Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Design of a Cryogenic Assembly for Comparing Qubit Infrared Packaging Inefficiencies

It is well known that everything emits infrared (IR) light in the form of thermal radiation. IR radiation on superconducting qubits carries enough energy to cause decoherence and so-called “quasiparticle poisoning.” Therefore, proper IR shielding is needed to keep the qubit in a high coherence state. However, trying to extract IR-specific information from a qubit is difficult, so a microwave kinetic inductance detector (MKID) can be used instead. We show that the IR shielding inefficiencies of MKID packages can only be compared with other packaging inefficiencies. We create a cryogenic assembly CAD design, consisting of magnetic shield cans, a copper mounting plate and mounts, and an MKID enclosure, which thermalizes the assembly to dilution refrigerator temperatures. Phase 1 of this design involves using a narrowband IR laser source to test the IR shielding of packaging at the laser’s wavelength. When the best IR shielding packaging is determined, the superconducting qubit can replace the MKID, allowing the qubit to avoid decoherence due to IR radiation and boost its performance and coherence lifetime.

Mailliard, Robert J. [Fermilab] (ORCID:00090000277↗

Purification Procedures for Single-Wall Carbon Nanotubes

This report summarizes the comparison of a variety of procedures used to purify carbon nanotubes. Carbon nanotube material is produced by the arc process and laser oven process. Most of the procedures are tested using laser-grown, single-wall nanotube (SWNT) material. The material is characterized at each step of the purification procedures by using different techniques including scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), transmission electron microscopy (TEM), Raman, X-ray diffractometry (XRD), thermogravimetric analysis (TGA), nuclear magnetic resonance (NMR), and high-performance liquid chromatography (HPLC). The identified impurities are amorphous and graphitic carbon, catalyst particle aggregates, fullerenes, and hydrocarbons. Solvent extraction and low-temperature annealing are used to reduce the amount of volatile hydrocarbons and dissolve fullerenes. Metal catalysts and amorphous as well as graphitic carbon are oxidized by reflux in acids including HCl, HNO3 and HF and other oxidizers such as H2O2. High-temperature annealing in vacuum and in inert atmosphere helps to improve the quality of SWNTs by increasing crystallinity and reducing intercalation.

Gorelik, Olga P.↗

Design of a Cryogenic Assembly for Comparing Qubit Infrared Packaging Inefficiencies

It is well known that everything emits infrared (IR) light in the form of thermal radiation. IR radiation on superconducting qubits carries enough energy to cause decoherence and so-called “quasiparticle poisoning.” Therefore, proper IR shielding is needed to keep the qubit in a high-coherence state. However, trying to extract IR-specific information from a qubit is difficult, so a microwave kinetic inductance detector (MKID) can be used instead. We show that the IR shielding inefficiencies of MKID packages can only be compared with other packaging inefficiencies. We create a cryogenic assembly CAD design, consisting of magnetic shield cans, a copper mounting plate and mounts, and an MKID enclosure, which thermalizes the assembly to dilution refrigerator temperatures. Phase 1 of this design involves using a narrowband IR laser source to test the IR shielding of packaging at the laser’s wavelength. When the best IR shielding packaging is determined, the superconducting qubit can replace the MKID, allowing the qubit to avoid decoherence due to IR radiation and boost its performance and coherence lifetime.

Mailliard, Robert J. [Fermilab] (ORCID:00090000277↗

CMS Outer Tracker Module QA

It is well known that everything emits infrared (IR) light in the form of thermal radiation. IR radiation on superconducting qubits carries enough energy to cause decoherence and so-called “quasiparticle poisoning.” Therefore, proper IR shielding is needed to keep the qubit in a high-coherence state. However, trying to extract IR-specific information from a qubit is difficult, so a microwave kinetic inductance detector (MKID) can be used instead. We show that the IR shielding inefficiencies of MKID packages can only be compared with other packaging inefficiencies. We create a cryogenic assembly CAD design, consisting of magnetic shield cans, a copper mounting plate and mounts, and an MKID enclosure, which thermalizes the assembly to dilution refrigerator temperatures. Phase 1 of this design involves using a narrowband IR laser source to test the IR shielding of packaging at the laser’s wavelength. When the best IR shielding packaging is determined, the superconducting qubit can replace the MKID, allowing the qubit to avoid decoherence due to IR radiation and boost its performance and coherence lifetime.

Hobbeheydar, Samuel [Carnegie Mellon U. (main); Fe↗

Development and Preliminary Tests of an Open-Path Airborne Diode Laser Absorption Instrument for Carbon Dioxide

Carbon dioxide (CO2) is well known for its importance as an atmospheric greenhouse gas, with many sources and sinks around the globe. Understanding the fluxes of carbon into and out of the atmosphere is a complex and daunting challenge. One tool applied by scientists to measure the vertical flux of CO2 near the surface uses the eddy covariance technique, most often from towers but also from aircraft flying specific patterns over the study area. In this technique, variations of constituents of interest are correlated with fluctuations in the local vertical wind velocity. Measurement requirements are stringent, particularly with regard to precision, sensitivity to small changes, and temporal sampling rate. In addition, many aircraft have limited payload capability, so instrument size, weight, and power consumption are also important considerations. We report on the development and preliminary application of an airborne sensor for the measurement of atmospheric CO2. The instrument, modeled on the successful DLH (Diode Laser Hygrometer) series of instruments, has been tested in the laboratory and on the NASA DC-8 aircraft. Performance parameters such as accuracy, precision, sensitivity, specificity, and temporal response are discussed in the context of typical atmospheric variability and suitability for flux measurement applications. On-aircraft, in-flight data have been obtained and are discussed as well. Performance of the instrument has been promising, and continued flight testing is planned during 2016.

Diskin, Glenn S.↗

Strong interplay between superluminosity and radiation friction during direct laser acceleration

Using a test-particle model, we examine direct laser acceleration of electrons within a magnetic filament that has been shown to form inside a laser-irradiated plasma. We focus on ultra-high intensity interactions where the force of radiation friction caused by electron emission of electromagnetic radiation must be taken into account. It is shown that even relatively weak superluminosity of laser wave fronts—the feature that has been previously neglected—qualitatively changes the electron dynamics, leading to a so-called attractor effect. As a result of this effect, electrons with various initial energies reach roughly the same maximum energy and emit roughly the same power in the form of x-rays and gamma-rays. Our analysis implies that the primary cause of the superluminosity is the laser-heated plasma. The discovered strong interplay between superluminosity and radiation friction is of direct relevance to laser-plasma interactions at high-intensity multi-PW laser facilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phillips CO-oxidation catalyts for long-lived CO2 lasers: Activity and initial characterization studies

Four different catalysts have been developed specifically for use in sealed carbon dioxide lasers. The catalysts have been designed to be low dusting, stable to shock and vibration, have high activity at low temperatures and have long active lifetimes. Measured global CO oxidation rates range from 1.4 to 2.2 cc CO converted per minute per gram of catalyst at ambient temperature. The catalysts also retain substantial activity at temperatures as low as -35 C. The Phillips laser catalysts are prepared in a variety of different shapes to meet the different pressure drop and gas flow profiles present in the many different styles of lasers. Each catalyst has been tested in sealed TEA lasers and has been shown to substantially increase the sealed life of the laser. Activity measurements made on the precious metal catalysts which were prepared with and without activity promoters showed that the promoter materials increase catalyst CO oxidation activity at least an order of magnitude at ambient temperature. Initial studies using H2 and CO chemisorption, X ray diffraction (XRD) and X ray photoelectron spectroscopy (XPS) have shown that the activity promoters do not significantly affect the precious metal crystallite size or the electronic structure around the precious metal. In addition, the formation or lack of formation of solid solutions between the precious metal and promoters has also been shown not to affect the activity of the promoted catalyst.

Kolts, J. H.↗

On-chip spectroscopic sensors with optical fringe suppression

An on-chip spectroscopic sensor includes a tunable diode laser. A laser driver for drives the tunable diode laser. An analyte test cavity receives a chemical sample and exposes the received chemical sample to light from the tunable diode laser. An optical detector detects light emerging from the analyte test cavity as a result of the laser exposure. A spectral analyzer determines a spectrum of the emerging light, matches and removes one or more known optical fringe patterns from the determined spectrum, and determines a composition or concentration of the chemical sample from the optical fringe pattern-removed spectrum.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On-chip spectroscopic sensors with optical fringe suppression

An on-chip spectroscopic sensor includes a tunable diode laser. A laser driver for drives the tunable diode laser. An analyte test cavity receives a chemical sample and exposes the received chemical sample to light from the tunable diode laser. An optical detector detects light emerging from the analyte test cavity as a result of the laser exposure. A spectral analyzer determines a spectrum of the emerging light, matches and removes one or more known optical fringe patterns from the determined spectrum, and determines a composition or concentration of the chemical sample from the optical fringe pattern-removed spectrum.

Green, William↗

Rapid in situ nutrient element distribution in plants and soils using laser-induced breakdown spectroscopy ($\mathrm{LIBS}$)

The aim of this study is to develop and test the applicability of a rapid in situ plant chemistry profiling technique to determine elemental composition of small-volume plant and soil samples obtained from a woody bioenergy crop species, Populus trichocarpa. Expanding the research tools available to characterize the nutrient element correlations among plant tissue types and soil depths is a critical need in the path of understanding productivity and adaptation of plants to variations in external abiotic and biotic factors and developing sustainable perennial bioenergy crops that are co-optimized for biomass valorization aboveground and carbon sequestration belowground. Several plant root, stem, and soil samples were tested using laser-induced breakdown spectroscopy (LIBS) to evaluate the presence and distribution of nutrient elements. Samples were tested as collected and after being dried and cross sectioned to evaluate the effectiveness of using LIBS for in situ analysis on plant samples. The collected LIBS spectra show the elemental peaks were the same in both the as collected and prepared samples for roots and stems. Qualitative amounts of elements such as H, C, N, O, Li, Na, Mg, K, Ca, Fe, Al, and Si were able to be identified rapidly in raw samples. Here in this report we demonstrate suitability of LIBS in obtaining rapid, in situ, elemental distribution in plant and soil samples, utilizing only small sample volumes and minimal sample preparation. This demonstration opens up a new rapid phenotyping avenue necessary to fill the asymmetrical knowledge gaps in belowground performance of plant systems.

59 BASIC BIOLOGICAL SCIENCES↗

Slab-geometry Nd:glass laser performance studies

It is noted that slab-geometry solid-state lasers potentially provide significant performance improvements relative to conventional rod-geometry lasers. Experimental measurements that use an Nd:glass test-bed slab laser are presented. A comparison is made between the results and computer-model predictions of the slab-geometry approach. The computer model calculates and displays the temperature and stress fields in the slab, and on the basis of these predicts birefringence and index-of-refraction distributions. The effect that these distributions have on optical propagation is determined in a polarization-sensitive ray-tracing section of the model. Calculations are also made of stress-induced surface curvature and the resulting focusing effects. The measurements are found to be in good agreement with the computer-model predictions. It is concluded that the slab configuration offers significant laser-performance advantages in comparison with the traditional rod-laser geometry.

Eggleston, J. M.↗

Life test results for an ensemble of CO2 lasers

The effects of cathode material, cathode operating temperature, anode configuration, window materials, and hydrogen additives on laser lifetime are determined. Internally oxidized copper and silber-copper alloy cathodes were tested. The cathode operating temperature was raised in some tubes through the use of thermal insulation. Lasers incorporating thermally insulated silver copper oxide cathodes clearly yielded the longest lifetimes-typically in excess of 22,000 hours. The use of platinum sheet versus platinum pin anodes had no observable effect on laser lifetime. Similarly, the choice of germanium, cadmium telluride, or zinc selenide as the optical window material appears to have no impact on lifetime.

Peruso, C. J.↗

A laser velocimeter system for small radial turbomachinery

The paper describes the design and test of a laser Doppler velocimeter (LDV) to map the velocity fields in small high-speed turbomachinery. This instrument is presently being used as a diagnostic tool for the study of the basic fluid dynamics of the inducer, impeller and the diffuser regions of high-pressure-ratio small centrifugal compressors. The LDV instrumentation has been optimized to permit measurement of instantaneous velocities up to approximately 500 m/s within a rotating impeller. It is shown that LDV can make nondisturbing gas velocity measurements and surmount the difficulties found in applying other types of aerodynamic instrumentation, e.g., hot-wire anemometers, to this measurement problem.

Runstadler, P. W., Jr.↗

Laser-beam power for lunar and space applications

GaAlAs/GaAs heteroface converters were experimentally tested using DIRECT laser irradiation of photovoltaic devices. It is concluded that the two types of converters are promising for converting diode-laser radiation to electricity. Conversion efficiency as high as 45 and 34.2 percent was obtained using GaAS and Si converters of the SSF type, respectively.

Walker, Gilbert H.↗

Laser diagnostics for microgravity droplet studies

An instrument has been designed, built, and tested for performing laser diagnostic measurements of droplet combustion in low-gravity-flight aircraft. Nonintrusive measurements are of particular importance for droplet combustion (the simplest example of non-premixed combustion) and transport in microgravity environments, where physical contact would introduce an unacceptable level of perturbations. The resolution of these diagnostics can also isolate transport to length scales much smaller than the droplet diameter. These techniques can be configured to instantaneously map an entire flow field in two and three dimensions, providing either qualitative or quantitative information on the distribution of a desired scalar or vector quantity. Detailing the gas-phase flow field and position of the flame front can be achieved using planar laser-induced fluorescence (PLIF) of OH or another flame front marker. An alternative approach is to obtain LIF from a diagnostic seed included in the liquid phase fuel; it would be consumed at the flame front. The main advantage to this approach is that it is easier to choose the wavelength of the molecular absorption which coincides with convenient laser wavelengths rather than finding lasers which can be configured to access OH. Our present method uses a nitrogen-pumped dye laser tuned to a sodium absorption and addition of small concentrations of NaCl to the fuel. Particle image velocimetry (PIV) is a laser-based technique which has recently had its practicality greatly enhanced by the development of high-resolution CCD cameras and the increase in speed and capacity of computer systems. With this technique, a seeded flow is illuminated with a double-pulsed laser sheet to generate a double exposure image on a film or CCD camera. Computer analysis of the image is used to determine the particle velocity vectors and, thus, the gas velocity within the plane of the laser sheet. Our current experiment uses PIV for measuring relative droplet gas-phase velocities in a parabolic flight environment. The results show successful application of PLIF relative to luminosity and radical emission near 308 nm. PIV results are less successful due to gas thermal expansion deflecting the seed particles away from the measurement volume. PIV is applicable for measurements in the absence of combustion.

Winter, Michael↗

Designing transonic wind-tunnel test sections for flow diagnostics and laser velocimeter applications

The design, fabrication, and validation of the Basic Aerodynamic Facility (BARF), developed for the direct comparison of three-dimensional laser velocimetry (LV) and hot-wire techniques at transonic speeds, are discussed. To accommodate the installation of the three-dimensional orthogonal LV system in the BARF, the transonic slots were redesigned to house windows, and the test section mounting was redesigned to facilitate LV transversing. Two-dimensional and three-dimensional code validation tests of the LV test section showed uniform mean flow through the test section to sonic speeds, and fluctuating pressure measurements at subsonic speeds which are consistent with facilities with good flow quality.

Jones, G. S.↗

Post-Flight Test Results of Acousto-Optic Modulator Devices Subjected to Space Exposure

The objective of the Materials International Space Station Experiment (MISSE) is to study the performance of novel materials when subjected to the synergistic effects of the harsh space environment for several months. MISSE missions provide an opportunity for developing space qualifiable materials. Several laser and lidar components were sent by NASA Langley Research Center (LaRC) as a part of the MISSE 7 mission. The MISSE 7 module was transported to the international space station (ISS) via STS 129 mission that was launched on Nov 16, 2009. Later, the MISSE 7 module was brought back to the earth via the STS 134 that landed on June 1, 2011. The MISSE 7 module that was subjected to exposure in a space environment for more than one and a half years included fiber laser, solid-state laser gain materials, detectors, and semiconductor laser diode. Performance testing of these components is now progressing. In this paper, the results of performance testing of a laser diode module sent by NASA Langley Research Center on MISSE 7 mission will be discussed. This paper will present the comparison of pre-flight and post-flight performance of two different COTS acousto-optic modulator (AOM) devices. Post-flight measurements indicate that these two devices did not undergo any significant performance degradation.

Prasad, Narasimha S.↗