Search NASASearch

SEARCH · Search NASA

Results for “nanoparticles, lithium-ion battery, electrolyte, capacity, coating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

430 records · Page 24

Light–Material Interactions Using Laser and Flash Sources for Energy Conversion and Storage Applications

Abstract This review provides a comprehensive overview of the progress in light–material interactions (LMIs), focusing on lasers and flash lights for energy conversion and storage applications. We discuss intricate LMI parameters such as light sources, interaction time, and fluence to elucidate their importance in material processing. In addition, this study covers various light-induced photothermal and photochemical processes ranging from melting, crystallization, and ablation to doping and synthesis, which are essential for developing energy materials and devices. Finally, we present extensive energy conversion and storage applications demonstrated by LMI technologies, including energy harvesters, sensors, capacitors, and batteries. Despite the several challenges associated with LMIs, such as complex mechanisms, and high-degrees of freedom, we believe that substantial contributions and potential for the commercialization of future energy systems can be achieved by advancing optical technologies through comprehensive academic research and multidisciplinary collaborations.

Materials Science

Thermal Reservoir Networks for Modularly Expandable Thermal Microgrids

The Department of Defense (DoD) faces the substantial challenge of cost-effectively retrofitting one to two installations per month, each comprising approximately 1,000 buildings, to improve resilience, reduce energy consumption, and enhance energy supply security. Achieving these objectives requires optimal system selection and effective risk mitigation during system integration. To address this need, we introduce Platform-Based Design (PBD), a structured, hierarchical methodology adapted from other industrial sectors to the domain of energy system retrofits. We demonstrate the effectiveness of PBD through a techno-economic feasibility study comparing geothermal-coupled thermal energy networks (TENs) with conventional energy systems for heating, cooling, and powering 17 buildings at Joint Base Andrews (JBA) in Maryland. Our analysis illustrates that the PBD approach enables rigorous, data-driven, sequential decision making, resulting in a family of Pareto-optimal systems, among which the TEN emerged as the most promising solution. The selected TEN design integrates geothermal borefields, heat recovery heat pumps, photovoltaic (PV) arrays, and battery storage. Compared to the baseline system – gas heating combined with air-source chillers – the proposed TEN reduces annual imported energy by 74% and peak electricity demand by 45%, achieves a levelized cost of energy of $\$0.210$/kWh, and substantially enhances resilience. Life-cycle costs increase by approximately 6%, and initial investment costs are about 2.5 times higher than the baseline. However, if central plant infrastructure, district loops, and utility-scale PV and battery systems are privately funded and operated, the initial investment would fall below the baseline system cost. Critical to achieving these significant performance improvements were detailed nonlinear dynamic simulations coupling geothermal heat transfer, energy system operation, and realistic feedback control logic. These simulations identified essential design modifications and control strategy refinements that substantially reduced energy use, peak demand, and compressor shortcycling, thereby improving durability and reliability—issues that would have been significantly more expensive to resolve during operation. Additionally, the verification step highlighted sensitivities to key design parameters that could reduce initial investment by approximately $\$2$ million and reduce annual life-cycle costs more than $\$300,000$. We recommend adopting the PBD methodology for future feasibility studies and TEN pilot projects to gain valuable operational experience. Furthermore, we recommend that DoD invest in transferring and scaling the PBD methodology to other installations. This entails developing standardized computational frameworks and component libraries as well as training industry in conducting PBD. Such investments would enable rapid, robust, reliable, and cost-effective retrofits, supporting DoD’s ambitious energy system modernization goals.

Wetter, Michael [Lawrence Berkeley National Labora

Smart Charging of Fleet and Personal Electric Vehicles through Joint Vehicle-to-Grid Optimization

As electric vehicle (EV) adoption accelerates, vehicle-to-grid (V2G) strategies offer advantages over unmanaged charging (V0G) by enhancing grid stability, reducing fleet operation costs, and supporting integration of variable generation resources. This research develops a day-ahead optimization framework linked with agent-based simulations to evaluate coordinated V2G participation by fleet and personal EVs under 5 energy-pricing settings in Austin, Texas. Three scenarios (V0G, fleet-only V2G, and joint-V2G) are examined, considering real-time price and grid profiles, health-damage costs, and operational constraints for both fleet and personal EVs. Results show how V2G scenarios shift fleet EV charging to mid-day while enabling strategic battery-discharge during evening peaks, mitigating grid stress and lowering EV energy costs. V2G delivers close to 80% energy-cost savings for a 2000-EV fleet in Austin on grid-stressed days, with 55% lower charging pollutant outputs. Joint-V2G amplifies system-level benefits by complementing fleet discharge, but smart-charging equipment costs can offset those benefits.

Electric vehicle

Maximizing Free Energy Gain

Maximizing the amount of work harvested from an environment is important for a wide variety of biological and technological processes, from energy-harvesting processes such as photosynthesis to energy storage systems such as fuels and batteries. Here, we consider the maximization of free energy—and by extension, the maximum extractable work—that can be gained by a classical or quantum system that undergoes driving by its environment. We consider how the free energy gain depends on the initial state of the system while also accounting for the cost of preparing the system. We provide simple necessary and sufficient conditions for increasing the gain of free energy by varying the initial state. We also derive simple formulae that relate the free energy gained using the optimal initial state rather than another suboptimal initial state. Finally, we demonstrate that the problem of finding the optimal initial state may have two distinct regimes, one easy and one difficult, depending on the temperatures used for preparation and work extraction. We illustrate our results on a simple model of an information engine.

Physics

Enhanced Hydrogen Evolution Catalysis of Pentlandite due to the Increases in Coordination Number and Sulfur Vacancy during Cubic‐Hexagonal Phase Transition

Abstract The search for new phases is an important direction in materials science. The phase transition of sulfides results in significant changes in catalytic performance, such as MoS 2 and WS 2 . Cubic pentlandite [cPn, (Fe, Ni) 9 S 8 ] can be a functional material in batteries, solar cells, and catalytic fields. However, no report about the material properties of other phases of pentlandite exists. In this study, the unit‐cell parameters of a new phase of pentlandite, sulfur‐vacancy enriched hexagonal pentlandite (hPn), and the phase boundary between cPn and hPn are determined for the first time. Compared to cPn, the hPn shows a high coordination number, more sulfur vacancies, and high conductivity, which result in significantly higher hydrogen evolution performance of hPn than that of cPn and make the non‐nano rock catalyst hPn superior to other most known nanosulfide catalysts. The increase of sulfur vacancies during phase transition provides a new approach to designing functional materials.

Chemistry

Project Development of an Electrochemical Denitration and Caustic Generation System for HLW Pretreatment at Hanford - 26350

An engineering-scale electrochemical processing skid is proposed to perform the denitration of Hanford tank waste, which would help to mitigate a key process concern with the direct feed processing of the Hanford Tank Waste Treatment and Immobilization Plant (WTP). The reduction of nitrates and organic compounds in the waste feed will directly reduce hazardous NOx and ammonia gases generated during the vitrification process, which in turn will aid in addressing potential regulatory and safety challenges associated with processing large volumes of tank waste. This paper highlights the past legacy work, project layout, accomplishments from Phase 1 and research and development envisioned for Phase 2. An innovative electrochemical denitration and caustic generation (EDCGe) process was demonstrated for the pretreatment of tank waste at the Savannah River Site (SRS) in the early 2000s. The denitration electrolyzer, off-gas abatement system, and caustic generator electrolyzer are being developed with the intent that the denitration electrolyzer will convert nitrate and nitrite anions to nitrogen gas while also yielding other gaseous byproducts, which may include N2O, NH3, VOCs, and H2. The gaseous byproducts will be managed via a tandem off-gas catalyst-bed treatment system. The caustic generation electrolyzer will recycle NaOH from the feed to produce a clean caustic stream for use within the batching tanks at Hanford, aiding in the preparation of waste for WTP. The reduction in hazardous emissions and improved waste treatment processes provides a robust solution for nuclear waste management, contributing to environmental safety and regulatory compliance. The EDCGe technology is being adapted, modified, and updated for the preparation of the Direct Feed-High Level Waste (DF-HLW) flowsheet at Hanford. Phase 1 demonstrated a bench-scale proof-of-concept for reactions involving the denitration electrolyzer and gas phase abatement of ammonia. The electrochemical technology is drawing on the scientific outcomes that were reported in the legacy work. The results from Phase 1 demonstrated the viability of the EDCGe system in reducing the nitrogen species of simple non-radioactive waste simulants. Commercially available alloys used as electrode materials and membranes are being studied for the denitration and caustic generation electrolyzers. The continuation of this project holds promise for broader applications, such as energy-efficient ammonia production, and contributes significant advancements in nuclear waste management. Additional material discovery has been investigated into ceramic Na super ion conductive (NaSICON) materials and off-gas abatement catalyst discovery. NaSICON is of interest for selective transport of Na within the electrolyzers to make a clean caustic stream. Future integration and optimization efforts, informed by Phase 1 results and ongoing research, will continue to drive advancements in nuclear waste management technology. The technology developed for the EDCGe treatment of tank waste will also have broader potential to inform other fields, such as energy-efficient ammonia production, as well as ammonia abatement catalysis through the lessons learned in electrochemical nitrate reduction. The applications and benefits of this research extend beyond Hanford and the Savannah River Site, supported by a collaborative team of scientists and engineers from national labs, academia, and industry, ensuring a comprehensive approach to solving complex waste treatment challenges. The team is leveraging advanced electrochemical technologies, machine learning, novel catalysts tailored for gaseous nitrogen species, and cutting-edge reactor systems to enhance the process efficiency and effectiveness of the denitration process.

Rodene, Dylan [Savannah River National Laboratory

Tradeoffs and Synergies in Tropical Forest Root Traits and Dynamics for Nutrient and Water Acquisition: Field and Modeling Advances

Vegetation processes are fundamentally limited by nutrient and water availability, the uptake of which is mediated by plant roots in terrestrial ecosystems. While tropical forests play a central role in global water, carbon, and nutrient cycling, we know very little about tradeoffs and synergies in root traits that respond to resource scarcity. Tropical trees face a unique set of resource limitations, with rock-derived nutrients and moisture seasonality governing many ecosystem functions, and nutrient versus water availability often separated spatially and temporally. Root traits that characterize biomass, depth distributions, production and phenology, morphology, physiology, chemistry, and symbiotic relationships can be predictive of plants’ capacities to access and acquire nutrients and water, with links to aboveground processes like transpiration, wood productivity, and leaf phenology. In this review, we identify an emerging trend in the literature that tropical fine root biomass and production in surface soils are greatest in infertile or sufficiently moist soils. We also identify interesting paradoxes in tropical forest root responses to changing resources that merit further exploration. For example, specific root length, which typically increases under resource scarcity to expand the volume of soil explored, instead can increase with greater base cation availability, both across natural tropical forest gradients and in fertilization experiments. Also, nutrient additions, rather than reducing mycorrhizal colonization of fine roots as might be expected, increased colonization rates under scenarios of water scarcity in some forests. Efforts to include fine root traits and functions in vegetation models have grown more sophisticated over time, yet there is a disconnect between the emphasis in models characterizing nutrient and water uptake rates and carbon costs versus the emphasis in field experiments on measuring root biomass, production, and morphology in response to changes in resource availability. Closer integration of field and modeling efforts could connect mechanistic investigation of fine-root dynamics to ecosystem-scale understanding of nutrient and water cycling, allowing us to better predict tropical forest-climate feedbacks.

54 ENVIRONMENTAL SCIENCES

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Secondary-Side Active Rectifier Synchronization and Control in LCC-LC Compensated Inductive Power Transfer Systems

This paper proposes a communication-less synchronization and output power control strategy for LCC-LC compensated inductive power transfer systems with a secondaryside active rectifier. By replacing the passive rectifier with an active bridge, the proposed architecture eliminates the need for a separate secondary-side DC-DC converter and enables direct regulation of battery power. The key challenge in such a system is achieving robust synchronization of the secondary active bridge with the primary inverter without access to primary-side signals. To address this issue, the secondary-side variables are analyzed and the current through the secondary series inductor is identified as a load-independent synchronization variable with a fixed phase relationship to the primary excitation. A fixed-frequency second order generalized (SOGI)-based phase locked loop (PLL) is used to estimate the switching phase and frequency, and a phase-shift-based output power controller is developed using a phasor-transformer model of the active bridges. A modified control formulation is further introduced to remove phase-dependent loop-gain variation and simplify controller design. Simulation results validate the proposed method under both fixed and varying switching-frequency conditions, demonstrating successful frequency tracking from 82 kHz to 88 kHz and accurate output power regulation over a wide operating range. The proposed method offers a compact and effective solution for high-power IPT systems by enabling secondary-side synchronization and control without wireless communication or an additional DC-DC conversion stage.

Fernandes, Arnold Anthony [ORNL] (ORCID:0009000631

Fluorophilic Sigma(σ)‐Lock Self‐Healable Copolymers

Although F-Containing molecules and macromolecules are often used in molecular biology to increase the binding with Lewis acidic groups by introducing favorable C−F dipoles, there is virtually no experimental evidence and limited understanding of the nature of these interactions, especially their role in synthetic polymeric materials. These studies elucidate the molecular origin of inter- and intra-Chain interactions responsible for self-healing of F-Containing copolymers composed of pentafluorostyrene and n-butyl acrylate units (p(PFS/nBA). Guided by dynamic surface oscillating force (SOF) and spectroscopic measurements supported by molecular dynamics (MD) simulations, these studies show that the reformation of σ-σ orbitals in −C−F of PFS and CH 3 CH 2 − of nBA units enables the recovery of entropic energy via fluorophilic-σ-lock van der Waals forces when PFS/nBA molar ratios are ~50/50. The strength of these interactions determined experimentally for self-healable PFS/nBA compositions is in the order ~0.3 kcal/mol which primarily comes from fluorophilic-σ-lock (~70 %) contributions. These interactions are significantly diminished for non-self-healable counterparts. Strongly polarized −C−F σ orbitals create lateral dipolar forces enhancing the affinity towards −C−H orbitals, facilitating energetically favorable interactions. Entropic recovery driven by non-Covalent bonding offers a valuable tool in designing materials with unique functionalities, particularly self-healable batteries and energy storage devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

On-Chip Tuning of Superconductivity in Fullerides via Current-Driven Rb + Intercalation

An in-operando electro-intercalation method for the on-chip synthesis of alkali-metal-intercalated materials and their Raman spectroscopic and transport characterization in ultrahigh vacuum (UHV) is developed. We apply this method to synthesize fulleride superconductors via Rb + intercalation into a C 60 film. During the intercalation, we monitor the stoichiometry via UHV-Raman spectroscopy and probe superconductivity via transport measurements. An increase of the superconducting transition temperature from 7.0 K to 14.5 K is observed when the stoichiometry is tuned from Rb 2.7 C 60 to Rb 3 C 60 . In our experiment, an ionic Rb+ flux into the host material is induced by an applied electronic current via a Butler–Volmer-type mechanism. Electro-intercalation captivates through improved stoichiometric precision, the ability to smoothly vary stoichiometry via duration of current application, and the absence of a lower limit of the volume of the host material. It represents a powerful concept for the on-chip synthesis of intercalated materials, battery research, and beyond.

Raman

Semiconducting Electrides Derived from Sodalite: A First-Principles Study

Electrides are ionic crystals, with electrons acting as anions occupying well-defined lattice sites. These exotic materials have attracted considerable attention in recent years for potential applications in catalysis, rechargeable batteries, and display technology. Among this class of materials, electride semiconductors can further expand the horizon of potential applications due to the presence of a band gap. However, there are only limited reports on semiconducting electrides, hindering the understanding of their physical and chemical properties. In recent work, we initiated an approach to derive potential electrides via selective removal of symmetric Wyckoff sites of anions from existing complex minerals. Herein, we present a follow-up effort to design semiconducting electrides from parental complex sodalites. Among four candidate compounds, we found that a cubic Ca 4 Al 6 O 12 structure with the I-43m space group symmetry exhibits perfect electron localization at the sodalite cages, with a narrow electronic band gap of 1.8 eV, making it suitable for use in photocatalysis. Analysis of the electronic structures reveals that a lower electronegativity of the surrounding cations drives greater electron localization and promotes the formation of an electride band near the Fermi level. Our work proposes an alternative approach for designing new semiconducting electrides under ambient conditions and offers guidelines for further experimental exploration.

36 MATERIALS SCIENCE

Machine learning the electric field response of condensed phase systems using perturbed neural network potentials

Abstract The interaction of condensed phase systems with external electric fields is of major importance in a myriad of processes in nature and technology, ranging from the field-directed motion of cells (galvanotaxis), to geochemistry and the formation of ice phases on planets, to field-directed chemical catalysis and energy storage and conversion systems including supercapacitors, batteries and solar cells. Molecular simulation in the presence of electric fields would give important atomistic insight into these processes but applications of the most accurate methods such as ab-initio molecular dynamics (AIMD) are limited in scope by their computational expense. Here we introduce Perturbed Neural Network Potential Molecular Dynamics (PNNP MD) to push back the accessible time and length scales of such simulations. We demonstrate that important dielectric properties of liquid water including the field-induced relaxation dynamics, the dielectric constant and the field-dependent IR spectrum can be machine learned up to surprisingly high field strengths of about 0.2 V Å −1 without loss in accuracy when compared to ab-initio molecular dynamics. This is remarkable because, in contrast to most previous approaches, the two neural networks on which PNNP MD is based are exclusively trained on molecular configurations sampled from zero-field MD simulations, demonstrating that the networks not only interpolate but also reliably extrapolate the field response. PNNP MD is based on rigorous theory yet it is simple, general, modular, and systematically improvable allowing us to obtain atomistic insight into the interaction of a wide range of condensed phase systems with external electric fields.

Science & Technology - Other Topics

Oxidation Chemistry of Bicarbonate and Peroxybicarbonate: Implications for Carbonate Management in Energy Storage

Carbonate formation presents a major challenge to energy storage applications based on low-temperature CO 2 electrolysis and recyclable metal–air batteries. While direct electrochemical oxidation of (bi)carbonate represents a straightforward route for carbonate management, knowledge of the feasibility and mechanisms of direct oxidation is presently lacking. Herein, we report the isolation and characterization of the bis(triphenylphosphine)iminium salts of bicarbonate and peroxybicarbonate, thus enabling the examination of their oxidation chemistry. Infrared spectroelectrochemistry combined with time-resolved infrared spectroscopy reveals that the photoinduced oxidation of HCO 3 – by an Ir(III) photoreagent results in the generation of the short-lived bicarbonate radical in less than 50 ns. The highly acidic bicarbonate radical undergoes proton transfer with HCO 3 – to furnish the carbonate radical anion and H 2 CO 3 , leading to the eventual release of CO 2 and H 2 O, thus accounting for the appearance of H 2 O and CO 2 in both electrochemical and photochemical oxidation experiments. Here, the back reaction of the carbonate radical subsequently oxidizes the Ir(II) photoreagent, leading to carbonate. In the absence of this back reaction, dimerization of the carbonate radical provides entry into peroxybicarbonate, which we show undergoes facile oxidation to O 2 and CO 2 . Together, the results reported identify tangible pathways for the design of catalysts for the management of carbonate in energy storage applications.

25 ENERGY STORAGE

Atomic Evolution of Hydrogen Intercalation Wave Dynamics in Palladium Nanocrystals Revealed by Liquid-Phase Transmission Electron Microscopy

Solute-intercalation-induced phase separation creates spatial heterogeneities in host materials, a phenomenon ubiquitous in batteries, hydrogen storage, and other energy devices. Despite many efforts, probing intercalation processes at the atomic scale has been a significant challenge. By utilizing liquid-phase transmission electron microscopy (TEM), we study hydrogen (de)intercalation in palladium nanocrystals as a model system and have achieved unprecedented atomic-resolution imaging of hydrogen intercalation wave dynamics. Our observations reveal that intercalation wave mechanisms, instead of shrinking-core mechanisms, prevail at ambient temperature for palladium nanocubes ranging from ∼60 nm down to ∼10 nm. Systematic image analysis uncovers the atomic evolution of the hydrogen intercalation wave, transitioning from nonplanar and inclined boundaries to those closely aligned with {100} planes. Our kinetic Monte Carlo simulations demonstrate that the observed intercalation wave dynamics correspond to sorption pathways minimizing the lattice mismatch strain at the phase boundary. In conclusion, unveiling the atomic intercalation pathways holds profound implications for engineering intercalation-mediated devices and advancements in energy sciences.

Lee, Daewon [Lawrence Berkeley National Laboratory

Utilities Perspective on Protection Challenges with High IBR Penetration

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This presentation identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, we are looking broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the presentation summarizes on gathered data and internal experiences.

24 POWER TRANSMISSION AND DISTRIBUTION