Structure and tensile strength of LaS(1.4)
The tensile strength of LaS(1.4) has been estimated by diametral stress testing at room temperature, 800 and 1300 K. Brittle, tensile-type failures were obtained at all temperatures when the crosshead speed was 0.0021 mm/s; however, a 1300 K test at 0.00085 mm/s produced plastic flow. The microstructure of LaS(1.4) consisted of two phases with beta-La2S3 comprising about 15 vol percent of the structure and gamma-La2S3 the remainder. Because of the limited amount of material available for testing, no correlation between microstructure and mechanical strength could be drawn.