Search NASA⌕ Search

SEARCH · Search NASA

Results for “Liquid helium”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Mass Driver Two - Cryogenic module

The cryogenic module of Mass Driver Two comprises a 3.25 inch (82.55 mm) OD bucket with two 44 kilo-ampere-turn coils made with .028 inch (.71 mm) diam niobium-titanium multi-filamentary cable in a copper matrix, impregnated with lead alloy for thermal inertia, as well as the service station to refrigerate, energize and eject the bucket. The station is housed in a six inch flanged pyrex cross which connects to the four inch pyrex tube of the mass driver itself. The bucket is refrigerated by being forced against a copper braid cradle attached to the bottom of a liquid helium reservoir which protrudes into the cross from above. The bucket is energized inductively by turning off two superconducting coils which are also attached to the helium reservoir, and which have maintained the correct flux linkage through the bucket coils during their cool-down through the critical temperature. Once charging is completed, the clamping pressure is released and the bucket is injected into the mass driver by means of two normal-conductor pulse coils surrounding the horizontal branches of the cross.

Fine, K.↗

A cryogenically-cooled, balloon-borne far infrared survey telescope

The design and performance of the Arizona cryogenically-cooled, balloon-borne, multiband far infrared survey telescope are described. The 40 cm Cassegrain telescope is completely contained in a liquid helium dewar. The focal plane array consists of Fabry optics and four detectors which each have a 12 arc minute field of view. Both photoconductive and bolometer detectors are utilized at effective wavelengths of 20, 80, 100 and 150 microns. In 1977 the telescope was used to make multicolor large scale maps of 70 square degrees in the Cygnus X region and the W3 region.

Campbell, M. F.↗

Magnetic shielding in a low temperature torsion pendulum experiment

A new type of ether drift experiment searches for anomalous torques on a permanent magnet. A torsion pendulum is used at liquid helium temperature, so that superconducting cylinders can be used to shield magnetic fields. Lead shields attenuate the earth's field, while Nb-Sn shields fastened to the pendulum contain the fields of the magnet. The paper describes the technique by which the earth's field can be reduced below 0.0001 G while simultaneously the moment of the magnet can be reduced by a factor 7 x 10 to the 4th.

Phillips, P. R.↗

High-acceleration mass drivers

High-acceleration mass drivers are discussed including the MD2 model of axial geometry, with individually powered drive coils of 13.1 cm diameter. Timing is derived through the interruption of light beams by the moving armature (bucket). Electric power is provided by the resonant discharge of sector capacitor banks through silicon-controlled rectifiers in a two-phase, quadrature circuit. The bucket flies in vacuum, guided by passive dynamic eddy-current magnetic forces, those currents flowing in strip conductors lining the inside of a nonconducting vacuum pipe. Quantitative measurements are obtained with a solid bucket carrying two superconducting coils with a current density of 25 kA/sq cm. A cryogenic station for cooling the bucket to liquid helium temperature is connected to the vacuum pipe.

Oneill, G. K.↗

Improved LEEM ranges over four decades

Low-energy electron magnetometer is suitable for terrestrial and aerial applications. Electron beam strikes tantalum collector plates in device, amplifying current and converting it to frequency. Current difference increases with beam deflection, providing measure of local field strength. LEEM operation requires no liquid helium unlike superconducting quantum interference device. LEEM sensitivity compares favorably with that of optical absorption magnetometers, and microsecond response range makes analyzing fast magnetic transients and signatures possible.

Singh, J. J.↗

Effects of hydrogen atom spin exchange collisions on atomic hydrogen maser oscillation frequency

Frequency shifts due to collisions between hydrogen atoms in an atomic hydrogen maser frequency standard are studied. Investigations of frequency shifts proportional to the spin exchange frequency shift cross section and those proportional to the duration of exchange collisions are discussed. The feasibility of operating a hydrogen frequency standard at liquid helium temperatures is examined.

Crampton, S. B.↗

Design Studies for a Far Infrared Absolute Spectrometer for the Cosmic Background Explorer

Unrelenting symmetry of design is required to assure the thermal balance of a cryogenically cooled, rapid scan interferometer spectrometer to be mounted in vacuum with the Cosmic Background Explorer liquid helium dewar. The instrument receives inputs from Winston cone optical flux collectors, one open to space and a second coupled to a black body reference source. A differential instrument, the spectrometer produces outputs corresponding to the Fourier transform of the spectral radiance difference between the two inputs. The two outputs are sensed by four detectors, two optimized for shorter wavelength response, and two optimized for longer wavelengths. The optical design, detector and signal channel, system sensitivity, mechanics, thermal control and cryogenics, electronics and power systems, command and control, calibration, system test requirements, and the instrument interface are discussed. Recommendations for continued work are indicated for the superconducting reflective horns, the motor bearing and drive, and design detail.

Johnson, N. J. E.↗

Atomic hydrogen storage method and apparatus

Atomic hydrogen, for use as a fuel or as an explosive, is stored in the presence of a strong magnetic field in exfoliated layered compounds such as molybdenum disulfide or an elemental layer material such as graphite. The compounds maintained at liquid helium temperatures and the atomic hydrogen is collected on the surfaces of the layered compound which are exposed during delamination (exfoliation). The strong magnetic field and the low temperature combine to prevent the atoms of hydrogen from recombining to form molecules.

Woollam, J. A.↗

The galactic center - 16-30 micron observations and the 18 micron extinction

Within the galactic center, ionized gas, stars, and heated dust are in close proximity to each other. Observations of the galactic center were made during two flight series on NASA aircraft flying at altitudes of more than 12 km. In both series the instrument used was a 10-channel liquid helium cooled grating spectrometer. Three 16-30 micrometers continuum spectra are presented along with two-color scans of the galactic center. No 18.71 micrometers line emission has been detected from Sgr A West. This is consistent with large dust extinction and normal S III/H II abundances. All three 16-30 micrometers continuum spectra show a broad depression centered at about 18 micrometers. This observation is attributed to absorption by cold silicate dust grains. The characteristics of a silicate model are discussed.

Mccarthy, J. F.↗

Solid State Circuits for Cryogenic Operation

Tests confirm operation of five commercial semiconductor devices at cryogenic temperatures. The five devices - one tunnel diode, one field-effect transistor, and three CMOS integrated circuits - all perform well in circuits immersed in liquid-helium bath. For some tests, bath temperature was reduced to 1,25K by pumping.

Petrac, D.↗

A study of optically contacted quartz at cryogenic temperatures

Optical contacting as a method of joining the quartz components of the instruments for the Gravity Probe-B experiment is evaluated. The strength of the bond between optically contacted fused quartz surfaces at liquid helium temperature was investigated. A test apparatus which can be used for making measurements of the tensile strength of these bonds was designed. Results of the tensile pull tests are given and the reliability of such bonds analyzed.

Payne, L. L.↗

Cryogenic masers

Various factors affecting the frequency stability of hydrogen masers are described and related to maser design parameters. The long-term frequency stability of a hydrogen maser is limited by the mechanical stability of the cavity, and the magnitudes of the wall relaxation, spin exchange, and recombination rates which affect the Q of the line. Magnetic resonance studies of hydrogen atoms at temperatures below 1 K and in containers coated with liquid helium films demonstrated that cryogenic masers may allow substantial improvements in all of these parameters. In particular the thermal expansion coefficients of most materials are negligible at 1 K. Spin exchange broadening is three orders of magnitude smaller at 1 K than at room temperature, and the recombination and wall relaxation rates are negligible at 0.52 K where the frequency shift due to the 4 He-coated walls of the container has a broad minimum as a function of temperature. Other advantages of the helium-cooled maser result from the high purity, homogeneity, and resilence of helium-film-coated walls and the natural compatibility of the apparatus with helium-cooled amplifiers.

Berlinsky, A. J.↗

An adiabatic demagnetization refrigerator for infrared bolometers

Adiabatic demagnetization refrigerators have been built and installed in small portable liquid helium cryostats to test the feasibility of this method of cooling infrared bolometric detectors to temperatures below 0.3 K. Performance has been achieved which suggests that bolometer temperatures of 0.2 K can be maintained for periods of approximately 60 hours. Applications to sensitive infrared detection from ground-based telescopes and space satellites are discussed. Design data are given which permit the evaluation of refrigerator performance for a variety of design parameters.

Britt, R. D.↗

Recent spectroscopic measurements of NOx in the lower stratosphere

High resolution (0.02 and 0.06 per cm) Fourier transform airborne systems were used for measurements of long path atmospheric absorption spectra, covering many of the NOx infrared bands. Atmospheric emission measurements with liquid helium cooled grating spectrometer systems at 0.5 per cm resolution were also carried out from different altitudes in the NOx bands region. Analysis of the absorption and emission spectra provides quantification of NOx in the lower stratosphere at different latitudes and seasons, as well as diurnal variability.

Goldman, A.↗

A cryogenic valve for spacecraft applications

Space-compatible cryogenic valves are now required to operate between room and liquid helium temperatures. A remotely controllable cryogenic valve is described, which is made of bellows-type stainless steel and is operated by a miniature dc motor with integral gearset (485:1) at a nominal voltage of 28 Vdc. The power transmission provides a further reduction of 7.2:1 to give an overall gear ratio of nearly 3500:1, assuring reliability of operation at low temperatures. Valve performance (leak rate) data are presented at LN2, LHe, and SfHe temperatures at delivered torques of 18, 27, 31, and 35 N-m. At a closing torque of 31 N-m, a leak rate of 0.028 scc/sec was achieved at 2 K, while at a torque of 18 N-m the leak rate at 300 K was less than 3 x 10 to the -9th scc/sec.

Salerno, L. J.↗

Monocrystals for the investigation of gravity phenomena

The usefulness for gravity experiments of monocrystals with very high mechanical quality factors is reviewed. Measurements carried on four point mechanical suspensions at liquid helium temperature are reported. Qs of 400 x 10 to the 6th have been measured for the longitudinal mode of sapphire and ruby crystals. A Q of 80 x 10 to the 6th was measured for the bending mode of a silicon crystal.

Richard, J.-P.↗

Fluid/Vapor Separator for Variable Flow Rates

Shutter varies gas throughput of porous plug. Variable area exposed on porous plug allows to pass varying rates of vapor flow while blocking flow of liquid helium II from cryogenic bath. Applications in refining operations, industrial chemistry, and steam-powered equipment.

Lee, J. M.↗