Search NASA⌕ Search

SEARCH · Search NASA

Results for “GAMMA CAMERAS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Feasibility Testing of Delayed Scintillator Screens for Indirect Digital Neutron Radiography of Irradiated Nuclear Fuel

Neutron radiography provides information about the internal condition of irradiated nuclear fuels. Traditionally, neutron radiography of highly radioactive irradiated nuclear fuels has been done with film using indirect radiography methods.[1] While indirect film neutron radiography is insensitive to gamma radiation from radioactive samples, it is a time-consuming and labor-intensive process. Digital neutron radiography requires a fraction of the time to produce a neutron radiograph compared to film-based processes. However, electronic components of digital radiography systems can easily be damaged by gamma radiation, which typically precludes use of digital systems for examination of highly radioactive objects, though recent work has demonstrated that some digital neutron radiography systems can indeed directly examine such samples.[2,3] This paper describes experiments performed using a hybrid transfer-digital method with an activated scintillator screen that can record an image that is subsequently read by a digital camera. The screens used in this study use a dysprosium neutron converter that records a latent image in the form of activation while in a neutron beam, then is physically transported away from the beam and sample to a digital camera elsewhere to record the image while the activated dysprosium decays and the adjacent scintillator produces light from interactions with the decay radiation. This approach could accelerate radiographic examination of irradiated nuclear fuels compared to the current transfer method with film. Current indirect imaging infrastructure was modified and augmented with a digital system. A digital neutron radiograph of a highly-radioactive irradiated nuclear fuel pins was produced in ~20 minutes, which is a significant improvement compared to the current process that takes almost a full day to produce a radiograph.

99 GENERAL AND MISCELLANEOUS↗

Calculation of the nuclear material inventory in a sealed vault by 3D radiation mapping

The paper relates to the determination of the amount of nuclear material contained in a closed, concrete lined vault at the Aktau fast breeder reactor in Kazakhstan. This material had been disposed into the vault after examination in an experimental hot cell directly above the vault. In order to comply with IAEA Safeguards requirements it was necessary to determine the total quantities of nuclear materials - enriched uranium and plutonium - that were held with Kazakhstan. Although it was possible to determine the inventory of all of the accessible nuclear material - the quantity remaining in the vault was unknown. As part of the Global Threat Reduction Programme the UK Government funded a project to determine the inventory of these nuclear materials in this vault. This involved drilling three penetrations through the concrete lined roof of the vault; this enabled the placement of lights and a camera into the vault through two penetrations; while the third penetration enabled a lightweight manipulator arm to be introduced into the vault. This was used to provide a detailed 3D mapping of the dose rate within the vault and it also enabled the collection of samples for radionuclide analysis. The deconvolution of the 3D dose rate profile within the vault enabled the determination of the gamma emitting source distribution on the floor and walls of the vault. The samples were analysed to determine the fingerprint of those radionuclides producing the gamma dose - namely {sup 137}Cs and {sup 60}Co - to the nuclear materials. The combination of the dose rate source terms on the surfaces of the vault and the fingerprint then enabled the quantities of nuclear materials to be determined. The project was a major success and enabled the Kazakhstan Government to comply with IAEA Safeguards requirements. It also enabled the UK DECC Ministry to develop a technology of national (and international) use. Finally the technology was well received by IAEA Safeguards as an acceptable methodology for future studies. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The GSFC Advanced Compton Telescope (ACT)

A new telescope is being developed at GSFC for the study of point sources of gamma rays in the energy range 1-30 MeV. Using the detection principle of a Compton scatter in a 2.5 cm thick NaI(Tl) detector followed by absorption in a 15 cm thick NaI(Tl) detector, the telescope uses a rocking collimator for field-of-view reduction and background subtraction. Background reduction techniques include lead-plastic scintillator shielding, pulse shape discrimination and Anger camera operation to both NaI detectors, as well as a time-of-flight measurement between them. The instrument configuration and status is described.

Hartman, R.↗

The Structure and Tra c Flow Anatomy of the Planet-Scale Urban Vehicular Mobility

A data-driven realistic design and evalua- tion of vehicular mobility has been particularly chal- lenging due to a lack of large-scale real-world mea- surements in the research community. Current research methodologies rely on articial scenarios, random con- nectivity, and use small and biased samples. In this pa- per, we perform a combined study to learn the struc- ture and connectivity of urban streets and modeling and characterization of vehicular trac densities on them. Our dataset is a collection of more than 222 thousand routes and 25 million vehicular mobility images from 1091 online web cameras located in six dierent re- gions of the world. Our results centered around four major observations: i. study shows that driving routes and visiting locations of regions demonstrate power-law distribution, indicating a planned or recently designed road infrastructure; ii. we represent regions by network graphs in which nodes are camera locations and edges are urban streets that connect the nodes. Such represen- tation exhibits small world properties with short path lengths and large clustering coecient; iii. trac densi- ties show 80% temporal correlation during several hours of a day; iv. modeling trac densities against known theoretical distributions show less than 5% deviation for heavy-trailed models such as log-logistic and log- gamma distributions. We believe this work will provide a much-needed contribution to the research community for design and evaluation of future vehicular networks and smart cities.

Thakur, Gautam↗

THE RESOLVED NEAR-INFRARED EXTRAGALACTIC BACKGROUND

We present a current best estimate of the integrated near-infrared (NIR) extragalactic background light (EBL) attributable to resolved galaxies (Integrated Galaxy Light, IGL) in J, H, and K{sub s} . Our results for measurements of {nu}I{nu} in units of nW m{sup -2} sr{sup -1} are 11.7{sup +5.6}{sub -2.6} in J, 11.5{sup +4.5}{sub -1.5} in H, and 10.0{sup +2.8}{sub -0.8} in K{sub s} . We derive these new limits by combining our deep wide-field NIR photometry from five widely separated fields with other studies from the literature to create a galaxy counts sample that is highly complete and has good counting statistics out to JHK{sub s} {approx} 27-28. As part of this effort we present new ultra-deep K{sub s} -band galaxy counts from 22 hr of observations with the Multi Object Infrared Camera and Spectrograph (MOIRCS) instrument on the Subaru Telescope. We use this MOIRCS K{sub s} -band mosaic to estimate the total missing flux from sources beyond our detection limits. Our new limits to the NIR EBL are in basic agreement with, but 10%-20% higher than, previous estimates, bringing them into better agreement with estimates of the total NIR EBL (resolved + unresolved sources) obtained from TeV {gamma}-ray opacity measurements and recent direct measurements of the total NIR EBL as well as the modeled NIR IGL. We examine field-to-field variations in our photometry to show that the integrated light from galaxies is isotropic to within uncertainties, consistent with the expected large-scale isotropy of the EBL. Our data also allow for a robust estimate of the NIR light from Galactic stars, which we find to be 14.7 {+-} 2.4 in J, 10.1 {+-} 1.9 in H, and 7.6 {+-} 1.8 in K{sub s} in units of nW m{sup -2} sr{sup -1}.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-T-287: A Preliminary Study On Patient Specific VMAT Verification Using a Phosphor-Screen Based Geometric QA System (Raven QA)

Purpose: The RavenQA system (LAP Laser, Germany) is a QA device with a phosphor screen detector for performing the QA tasks of TG-142. This study tested if it is feasible to use the system for the patient specific QA of the Volumetric Modulated Arc Therapy (VMAT). Methods: Water equivalent material (5cm) is attached to the front of the detector plate of the RavenQA for dosimetry purpose. Then the plate is attached to the gantry to synchronize the movement between the detector and the gantry. Since the detector moves together with gantry, The ’Reset gantry to 0’ function of the Eclipse planning system (Varian, CA) is used to simulate the measurement situation when calculating dose of the detector plate. The same gantry setup is used when delivering the treatment beam for feasibility test purposes. Cumulative dose is acquired for each arc. The optical scatter component of each captured image from the CCD camera is corrected by deconvolving the 2D spatial invariant optical scatter kernel (OSK). We assume that the OSK is a 2D isotropic point spread function with inverse-squared decrease as a function of radius from the center. Results: Three cases of VMAT plans including head & neck, whole pelvis and abdomen-pelvis are tested. Setup time for measurements was less than 5 minutes. Passing rates of absolute gamma were 99.3, 98.2, 95.9 respectively for 3%/3mm criteria and 96.2, 97.1, 86.4 for 2%/2mm criteria. The abdomen-pelvis field has long treatment fields, 37cm, which are longer than the detector plate (25cm). This plan showed relatively lower passing rate than other plans. Conclusion: An algorithm for IMRT/VMAT verification using the RavenQA has been developed and tested. The model of spatially invariant OSK works well for deconvolution purpose. It is proved that the RavenQA can be used for the patient specific verification of VMAT. This work is funded in part by a Maryland Industrial Partnership Program grant to University of Maryland and to JPLC who owns the Raven technology. John Wong is a co-founder of JPLC.

60 APPLIED LIFE SCIENCES↗

Swift: A Gamma Ray Bursts Explorer

Swift is a NASA gamma-ray burst MIDEX mission that is in development for launch in December 2003. It is a multiwavelength transient observatory for GRB astronomy. The goals of the mission are to determine the origin of GRBs and their afterglows and use bursts to probe the early Universe. It will also.perform a survey of the hard X-ray sky to a sensitivity level of -1 mCrab. A wide-field camera will detect more than a hundred GRBs per year to 5 times fainter than BATSE. Sensitive narrow-field X-ray and UV/optical telescopes will be pointed at the burst location in 20 to 70 sec by an autonomously controlled 'swift' spacecraft. For each burst, arcsec positions will be determined and optical/UV/X-ray/gamma-ray spectrophotometry performed. Measurements of redshift will be made for many of the bursts. The instrumentation is a combination of superb existing flight-spare hardware and design from XMM and Spectrum-X/JET-X contributed by collaborators in the UK and Italy and development of a coded-aperture camera with a large-area (approximately 0.5 square meter) CdZnTe detector array. The hardware is currently in final stages of fabrication and initial stages of integration and test. Key components of the mission are vigorous follow-up and outreach programs to engage the astronomical community and public in Swift.

Gehrels, Neil↗

Explosive Transient Camera (ETC) Program

Since the inception of the ETC program, a wide range of new technologies was developed to support this astronomical instrument. The prototype unit was installed at ETC Site 1. The first partially automated observations were made and some major renovations were later added to the ETC hardware. The ETC was outfitted with new thermoelectrically-cooled CCD cameras and a sophisticated vacuum manifold, which, together, made the ETC a much more reliable unit than the prototype. The ETC instrumentation and building were placed under full computer control, allowing the ETC to operate as an automated, autonomous instrument with virtually no human intervention necessary. The first fully-automated operation of the ETC was performed, during which the ETC monitored the error region of the repeating soft gamma-ray burster SGR 1806-21.

Ricker, George↗

The GALILEO γ-ray array at the Legnaro National Laboratories

GALILEO, a new 4 pi high-resolution gamma-detection array, based on HPGe detectors, has been developed and installed at the Legnaro National Laboratories. The GALILEO array greatly benefits from a fully-digital readout chain, customized DAQ, and a variety of complementary detectors to improve the resolving power by the detection of particles, ions or high-energy gamma-ray transitions. In this paper, a full description of the array, including electronics and DAQ, is presented together with its complementary instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cervical SPECT Camera for Parathyroid Imaging

Primary hyperparathyroidism characterized by one or more enlarged parathyroid glands has become one of the most common endocrine diseases in the world affecting about 1 per 1000 in the United States. Standard treatment is highly invasive exploratory neck surgery called Parathyroidectomy. The surgery has a notable mortality rate because of the close proximity to vital structures. The move to minimally invasive parathyroidectomy is hampered by the lack of high resolution pre-surgical imaging techniques that can accurately localize the parathyroid with respect to surrounding structures. We propose to develop a dedicated ultra-high resolution (~ 1 mm) and high sensitivity (10x conventional camera) cervical scintigraphic imaging device. It will be based on a multiple pinhole-camera SPECT system comprising a novel solid state CZT detector that offers the required performance. The overall system will be configured to fit around the neck and comfortably image a patient.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ga:Ge array development

Work at the University of Arizona and at Lawrence Berkeley Laboratory on the development of a far infrared array camera for the Multiband Imaging Photometer on the Space Infrared Telescope Facility (SIRTF) is discussed. The camera design uses stacked linear arrays of Ge:Ga photoconductors to make a full two-dimensional array. Initial results from a 1 x 16 array using a thermally isolated J-FET readout are presented. Dark currents below 300 electrons s(exp -1) and readout noises of 60 electrons were attained. Operation of these types of detectors in an ionizing radiation environment are discussed. Results of radiation testing using both low energy gamma rays and protons are given. Work on advanced C-MOS cascode readouts that promise lower temperature operation and higher levels of performance than the current J-FET based devices is described.

Young, Erick T.↗

Evaluation of Low-cost, Full HD, CMOS Cameras for Use in the Calcine Retrieval Project - 19530

This paper describes results from radiation testing conducted on low-cost, commercial off-the-shelf, full high-definition (HD) resolution (1920 x 1080 p), complementary metal-oxide-semiconductor (CMOS) camera sensors. The purpose of the testing was to evaluate the sensors' suitability for use in the Calcine Retrieval Project by determining their image quality and life expectancy while operating in an ionizing radiation field of 20.0 Gy/h. The two camera sensors tested were the Axis FA1105 and Axis FA1125. These commercial camera sensors were designed for retail security surveillance and have no radiation-hardened (rad-hard) components. In addition to radiation testing, the sensors' field-of-view, resolution, and low-light image quality were tested at several target distances to ensure they meet project requirements. Testing was divided into two phases. During Phase 1, four FA1105 sensors and four FA1125 sensors were tested simultaneously without any shielding in radiation fields of 25.5 Gy/h and 49.3 Gy/h. In Phase 2, three FA1105 and five FA1125 sensors were shielded by 22.2 mm of lead and tested simultaneously in radiation fields of 26.8 Gy/h, 52.3 Gy/h, 143.0 Gy/h, 200.7 Gy/h, 404.6 Gy/h, and 2,317.5 Gy/h. Dose rate values were established using film dosimetry readings. Apertures in the shielding allowed for a 40-degree field of view while shielding all parts of the sensor except for directly in front of the CMOS sensor array. All testing was conducted at the Idaho Accelerator Center in Pocatello, Idaho, using a 450 keV X-ray generator. Sensor images were automatically captured at regular intervals throughout the testing for qualitative evaluation by the test team. Film dosimetry was placed near the sensors to record actual dose totals. The 450 keV setting generates X-ray radiation with an energy level close to the primary gamma energy level produced by the Cesium-137 isotope in the calcine, which is 662 keV. Results from Phase 1 indicate the sensors failed at an average cumulative dose of 226.3 Gy. For a given 20.0 Gy/h field this results in a mean time to failure (MTTF) of 11.3 hours. Recorded images from all sensors showed minimal image degradation due to radiation-induced noise. When the sensors finally failed, the failure mode was an abrupt loss of video. The image went black suggesting some other component in the sensor head besides the CMOS sensor array was responsible for the failure. During a portion of Phase 1 testing, a commercial, rad-hard camera was irradiated in the 25.5 Gy/h field along with the eight Axis FA series sensors. Image quality from the FA series sensors significantly outperformed the image quality of the rad-hard camera in radiation-induced noise tolerance, image resolution, and dynamic range. During Phase 2 testing, all sensors produced excellent images in radiation fields as high as 404.6 Gy/h. One FA1125 sensor was tested at the highest dose rate of 2,317.5 Gy/h. At this dose rate, the image was color shifted towards red and contained a significant amount radiation-induced noise. The sensor did not fail and was producing usable imagery after one hour, at which time the test was ended due to allotted beam-time at the test facility. Eighteen hours after X-rays were shut off, the sensor image returned to normal color and all eight sensors continued to operate without any visible, permanent image degradation. For Phase 2 testing, it was not possible to establish a MTTF since none of the shielded sensors failed during the allotted test time. However, given the highest cumulative dose of 4,142.1 Gy received by a shielded FA1125 sensor, a minimum life expectancy of 207 hours (8.6 days) is predicted while operating in a 20.0 Gy/h field. Test results indicate the radiation tolerance of the FA series sensor's CMOS array, along with the small form factor, full HD image quality, wide dynamic range, and Ethernet standard makes it suitable for short-term use in monitoring and visually documenting waste remediation efforts for the Calcine Retrieval Project at the INL. The sensor's low-cost of about $140 US, compared to commercial rad-hard cameras costing between $5,000 and $7,000 US each, allow them to be used as an affordable, disposable resource for many short-duration, radioactive waste remediation efforts where decontamination of an expensive, commercial rad-hard camera is undesirable or not possible. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

REAL-TIME DETECTION AND RAPID MULTIWAVELENGTH FOLLOW-UP OBSERVATIONS OF A HIGHLY SUBLUMINOUS TYPE II-P SUPERNOVA FROM THE PALOMAR TRANSIENT FACTORY SURVEY

The Palomar Transient Factory (PTF) is an optical wide-field variability survey carried out using a camera with a 7.8 deg{sup 2} field of view mounted on the 48 inch Oschin Schmidt telescope at Palomar Observatory. One of the key goals of this survey is to conduct high-cadence monitoring of the sky in order to detect optical transient sources shortly after they occur. Here, we describe the real-time capabilities of the PTF and our related rapid multiwavelength follow-up programs, extending from the radio to the {gamma}-ray bands. We present as a case study observations of the optical transient PTF10vdl (SN 2010id), revealed to be a very young core-collapse (Type II-P) supernova having a remarkably low luminosity. Our results demonstrate that the PTF now provides for optical transients the real-time discovery and rapid-response follow-up capabilities previously reserved only for high-energy transients like gamma-ray bursts.

79 ASTRONOMY AND ASTROPHYSICS↗

Hubble space telescope observations of the afterglow, supernova, and host galaxy associated with the extremely bright GRB 130427A

We present Hubble Space Telescope (HST) observations of the exceptionally bright and luminous Swift gamma-ray burst (GRB), GRB 130427A. At z = 0.34, this burst affords an excellent opportunity to study the supernova (SN) and host galaxy associated with an intrinsically extremely luminous burst (E {sub iso} > 10{sup 54} erg): more luminous than any previous GRB with a spectroscopically associated SN. We use the combination of the image quality, UV capability, and invariant point-spread function of HST to provide the best possible separation of the afterglow, host, and SN contributions to the observed light ∼17 rest-frame days after the burst, utilizing a host subtraction spectrum obtained one year later. Advanced Camera for Surveys grism observations show that the associated SN, SN 2013cq, has an overall spectral shape and luminosity similar to SN 1998bw (with a photospheric velocity, v {sub ph} ∼ 15, 000 km s{sup –1}). The positions of the bluer features are better matched by the higher velocity SN 2010bh (v {sub ph} ∼ 30, 000 km s{sup –1}), but this SN is significantly fainter and fails to reproduce the overall spectral shape, perhaps indicative of velocity structure in the ejecta. We find that the burst originated ∼4 kpc from the nucleus of a moderately star forming (1 M {sub ☉} yr{sup –1}), possibly interacting disk galaxy. The absolute magnitude, physical size, and morphology of this galaxy, as well as the location of the GRB within it, are also strikingly similar to those of GRB 980425/SN 1998bw. The similarity of the SNe and environment from both the most luminous and least luminous GRBs suggests that broadly similar progenitor stars can create GRBs across six orders of magnitude in isotropic energy.

79 ASTRONOMY AND ASTROPHYSICS↗

Photometric Observations of Supernova 2013cq Associated with GRB 130427A

We observed the afterglow of GRB 130427A with the Reionization and Transients Infrared Camera (RATIR) instrument on the 1.5 m Harold L. Johnson telescope of the Observatorio Astronómico Nacional in Sierra San Pedro Mártir. Our homogenous griZY JH photometry extends from the night of the burst to three years later. We fit a model for the afterglow. There is a significant positive residual that matches the behavior of SN 1998bw in the griZ filters; we suggest that this is a photometric signature of the supernova SN 2013cq associated with the Gamma-ray burst. The peak absolute magnitude of the supernova is M{sub r}=−18.43±0.11.

79 ASTRONOMY AND ASTROPHYSICS↗

A ROSAT Wide Field Camera search for XUV bursts

We have searched the ROSAT Wide Field Camera all-sky survey for shorttime-scale (less than 50 s) XUV bursts down to a limiting count of 5 x 10 exp -3 count/sq arcmin, corresponding to an incident flux of about 3 x 10 exp -10 erg/sq cm. In a total observation period of 171 d covering the entire sky, we found no evidence for such events. The present results are used to place limits on the log N-log S relation for gamma-ray bursts and constraints on the spectral shape of the previously reported ultrasoft X-ray transients.

Owens, Alan↗

The rapidly moving telescope - A progress report

A ground-based optical telescope system has been constructed with the capability to locate fast optical transients that may be associated with gamma-ray bursts (GRBs). The instrument has been integrated and operated during a shakedown period at GSFC, Maryland. Results of 35 hours of 'state mode' data are presented. The telescope has the proven capability to slew to any point on the night sky within 1.0 sec, track that position with better than one arcsecond stability, and image a 9 x 12 arcmin field of view with 1 arcsec angular resolution with 1.5 sec time resolution. The telescope-CCD camera system has a sensitivity of 13th magnitude for transients and 14th mag for field stars. In the 35 hr of operation many single frame transients of instrumental and optical origin have been observed; no two-sequential frame astrophysical transients have been identified. The combined rate of instrumental transients (predominantly sea-level muons) is 7.2/hr and of optical transients (satellite glints, airplane strobe lights, and meteors) is 5.1/hr. The RMT will operate in conjunction with the MIT Explosive Transient Camera survey instrument at Kitt Peak National Observatory, Tucson. The RMT is now being installed at Kitt Peak. Full operation will begin this summer.

Barthelmy, S. D.↗