Search NASA⌕ Search

SEARCH · Search NASA

Results for “single photon processes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Performance of a high-sensitivity dedicated cardiac SPECT scanner for striatal uptake quantification in the brain based on analysis of projection data

Purpose: The authors have previously reported the advantages of high-sensitivity single-photon emission computed tomography (SPECT) systems for imaging structures located deep inside the brain. DaTscan (Isoflupane I-123) is a dopamine transporter (DaT) imaging agent that has shown potential for early detection of Parkinson disease (PD), as well as for monitoring progression of the disease. Realizing the full potential of DaTscan requires efficient estimation of striatal uptake from SPECT images. They have evaluated two SPECT systems, a conventional dual-head gamma camera with low-energy high-resolution collimators (conventional) and a dedicated high-sensitivity multidetector cardiac imaging system (dedicated) for imaging tasks related to PD. Methods: Cramer-Rao bounds (CRB) on precision of estimates of striatal and background activity concentrations were calculated from high-count, separate acquisitions of the compartments (right striata, left striata, background) of a striatal phantom. CRB on striatal and background activity concentration were calculated from essentially noise-free projection datasets, synthesized by scaling and summing the compartment projection datasets, for a range of total detected counts. They also calculated variances of estimates of specific-to-nonspecific binding ratios (BR) and asymmetry indices from these values using propagation of error analysis, as well as the precision of measuring changes in BR on the order of the average annual decline in early PD. Results: Under typical clinical conditions, the conventional camera detected 2 M counts while the dedicated camera detected 12 M counts. Assuming a normal BR of 5, the standard deviation of BR estimates was 0.042 and 0.021 for the conventional and dedicated system, respectively. For an 8% decrease to BR = 4.6, the signal-to-noise ratio were 6.8 (conventional) and 13.3 (dedicated); for a 5% decrease, they were 4.2 (conventional) and 8.3 (dedicated). Conclusions: This implies that PD can be detected earlier with the dedicated system than with the conventional system; therefore, earlier identification of PD progression should be possible with the high-sensitivity dedicated SPECT camera.

60 APPLIED LIFE SCIENCES↗

Bio-Medical and Plant Biology Imaging Tools Derived from Nuclear Physics Detector Development

Basic nuclear physics research requires continuing advances in detector technology. Often, new detection technology can have applications outside basic nuclear physics research. For over 80 years various sciences have been using radioactive isotopes as tracers for increasing our understanding of biological processes in living systems. New nuclear physics detection technologies using scintillators and photo multipliers have been used to develop imaging tools for radioisotope detection and imaging in bio-medical and plant biology applications. Nuclear imaging techniques such as positron emission tomography (PET) and single photon emission computed tomography (SPECT) benefit greatly from advances in nuclear physics detector technology. Bio-medical research utilizing animals as in pre-clinical research and in clinical applications such as cancer detection and treatment have benefited much from nuclear physics detector advances. New imaging tools are being developed for plant biology research to enhance our understanding of metabolic processes necessary for efficient biofuel production in a changing environment and of best bioassays for environmental remediation. The Radiation Detector and Imaging Group at Thomas Jefferson National Accelerator Facility has been applying detector technology to these applications. The examples of detector systems for medical and plant biology applications as well as scientific motivations driving use of radioisotope tracers in these applications will be presented.

Weisenberger, Andrew↗

WE-H-206-00: Advances in Preclinical Imaging

Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly to biomedical research during the past decade. The initial development was an extension of clinical PET/CT and SPECT/CT from human to small animals and combine the unique functional information obtained from PET and SPECT with anatomical information provided by the CT in registered multi-modality images. The requirements to image a mouse whose size is an order of magnitude smaller than that of a human have spurred advances in new radiation detector technologies, novel imaging system designs and special image reconstruction and processing techniques. Examples are new detector materials and designs with high intrinsic resolution, multi-pinhole (MPH) collimator design for much improved resolution and detection efficiency compared to the conventional collimator designs in SPECT, 3D high-resolution and artifact-free MPH and sparse-view image reconstruction techniques, and iterative image reconstruction methods with system response modeling for resolution recovery and image noise reduction for much improved image quality. The spatial resolution of PET and SPECT has improved from ∼6–12 mm to ∼1 mm a few years ago to sub-millimeter today. A recent commercial small animal SPECT system has achieved a resolution of ∼0.25 mm which surpasses that of a state-of-art PET system whose resolution is limited by the positron range. More recently, multimodality SA PET/MRI and SPECT/MRI systems have been developed in research laboratories. Also, multi-modality SA imaging systems that include other imaging modalities such as optical and ultrasound are being actively pursued. In this presentation, we will provide a review of the development, recent advances and future outlook of multi-modality molecular imaging of small animals. Learning Objectives: To learn about the two major multi-modality molecular imaging techniques of small animals. To learn about the spatial resolution achievable by the molecular imaging systems for small animal today. To learn about the new multi-modality imaging instrumentation and techniques that are being developed. Sang Hyun Cho; X-ray fluorescence (XRF) imaging, such as x-ray fluorescence computed tomography (XFCT), offers unique capabilities for accurate identification and quantification of metals within the imaging objects. As a result, it has emerged as a promising quantitative imaging modality in recent years, especially in conjunction with metal-based imaging probes. This talk will familiarize the audience with the basic principles of XRF/XFCT imaging. It will also cover the latest development of benchtop XFCT technology. Additionally, the use of metallic nanoparticles such as gold nanoparticles, in conjunction with benchtop XFCT, will be discussed within the context of preclinical multimodal multiplexed molecular imaging. Learning Objectives: To learn the basic principles of XRF/XFCT imaging To learn the latest advances in benchtop XFCT development for preclinical imaging Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; L. Wang, Funding Support: NIH; COI: Microphotoacoustics; S. Cho, Yes: ;NIH/NCI grant R01CA155446 DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗

WE-H-206-02: Recent Advances in Multi-Modality Molecular Imaging of Small Animals

Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly to biomedical research during the past decade. The initial development was an extension of clinical PET/CT and SPECT/CT from human to small animals and combine the unique functional information obtained from PET and SPECT with anatomical information provided by the CT in registered multi-modality images. The requirements to image a mouse whose size is an order of magnitude smaller than that of a human have spurred advances in new radiation detector technologies, novel imaging system designs and special image reconstruction and processing techniques. Examples are new detector materials and designs with high intrinsic resolution, multi-pinhole (MPH) collimator design for much improved resolution and detection efficiency compared to the conventional collimator designs in SPECT, 3D high-resolution and artifact-free MPH and sparse-view image reconstruction techniques, and iterative image reconstruction methods with system response modeling for resolution recovery and image noise reduction for much improved image quality. The spatial resolution of PET and SPECT has improved from ∼6–12 mm to ∼1 mm a few years ago to sub-millimeter today. A recent commercial small animal SPECT system has achieved a resolution of ∼0.25 mm which surpasses that of a state-of-art PET system whose resolution is limited by the positron range. More recently, multimodality SA PET/MRI and SPECT/MRI systems have been developed in research laboratories. Also, multi-modality SA imaging systems that include other imaging modalities such as optical and ultrasound are being actively pursued. In this presentation, we will provide a review of the development, recent advances and future outlook of multi-modality molecular imaging of small animals. Learning Objectives: To learn about the two major multi-modality molecular imaging techniques of small animals. To learn about the spatial resolution achievable by the molecular imaging systems for small animal today. To learn about the new multi-modality imaging instrumentation and techniques that are being developed. Sang Hyun Cho; X-ray fluorescence (XRF) imaging, such as x-ray fluorescence computed tomography (XFCT), offers unique capabilities for accurate identification and quantification of metals within the imaging objects. As a result, it has emerged as a promising quantitative imaging modality in recent years, especially in conjunction with metal-based imaging probes. This talk will familiarize the audience with the basic principles of XRF/XFCT imaging. It will also cover the latest development of benchtop XFCT technology. Additionally, the use of metallic nanoparticles such as gold nanoparticles, in conjunction with benchtop XFCT, will be discussed within the context of preclinical multimodal multiplexed molecular imaging. Learning Objectives: To learn the basic principles of XRF/XFCT imaging To learn the latest advances in benchtop XFCT development for preclinical imaging Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; L. Wang, Funding Support: NIH; COI: Microphotoacoustics; S. Cho, Yes: ;NIH/NCI grant R01CA155446 DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗

Mode Multiplexing for Scalable Cavity-Enhanced Operations in Neutral-Atom Arrays

Neutral-atom arrays provide a versatile platform for quantum information processing. However, in large-scale arrays, efficient photon collection remains a bottleneck for key tasks such as fast, nondestructive qubit readout and remote entanglement distribution. We propose a cavity-based approach that enables fast, parallel operations over many atoms using multiple modes of a single optical cavity. By selectively shifting the relevant atomic transitions, each atom can be coupled to a distinct cavity mode, allowing independent simultaneous processing. We present practical system designs that support cavity-mode multiplexing with up to 50 modes, enabling rapid mid-circuit syndrome extraction and significantly enhancing entanglement distribution rates between remote atom arrays. This approach offers a scalable solution to core challenges in neutral-atom arrays, advancing the development of practical quantum technologies.

Aqua, Ziv [Massachusetts Institute of Technology (↗

Two-photon double ionization of atomic beryllium with ultrashort laser pulses

Here, we investigate the two-photon double ionization of beryllium atom induced by ultrashort pulses. We use a time-dependent formalism to evaluate the ionization amplitudes and generalized cross sections for the ejection of the 2s 2 valence shell electrons in the presence of a fully occupied 1s 2 frozen core shell. The relative contributions of the two-photon direct and sequential process are systematically explored by varying both pulse duration and central frequency. The energy and angular differential ionization yields reveal the signatures of both mechanisms, as well as the role of electron correlation in both the single and double ionization continua. In contrast with previous results on the helium atom, the presence of an electronic core strongly affects the final state leading to back-to-back electron emission even in the a priori less correlated two-photon sequential mechanism. In particular, a dominant pathway via excitation ionization through the Be + (2p) determines the profiles and pulse-duration dependencies of the energy and angle differential yields.

74 ATOMIC AND MOLECULAR PHYSICS↗

Design Considerations Of A Compton Camera For Low Energy Medical Imaging

Development of a Compton camera for low energy medical imaging applications is underway. The ProSPECTus project aims to utilize position sensitive detectors to generate high quality images using electronic collimation. This method has the potential to significantly increase the imaging efficiency compared with mechanically collimated SPECT systems, a highly desirable improvement on clinical systems. Design considerations encompass the geometrical optimisation and evaluation of image quality from the system which is to be built and assessed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing the photoluminescence properties of gold nanoclusters by fluorescence lifetime correlation spectroscopy

Gold nanoclusters (Au NCs) have attracted much attention for promising applications in biological imaging owing to their tiny sizes and biocompatibility. So far, most efforts have been focused on the strategies for fabricating high-quality Au NCs and then characterized by conventional ensemble measurement. Here, a fusion single-molecule technique combining fluorescence correlation spectroscopy and time-correlated single-photon counting can be successfully applied to probe the photoluminescence (PL) properties for sparse Au NCs. In this case, the triplet-state dynamics and diffusion process can be observed simultaneously and the relevant time constants can be derived. This work provides a complementary insight into the PL mechanism at the molecular levels for Au NCs in solution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rational design of efficient defect-based quantum emitters

Single-photon emitters are an essential component of quantum networks, and defects or impurities in semiconductors are a promising platform to realize such quantum emitters. Here, we present a model that encapsulates the essential physics of coupling to phonons, which governs the behavior of real single-photon emitters, and critically evaluate several approximations that are commonly utilized. Emission in the telecom wavelength range is highly desirable, but our model shows that nonradiative processes are greatly enhanced at these low photon energies, leading to a decrease in efficiency. Our results suggest that reducing the phonon frequency is a fruitful avenue to enhance the efficiency.

Optics↗

Fast entanglement detection for unknown states of two spatial qutrits

We investigate the practicality of the method proposed by Maciel et al. [Phys. Rev. A. 80, 032325 (2009).] for detecting the entanglement of two spatial qutrits (three-dimensional quantum systems), which are encoded in the discrete transverse momentum of single photons transmitted through a multislit aperture. The method is based on the acquisition of partial information of the quantum state through projective measurements, and a data processing analysis done with semidefinite programs. This analysis relies on generating gradually an optimal entanglement witness operator, and numerical investigations have shown that it allows for the entanglement detection of unknown states with a cost much lower than full state tomography.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nonlinear Quantum Optics in a Waveguide: Distinct Single Photons Strongly Interacting at the Single Atom Level

We propose a waveguide-QED system where two single photons of distinct frequency or polarization interact strongly. The system consists of a single ladder-type three level atom coupled to a waveguide. When both optical transitions are coupled strongly to the waveguide's mode, we show that a control photon tuned to the upper transition induces a {pi} phase shift and tunneling of a probe photon tuned to the otherwise reflective lower transition. Furthermore, the system exhibits single photon scattering by a classical control beam. Waveguide-QED schemes could be an alternative to high quality cavities or dense atomic ensembles in quantum information processing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Segmented slant hole collimator for stationary cardiac SPECT: Monte Carlo simulations

Purpose: This work is a preliminary study of a stationary cardiac SPECT system. The goal of this research is to propose a stationary cardiac SPECT system using segmented slant-hole collimators and to perform computer simulations to test the feasibility. Compared to the rotational SPECT, a stationary system has a benefit of acquiring temporally consistent projections. The most challenging issue in building a stationary system is to provide sufficient projection view-angles. Methods: A GATE (GEANT4 application for tomographic emission) Monte Carlo model was developed to simulate a two-detector stationary cardiac SPECT that uses segmented slant-hole collimators. Each detector contains seven segmented slant-hole sections that slant to a common volume at the rotation center. Consequently, 14 view-angles over 180° were acquired without any gantry rotation. The NCAT phantom was used for data generation and a tailored maximum-likelihood expectation-maximization algorithm was used for image reconstruction. Effects of limited number of view-angles and data truncation were carefully evaluated in the paper. Results: Simulation results indicated that the proposed segmented slant-hole stationary cardiac SPECT system is able to acquire sufficient data for cardiac imaging without a loss of image quality, even when the uptakes in the liver and kidneys are high. Seven views are acquired simultaneously at each detector, leading to 5-fold sensitivity gain over the conventional dual-head system at the same total acquisition time, which in turn increases the signal-to-noise ratio by 19%. The segmented slant-hole SPECT system also showed a good performance in lesion detection. In our prototype system, a short hole-length was used to reduce the dead zone between neighboring collimator segments. The measured sensitivity gain is about 17-fold over the conventional dual-head system. Conclusions: The GATE Monte Carlo simulations confirm the feasibility of the proposed stationary cardiac SPECT system with segmented slant-hole collimators. The proposed collimator consists of combined parallel and slant holes, and the image on the detector is not reduced in size.

60 APPLIED LIFE SCIENCES↗

Technical Note: Development of a 3D printed subresolution sandwich phantom for validation of brain SPECT analysis

Purpose: To make an adaptable, head shaped radionuclide phantom to simulate molecular imaging of the brain using clinical acquisition and reconstruction protocols. This will allow the characterization and correction of scanner characteristics, and improve the accuracy of clinical image analysis, including the application of databases of normal subjects. Methods: A fused deposition modeling 3D printer was used to create a head shaped phantom made up of transaxial slabs, derived from a simulated MRI dataset. The attenuation of the printed polylactide (PLA), measured by means of the Hounsfield unit on CT scanning, was set to match that of the brain by adjusting the proportion of plastic filament and air (fill ratio). Transmission measurements were made to verify the attenuation of the printed slabs. The radionuclide distribution within the phantom was created by adding {sup 99m}Tc pertechnetate to the ink cartridge of a paper printer and printing images of gray and white matter anatomy, segmented from the same MRI data. The complete subresolution sandwich phantom was assembled from alternate 3D printed slabs and radioactive paper sheets, and then imaged on a dual headed gamma camera to simulate an HMPAO SPECT scan. Results: Reconstructions of phantom scans successfully used automated ellipse fitting to apply attenuation correction. This removed the variability inherent in manual application of attenuation correction and registration inherent in existing cylindrical phantom designs. The resulting images were assessed visually and by count profiles and found to be similar to those from an existing elliptical PMMA phantom. Conclusions: The authors have demonstrated the ability to create physically realistic HMPAO SPECT simulations using a novel head-shaped 3D printed subresolution sandwich method phantom. The phantom can be used to validate all neurological SPECT imaging applications. A simple modification of the phantom design to use thinner slabs would make it suitable for use in PET.

60 APPLIED LIFE SCIENCES↗

Deeply virtual Compton scattering with CLAS and CLAS12

Generalised Parton Distributions (GPDs) offer an insight into the three-dimensional structure of the nucleon and its internal dynamics, relating the transverse position of quarks to their longitudinal momentum. Two effective means of accessing GPDs are Deeply Virtual Compton Scattering (DVCS) and Meson Production (DVMP), in which a high energy electron scatters from a single quark in the nucleon and, respectively, a real photon or meson is produced as a result. Jefferson Laboratory (JLab), USA, is ideally suited for measuring these processes and a very active experimental programme has been underway in the recent years, making use of the lab's continuous electron beam up to 6 GeV in energy and its large angle spectrometer CLAS. In the future, a vast, new, as-yet unprobed kinematic region will become experimentally accessible when the current upgrade of the JLab accelerator to operate at a maximum energy of 12 GeV is completed in a few years. It is being complemented by the construction of a new suite of detectors, CLAS12, a number of them optimised specifically for exclusive reconstruction of DVCS and DVMP in the new kinematic region. We present a selection of recent results of DVCS and DVMP measurements using CLAS and introduce the exciting experimental programme planned for the future with CLAS12.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Interplay between phonon downconversion efficiency, density of states at Fermi energy, and intrinsic energy resolution for microwave kinectic inductance detectors

Microwave Kinetic Inductance detectors (MKIDs) have been recognized as a powerful new tool for single photon detection. These highly multiplexed superconducting devices give timing and energy measurement for every detected photon. However, the full potential of MKID single photon spectroscopy has not been reached , the achieved energy resolution is lower than expected from first principles. Here, we study the efficiency in the phonon downconversion process following the absorption of energetic photons in MKIDs. Assuming previously published material properties, we measure an average downconversion efficiency for three TiN resonators is $\eta$=0.14. We discuss how this efficiency can impact the intrinsic energy resolution of MKID, and how any uncertainty in the unknown density of electron states at the Fermi energy directly affects the efficiency estimations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of coherence of niobium-based resonators enabled by a fast-sealing microwave cavity

Resonators and qubits with a niobium (Nb) base metal layer achieve some of the highest coherence times in superconducting quantum devices. The performance of such devices is often limited by loss associated with two-level systems, which are found primarily at material surfaces and interfaces. The metal-air (MA) interface is a major contributor to device loss. In this work, we develop a fast-sealing microwave cavity that enables devices to be placed under vacuum within five minutes of oxide removal, thereby significantly reducing the MA interface loss compared to common device processing and packaging approaches. Using coplanar stripline resonators, we demonstrate that devices sealed in such a cavity exhibit internal quality factors exceeding one million at single-photon power. After re-exposure to air, the devices show downward resonance frequency shifts and quality factor degradations, quantitatively consistent with a model of Nb oxide regrowth. The fast-sealing microwave cavity provides a practical and consistent method to mitigate MA interface loss and sustain high coherence in Nb devices, and establishes a controlled platform for studying metal oxide regrowth kinetics and dielectric properties, the understanding of which is critical to achieving high coherence in superconducting quantum devices.

Zhang, C. [Waterloo U., IQC; Waterloo U.]↗

Using double pulse laser ablation in air to enhance the strength of laser-driven shocks

In the process of multi-pulse laser ablation, inter-pulse delay time, Δ t , is known to be an important parameter for maximizing ablation efficiency as well as impulse imparted to the target. In this work, using photon Doppler velocimetry, we show that for single pairs of colinear pulses (1064 nm, 8 ns, ∼ 60 J cm -2 per pulse) in air, the peak free surface velocity of the back surface of an aluminum target (125 µm thick) is increased, by a factor of nearly 3, when Δ t = 10 microseconds, compared with both pulses arriving simultaneously (Δ t = 0). Fast imaging of the ablation process suggests this enhancement is due to rarefaction of the contiguous air in the passage of the leading shock produced by ablation, which then in turn allows a larger fraction of the energy of the second pulse to reach the target surface. This interpretation is strengthened by additional experiments in which the two pulses do not overlap on the target surface, but the shock strength is nevertheless enhanced. Given a fixed energy budget this work suggests a prescription for maximizing laser-driven shock strength by judicious choice of inter-pulse delay.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measuring signatures in photon angular spectra to distinguish nonlinear Compton scattering models

The collision of a high-energy electron beam with a laser pulse may be used to study radiation reaction and nonlinear Compton scattering among many other processes in strong-field quantum electrodynamics. Predictions from simulation and theory for these interactions rely on a number of approximations and assumptions that have not been experimentally tested. Here, experimentally measurable signatures are identified that might be able to distinguish between radiation reaction models, i.e., classical or quantum, or between the local constant field and local monochromatic approximations used to calculate the properties of the nonlinear Compton process. These signatures are considered through Monte Carlo simulations of various experimental conditions that are relevant to today's laser facilities. Potential detection schemes for measuring the signatures are proposed. We find that single-photon counting of keV photons to resolve harmonics and scintillator-based detection of MeV photons may allow us to validate nonlinear Compton scattering models and radiation reaction models respectively. This will require electron beams with divergence angles less than 2 mrad and less than 20% energy spread.

Russell, Brandon K↗