for Power Systems

Wide-area control helps damp the inter-area oscillations in modern power systems. However, compared to traditional local control, it is more vulnerable to cyber attacks due to its dependence on remote real-time-communicated measurements. In this paper, a formal mathematical framework for analyzing resilience of various wide-area controllers under adversarial scenarios is proposed. A novel resilience index based on the $\H_2$ norm of the post-attack closed-loop system is defined. Computation of such an index is, in general, challenging due to the combinatorial nature of the attack profiles and the bilinear nature of the problem. To address these difficulties, a gradient-based path-following-like solution is developed in this paper to solve a relaxed version of the original non-convex problem. Case studies on IEEE 39-bus system are performed to demonstrate the usage of the proposed framework.

Marinovici, Laurentiu D.↗