Search NASA⌕ Search

SEARCH · Search NASA

Results for “frequency response function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Dynamic Wind Loading on CSP Collectors Caused by Turbulent Wind Fluctuations: Insights from a 2-Year Field Campaign

Concentrating Solar Power (CSP) is a promising solar technology for electricity generation with thermal energy storage and with the additional benefit of industrial heat production. Wind loading on CSP collector structures, such as parabolic troughs or heliostats, is one of the primary drivers of their structural design costs. In particular, dynamic wind loading is a major source of uncertainty in the collector design process, which heavily relies on wind tunnel testing. In the field, the turbulent nature of the incoming wind creates fluctuating loads (support structure loads and resulting mirror deflections) on the collectors, with impacts on fatigue lifetime and optical performance. As is well known, wind tunnel tests cannot entirely reproduce the complex turbulent wind conditions typically observed at full-scale plants. To shed light on this topic, NREL initiated a field campaign at the operational Nevada Solar One (NSO) powerplant that uses parabolic troughs as solar collectors. The aim of the project is a detailed characterization of prevailing wind and turbulence conditions and resulting operational loads on parabolic troughs. We use the published 2-year dataset of high-resolution combined wind and structural loads measurements [1] to characterize the dynamic structural wind response. For quantifying dynamic wind loading, we apply the concept of admittance functions, which are spectral transfer functions that couple the turbulent wind to resulting structural loads (aerodynamic admittance), and to the structural response (mechanical admittance). In practice, aerodynamic admittance describes which turbulent eddy sizes are effective in creating structural loads. The mechanical admittance describes in which frequency ranges these loads are reinforced or dampened by the structure. While these functions are an established concept in civil engineering, their recent application to a single full-scale heliostat [2] proved their broader applicability to CSP collectors. Here, we present a characterization of admittance functions for full-scale parabolic trough collectors and show how wind characteristics (mean wind speed and direction, turbulent kinetic energy, turbulent length scales), the sun-tracking trough angle, and row position alter the admittance functions. Further, we study to which extent the admittance functions are universal for a specific trough geometry and how our findings compare to reported heliostat results. References [1] https://data.openei.org/submissions/5938. [2] Blume, K., Roger, M., and Pitz-Paal, R. 2023b. "Simplified analytical model to describe wind loads and wind-induced tracking deviations of heliostats." Solar Energy, 256, 96-109. https://doi.org/10.1016/j.solener.2023.03.055.

admittance functions↗

Shock loading predictions from application of indicial theory to shock-turbulence interactions

A sequence of steps that permits prediction of some of the characteristics of the pressure field beneath a fluctuating shock wave from knowledge of the oncoming turbulent boundary layer is presented. The theory first predicts the power spectrum and pdf of the position and velocity of the shock wave, which are then used to obtain the shock frequency distribution, and the pdf of the pressure field, as a function of position within the interaction region. To test the validity of the crucial assumption of linearity, the indicial response of a normal shock is calculated from numerical simulation. This indicial response, after being fit by a simple relaxation model, is used to predict the shock position and velocity spectra, along with the shock passage frequency distribution. The low frequency portion of the shock spectra, where most of the energy is concentrated, is satisfactorily predicted by this method.

Keefe, Laurence R.↗

Frequency response calibration of recess-mounted pressure transducers

A technique is described for measuring the frequency response of pressure transducers mounted inside a model, where a narrow pipette leads to an orifice at the surface. An acoustic driver is mounted to a small chamber which has an opening at the opposite end with an O-ring seal to place over the orifice. A 3.18 mm (1/8 inch) reference microphone is mounted to one side of the chamber. The acoustic driver receives an input of white noise, and the transducer and reference microphone outputs are compared to obtain the frequency response of the pressure transducer. Selected results are presented in the form of power spectra for both the transducer and the reference, as well as the amplitude variation and phase shift between the two signals as a function of frequency. The effect of pipette length and the use of this technique for identifying both blocked orifices and faulty transducers are described.

Marcolini, M. A.↗

Estimation of structural parameters from dynamic test data

Parameters for a lumped linear model approximating a distributed elastic structure are determined from dynamic test data comprised of several mode shapes and frequencies. Measurement errors, nonlinear response, and nonmeasurable quantities such as mode slope components are accommodated. Some mass and stiffness parameters may be known accurately, whereas the remainder are to be estimated. The method entails minimizing a quadratic function of the difference between corresponding modes and frequencies of the theoretical model and the test specimen. This technique was applied to some actual vibration test data, and the special techniques that are required to overcome convergence problems are described.

Hall, B. M.↗

Visual motor response of crewmen during a simulated 90 day space mission as measured by the critical task battery

In order to test various components of a regenerative life support system and to obtain data on the physiological and psychological effects of long-duration exposure to confinement in a space station atmosphere, four carefully screened young men were sealed in space station simulator for 90 days. A tracking test battery was administered during the above experiment. The battery included a clinical test (critical instability task) related to the subject's dynamic time delay, and a conventional steady tracking task, during which dynamic response (describing functions) and performance measures were obtained. Good correlation was noted between the clinical critical instability scores and more detailed tracking parameters such as dynamic time delay and gain-crossover frequency. The comprehensive data base on human operator tracking behavior obtained in this study demonstrate that sophisticated visual-motor response properties can be efficiently and reliably measured over extended periods of time.

Allen, R. W.↗

Current interrupt method for calculating the electrochemical impedance in a solid oxide electrolysis stack

Here, in this work the time domain response of Solid Oxide Electrolysis Cells (SOEC) to a current interruption was transformed into the frequency domain using a carrier function Laplace transform, which is fit to the experimental data using a MATLAB Complex Nonlinear Least Squares (CNLS) solver. The hardware implementation, consisting principally of a high-speed switch and a fast-logging Analog to Digital Converter (ADC), was assembled and tested using a calibration module to assess the accuracy, repeatability, and speed of acquisition of the prototype device as compared against a calibrated commercial impedance spectrometer. Additionally, the current interrupt device and commercial FRA were used to acquire the impedance spectra of a four cell SOEC stack with a large, 300 cm 2 , active cell area.

SOEC↗

Experiences at Langley Research Center in the application of optimization techniques to helicopter airframes for vibration reduction

A NASA/industry rotorcraft structural dynamics program known as Design Analysis Methods for VIBrationS (DAMVIBS) was initiated at Langley Research Center in 1984 with the objective of establishing the technology base needed by the industry for developing an advanced finite-element-based vibrations design analysis capability for airframe structures. As a part of the in-house activities contributing to that program, a study was undertaken to investigate the use of formal, nonlinear programming-based, numerical optimization techniques for airframe vibrations design work. Considerable progress has been made in connection with that study since its inception in 1985. This paper presents a unified summary of the experiences and results of that study. The formulation and solution of airframe optimization problems are discussed. Particular attention is given to describing the implementation of a new computational procedure based on MSC/NASTRAN and CONstrained function MINimization (CONMIN) in a computer program system called DYNOPT for the optimization of airframes subject to strength, frequency, dynamic response, and fatigue constraints. The results from the application of the DYNOPT program to the Bell AH-1G helicopter are presented and discussed.

Murthy, T. Sreekanta↗

Experiences at Langley Research Center in the application of optimization techniques to helicopter airframes for vibration reduction

A NASA/industry rotorcraft structural dynamics program known as Design Analysis Methods for VIBrationS (DAMVIBS) was initiated at Langley Research Center in 1984 with the objective of establishing the technology base needed by the industry for developing an advanced finite-element-based vibrations design analysis capability for airframe structures. As a part of the in-house activities contributing to that program, a study was undertaken to investigate the use of formal, nonlinear programming-based, numerical optimization techniques for airframe vibrations design work. Considerable progress has been made in connection with that study since its inception in 1985. This paper presents a unified summary of the experiences and results of that study. The formulation and solution of airframe optimization problems are discussed. Particular attention is given to describing the implementation of a new computational procedure based on MSC/NASTRAN and CONstrained function MINimization (CONMIN) in a computer program system called DYNOPT for the optimization of airframes subject to strength, frequency, dynamic response, and fatigue constraints. The results from the application of the DYNOPT program to the Bell AH-1G helicopter are presented and discussed.

Sreekanta Murthy, T.↗

Spatial-frequency response of the limb infrared monitor of the stratosphere

Measurements from the Limb Infrared Monitor of the stratosphere (LIMS) are presented and discussed. From the LIMS design model data, the modulation transfer function (MTF) was calculated for the optical system, the detector field mask, the electronics, and the overall system for each channel. The signal output performance of the instrument was predicted from the system MTF data and model input radiance data for each channel. The MTF measurements made on the flight sensor confirmed the analytical results.

Wilson, R. G.↗

A Sub-Hertz, Low-Frequency Vibration Isolation Platform

One of the major technical problems deep-space optical communication (DSOC) systems need to solve is the isolation of the optical terminal from vibrations produced by the spacecraft navigational control system and by the moving parts of onboard instruments. Even under these vibration perturbations, the DSOC transceivers (telescopes) need to be pointed l000 fs of times more accurately than an RF communication system (parabolic antennas). Mechanical resonators have been extensively used to provide vibration isolation for groundbased, airborne, and spaceborne payloads. The effectiveness of these isolation systems is determined mainly by the ability of designing a mechanical oscillator with the lowest possible resonant frequency. The Low-Frequency Vibration Isolation Platform (LFVIP), developed during this effort, aims to reduce the resonant frequency of the mechanical oscillators into the sub-Hertz region in order to maximize the passive isolation afforded by the 40 dB/decade roll-off response of the resonator. The LFVIP also provides tip/tilt functionality for acquisition and tracking of a beacon signal. An active control system is used for platform positioning and for dampening of the mechanical oscillator. The basic idea in the design of the isolation platform is to use a passive isolation strut with an approximately equal to 100-mHz resonance frequency. This will extend the isolation range to lower frequencies. The harmonic oscillator is a second-order lowpass filter for mechanical disturbances. The resonance quality depends on the dissipation mechanisms, which are mainly hysteretic because of the low resonant frequency and the absence of any viscous medium. The LFVIP system is configured using the well-established Stewart Platform, which consists of a top platform connected to a base with six extensible struts (see figure). The struts are attached to the base and to the platform via universal joints, which permit the extension and contraction of the struts. The struts ends are connected in pairs to the base and to the platform, forming an octahedron. The six struts provide the vibration isolation due to the properties of mechanical oscillators that behave as second-order lowpass filters for frequencies above the resonance. At high frequency, the ideal second-order low-pass filter response is spoiled by the distributed mass and the internal modes of membrane and of the platform with its payload.

Ortiz, Gerardo, G.↗

Application of the Convolution Formalism to the Ocean Tide Potential: Results from the Gravity and Recovery and Climate Experiment (GRACE)

A computationally efficient approach to reducing omission errors in ocean tide potential models is derived and evaluated using data from the Gravity Recovery and Climate Experiment (GRACE) mission. Ocean tide height models are usually explicitly available at a few frequencies, and a smooth unit response is assumed to infer the response across the tidal spectrum. The convolution formalism of Munk and Cartwright (1966) models this response function with a Fourier series. This allows the total ocean tide height, and therefore the total ocean tide potential, to be modeled as a weighted sum of past, present, and future values of the tide-generating potential. Previous applications of the convolution formalism have usually been limited to tide height models, but we extend it to ocean tide potential models. We use luni-solar ephemerides to derive the required tide-generating potential so that the complete spectrum of the ocean tide potential is efficiently represented. In contrast, the traditionally adopted harmonic model of the ocean tide potential requires the explicit sum of the contributions from individual tidal frequencies. It is therefore subject to omission errors from neglected frequencies and is computationally more intensive. Intersatellite range rate data from the GRACE mission are used to compare convolution and harmonic models of the ocean tide potential. The monthly range rate residual variance is smaller by 4-5%, and the daily residual variance is smaller by as much as 15% when using the convolution model than when using a harmonic model that is defined by twice the number of parameters.

models↗

Electric Field Induced Spectra of H sub 2 and D sub 2

The frequencies of four Q-branch lines of H2 and five Q-branch lines of D2 were measured as a function of density, and their shifts were observed to be in the linear region. The individual slopes and extrapolated zero density frequency of each line was determined. Hydrogen was measured for polarizability using the integrated intensity of the Q1(0) and S1(1), H2 absorption line. A highly automated technique for determining the response function of the spectrometer using digitally recorded data is presented. For the Q1(0) and Q1(1) lines of H2 the halfwidths were measured as a function of electric field intensity at constant pressure, and again at several densities and compared to previously measured widths. Technical and operational details of equipment built for this experiment, and for the five-meter Littrow spectrometer used, are described. Modifications of the spectrometer optics to accept the Stark cell are discussed.

Boyd, William Joseph↗

Hingeless rotor theory and experiment on vibration reduction by periodic variation of conventional controls

The reduction of the n per rev. pitch-, roll- and vertical vibrations of an n-bladed rotor by n per rev. sinusoidal variations of the collective and cyclic controls is investigated. The numerical results presented refer to a four-bladed, 7.5-foot model and are based on frequency response tests conducted under an Army-sponsored research program. The following subjects are treated: extraction of the rotor transfer functions (.073R hub flapping and model thrust versus servo valve command, amplitude and phase), calculation of servo commands (volts) required to compensate .073R hub flapping (3P and 5P) and model thrust (4P), evaluation of the effect of the vibratory control inputs on blade loads, and theoretical prediction of the root flapbending moments generated by 0 to 5P perturbations of the feathering angle and rotor angle of attack. Five operating conditions are investigated covering advance ratios from approximately 0.2 to 0.85. The feasibility of vibration reduction by periodic variation on conventional controls is evaluated.

Sissingh, G. J.↗

The deep lunar electrical conductivity profile - Structural and thermal inferences

Simultaneous lunar surface and orbital magnetometer records are reexamined, to ascertain intervals which may be suitable for measuring lunar inductive response in the solar wind and terrestrial magnetosheath. Power spectral estimates of the response tangent to the lunar surface, defined in terms of transfer and gain functions, are obtained for the 0.0001-0.01 Hz frequency range. The maximum consistency of estimates from different time intervals is found when the initial analysis is limited to the tangential direction of maximum incident power, or that direction in which the ratio of signal to background noise is greatest. Spherically symmetric plasma confinement theory is used in the interpretation of transfer function data, by way of forward model calculations, under the assumption of continuous electrical conductivity increase with depth. Results are presented for internal electrical conductivity profile, metallic core radius, and selenotherm limits.

Hood, L. L.↗

Optical Design and Signal Processing for Edge Detection

Properly combining optical design with 3-by-3 element mask reduces number of required computations by factor of as much as 100. Spatial and spatial-frequency responses obtained in system of combination of optical design and signal-processing algorithm. Closely approximate difference-of-Gaussian-function response.

Huck, Friedrich O.↗

The dynamic-response characteristics of a 35 degree swept-wing airplane as determined from flight measurements

The longitudinal and lateral-directional dynamic-response characteristics of a 35 degree swept-wing fighter-type airplane determined from flight measurements are presented and compared with predictions based on theoretical studies and wind-tunnel data. Flights were made at an altitude of 35,000 feet covering the Mach number range of 0.50 to 1.04. A limited amount of lateral-directional data were also obtained at 10,000 feet. The flight consisted essentially of recording transient responses to pilot-applied pulsed motions of each of the three primary control surfaces. These transient data were converted into frequency-response form by means of the Fourier transformation and compared with predicted responses calculated from the basic equations. Experimentally determined transfer functions were used for the evaluation of the stability derivatives that have the greatest effect on the dynamic response of the airplane. The values of these derivatives, in most cases, agreed favorably with predictions over the Mach number range of the test.

Triplett, William C↗

Ascent Aborts 2 Flight, Reconstruction of Structural Dynamics (Couple Loads Transients)

- This work describes the elements of AA2 post-flight data analysis, couple loads analysis, and comparisons of the flight data with the results of analytical methods transiently. - The measured transient responses ranged from rigid body frequencies (zero Hz) to 150 Hz. - The analytical methods consisted of defining and determining all forcing functions, i.e., buffet, aerodynamics, thrusts from the abort motor and the carrier lunch vehicle motor, and the initial conditions at pre-separation. - Mathematical models representing the mechanics of Orion abort is relatively complex because 1) two motors (carrier’s and LAS’s) are operating at the same time at pre-separation, and 2) the separation occurs in atmosphere. - Other challenges consist of determining the aerodynamics with plume-on condition at every millisecond of the flight ranging from transonic to supersonic (i.e., Mach 1.1 to Mach 1.6), and defining the mechanics of separation of LAS from the launch vehicle.

Launch Vehicle↗

Performance Evaluation of Multi-Vendor Grid-Forming Inverters for Grid-Connected Operation Through Hardware Experimentation

This paper presents the functional performance evaluation tests of multiple (three) commercial grid-forming (GFM) inverters when they operate in parallel with the grid through hardware experiments. The goal of these tests is to explore and benchmark the GFM inverters' functionalities and dynamic response when they are operated in parallel with power grids. Both steady-state (changing the inverter's frequency and voltage droop) and transient (adding step changes to grid's frequency/voltage) tests are performed for each GFM inverter with the same testing circuit and testing protocol. The key findings are summarized as follows: 1) The GFM inverters can be dispatched through frequency and voltage droop intercepts to output the target power; and 1) the GFM inverters automatically respond to system frequency and voltage events to output the needed power; 3) all the GFM inviters shows stability issues when absorbing reactive power from the grid.

frequency droop↗