Search NASA⌕ Search

SEARCH · Search NASA

Results for “techniques and instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Assessment of Readout Techniques for Passive Monitors

This fiscal year (FY) 2023 report on passive temperature sensors covers two main objectives: to demonstrate that the optical dilatometer can successfully process disc shaped silicon carbide (SiC) temperature monitors (TMs), and to demonstrate proof of concept for using the capacitance readout method to read printed melt wires. The SiC objective was successfully met by annealing and analyzing, via optical dilatometry, all eight 3-mm SiC discs provided by the Nuclear Science User Facilities (NSUF) Idaho State University (ISU) Nanostructured Steels for Enhanced Radiation Tolerance (N SERT) experiment, which was irradiated at Idaho National Laboratory (INL)’s Advanced Test Reactor (ATR). Per the ISU N SERT experiment, capsule 1 (KGT 3828 1 and KGT 3828-2) had a design temperature of 300°C +/- 50°C and an exposure of 2 dpa +/- 10%; capsule 2 (KGT 4600 and KGT 4609) had a design temperature of 300°C +/- 50°C and an exposure of 6 dpa +/- 10%; capsule 3 (KGT 4639 C and KGT 4639-D) had a design temperature of 500°C +/- 50°C and an exposure of 6 dpa +/- 10%; and capsule 4 (KGT 3841 3 and KGT 3841 4) had a design temperature of 500°C +/- 50°C and an exposure of 2 dpa +/- 10%. The target exposure rates, in dpa, are the neutron damage for various types of nanostructured steels. All but three SiC TMs (KGT 4600, KGT 4639 D, and KGT 3841 4) revealed averaged peak irradiation temperatures that fell within the design temperature ranges. The three SiC TMs that did not fall within the design temperatures ranges were at least 100°C below that target temperature. Furthermore, SiC TM KGT 3841 C revealed two irradiation regimes: one closer to the 300°C design temperature, and the other closer to the 500°C design temperature. Also, all the SiC TMs’ averaged peak irradiation temperatures came in anywhere between 20°C and 240°C below the irradiation temperatures predicted by the thermal models. This showed the optical dilatometry method to be a reliable and less time intensive process for determining averaged peak irradiation temperatures from passive SiC TMs such as rods and discs. Under the Advanced Sensors and Instrumentation (ASI) program in FY-23, Boise State University (BSU) proposed to demonstrate proof of concept for using a capacitance readout technique applicable to printed melt wires; however, they were stymied by the complexity of the capacitance readout method. In support of the BSU work, INL developed an additively manufactured (AM) ceramic package for encapsulating the new melt wires. Inks were synthesized at BSU that used new protocols rather than following previously established protocols implemented at INL, and testing of various temperatures was conducted at BSU to evaluate the melting behaviors of the printed melt wires. The result was that the capacitance readout technique showed promise but also created more challenges than originally anticipated. For example, the tin ink synthesized at BSU showed unusual melting behaviors that did nothing to enhance the performance of the final printed melt wire prototype in terms of the capacitance readout method. To make the proof of concept work when applied to the printed melt wires, the ASI program would need to invest further resources and time. Consequently, the program is not planning to continue this proof of concept work in FY-24, based on the progress and findings achieved in FY-23.

36 MATERIALS SCIENCE↗

Neutrons in Structural Biology: Challenges and Opportunities (Workshop Report)

Gaining a thorough understanding of biological systems requires building our knowledge about biological processes from the level of atoms and electrons, and up to whole organisms. Such comprehensive knowledge will allow for a predictive understanding of complex biological systems behavior. It will guide us in the design and development of novel therapeutics and vaccines to tackle existing health threats and to prepare for future pandemics, and it will provide information necessary to create new biomaterials and bio-inspired technologies through manipulation of biological macromolecules, their assemblies, single cells and even microorganisms. Reaching these goals will require a synergistic combination of multiple experimental techniques with molecular calculations and predictive simulations, and the design and development of new techniques and capabilities that bridge current knowledge and technology gaps. Neutron scattering provides unique information about the biomacromolecular structure and function and can play a major role in achieving these goals. A workshop was held to engage the scientific community in identifying pressing challenges in biochemistry, structural biology, enzymology and structure-guided drug design not solved with the current neutron scattering technologies or utilizing other structural biology techniques such as X-ray crystallography, NMR, and cryo-EM. The workshop brought together structural biology, biochemistry and computational experts, as well as early career researchers and students, creating a forum for discussing scientific advancement and collaboration. The workshop included a one-day satellite training workshop where graduate students and postdoctoral researchers were educated in the application of neutron crystallography and small-angle scattering in structural biology. Furthermore, the Instrument Scientific Advisory Board (ISAB) for the development of a macromolecular neutron diffractometer at ORNL’s Second Target Station was introduced at the workshop. The major outcome was that neutrons can provide atomic-level understanding of biomacromolecular structure, function and dynamics which is of paramount importance for addressing the identified challenges. Neutron crystallography, in particular, can resolve long-standing biochemical issues regarding enzyme function by delineating the underlying chemistry and can have a major impact on the design of small-molecule therapeutics, especially in combination with molecular computation (quantum chemistry and molecular dynamics simulations) and the emerging artificial intelligence (AI)-assisted drug design technologies. The unique properties of neutrons, including their high sensitivity to hydrogen and their non-destructive nature, make them ideal probes of biological matter. There is a palpable need in the scientific community to expand and enhance the impact of neutron sciences on biology. Neutron crystallography is the only structural biology method capable of determining positions of all hydrogen atoms in proteins, nucleic acids and their complexes at near-physiological temperatures and of unstable species at cryogenic temperatures. Moreover, neutron analysis is non-ionizing, non-destructive and does not perturb the structure or redox chemistry of active site metal centers and clusters in proteins, which can be invaluable for studying radiation-sensitive metalloprotein complexes. Further, neutron energies used in scattering applications are similar to atomic motions, permitting neutron spectroscopies to characterize the dynamics of biomacromolecules on the picosecond to microsecond timescales. The different sensitivities of neutrons to protium (H) and deuterium (D) isotopes of hydrogen allow enhanced visibility of specific parts of biological complexes through isotopic labeling. The impact of neutrons will be most powerful when neutron scattering is combined with complementary experimental techniques that use photons and electrons, and with high-performance computing. The interconnection and mutuality of the experimental and theoretical capabilities will drive discoveries in biological and health sciences to generate more complete picture of complex biological systems. The major limitation in the field of biological neutron crystallography has been signal-to-noise, demanding large samples that are difficult to produce for the majority of biomacromolecules and limiting the applicability of this technique in biological sciences. A neutron crystallography instrument at the Second Target Station will revolutionize biological science with neutrons by engaging a large scientific community of structural biologists, enabling successful neutron diffraction experiments from radically smaller biomacromolecular crystals, resolving unanswered biochemical questions, and meaningfully contributing to rational drug design. The meeting highlighted 10 grand challenges that will be addressed with this advanced capability over the next decade and beyond, and the recommendations required to help address them are given below.

59 BASIC BIOLOGICAL SCIENCES↗

Feasibility and Prospects of the High Resolution Rapid Refresh Model For Dynamic Line Rating

The ampacity of transmission lines is defined as the maximum amount of current the conductor can safely carry. It is necessary for transmission line operators to apply ampacity limits due to the thermal properties of the conductor. Dynamic Line Rating (DLR) is a technology and technique that uses the environmental conditions or a set of the conditions to calculate the ampacity of the conductor. The way the DLR is calculated has depended upon some amount of physical technology to implement the solution. The High Resolution Rapid Refresh (HRRR) Model is an atmospheric model that may provide enough resolution to perform dynamic line rating without any hardware at all. The objective is to use this model to perform Dynamic Line Rating. This will solve two of the most pervasive problems in Dynamic Line Rating, how to instrument a transmission line hundreds of miles long and then how to predict near future ampacity sufficient for transmission operators to effectively use, This technique will use the Idaho National Laboratory site as the test location for analysis. The High Resolution Rapid Refresh model is a reliable, freely available, and well-maintained weather forecasting model for the entire United States of America. The model provides enough special resolution that additional local weather monitoring devices at location are not necessary to conduct dynamic line rating. The HRRR ratings are lower on average than the locally measured ratings which allows for an additional margin of safety. The adoption of using purely digital methods for dynamic line rating could allow for wide scale adoption of the technology with very little overhead expenditure of implementation.

17 WIND ENERGY↗

Dynamic separation of gases using microsieves

Separation of light weight molecules, such as nitrogen, argon, and oxygen, from heavier compounds can have significant impacts on energy capture, environmental monitoring, or isotopic applications. Large-scale gas separation techniques, like gas centrifugation and membrane mitigation, can be problematic as they impart tremendous energy and induce high mechanical stress onto the instrumentation. Microsieves, also known as micronozzles or microfunnels, are developed to create physical barriers to separate specific isotopes and gases. Separation is achieved using a converging and diverging micronozzle to impose supersonic gas flow around a curved wall, and it has been used for the separation of heavy actinide isotopes in low weight gas as well as separation of low weight gas compositions of nitrogen and argon back in 1900s. However, systematic reviews of this unique technology are lacking. The application of the Laval style nozzle, which has a converging/diverging entrance fundamental to the micronozzle, is included in this review due to its importance in industrial applications in uranium (U) isotope refinement. Using advanced computational fluid dynamic (CFD) simulations, the extent of gas separation can be modelled. Herein, we first examine the literature and survey recent advances on fabrication techniques for creating curved micronozzles, methods and separation principles used to design devices. Furthermore, we then follow with highlights of CFD simulations applied to evaluate the separation effects using microsieves. Finally, identification of the gap and recommendation for future development and applications are suggested for using intrinsic molecular features and fluidic dynamics in formulating separation strategies.

30 Microfluidics↗

BCARS Simulated Phantom Dataset for Evaluation of Processing Pipelines

Broadband coherent anti-Stokes Raman scattering (BCARS) microscopy is a powerful label-free biological imaging technique, but the raw signal requires careful processing. The vibrationally resonant (Raman) fingerprint signal is usually small compared with instrumental noise sources and the nonresonant background (NRB) inherent in the BCARS signal. Fortunately, the NRB exhibits a systematic phase relationship with the coherent Raman response, acting as a heterodyne amplifier for the weak fingerprint signal. Due to this heterodyne effect, the Raman response can be recovered quantitatively and invariantly across different instruments, provided the NRB shape is known. Even with heterodyne amplification, the amplitudes of fingerprint signal components are often comparable to system noise. Singular value decomposition (SVD), which utilizes spatial information, is often employed for additional noise filtering. Consequently, finding optimal processing parameters to properly distinguish the NRB and Raman responses and suppress noise in the complex BCARS signal requires a reference system that realistically represents the spectral and spatial properties of BCARS signals obtained from biological samples. We present a digital tissue phantom that meets these criteria as a tool for testing candidate signal processing pipelines. The digital phantom is generated with simulated hyperspectral Raman images having system-specific noise and background characteristics. Here, we analyze phantom datasets with differing background and signal-to-noise conditions to evaluate their impact on the performance of multiple signal processing pipelines. Specifically, we investigate the application of a Butterworth filter-based routine to directly estimate the NRB from the BCARS signal. Additionally, we evaluate a Lorentzian wavelet transform as an alternative to the Hilbert transform for extracting the Raman spectrum from the BCARS signal. While we demonstrate this phantom for BCARS, it can be used for any spectroscopic Raman imaging approach.

Dixon, Jessica Z. [Georgia Institute of Technology↗

High frequency beam oscillation keyhole dynamics in laser melting revealed by in-situ x-ray imaging

The metal additive manufacturing industry is actively developing instruments and strategies to enable higher productivity, optimal build quality, and controllable as-built microstructure. A beam controlling technique, laser oscillation has shown potential in all these aspects in laser welding; however, few attempts have been made to understand the underlying physics of the oscillating keyholes/melt pools which are the prerequisites for these strategies to become a useful tool for laser-based additive manufacturing processes. Here, to address this gap, we utilized a synchrotron-based X-ray operando technique to image the dynamic keyhole oscillation in Ti-6Al-4V using a miniature powder bed fusion setup. We found good agreement between the experimental observations and simulations performed with a validated Lattice Boltzmann multiphysics model. The study revealed the continuous and periodic fluctuations in the characteristic keyhole parameters that are unique to the oscillating laser beam processing and responsible for the chevron pattern formation at solidification. In particular, despite the intrinsic longer-range fluctuation, the oscillating technique displayed potential for reducing keyhole instability, mitigating porosity formation, and altering surface topology. These insights on the oscillating keyhole dynamics can be useful for the future development and application of this technique.

36 MATERIALS SCIENCE↗

Exploring Autoencoder-based Error-bounded Compression for Scientific Data

Error-bounded lossy compression is becoming an indispensable technique for the success of today's scientific projects with vast volumes of data produced during the simulations or instrument data acquisitions. Not only can it significantly reduce data size, but it also can control the compression errors based on user-specified error bounds. Autoencoder (AE) models have been widely used in image compression, but few AE-based compression approaches support error-bounding features, which are highly required by scientific applications. To address this issue, we explore using convolutional autoencoders to improve error-bounded lossy compression for scientific data, with the following three key contributions. (1) We provide an in-depth investigation of the characteristics of various autoencoder models and develop an error-bounded autoencoder-based framework in terms of the SZ model. (2) We optimize the compression quality for main stages in our designed AE-based error-bounded compression framework, fine-tuning the block sizes and latent sizes and also optimizing the compression efficiency of latent vectors. (3) We evaluate our proposed solution using five real-world scientific datasets and comparing them with six other related works. Experiments show that our solution exhibits a very competitive compression quality from among all the compressors in our tests. In absolute terms, it can obtain a much better compression quality (100%similar to 800% improvement in compression ratio with the same data distortion) compared with SZ2.1 and ZFP in cases with a high compression ratio.

Liu, Jinyang↗

Research in Dark Energy

This is the final report for the project aimed at developing techniques and understanding experimental data within the context of theoretical models, expressly in support of the Dark Energy Spectroscopic Instrument (DESI).

79 ASTRONOMY AND ASTROPHYSICS↗

Start-up Operation Experience with a Liquid Fluoride Salt Forced Convection Loop

A liquid fluoride salt forced convection test loop was constructed at Oak Ridge National Laboratory. Its unique features include a pebble bed test section, high-temperature instrumentation, a noncontact rotating gas seal for the pump, a silicon carbide flow tube, and a unique inductive heating technique. Initial startup and shake-down testing has been completed. This paper describes how several of the systems performed, highlights those that worked well, and discusses issues that arose during the start-up process. This discussion should be of interest to those who intend to develop molten salt technologies and who are interested in some of the specific techniques used in this experiment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Hyperspectral x-ray imaging mapping capabilities for nuclear forensics

Nuclear forensics relies on the integration of complementary signatures to constrain the origins and history of materials. Outcomes benefit from the timeliness and precision of the disparate methods that form typical analysis chains. Sample forms are often either minute in quantity or contain signatures like morphology or composition heterogeneity encoded on a microscale, so many analysis techniques focus on resolving signatures on ever-smaller length scales. The new hyperspectral x-ray imaging (HXI) instrument developed at Los Alamos National Laboratory seeks to improve the information available from scanning electron microscopy (SEM) x-ray spectrum analysis through superior spectral energy resolution vs. typical energy dispersive spectroscopy (EDS) systems in common use in nuclear forensics and other microanalysis fields. Based on arrays of transition-edge sensor (TES) microcalorimeter detectors, this instrument achieves a typical energy resolution of 7 eV full-width at half-maximum (FWHM) at 2 keV, opening new possibilities in trace element detection/analysis and chemical state determination through spectral shape shifts. We present here some of the first applications of the HXI instrument to actinide samples and discuss potential maturation of this nascent technology for future analysis pipelines.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Collection, release, and detection of analytes with polymer composite sampling materials

A unique fiber core sampler composition, related systems, and techniques for designing, making, and using the same are described. The sampler is used to interface with existing field instrumentation, such as Ion Mobility Spectrometer (IMS) equipment. Desired sampler characteristics include its: stiffness/flexibility; thermal mass and conductivity; specific heat; trace substance collection/release dependability, sensitivity and repeatability; thickness; reusability; durability; stability for thermal cleaning; and the like. In one form the sampler has a glass fiber core with a thickness less than 0.3 millimeter that is coated with a polymer including one or more of: polymeric organofluorine, polyimide, polyamide, PolyBenzlmidazole (PBI), PolyDiMethylSiloxane (PDMS), sulfonated tetrafluoroethylene (PFSA) and Poly(2,6-diphenyl-p-phenylene Oxide) (PPPO). Multiple polymer coatings with the same or different polymer types may be included, core/substrate surface functionalization utilized, and/or the core/substrate may be at partially filled with thermally conductive particles.

Addleman, Raymond S.↗

Binary pseudo-random array standards for calibration of 3D optical surface profilers used for metrology with significantly curved x-ray optics

High-accuracy metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate X-ray light with nanometer-scale wavelengths. The current capabilities and possibility for improvements in X-ray mirror manufacturing are limited by inherent imperfections of the integrated metrology tools. In the case of Fizeau interferometry, metrology tools are currently calibrated with super-polished flat test-standard/reference mirrors. This is acceptable for measuring slightly curved X-ray optics. However, for even moderately curved aspherical X-ray mirrors the flat-reference calibration is not sufficiently accurate and stitching Fizeau interferometer-based surface metrology is used to mitigate the problem. But still, the retrace and aberration errors, as well as the limited spatial resolution, described with the instrument transfer function (ITF), can be transferred into the optical surface topography of X-ray mirrors obtained in stitching metrology. For ITF calibration, we have developed an original technique, based on test standards structured as two-dimensional (2D) highly-randomized (HR) binary pseudo-random arrays (BPRAs). The technique employs the unique properties of the HR BPRA patterns in the spatial frequency domain., i.e. the inherent 2D power spectral density of the HR BPRA pattern has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range and field-of-view of an instrument. Here, we explore technological, metrological, and analytical aspects essential for calibration of the retrace and aberration errors of Fizeau interferometers using different types of tilted test samples, including a super-polished reference mirror for the re-trace calibration and the uniformly redundant array (URA) BPRA standards for the geometrical distortion (aberration) calibration. While the first method was previously demonstrated by researchers at DIAMOND Light Source, a method based on the URA BPRA is described and demonstrated here for the first time. We outline the design and fabrication process used in fabrication of URA BPRA test standards, and present the results of application of the URA BPRA standards demonstrating the high efficacy of our approach to geometrical distortion calibration of Fizeau interferometers. We also discuss the possible sources of unexpected peculiarities of the systematic errors, including an astigmatic character of the retrace error, observed with Fizeau interferometers at the Advanced Light Source X-Ray Optics Laboratory.

Munechika, Keiko↗

Data Compression in the NEXT-100 Data Acquisition System

NEXT collaboration detectors are based on energy measured by an array of photomultipliers (PMT) and topological event filtering based on an array of silicon photomultipliers (SiPMs). The readout of the PMT sensors for low-frequency noise effects and detector safety issues requires a grounded cathode connection that makes the readout AC-couple with variations in the signal baseline. Strict detector requirements of energy resolution better than 1% FWHM require a precise baseline reconstruction that is performed offline for data analysis and detector performance characterization. Baseline variations make it inefficient to apply traditional lossy data compression techniques, such as zero-suppression, that help to minimize data throughput and, therefore, the dead time of the system. However, for the readout of the SiPM sensors with less demanding requirements in terms of accuracy, a traditional zero-suppression is currently applied with a configuration that allows for a compression ratio of around 71%. The third stage in the NEXT detectors program, the NEXT-100 detector, is a 100 kg detector that instruments approximately five times more PMT sensors and twice the number of SiPM sensors than its predecessor, the NEXT-White detector, putting more pressure in the DAQ throughput, expected to be over 900 MB/s with the current configuration, which will worsen the dead time of the acquisition data system. This paper describes the data compression techniques applied to the sensor data in the NEXT-100 detector, which reduces data throughput and minimizes dead time while maintaining the event rate to the level of its predecessor, around 50 Hz.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Energy-resolved fast-neutron radiography using an event-mode neutron imaging detector

Energy-resolved fast-neutron radiography is a powerful non-destructive technique that can be used to remotely measure the quantity and distribution of elements and isotopes in a sample. This is done by comparing the energy-dependent neutron transmission of a sample with the known cross-sections of individual isotopes. The reconstruction of the composition is possible due to the unique features (e.g. resonances) in the cross-sections of individual isotopes. At short-pulsed (≲ 1 ns) neutron sources, such information is accessible via time-of-flight neutron imaging in principle, but requires a detector with nanosecond temporal resolution. Conventional neutron detectors can meet this requirement only by heavily compromising spatial resolution or efficiency. Here, we present a unique approach on fast neutron resonance radiography using a scintillator-based event-mode imaging detector at a short-pulsed neutron source, including first results on spatially mapped resonance profiles using MeV neutrons. The event mode approach applied in the presented detector allows recording of individual neutron interactions with nanosecond precision in time and sub-mm resolution in space. As a result, the entire available neutron energy spectrum can be measured for each pulse. At the same time, the use of a thick scintillator screen and lenses to focus the produced light results in a highly flexible field of view and a high interaction probability in the sensitive volume of the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A rapid heating and high magnetic field thermal analysis technique

Abstract A new thermal analysis technique is described that allows measurements to be performed on bulk samples at extreme heating and cooling rates and in high magnetic fields. High heating rates, up to 1000 °C min −1 , are achieved through electromagnetic induction heating of a custom-built apparatus fitted with commercial thermal analysis heads and sensor. Rapid cooling rates, up to 100 °C min −1 , are enabled by gas quenching and the small thermal mass of the induction furnace. The custom apparatus is designed to fit inside a superconducting magnet capable of fields up to 9 Tesla. This study demonstrates that the instrument is capable of collecting accurate thermal analysis data in high magnetic fields and rapidly acquiring data for dynamic processes. While the full potential of the technique is still unrealized, currently, it can provide insight into phenomena at time scales relevant to heat treatment in many industrial processes and into little understood effects of high magnetic field processing.

47 OTHER INSTRUMENTATION↗

New capability for neutron transmission measurements at LANSCE: The DICER instrument

A new capability for neutron transmission measurements has been developed at the Los Alamos Neutron Science Center (LANSCE). The DICER (Device for Indirect Capture Experiments on Radionuclides) instrument is designed to tightly constrain neutron-capture cross sections for short-lived radionuclides that are beyond the reach of direct techniques, via measurement and analysis of neutron transmission resonances on these same radionuclides. The innovative DICER apparatus enables simultaneous sample-in and sample-out measurements, thus minimizing the amount of sample material needed and reducing the measurements time by half. A description of the current status of the new transmission station, along with a performance overview and results from known reactions, will be presented here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feasibility of using thermal response methods for nonintrusive compressed air flow measurement

Robust, low-cost nonintrusive flow meters are of interest in many industries. Particularly, a reliable nonintrusive flow measurement for the diagnosis of air leaks in compressed air systems is desirable. Measurement of the air flow due to leaks in the system ensures an accurate estimation of potential cost and energy savings. This study evaluates a novel method of using thermal responses to nonintrusively measure leakage rates in compressed air lines. The method uses heat and the resulting thermal response to calculate the flow rate inside the compressed air line. Compared to the current methods for flow measurement, this method can simplify flow measurement while decreasing the sensitivity to errors when measuring flow rates. In this study, the methodology of the proposed method is explained along with the potential advantages to the design. Two approaches are evaluated: a dynamic step response and sinusoidal frequency response. Simulated tests evaluate the feasibility of the proposed methods, followed by experiments that validate the simulation results. A clear correlation between the thermal step response and the flow rate indicate viability of the proposed method in simulation. Experimental results yielded similar results, confirming the validity of the proposed method. The results of a field test in an industrial environment demonstrate the capability of the approach to other flow rate measurement techniques.

42 ENGINEERING↗

Improvements of pre-emptive identification of particle accelerator failures using binary classifiers and dimensionality reduction

In this paper we look at the properties of the Spallation Neutron Source (SNS) Differential Beam Current Monitor (DCM) data and various methods of data transformation to improve pre-emptive detection of machine trips. In this study, the foundation of the approach is the analysis of new underlying data and understanding various properties with the goal of faster classification, higher precision and higher recall with the aim to reduce false positives as low as required. The result of the research presented in this paper are a binary classifier capable of predicting accelerator failures with millisecond classification time, 96% precision, 58% true positive and 0% false positive rate and optimization techniques enabling real-time implementations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗