Search NASA⌕ Search

SEARCH · Search NASA

Results for “task”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Numerical simulation of gas dynamics and heat exchange tasks in fuel assemblies of the nuclear reactors

This report presents a PC-based program for solution gas dynamics and heat exchange mathematical tasks in fuel assemblies of the fast-neutron nuclear reactors. A fuel assembly consisting of bulk heat-generating elements, which are integrated together by the system of supply and pressure manifolds, is examined. Spherical heat-generating microelements, which contain nuclear fuel, are pulled into the heat-generating elements. Gaseous coolant proceed from supply manifolds to heat-generating elements, where it withdraws the nuclear reaction heat and assembles in pressure manifolds.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multitasking information behavior, information task switching and anxiety: An exploratory study

Multitasking information behavior involves multiple forms of information searching such as library and Web search. Few researchers, however, have explored multitasking information behavior and information task switching in libraries in conjunction with psychological variables. This study explored this behavior in terms of anxiety under time pressure. This was an exploratory case study. Participant searched information for three unrelated everyday life information topics during a library visit, in a timeframe of one hour. The data collection tools used were: diary, observation, interview, and the State-Trait Anxiety Inventory test. Participant took the Trait-anxiety test before the library visit to measure anxiety level as a personal characteristic. She also took State-anxiety test before, during and after the library visit to measure anxiety levels regarding the information seeking behavior. The results suggested that participant had high levels of anxiety at the beginning of the multitasking information behavior. The reason for that was the concern about the performance as well as the identification of the right resources. During the multitasking information behavior, participant still had anxiety to find the right information. The levels of anxiety, however, were less due to library’s good organized structure. At the end of the information seeking process, the levels of anxiety dropped significant and therefore calm and safety returned. Finally, participant searched information for topics that were more important and for which she had prior knowledge When people, under time pressure, have access to well organized information, the levels of anxiety might decrease.

99 GENERAL AND MISCELLANEOUS↗

Molecular dynamics simulations of uranyl and plutonyl cations in a task-specific ionic liquid

Ionic liquids (ILs) are a unique class of solvents with potential applications in advanced separation technologies relevant to the nuclear industry. ILs are salts with low melting points and a wide range of tunable physical properties, such as viscosity, hydrophobiciy, conductivity, and liquidus range. ILs have negligible vapor pressure, are often non-flammable, and can have high thermal stability and a wide electrochemical window, making them attractive for use in separations processes relevant to the nuclear industry. Metal salts generally have a low solubility in ILs; however, by incorporating new functional groups into the IL cation or anion that promote complexation with the metal, the solubility can be greatly increased. One such task-specific ionic liquid (TSIL) is 1-carboxy-N, N, N-trimethylglycine bis(trifluoromethylsulfonyl)imide ([Hbet][Tf 2 N]). Water, which is detrimental for electrochemical separations, is a common impurity in ILs and can coordinate with actinyl cations, particularly in ILs containing only weakly coordinating components. Understanding the behavior of actinides in TSIL/water mixtures on a molecular level is vital for designing improved separations processes. Classical molecular dynamics simulations of uranyl(VI) and plutonyl(VI) in 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide ([EMIM][Tf 2 N]) with deprotonated Hbet (betaine) and water have been performed to understand the coordination and dynamics of the actinyl cations. We find that betaine is a much stronger ligand than water and prefers to coordinate the metal in a bidentate manner. Potential of mean force simulations yield a relative free energy for betaine coordination of approximately -120 to -90 kJ/mol in mixtures with water. As the amount of betaine coordinated to the actinide increases, the diffusion coefficient of the actinyl cation decreases. Moreover, the betaine ligand is able to bridge between two metal centers, resulting in dimeric complexes with actinide–actinide distances of ~5 Å. Potential of mean force simulations show that these structures are stable, with relative free energies of up to -40 kJ/mol. The crystal structure for [(UO 2 ) 2 (bet) 6 (H 2 O) 2 ][Tf 2 N] 4 shows that the betaine bridges between two uranium atoms to form dimeric complexes similar to those found in our simulations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

IEA Wind Task 32: Best Practices for the Certification of Lidar-Assisted Control Applications

Lidar-assisted control is a promising technology for reducing structural loads on wind turbines. Guidelines for certifying wind turbines with this technology are important for its widespread adoption. As a first step, an IEA Wind Task 32 workshop was held, bringing together wind turbine manufacturers, lidar suppliers, certifiers, consultants, and researchers to identify barriers to certification with lidar-assisted control and ideas for mitigating the barriers. Here this paper builds on the outcome of the workshop by providing an analysis of the areas affected and the remaining challenges. Further, initial best practices are given to address the challenges, covering the lidar system, control and protection systems, design loads, and type testing.

17 WIND ENERGY↗

Conceptual monopile and tower sizing for the IEA Wind Task 37 Borssele reference wind farm

This paper explores the preliminary design of the support structures for the IEA Wind Task 37 reference wind farm at the Borssele site III and IV. The study looks at two different design methods that might be used within larger wind farm system design optimization (i.e. lay-out, electrical systems, etc.). The first consists of a scaling tool that scales a detailed design according to the rated power, water depth, hub height and rotor diameter. The second is a physics-based optimization approach that relies on the WISDEM® design tool. This research compares the results of these two methods for the design of both the tower and monopile of the IEA 10-MW and 15-MW reference wind turbines at a range of sea depths (25 m, 30 m, 35 m, 40 m). The two tools yield very similar results in terms of monopile base diameter, support structure natural frequency and mass. WISDEM is then used to also investigate the sensitivity of the design to the tower top forces, wave conditions and the soil conditions. It is shown that tower top forces dominate the design. In general, large diameter structures can carry additional costs associated with manufacturing and transportation requirements. Thus, the paper is concluded with a trade-off study between mass and diameter that quantifies the effect of the reduction in monopile diameter with the increase in structural mass.

WIND ENERGY↗

The WorkQueue project: A task queue for the CMS workload management system

We present the development and first experience of a new component (termed WorkQueue) in the CMS workload management system. This component provides a link between a global request system (Request Manager) and agents (WMAgents) which process requests at compute and storage resources (known as sites). These requests typically consist of creation or processing of a data sample (possibly terabytes in size). Unlike the standard concept of a task queue, the WorkQueue does not contain fully resolved work units (known typically as jobs in HEP). This would require the WorkQueue to run computationally heavy algorithms that are better suited to run in the WMAgents. Instead the request specifies an algorithm that the WorkQueue uses to split the request into reasonable size chunks (known as elements). An advantage of performing lazy evaluation of an element is that expanding datasets can be accommodated by having job details resolved as late as possible. The WorkQueue architecture consists of a global WorkQueue which obtains requests from the request system, expands them and forms an element ordering based on the request priority. Each WMAgent contains a local WorkQueue which buffers work close to the agent, this overcomes temporary unavailability of the global WorkQueue and reduces latency for an agent to begin processing. Elements are pulled from the global WorkQueue to the local WorkQueue and into the WMAgent based on the estimate of the amount of work within the element and the resources available to the agent. WorkQueue is based on CouchDB, a document oriented NoSQL database. The WorkQueue uses the features of CouchDB (map/reduce views and bi-directional replication between distributed instances) to provide a scalable distributed system for managing large queues of work. The project described here represents an improvement over the old approach to workload management in CMS which involved individual operators feeding requests into agents. This new approach allows for a system where individual WMAgents are transient and can be added or removed from the system as needed.

Ryu, S.↗

Topological data analysis of task-based fMRI data from experiments on schizophrenia

We use methods from computational algebraic topology to study functional brain networks, in which nodes represent brain regions and weighted edges represent similarity of fMRI time series from each region. With these tools, which allow one to characterize topological invariants such as loops in high-dimensional data, we are able to gain understanding into low-dimensional structures in networks in a way that complements traditional approaches based on pairwise interactions. In the present paper, we analyze networks constructed from task-based fMRI data from schizophrenia patients, healthy controls, and healthy siblings of schizophrenia patients using persistent homology, which allows us to explore the persistence of topological structures such as loops at different scales in the networks. We use persistence landscapes, persistence images, and Betti curves to create output summaries from our persistent-homology calculations, and we study the persistence landscapes and images using k-means clustering and community detection. Based on our analysis of persistence landscapes, we find that the members of the sibling cohort have topological features (specifically, their 1-dimensional loops) that are distinct from the other two cohorts. From the persistence images, we are able to distinguish all three subject groups and to determine the brain regions in the loops (with four or more edges) that allow us to make these distinctions.

60 APPLIED LIFE SCIENCES↗

BioADAPT-MRC: adversarial learning-based domain adaptation improves biomedical machine reading comprehension task

ABSTRACT Motivation Biomedical machine reading comprehension (biomedical-MRC) aims to comprehend complex biomedical narratives and assist healthcare professionals in retrieving information from them. The high performance of modern neural network-based MRC systems depends on high-quality, large-scale, human-annotated training datasets. In the biomedical domain, a crucial challenge in creating such datasets is the requirement for domain knowledge, inducing the scarcity of labeled data and the need for transfer learning from the labeled general-purpose (source) domain to the biomedical (target) domain. However, there is a discrepancy in marginal distributions between the general-purpose and biomedical domains due to the variances in topics. Therefore, direct-transferring of learned representations from a model trained on a general-purpose domain to the biomedical domain can hurt the model’s performance. Results We present an adversarial learning-based domain adaptation framework for the biomedical machine reading comprehension task (BioADAPT-MRC), a neural network-based method to address the discrepancies in the marginal distributions between the general and biomedical domain datasets. BioADAPT-MRC relaxes the need for generating pseudo labels for training a well-performing biomedical-MRC model. We extensively evaluate the performance of BioADAPT-MRC by comparing it with the best existing methods on three widely used benchmark biomedical-MRC datasets—BioASQ-7b, BioASQ-8b and BioASQ-9b. Our results suggest that without using any synthetic or human-annotated data from the biomedical domain, BioADAPT-MRC can achieve state-of-the-art performance on these datasets. Availability and implementation BioADAPT-MRC is freely available as an open-source project at https://github.com/mmahbub/BioADAPT-MRC. Supplementary information Supplementary data are available at Bioinformatics online.

60 APPLIED LIFE SCIENCES↗

Integrating External Resources with a Task-Based Programming Model

Accessing external resources (e.g., loading input data, checkpointing snapshots, and out-of-core processing) can have a significant impact on the performance of supercomputer applications. However, no existing programming systems for high-performance computing directly manage and optimize these external accesses. As a result, users must explicitly manage external accesses alongside their computation at the application level, which can result in both correctness and performance issues. We address this limitation by introducing Iris, a task-based programming model with semantics for external resources. Iris allows applications to describe their access requirements to external resources and the relationship of those accesses to the computation. Iris incorporates external I/O into a deferred execution model, reschedules external I/O to overlap I/O with computation, and reduces external I/O when possible. We evaluate Iris on three microbenchmarks representative of important workloads in HPC and a full combustion simulation, S3D. We demonstrate that the Iris implementation of S3D reduces the external I/O overhead by up to 20×, compared to the Legion and the Fortran implementations.

97 MATHEMATICS AND COMPUTING↗

Lamellar: A Rust-based Asynchronous Tasking and PGAS Runtime for High Performance Computing

Cybersecurity is one of the largest concerns in modern computing, impacting and dictating how governments, private corporations, and individuals interact with and live in an increasingly digital world. The NSA has recently released a memo [ 1] on “Software Memory Safety” where they highlight that both Microsoft and Google have stated around 70% of software vulnerabilities were due to memory safety issues. Although languages such as C and C++ provide freedom and flexibility with memory management, guaran- teeing safety falls mostly on the developer. The NSA recommends using “memory safe” languages whenever possible. In this paper we introduce Lamellar, an asynchronous tasking and PGAS HPC runtime written in Rust, one such "memory safe" language. We describe the entire Lamellar stack, from network interfaces to high- level abstractions such as distributed LamellarArrays and Active Messages. We conclude by showing comparable performance to legacy PGAS runtimes (e.g. OpenSHMEM) on a subset of the BALE kernel suite while maintaining strong memory safety principles.

HPC Software Systems, Rust Programming Language, P↗

CoreTSAR: Core Task-Size Adapting Runtime

Heterogeneity continues to increase at all levels of computing, with the rise of accelerators such as GPUs, FPGAs, and other co-processors into everything from desktops to supercomputers. As a consequence, efficiently managing such disparate resources has become increasingly complex. CoreTSAR seeks to reduce this complexity by adaptively worksharing parallel-loop regions across compute resources without requiring any transformation of the code within the loop. Lastly, our results show performance improvements of up to three-fold over a current state-of-the-art heterogeneous task scheduler as well as linear performance scaling from a single GPU to four GPUs for many codes. In addition, CoreTSAR demonstrates a robust ability to adapt to both a variety of workloads and underlying system configurations.

97 MATHEMATICS AND COMPUTING↗

Offshore Code Comparison Collaboration, Continuation within IEA Wind Task 30: Phase II Results Regarding a Floating Semisubmersible Wind System: Preprint

Offshore wind turbines are designed and analyzed using comprehensive simulation tools (or codes) that account for the coupled dynamics of the wind inflow, aerodynamics, elasticity, and controls of the turbine, along with the incident waves, sea current, hydrodynamics, and foundation dynamics of the support structure. This paper describes the latest findings of the code-to-code verification activities of the Offshore Code Comparison Collaboration, Continuation (OC4) project, which operates under the International Energy Agency (IEA) Wind Task 30. In the latest phase of the project, participants used an assortment of simulation codes to model the coupled dynamic response of a 5-MW wind turbine installed on a floating semisubmersible in 200 m of water. Code predictions were compared from load-case simulations selected to test different model features. The comparisons have resulted in a greater understanding of offshore floating wind turbine dynamics and modeling techniques, and better knowledge of the validity of various approximations. The lessons learned from this exercise have improved the participants? codes, thus improving the standard of offshore wind turbine modeling.

17 WIND ENERGY↗

AAPM Task Group 128: Quality assurance tests for prostate brachytherapy ultrasound systems

While ultrasound guided prostate brachytherapy has gained wide acceptance as a primary treatment tool for prostate cancer, quality assurance of the ultrasound guidance system has received very little attention. Task Group 128 of the American Association of Physicists in Medicine was created to address quality assurance requirements specific to transrectal ultrasound used for guidance of prostate brachytherapy. Accurate imaging guidance and dosimetry calculation depend upon the quality and accuracy of the ultrasound image. Therefore, a robust quality assurance program for the ultrasound system is essential. A brief review of prostate brachytherapy and ultrasound physics is provided, followed by a recommendation for elements to be included in a comprehensive test phantom. Specific test recommendations are presented, covering grayscale visibility, depth of penetration, axial and lateral resolution, distance measurement, area measurement, volume measurement, needle template/electronic grid alignment, and geometric consistency with the treatment planning computer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IMRT commissioning: Multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119

AAPM Task Group 119 has produced quantitative confidence limits as baseline expectation values for IMRT commissioning. A set of test cases was developed to assess the overall accuracy of planning and delivery of IMRT treatments. Each test uses contours of targets and avoidance structures drawn within rectangular phantoms. These tests were planned, delivered, measured, and analyzed by nine facilities using a variety of IMRT planning and delivery systems. Each facility had passed the Radiological Physics Center credentialing tests for IMRT. The agreement between the planned and measured doses was determined using ion chamber dosimetry in high and low dose regions, film dosimetry on coronal planes in the phantom with all fields delivered, and planar dosimetry for each field measured perpendicular to the central axis. The planar dose distributions were assessed using gamma criteria of 3%/3 mm. The mean values and standard deviations were used to develop confidence limits for the test results using the concept confidence limit=|mean|+1.96{sigma}. Other facilities can use the test protocol and results as a basis for comparison to this group. Locally derived confidence limits that substantially exceed these baseline values may indicate the need for improved IMRT commissioning.

61 RADIATION PROTECTION AND DOSIMETRY↗

A statistical, task-based evaluation method for three-dimensional x-ray breast imaging systems using variable-background phantoms

Purpose: For the last few years, development and optimization of three-dimensional (3D) x-ray breast imaging systems, such as digital breast tomosynthesis (DBT) and computed tomography, have drawn much attention from the medical imaging community, either academia or industry. However, there is still much room for understanding how to best optimize and evaluate the devices over a large space of many different system parameters and geometries. Current evaluation methods, which work well for 2D systems, do not incorporate the depth information from the 3D imaging systems. Therefore, it is critical to develop a statistically sound evaluation method to investigate the usefulness of inclusion of depth and background-variability information into the assessment and optimization of the 3D systems. Methods: In this paper, we present a mathematical framework for a statistical assessment of planar and 3D x-ray breast imaging systems. Our method is based on statistical decision theory, in particular, making use of the ideal linear observer called the Hotelling observer. We also present a physical phantom that consists of spheres of different sizes and materials for producing an ensemble of randomly varying backgrounds to be imaged for a given patient class. Lastly, we demonstrate our evaluation method in comparing laboratory mammography and three-angle DBT systems for signal detection tasks using the phantom's projection data. We compare the variable phantom case to that of a phantom of the same dimensions filled with water, which we call the uniform phantom, based on the performance of the Hotelling observer as a function of signal size and intensity. Results: Detectability trends calculated using the variable and uniform phantom methods are different from each other for both mammography and DBT systems. Conclusions: Our results indicate that measuring the system's detection performance with consideration of background variability may lead to differences in system performance estimates and comparisons. For the assessment of 3D systems, to accurately determine trade offs between image quality and radiation dose, it is critical to incorporate randomness arising from the imaging chain including background variability into system performance calculations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Verification of monitor unit calculations for non-IMRT clinical radiotherapy: Report of AAPM Task Group 114

The requirement of an independent verification of the monitor units (MU) or time calculated to deliver the prescribed dose to a patient has been a mainstay of radiation oncology quality assurance. The need for and value of such a verification was obvious when calculations were performed by hand using look-up tables, and the verification was achieved by a second person independently repeating the calculation. However, in a modern clinic using CT/MR/PET simulation, computerized 3D treatment planning, heterogeneity corrections, and complex calculation algorithms such as convolution/superposition and Monte Carlo, the purpose of and methodology for the MU verification have come into question. In addition, since the verification is often performed using a simpler geometrical model and calculation algorithm than the primary calculation, exact or almost exact agreement between the two can no longer be expected. Guidelines are needed to help the physicist set clinically reasonable action levels for agreement. This report addresses the following charges of the task group: (1) To re-evaluate the purpose and methods of the ''independent second check'' for monitor unit calculations for non-IMRT radiation treatment in light of the complexities of modern-day treatment planning. (2) To present recommendations on how to perform verification of monitor unit calculations in a modern clinic. (3) To provide recommendations on establishing action levels for agreement between primary calculations and verification, and to provide guidance in addressing discrepancies outside the action levels. These recommendations are to be used as guidelines only and shall not be interpreted as requirements.

60 APPLIED LIFE SCIENCES↗

An analysis of confidence limit calculations used in AAPM Task Group No. 119

Purpose: The report issued by AAPM Task Group No. 119 outlined a procedure for evaluating the effectiveness of IMRT commissioning. The procedure involves measuring gamma pass-rate indices for IMRT plans of standard phantoms and determining if the results fall within a confidence limit set by assuming normally distributed data. As stated in the TG report, the assumption of normally distributed gamma pass rates is a convenient approximation for commissioning purposes, but may not accurately describe the data. Here the authors attempt to better describe gamma pass-rate data by fitting it to different distributions. The authors then calculate updated confidence limits using those distributions and compare them to those derived using TG No. 119 method. Methods: Gamma pass-rate data from 111 head and neck patients are fitted using the TG No. 119 normal distribution, a truncated normal distribution, and a Weibull distribution. Confidence limits to 95% are calculated for each and compared. A more general analysis of the expected differences between the TG No. 119 method of determining confidence limits and a more time-consuming curve fitting method is performed. Results: The TG No. 119 standard normal distribution does not fit the measured data. However, due to the small range of measured data points, the inaccuracy of the fit has only a small effect on the final value of the confidence limits. The confidence limits for the 111 patient plans are within 0.1% of each other for all distributions. The maximum expected difference in confidence limits, calculated using TG No. 119's approximation and a truncated distribution, is 1.2%. Conclusions: A three-parameter Weibull probability distribution more accurately fits the clinical gamma index pass-rate data than the normal distribution adopted by TG No. 119. However, the sensitivity of the confidence limit on distribution fit is low outside of exceptional circumstances.

60 APPLIED LIFE SCIENCES↗

Calculations of two new dose metrics proposed by AAPM Task Group 111 using the measurements with standard CT dosimetry phantoms

Purpose: AAPM Task Group 111 proposed to measure the equilibrium dose-pitch product D-caret{sub eq} for scan modes involving table translation and the midpoint dose D{sub L}(0) for stationary-table modes on the central and peripheral axes of sufficiently long (e.g., at least 40 cm) phantoms. This paper presents an alternative approach to calculate both metrics using the measurements of scanning the standard computed tomographic (CT) dosimetry phantoms on CT scanners.Methods: D-caret{sub eq} was calculated from CTDI{sub 100} and ε(CTDI{sub 100}) (CTDI{sub 100} efficiency), and D{sub L}(0) was calculated from D-caret{sub eq} and the approach to equilibrium function H(L) =D{sub L}(0)/D{sub eq}, where D{sub eq} was the equilibrium dose. CTDI{sub 100} may be directly obtained from several sources (such as medical physicist's CT scanner performance evaluation or the IMPACT CT patient dosimetry calculator), or be derived from CTDI{sub Vol} using the central to peripheral CTDI{sub 100} ratio (R{sub 100}). The authors have provided the required ε(CTDI{sub 100}) and H(L) data in two previous papers [X. Li, D. Zhang, and B. Liu, Med. Phys. 39, 901–905 (2012); and ibid. 40, 031903 (10pp.) (2013)]. R{sub 100} was assessed for a series of GE, Siemens, Philips, and Toshiba CT scanners with multiple settings of scan field of view, tube voltage, and bowtie filter.Results: The calculated D{sub L}(0) and D{sub L}(0)/D{sub eq} in PMMA and water cylinders were consistent with the measurements on two GE CT scanners (LightSpeed 16 and VCT) by Dixon and Ballard [Med. Phys. 34, 3399–3413 (2007)], the measurements on a Siemens CT scanner (SOMATOM Spirit Power) by Descamps et al. [J. Appl. Clin. Med. Phys. 13, 293–302 (2012)], and the Monte Carlo simulations by Boone [Med. Phys. 36, 4547–4554 (2009)].Conclusions: D-caret{sub eq} and D{sub L}(0) can be calculated using the alternative approach. The authors have provided the required ε(CTDI{sub 100}) and H(L) data in two previous papers. R{sub 100} is presented for a majority of multidetector CT scanners currently on the market, and can be easily assessed for other CT scanners or operating conditions not covered in this study. The central to peripheral D{sub eq} ratio is about 1.50 and 1.12 times of R{sub 100} for the 32- and 16-cm diameter PMMA phantom, respectively.

61 RADIATION PROTECTION AND DOSIMETRY↗