Search NASA⌕ Search

SEARCH · Search NASA

Results for “reduced set methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

An experiment in hurricane track prediction using parallel computing methods

The barotropic model is used to explore the advantages of parallel processing in deterministic forecasting. We apply this model to the track forecasting of hurricane Elena (1985). In this particular application, solutions to systems of elliptic equations are the essence of the computational mechanics. One set of equations is associated with the decomposition of the wind into irrotational and nondivergent components - this determines the initial nondivergent state. Another set is associated with recovery of the streamfunction from the forecasted vorticity. We demonstrate that direct parallel methods based on accelerated block cyclic reduction (BCR) significantly reduce the computational time required to solve the elliptic equations germane to this decomposition and forecast problem. A 72-h track prediction was made using incremental time steps of 16 min on a network of 3000 grid points nominally separated by 100 km. The prediction took 30 sec on the 8-processor Alliant FX/8 computer. This was a speed-up of 3.7 when compared to the one-processor version. The 72-h prediction of Elena's track was made as the storm moved toward Florida's west coast. Approximately 200 km west of Tampa Bay, Elena executed a dramatic recurvature that ultimately changed its course toward the northwest. Although the barotropic track forecast was unable to capture the hurricane's tight cycloidal looping maneuver, the subsequent northwesterly movement was accurately forecasted as was the location and timing of landfall near Mobile Bay.

Song, Chang G.↗

The Dissociation Energies of He2, HeH, and ArH; A Bond Function Study

The bond energies and bond lengths are determined for He2, HeH, and ArH at the CCSD(T) level using both atom-centered basis sets and those that include bond functions. The addition of bond functions dramatically improves the rate of convergence of the results with respect to the size of the atom-centered basis set; with bond functions, triple zeta atom-centered basis set, outperform quintuple zeta basis sets without bond functions. The addition of bond functions also reduces the number of diffuse functions that must be added to the atom-centered sets. Employing bond functions appear to offer a very cost effective method of computing the interaction between weakly bound systems, especially for He.

Bauschlicher, Charles W., Jr.↗

Accurate Adaptive Level Set Method and Sharpening Technique for Three Dimensional Deforming Interfaces

In this paper, we demonstrate improved accuracy of the level set method for resolving deforming interfaces by proposing two key elements: (1) accurate level set solutions on adapted Cartesian grids by judiciously choosing interpolation polynomials in regions of different grid levels and (2) enhanced reinitialization by an interface sharpening procedure. The level set equation is solved using a fifth order WENO scheme or a second order central differencing scheme depending on availability of uniform stencils at each grid point. Grid adaptation criteria are determined so that the Hamiltonian functions at nodes adjacent to interfaces are always calculated by the fifth order WENO scheme. This selective usage between the fifth order WENO and second order central differencing schemes is confirmed to give more accurate results compared to those in literature for standard test problems. In order to further improve accuracy especially near thin filaments, we suggest an artificial sharpening method, which is in a similar form with the conventional re-initialization method but utilizes sign of curvature instead of sign of the level set function. Consequently, volume loss due to numerical dissipation on thin filaments is remarkably reduced for the test problems

Kim, Hyoungin↗

The GPU-enabled divide-expand-consolidate RI-MP2 method (DEC-RI-MP2)

We report porting of the Divide-Expand-Consolidate Resolution of the Identity second-order Møller–Plesset perturbation (DEC-RI-MP2) method to the graphic processing units (GPUs) using OpenACC compiler directives. It is shown that the OpenACC compiler directives implementation efficiently accelerates the rate-determining step of the DEC-RI-MP2 method with minor implementation effort. Moreover, the GPU acceleration results in a better load balance and thus in an overall scaling improvement of the DEC algorithm. The resulting cross-platform hybrid MPI/OpenMP/OpenACC implementation has scalable and portable performance on heterogeneous HPC architectures. The GPU-enabled code was benchmarked using a reduced version of the S12L test set of Stefan Grimme (Grimme, Chem. Eur. J. 2012, 18, 9955) consisting of supramolecular complexes up to 158 atoms and 4292 contracted basis functions (cc-pVTZ). The test set results demonstrate the general applicability of the DEC-RI-MP2 method showing results consistent with the DEC-RI-MP2 introductory paper (Baudin et al., J. Chem. Phys. 2016, 144, 054102) on molecules of complicated electronic structures. © 2016 Wiley Periodicals, Inc.

Chemistry↗

Dual energy CT: How well can pseudo-monochromatic imaging reduce metal artifacts?

Purpose: Dual Energy CT (DECT) provides so-called monoenergetic images based on a linear combination of the original polychromatic images. At certain patient-specific energy levels, corresponding to certain patient- and slice-dependent linear combination weights, e.g., E = 160 keV corresponds to α = 1.57, a significant reduction of metal artifacts may be observed. The authors aimed at analyzing the method for its artifact reduction capabilities to identify its limitations. The results are compared with raw data-based processing. Methods: Clinical DECT uses a simplified version of monochromatic imaging by linearly combining the low and the high kV images and by assigning an energy to that linear combination. Those pseudo-monochromatic images can be used by radiologists to obtain images with reduced metal artifacts. The authors analyzed the underlying physics and carried out a series expansion of the polychromatic attenuation equations. The resulting nonlinear terms are responsible for the artifacts, but they are not linearly related between the low and the high kV scan: A linear combination of both images cannot eliminate the nonlinearities, it can only reduce their impact. Scattered radiation yields additional noncanceling nonlinearities. This method is compared to raw data-based artifact correction methods. To quantify the artifact reduction potential of pseudo-monochromatic images, they simulated the FORBILD abdomen phantom with metal implants, and they assessed patient data sets of a clinical dual source CT system (100, 140 kV Sn) containing artifacts induced by a highly concentrated contrast agent bolus and by metal. In each case, they manually selected an optimal α and compared it to a raw data-based material decomposition in case of simulation, to raw data-based material decomposition of inconsistent rays in case of the patient data set containing contrast agent, and to the frequency split normalized metal artifact reduction in case of the metal implant. For each case, the contrast-to-noise ratio (CNR) was assessed. Results: In the simulation, the pseudo-monochromatic images yielded acceptable artifact reduction results. However, the CNR in the artifact-reduced images was more than 60% lower than in the original polychromatic images. In contrast, the raw data-based material decomposition did not significantly reduce the CNR in the virtual monochromatic images. Regarding the patient data with beam hardening artifacts and with metal artifacts from small implants the pseudo-monochromatic method was able to reduce the artifacts, again with the downside of a significant CNR reduction. More intense metal artifacts, e.g., as those caused by an artificial hip joint, could not be suppressed. Conclusions: Pseudo-monochromatic imaging is able to reduce beam hardening, scatter, and metal artifacts in some cases but it cannot remove them. In all cases, the CNR is significantly reduced, thereby rendering the method questionable, unless special post processing algorithms are implemented to restore the high CNR from the original images (e.g., by using a frequency split technique). Raw data-based dual energy decomposition methods should be preferred, in particular, because the CNR penalty is almost negligible.

60 APPLIED LIFE SCIENCES↗

Ultrasonic power measurement system based on acousto-optic interaction

Ultrasonic waves are widely used, with applications including the medical, military, and chemical fields. However, there are currently no effective methods for ultrasonic power measurement. Previously, ultrasonic power measurement has been reliant on mechanical methods such as hydrophones and radiation force balances. This paper deals with ultrasonic power measurement based on an unconventional method: acousto-optic interaction. Compared with mechanical methods, the optical method has a greater ability to resist interference and also has reduced environmental requirements. Therefore, this paper begins with an experimental determination of the acoustic power in water contained in a glass tank using a set of optical devices. Because the light intensity of the diffraction image generated by acousto-optic interaction contains the required ultrasonic power information, specific software was written to extract the light intensity information from the image through a combination of filtering, binarization, contour extraction, and other image processing operations. The power value can then be obtained rapidly by processing the diffraction image using a computer. The results of this work show that the optical method offers advantages that include accuracy, speed, and a noncontact measurement method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and application of a unified balancing approach with multiple constraints

The development of a general analytic approach to constrained balancing that is consistent with past influence coefficient methods is described. The approach uses Lagrange multipliers to impose orbit and/or weight constraints; these constraints are combined with the least squares minimization process to provide a set of coupled equations that result in a single solution form for determining correction weights. Proper selection of constraints results in the capability to: (1) balance higher speeds without disturbing previously balanced modes, thru the use of modal trial weight sets; (2) balance off-critical speeds; and (3) balance decoupled modes by use of a single balance plane. If no constraints are imposed, this solution form reduces to the general weighted least squares influence coefficient method. A test facility used to examine the use of the general constrained balancing procedure and application of modal trial weight ratios is also described.

Zorzi, E. S.↗

A simple technique to reduce evaporation of crystallization droplets by using plate lids with apertures for adding liquids

This article describes the use of evaporation control lids that are fitted to crystallization plates to improve the reproducibility of trials using as little as 5 nl. The plate lids contain apertures which are large enough for the transfer of protein containing droplets, but small enough to greatly reduce the rate of evaporation during the time needed to prepare the plate. A method is described for using plate lids to reduce evaporation in low-volume vapor-diffusion crystallization experiments. The plate lids contain apertures through which the protein and precipitants were added to different crystallization microplates (the reservoir was filled before fitting the lids). Plate lids were designed for each of these commonly used crystallization microplates. This system minimizes the dehydration of crystallization droplets containing just a few nanolitres of protein and precipitant, and results in more reproducible diffraction from the crystals. For each lid design, changes in the weight of the plates were used to deduce the rate of evaporation under different conditions of temperature, air movement, droplet size and precipitant. For comparison, the state of dehydration was also visually assessed throughout the experiment. Finally, X-ray diffraction methods were used to compare the diffraction of protein crystals that were conventionally prepared against those that were prepared on plates with plate lids. The measurements revealed that the plate lids reduced the rate of evaporation by 63–82%. Crystals grown in 5 nl drops that were set up with plate lids diffracted to higher resolution than similar crystals from drops that were set up without plate lids. The results demonstrate that plate lids can be instrumental for improving few-nanolitre crystallizations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Comparison of Equilibrium and Nonequilibrium Approaches for Relative Binding Free Energy Predictions

Alchemical relative binding free energy calculations have recently found important applications in drug optimization. A series of congeneric compounds are generated from a preidentified lead compound, and their relative binding affinities to a protein are assessed in order to optimize candidate drugs. While methods based on equilibrium thermodynamics have been extensively studied, an approach based on nonequilibrium methods has recently been reported together with claims of its superiority. However, these claims pay insufficient attention to the basis and reliability of both methods. Here we report a comparative study of the two approaches across a large data set, comprising more than 500 ligand transformations spanning in excess of 300 ligands binding to a set of 14 diverse protein targets. Ensemble methods are essential to quantify the uncertainty in these calculations, not only for the reasons already established in the equilibrium approach but also to ensure that the nonequilibrium calculations reside within their domain of validity. If and only if ensemble methods are applied, we find that the nonequilibrium method can achieve accuracy and precision comparable to those of the equilibrium approach. Compared to the equilibrium method, the nonequilibrium approach can reduce computational costs but introduces higher computational complexity and longer wall clock times. There are, however, cases where the standard length of a nonequilibrium transition is not sufficient, necessitating a complete rerun of the entire set of transitions. This significantly increases the computational cost and proves to be highly inconvenient during large-scale applications. Our findings provide a key set of recommendations that should be adopted for the reliable implementation of nonequilibrium approaches to relative binding free energy calculations in ligand-protein systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deep Learning Super-Resolution X-Ray Computed Tomography Algorithms for Additive Manufacturing

Industrial X-ray computed tomography (XCT) is a nondestructive method for inspection and characterization of additively manufactured (AM) materials and parts. In practice, the resolution of XCT can be limited by factors such as detector binning, restricted field of view for large-scale objects, system blur, motion during scanning, and acquisition settings. These limitations can reduce the detectability of critical flaws such as pores, cracks, and lack of fusion. Super-resolution (SR) techniques offer a promising solution for improving the effective resolution and image quality of XCT reconstructions without the need for expensive hardware upgrades or laborious, time-consuming scans. In particular, deep learning-based SR methods have garnered attention in recent years as powerful tools for reconstructing high-resolution volumes from low-resolution inputs. In this work, a novel deep learning-based SR method is proposed for XCT scans of AM parts, and compared against several existing state-of-the-art (SOTA) methods. The proposed method, Simurgh-SR, is built on the pre-existing Simurgh framework and consists of a 2.5D U-Net trained to map low-quality inputs containing noise and artifacts to high-quality reconstructions characterized by higher flaw contrast, better noise texture, and reduced artifacts. The experimental results demonstrate superior performance of Simurgh-SR in performing 4× SR on real industrial XCT scans of thick 316L components, enhancing the structural similarity score and peak signal-to-noise ratio (>7dB) compared to the LR counterpart while improving the F1-score for flaw detection by more than 2.3× when compared to alternative SOTA SR methods. This improvement enables more accurate and significantly faster characterization of metal AM components. Additionally, Simurgh-SR was trained for both 2X and 4X SR and performs effectively at both levels, enabling the use of a single model for various SR factors.

Rahman, Obaid [ORNL] (ORCID:0000000277810840)↗

Comprehensive helicopter rotor instrumentation - A retrofit approach using miniature transducers

This paper reports an approach used to retrofit a set of full-scale main rotor blades with 290 miniature pressure transducers, 46 strain gages, and 24 miniature accelerometers. Normally, in order to avoid disturbing the aerodynamics of the rotor flow field, the pressure instrumentation must be integrally built into the body of the rotor blades. However, using a method developed with NASA, miniature pressure transducers are mounted to the blade exterior surface without degrading the quality of the blade aerodynamics. Moreover, it is estimated that this approach reduced costs by more than 50 percent over building a set of pressure instrumented blades. The aerodynamic measurement objectives are presented as are instrumentation design considerations, type of instrumentation used, assembly process, and the installed instrumentation characteristics.

Jacklin, Stephen A.↗

The Potential for Bayesian Compressive Sensing to Significantly Reduce Electron Dose in High Resolution STEM Images

The use of high resolution imaging methods in the scanning transmission electron microscope (STEM) is limited in many cases by the sensitivity of the sample to the beam and the onset of electron beam damage (for example in the study of organic systems, in tomography and during in-situ experiments). To demonstrate that alternative strategies for image acquisition can help alleviate this beam damage issue, here we apply compressive sensing via Bayesian dictionary learning to high resolution STEM images. These experiments successively reduce the number of pixels in the image (thereby reducing the overall dose while maintaining the high resolution information) and show promising results for reconstructing images from this reduced set of randomly collected measurements. We show that this approach is valid for both atomic resolution images and nanometer resolution studies, such as those that might be used in tomography datasets, by applying the method to images of strontium titanate and zeolites. As STEM images are acquired pixel by pixel while the beam is scanned over the surface of the sample, these post acquisition manipulations of the images can, in principle, be directly implemented as a low-dose acquisition method with no change in the electron optics or alignment of the microscope itself.

compressive sensing↗

Cone beam x-ray luminescence computed tomography: A feasibility study

Purpose: The appearance of x-ray luminescence computed tomography (XLCT) opens new possibilities to perform molecular imaging by x ray. In the previous XLCT system, the sample was irradiated by a sequence of narrow x-ray beams and the x-ray luminescence was measured by a highly sensitive charge coupled device (CCD) camera. This resulted in a relatively long sampling time and relatively low utilization of the x-ray beam. In this paper, a novel cone beam x-ray luminescence computed tomography strategy is proposed, which can fully utilize the x-ray dose and shorten the scanning time. The imaging model and reconstruction method are described. The validity of the imaging strategy has been studied in this paper. Methods: In the cone beam XLCT system, the cone beam x ray was adopted to illuminate the sample and a highly sensitive CCD camera was utilized to acquire luminescent photons emitted from the sample. Photons scattering in biological tissues makes it an ill-posed problem to reconstruct the 3D distribution of the x-ray luminescent sample in the cone beam XLCT. In order to overcome this issue, the authors used the diffusion approximation model to describe the photon propagation in tissues, and employed the sparse regularization method for reconstruction. An incomplete variables truncated conjugate gradient method and permissible region strategy were used for reconstruction. Meanwhile, traditional x-ray CT imaging could also be performed in this system. The x-ray attenuation effect has been considered in their imaging model, which is helpful in improving the reconstruction accuracy. Results: First, simulation experiments with cylinder phantoms were carried out to illustrate the validity of the proposed compensated method. The experimental results showed that the location error of the compensated algorithm was smaller than that of the uncompensated method. The permissible region strategy was applied and reduced the reconstruction error to less than 2 mm. The robustness and stability were then evaluated from different view numbers, different regularization parameters, different measurement noise levels, and optical parameters mismatch. The reconstruction results showed that the settings had a small effect on the reconstruction. The nonhomogeneous phantom simulation was also carried out to simulate a more complex experimental situation and evaluated their proposed method. Second, the physical cylinder phantom experiments further showed similar results in their prototype XLCT system. With the discussion of the above experiments, it was shown that the proposed method is feasible to the general case and actual experiments. Conclusions: Utilizing numerical simulation and physical experiments, the authors demonstrated the validity of the new cone beam XLCT method. Furthermore, compared with the previous narrow beam XLCT, the cone beam XLCT could more fully utilize the x-ray dose and the scanning time would be shortened greatly. The study of both simulation experiments and physical phantom experiments indicated that the proposed method was feasible to the general case and actual experiments.

60 APPLIED LIFE SCIENCES↗

A comparison of earthquake backprojection imaging methods for dense local arrays

Backprojection imaging has recently become a practical method for local earthquake detection and location due to the deployment of densely sampled, continuously recorded, local seismograph arrays. While backprojection sometimes utilizes the full seismic waveform, the waveforms are often pre-processed and simplified to overcome imaging challenges. Real data issues include aliased station spacing, inadequate array aperture, inaccurate velocity model, low signal-to-noise ratio, large noise bursts and varying waveform polarity. We compare the performance of backprojection with four previously used data pre-processing methods: raw waveform, envelope, short-term averaging/long-term averaging and kurtosis. Our primary goal is to detect and locate events smaller than noise by stacking prior to detection to improve the signal-to-noise ratio. The objective is to identify an optimized strategy for automated imaging that is robust in the presence of real-data issues, has the lowest signal-to-noise thresholds for detection and for location, has the best spatial resolution of the source images, preserves magnitude, and considers computational cost. Imaging method performance is assessed using a real aftershock data set recorded by the dense AIDA array following the 2011 Virginia earthquake. Our comparisons show that raw-waveform backprojection provides the best spatial resolution, preserves magnitude and boosts signal to detect events smaller than noise, but is most sensitive to velocity error, polarity error and noise bursts. On the other hand, the other methods avoid polarity error and reduce sensitivity to velocity error, but sacrifice spatial resolution and cannot effectively reduce noise by stacking. Of these, only kurtosis is insensitive to large noise bursts while being as efficient as the raw-waveform method to lower the detection threshold; however, it does not preserve the magnitude information. For automatic detection and location of events in a large data set, we therefore recommend backprojecting kurtosis waveforms, followed by a second pass on the detected events using noise-filtered raw waveforms to achieve the best of all criteria.

58 GEOSCIENCES↗

Adaptive Scalpel Scanning Probe Microscopy for Enhanced Volumetric Sensing in Tomographic Analysis

Controlling nanoscale tip‐induced material removal is crucial for achieving atomic‐level precision in tomographic sensing with atomic force microscopy (AFM). While advances have enabled volumetric probing of conductive features with nanometer accuracy in solid‐state devices, materials, and photovoltaics, limitations in spatial resolution and volumetric sensitivity persist. This work identifies and addresses in‐plane and vertical tip‐sample junction leakage as sources of parasitic contrast in tomographic AFM, hindering real‐space 3D reconstructions. Novel strategies are proposed to overcome these limitations. First, the contrast mechanisms analyzing nanosized conductive features are explored when confining current collection purely to in‐plane transport, thus allowing reconstruction with a reduction in the overestimation of the lateral dimensions. Furthermore, an adaptive tip‐sample biasing scheme is demonstrated for the mitigation of a class of artefacts induced by the high electric field inside the thin oxide when volumetrically reduced. This significantly enhances vertical sensitivity by approaching the intrinsic limits set by quantum tunneling processes, allowing detailed depth analysis in thin dielectrics. The effectiveness of these methods is showcased in tomographic reconstructions of conductive filaments in valence change memory, highlighting the potential for application in nanoelectronics devices and bulk materials and unlocking new limits for tomographic AFM.

36 MATERIALS SCIENCE↗

Materials informatics: From the atomic-level to the continuum

We report that in recent years materials informatics, which is the application of data science to problems in materials science and engineering, has emerged as a powerful tool for materials discovery and design. This relatively new field is already having a significant impact on the interpretation of data for a variety of materials systems, including those used in thermoelectrics, ferroelectrics, battery anodes and cathodes, hydrogen storage materials, polymer dielectrics, etc. Its practitioners employ the methods of multivariate statistics and machine learning in conjunction with standard computational tools (e.g., density-functional theory) to, for example, visualize and dimensionally reduce large data sets, identify patterns in hyperspectral data, parse microstructural images of polycrystals, characterize vortex structures in ferroelectrics, design batteries and, in general, establish correlations to extract important physics and infer structure-property-processing relationships. In this Overview, we critically examine the role of informatics in several important materials subfields, highlighting significant contributions to date and identifying known shortcomings. We specifically focus attention on the difference between the correlative approach of classical data science and the causative approach of physical sciences. From this perspective, we also outline some potential opportunities and challenges for informatics in the materials realm in this era of big data.

36 MATERIALS SCIENCE↗

Fixed-target protein serial microcrystallography with an x-ray free electron laser

We present results from experiments at the Linac Coherent Light Source (LCLS) demonstrating that serial femtosecond crystallography (SFX) can be performed to high resolution (,2.5 Å) using protein microcrystals deposited on an ultra-thin silicon nitride membrane and embedded in a preservation medium at room temperature. Data can be acquired at a high acquisition rate using x-ray free electron laser sources to overcome radiation damage, while sample consumption is dramatically reduced compared to flowing jet methods. We achieved a peak data acquisition rate of 10 Hz with a hit rate of ,38%, indicating that a complete data set could be acquired in about one 12-hour LCLS shift using the setup described here, or in even less time using hardware optimized for fixed target SFX. This demonstration opens the door to ultra low sample consumption SFX using the technique of diffraction-before-destruction on proteins that exist in only small quantities and/or do not produce the copious quantities of microcrystals required for flowing jet methods.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Facile synthesis of gold trisoctahedral nanocrystals with controllable sizes and dihedral angles

Shape-controlled synthesis of Au nanocrystals is of paramount importance to their applications in plasmonics, catalysis, and nanomedicine. While the synthesis of Au nanocrystals enclosed by low-index facets has been greatly advanced over the past two decades, only limited progress has been made for their high-index counterparts. Here in this paper we report a robust route to the facile synthesis of Au trisoctahedral nanocrystals enclosed by high-index facets. Unlike the previously reported methods, our synthesis was conducted at room temperature, together with the introduction a new Au(III) precursor that was much harder to reduce than AuCl4–. In the setting of seed-mediated growth, the trisoctahedral nanocrystals could be readily prepared with sizes controllable from 20–80 nm and dihedral angles tunable in the range of 120–180 degrees. We further used computational modeling to demonstrate that the surface-functionalized Au trisoctahedral nanocrystal could outperform its spherical counterpart in terms of endocytic efficacy under identical conditions.

36 MATERIALS SCIENCE↗