Search NASASearch

SEARCH · Search NASA

Results for “Measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

596 records · Page 25

Are Deep Energy Retrofits in Commercial Buildings Including Window Upgrades?

U.S. Commercial buildings account for about 20% of total U.S. energy consumption. Because the thermal performance of windows significantly affects building energy efficiency and HVAC system performance, best practice guidance often includes window and envelope improvements in conjunction with HVAC upgrades to optimize energy use and improve occupant comfort. It is an open question, however, regarding how often these best practices are implemented in the field. This paper aims to address that gap by conducting a literature review and a series of interviews with commercial building auditing and management professionals to explore the factors that drive window retrofits in commercial buildings. The paper explores a range of case studies from deep energy retrofits across the globe, comparing projects with and without window retrofits. The primary goals of this review are to: (1) provide data from real-world case studies illustrating the role of windows in deep energy renovations and HVAC upgrades, (2) conduct retrofit cost analyses for windows and high-performance HVAC systems and (3) offer insights into how window upgrade decisions are made and when they are implemented as part of deep energy retrofits. Most of the retrofit studies focused exclusively on high performance HVAC upgrades without considering how window upgrades might further enhance the overall energy efficiency of commercial buildings. Interviews with building industry experts shed light on the key factors influencing deep energy retrofit decisions and what factors tip the scales in favor of including window measures with more comprehensive retrofit projects.

Cort, Katherine

Fracture Analysis of Cohesive Zone Models for Modeling Residual Stress Induced Delamination in Composite Structures

A fracture study of coupon-scale composite cylinders with embedded defects was conducted with an objective to assess and validate a modeling approach using two available cohesive material models. The study included experimental and simulation evaluations of initiation of crack growth and progression. Interrupted thermal experiments used acoustic emissions monitoring to identify the onset of crack progression during each cooling interval and ultrasonic scanning provided images of defect growth. Verification, validation, and uncertainty quantification (VVUQ) processes were performed in the assessment of the simulation predicted temperature at which crack propagation begins (quantity of interest). The Sobol sensitivity analysis identified the hoop direction elastic modulus in the carbon fiber reinforced polymer (CFRP) plies as the most influential parameter for simulations using both cohesive models, accounting for at least 70% of the variation in the temperature at crack propagation. The UQ temperature range for the Tvergaard-Hutchinson model was higher (more conservative) than the experimental acoustic measurement indicators of crack progression, while the temperature range for the Thouless-Parmigiani model enveloped the experimental data points for the primary defect size of 0.75 x 1 in. The simulations could not capture the stable crack growth indicated in the experiments. This is likely due to the models’ inability to represent anisotropic fracture toughness attributed to the structure of the orthotropic fiber weave in a woven composite laminate.

42 ENGINEERING

Invisible water in subducted crust: Lawsonite velocity anomalies under mantle conditions

Subduction zones transport significant amounts of water into Earth’s mantle, primarily through hydrous minerals such as lawsonite. However, the seismic detectability of lawsonite-bearing oceanic crust at mantle depths remains uncertain. To address this issue, we measured sound velocities of lawsonite up to 7.4 GPa and 600 °C. Both P- and S-wave velocities exhibited unexpected increases with temperature under high-pressure conditions. Our result suggest that hydrous oceanic crust exhibits higher seismic velocities than the surrounding mantle at depths of 150 to 250 km, resulting in high-velocity anomalies rather than the previously assumed low-velocity anomalies. Furthermore, the seismic velocity difference between hydrous and dry oceanic crust is less than 2%, making it challenging to distinguish between them using seismic velocities. This limitation may hinder the detection of the hydration state in subducted crust. In addition, lawsonite remains stable in 90% of subduction zones, and thus, such “seismically invisible water” may exist in most subducted slabs around the world.

36 MATERIALS SCIENCE

Effect of Oxidizing Impurities on the Corrosion Behavior of Structural Alloys Exposed to MgCl 2 Molten Salt Vapor

The corrosion behavior of structural alloys SS304 and IN617 when exposed to vapors of MgCl 2 molten salt at 764 °C for 100 h in an argon atmosphere was investigated as a function of the level of oxidizing impurities (e.g., NaOH) present in the salt. Increasing the concentration of oxidizing impurities in the salt caused an increase in corrosion in both structural alloys, as measured by Cr depletion layers. A poorly adhered oxide scale layer containing Mg, Al, and Cr was observed on the surface of the metals, and local attack was observed as well. The Ni-based IN617 showed lower Cr depletion and less scale formation than the Fe-based SS304. These results demonstrate that oxidizing impurities in the molten salt will impact the vapor phase corrosion for structural members exposed to the molten salt headspace. This finding is highly relevant for understanding the effects of the vapor phase in molten salt applications, including molten salt thermal energy storage, molten salt nuclear reactors, and molten salt electrochemistry.

25 ENERGY STORAGE

Real-space visualization of a defect-mediated charge density wave transition

Here, we study the coupled charge density wave (CDW) and insulator-to-metal transitions in the 2D quantum material 1T-TaS 2 . By applying in situ cryogenic 4D scanning transmission electron microscopy with in situ electrical resistance measurements, we directly visualize the CDW transition and establish that the transition is mediated by basal dislocations (stacking solitons). We find that dislocations can both nucleate and pin the transition and locally alter the transition temperature T c by nearly ~75 K. This finding was enabled by the application of unsupervised machine learning to cluster five-dimensional, terabyte scale datasets, which demonstrate a one-to-one correlation between resistance—a global property—and local CDW domain-dislocation dynamics, thereby linking the material microstructure to device properties. This work represents a major step toward defect-engineering of quantum materials, which will become increasingly important as we aim to utilize such materials in real devices.

4D-STEM

Characterization of Flashback and Flame-Holding in a Jet-in-Crossflow Mixing Configuration With Methane–Hydrogen Fuel Blends

An approach that combines experimental and numerical analyses has been implemented to characterize the fundamentals of flashback events and flame-holding phenomena during high-hydrogen combustion in a jet-in-crossflow (JICF) configuration. Such flame dynamics are visualized experimentally using nanosecond (ns)-based hydroxyl planar laser-induced fluorescence (OH-PLIF) and chemiluminescence diagnostics techniques. The JICF burner has an optically accessible premixing tube allowing the optical diagnostics. The testing was conducted for varied premixer velocities (V) and equivalence ratio (ϕ) for 90–100% (H 2 , by mole) H 2 /CH 4 reactant mixtures at atmospheric temperature and pressure conditions. Two distinct flashback events were identified – conventional rich flashback and lean flashback, recorded while increasing ϕ and decreasing ϕ, respectively. The cause of lean flashback was attributed to lower momentum flux ratio which bends the jet sharply, closer toward the injection plane. The mean OH-PLIF images characterized the flame-holding behavior, where the flame was found to be stabilized on the leeward side only or on both windward and leeward sides as a lifted flame near the fuel port. A large eddy simulation (LES) with detailed chemistry combustion modeling approach was implemented along with an OH* submechanism, and it showed qualitative agreement with the integrated line-of-sight chemiluminescence results as well as the planar OH-PLIF measurements.

chemiluminescence diagnostic

Phase Stability and Electrochemical Performance of La-Site-Doped Li6La3Zr0.5Nb0.5Ta0.5Hf0.5O12 High-Entropy Garnets

We investigate La-site substitution in the high-entropy garnet Li6La3Zr0.5Nb0.5Ta0.5Hf0.5O12 (LLZNTH) using Ba2+, Sr2+, and Sm3+ to elucidate how dopant governs phase stability, Li-site distribution, and electrochemical behavior. X-ray diffraction shows that Sr2+ is incorporated homogeneously into the garnet lattice, whereas the larger Ba2+ and smaller Sm3+ ions partially exceed the structural tolerance, generating secondary phases. Nevertheless, the Sm-doped composition (x = 0.05) exhibits the highest room-temperature ionic conductivity (2.7 × 10–4 S cm–1). Neutron powder diffraction reveals that Sm substitution drives a redistribution of Li+ from the tetrahedral 24 d sites into the higher-mobility 96 h positions, enhancing the connectivity of the three-dimensional Li-ion migration network. A Sm-doping series (x = 0.01–0.05) further shows that only sufficiently high Sm levels induce this redistribution, whereas lower concentrations retain Li arrangements similar to the undoped garnet. Critical current density measurements demonstrate that La-site dopants also influence interfacial stability against Li metal, underscoring a trade-off between bulk transport enhancement and mechanical robustness. Collectively, these findings reveal that in high-entropy garnets improved ionic conductivity can originate not only from phase-pure structures but also from targeted modification of the Li sublattice, even when accompanied by secondary phases, offering a compositional design principle for garnet electrolytes.

Li, Chang [Mechanical Engineering, School of Scien

Osmotic and phoretic competition explains chemotaxic assembly and sorting

Microscale objects responding to chemical gradients by migrating toward or away from a preferred species is a simple yet constitutive mechanism by which transport occurs in biological organisms. Synthetic chemotaxis provides key physical descriptions of simplified systems that can be used in biological models, or in the creation of advanced responsive material systems. In this article, we provide a quantitative framework for understanding synthetic chemotaxis of microparticles which involves a competition between phoresis and osmosis. We present separate quantitative measurements of phoresis and osmosis acting on individual taxing particles, finding that phoresis follows the long-predicted v ∼ 1 / r 2 scaling while the osmotic contribution depends on the geometry and details of the system, and must be solved on a case-by-case basis. Through this, we are able to develop a more accurate picture of particle transport at the single particle level. Equipped with this approach, we go on to describe how high concentrations of particles in a symmetric chemical gradient grow close-packed hives that reach a steady-state size tunable through light intensity or particle size. Last, we demonstrate that mixed particles experiencing the same chemical gradient will selectively migrate toward or away depending on the nature of the particle surface, thereby locally sorting out a particular species. We anticipate these results will be important in describing both biological and synthetic chemotaxis in phoretic systems and should bring a wealth of studies that take advantage of competing osmotic flows to illicit unexpected dynamic active behavior.

Science & Technology - Other Topics

Multi-sensor Observations of a High-velocity Fireball over the South Atlantic on 2026 April 1

A high-velocity fireball was detected over the South Atlantic (41.9°S, 54.7°W) on 2026 April 1 at 02:13:14 UTC by U.S. Government (USG) sensors, with peak brightness at 90.5 km altitude. The event was well-observed from geostationary orbit by two civilian lightning imagers with near-orthogonal geometry, the Geostationary Operational Environmental Satellite-East Geostationary Lightning Mapper (GLM) and the Exploitation of Meteorological Satellites Meteosat Third Generation Imager 1 Lightning Imager, and it produced low-frequency acoustic signatures. The GLM measured a total radiated energy of 2.4 × 10 10 J, corresponding to a calculated impact energy of 0.086 kt TNT equivalent. Stereoscopic triangulation of the imager tracks yields an independent pre-atmospheric velocity of ~57 km s −1 , some 18% below the USG-reported value. Because orbital provenance is acutely sensitive to the entry velocity, whose reported uncertainty could be substantial, this discrepancy is notable. We document the multi-sensor record and identify the analysis required to assess provenance, which a subsequent study will present.

Silber, Elizabeth Allaryce [Sandia National Lab. (

Following the αCen Ab Candidate Using the Roman Coronagraph Instrument

The Roman Space Telescope Coronagraph offers a unique opportunity to observe our nearest solar twin, Alpha Centauri A, and characterize the habitable-zone gas giant candidate, Alpha Cen Ab. The candidate uniquely stands out among all imaged exoplanets to date as the one most similar in temperature, age and location to the planets in our own Solar System. Roman CGI offers the tantalizing opportunity to observe the candidate—determining its radius, temperature, and albedo—and to constrain its orbit. Observing Alpha Cen Ab with Roman would make it the first exoplanet to be imaged in both thermal emission and reflected light and would motivate an exciting search for habitable exomoons with the upcoming ELTs and HWO. In addition, this candidate will inform the planet formation history and current dynamics of the Alpha Centauri AB system, including potentially habitable planets around both stars. In this talk, we describe our plan to observe this target using the Roman CGI, including the timing strategy to minimize contrast and avoid background objects. We also describe the key technical insights about coronagraph performance that we aim to gain, such as measuring companion leakage intensity, evaluating the impact of the large stellar diameter, and assessing CGI performance on very bright targets. In subsequent observations, we aim to demonstrate Multi-Star Wavefront Control (MSWC) on-sky, observing Alpha Cen A using the Wide FoV Shaped Pupil MSWC contributed mode in the Roman CGI. The insights from these technology demonstrations are crucial preparation for the planned HWO mission.

Coronagraph

Trust-Based Detection and Mitigation of Cyber Attacks in Distributed Cooperative Control of Islanded AC Microgrids

In this study, we address the challenge of detecting and mitigating cyber attacks in the distributed cooperative control of islanded AC microgrids, with a particular focus on detecting False Data Injection Attacks (FDIAs), a significant threat to the Smart Grid (SG). The SG integrates traditional power systems with communication networks, creating a complex system with numerous vulnerable links, making it a prime target for cyber attacks. These attacks can lead to the disclosure of private data, control network failures, and even blackouts. Unlike machine learning-based approaches that require extensive datasets and mathematical models dependent on accurate system modeling, our method is free from such dependencies. To enhance the microgrid’s resilience against these threats, we propose a resilient control algorithm by introducing a novel trustworthiness parameter into the traditional cooperative control algorithm. Our method evaluates the trustworthiness of distributed energy resources (DERs) based on their voltage measurements and exchanged information, using Kullback-Leibler (KL) divergence to dynamically adjust control actions. We validated our approach through simulations on both the IEEE-34 bus feeder system with eight DERs and a larger microgrid with twenty-two DERs. The results demonstrated a detection accuracy of around 100%, with millisecond range mitigation time, ensuring rapid system recovery. Additionally, our method improved system stability by up to almost 100% under attack scenarios, showcasing its effectiveness in promptly detecting attacks and maintaining system resilience. These findings highlight the potential of our approach to enhance the security and stability of microgrid systems in the face of cyber threats.

Computer Science

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Incremental Learning for Passive Microwave Precipitation Retrievals using Advanced Technology Microwave Sounder

Spaceborne passive microwave (PMW) radiometry is central to global precipitation monitoring, yet retrieval uncertainties remain substantial, particularly for cross-track sounders whose variable footprints and channel configurations are optimized for atmospheric temperature and moisture profiling rather than precipitation. Consequently, existing operational products often exhibit angular-dependent biases, limited effective swath utilization, unrealistic rainfall probability distributions, and systematic misclassification of precipitation phase. These limitations are further compounded by the scarcity of globally accurate and representative precipitation observations, as training data from the Dual-frequency Precipitation Radar (DPR) and the Cloud Profiling Radar (CPR) are spatially sparse, lack uniform global coverage, and exhibit heterogeneous error characteristics across precipitation regimes. To address these challenges, this study presents a supervised retrieval algorithm that incrementally trains an ensemble of extreme gradient-boosted decision trees by augmenting base learners with pre-training on reanalysis data and post-training on coincident DPR and CPR observations matched with the Advanced Technology Microwave Sounder (ATMS). By transferring prior information from reanalysis to posterior constraints from radar observations and adopting a sequential detection–estimation strategy for precipitation phase and rate retrieval, the proposed approach yields retrievals across the full ATMS swath that are largely free from persistent deficiencies in current Global Precipitation Measurement (GPM) passive microwave operational products. In particular, the method resolves bimodal artifacts in rainfall retrievals and mitigates systematic high-latitude snowfall biases, including overestimation across the Arctic and underestimation across the Antarctic. Validation against independent Multi-Radar Multi-Sensor (MRMS) data over the Contiguous United States (CONUS) further demonstrates improved performance in precipitation phase detection and rate estimation relative to both reanalysis and current GPM PMW products.

Mahyar Garshasbi

X-ray linear dichroic tomography of crystallographic and topological defects

Abstract The functionality of materials is determined by their composition 1–4 and microstructure, that is, the distribution and orientation of crystalline grains, grain boundaries and the defects within them 5,6 . Until now, characterization techniques that map the distribution of grains, their orientation and the presence of defects have been limited to surface investigations, to spatial resolutions of a few hundred nanometres or to systems of thickness around 100 nm, thus requiring destructive sample preparation for measurements and preventing the study of system-representative volumes or the investigation of materials under operational conditions 7–15 . Here we present X-ray linear dichroic orientation tomography (XL-DOT), a quantitative, non-invasive technique that allows for an intragranular and intergranular characterization of extended polycrystalline and non-crystalline 16 materials in three dimensions. We present the detailed characterization of a polycrystalline sample of vanadium pentoxide (V 2 O 5 ), a key catalyst in the production of sulfuric acid 17 . We determine the nanoscale composition, microstructure and crystal orientation throughout the polycrystalline sample with 73 nm spatial resolution. We identify and characterize grains, as well as twist, tilt and twin grain boundaries. We further observe the creation and annihilation of topological defects promoted by the presence of volume crystallographic defects. The non-destructive and spectroscopic nature of our method opens the door to operando combined chemical and microstructural investigations 11,18 of functional materials, including energy, mechanical and quantum materials.

Science & Technology - Other Topics

Towards an Improved Understanding of the Antarctic Coastal Zone and Its Contribution to Future Global Sea Level

Understanding the coastal zone of the Antarctic Ice Sheet (AIS), where it interacts with the Southern Ocean and warmer air masses, is crucial for predicting Antarctica's influence on the global climate and sea level. This region has multiple tipping mechanisms that could trigger large, rapid, and potentially irreversible changes in the AIS, the Southern Ocean and their global connections in the coming centuries. The AIS remains the largest source of uncertainty in future sea-level projections. Bed topography beneath the ice shelves and the coastal ice sheet is not yet well documented, and is a major source of this uncertainty. This review assesses current knowledge of the coastal zone and highlights methods to investigate it, including aerogeophysical surveys, ground- and ship-based measurements, satellite observations, and computer modeling. An ensemble analysis of published bed topography data sets identifies significant data gaps and their regional distribution, framed in the context of current ice-sheet behavior and potential instability. We propose scientific priorities and guidelines for future aerogeophysical surveys, advocating for a comprehensive, coordinated international effort to build a next-generation data set of Antarctic bed properties. Such an initiative would significantly advance understanding of the role of coastal processes in ice-sheet dynamics, reducing uncertainties in sea-level rise projections and improving predictions of future ocean and climate changes.

Kenichi Matsuoka

On-Chip Tuning of Superconductivity in Fullerides via Current-Driven Rb + Intercalation

An in-operando electro-intercalation method for the on-chip synthesis of alkali-metal-intercalated materials and their Raman spectroscopic and transport characterization in ultrahigh vacuum (UHV) is developed. We apply this method to synthesize fulleride superconductors via Rb + intercalation into a C 60 film. During the intercalation, we monitor the stoichiometry via UHV-Raman spectroscopy and probe superconductivity via transport measurements. An increase of the superconducting transition temperature from 7.0 K to 14.5 K is observed when the stoichiometry is tuned from Rb 2.7 C 60 to Rb 3 C 60 . In our experiment, an ionic Rb+ flux into the host material is induced by an applied electronic current via a Butler–Volmer-type mechanism. Electro-intercalation captivates through improved stoichiometric precision, the ability to smoothly vary stoichiometry via duration of current application, and the absence of a lower limit of the volume of the host material. It represents a powerful concept for the on-chip synthesis of intercalated materials, battery research, and beyond.

Raman

Scaling Demand Flexibility: Building on 30 Years of Energy Efficiency Success

With electricity consumption across the United States (US) and Canada anticipated to grow, energy efficiency program administrators have a key role to play in helping to ensure energy affordability and reliability in support of the broader economic systems utilities and grid support. Connected, demand side load balancing solutions, such as load shifting heating, ventilation and air conditioning (HVAC) systems and managed charging for electric vehicles (EVs), can dynamically manage energy, allowing for more volumetric electricity consumption without incurring the expense of upgraded transmission and distribution capabilities. When combined, or aggregated, many small loads can be managed to have meaningful impact on energy demand on the grid. Utilities and their partners have an opportunity to leverage decades of experience and the infrastructure needed to assess, design, implement, and measure programs to scale up the adoption of equipment with built-in load flexibility capabilities. Current efforts among a wide variety of electricity system service providers, utilities, standards agencies, regulators, national labs and private industry stakeholders aim to identify common standards, metrics, and methodologies for valuing grid services offered by demand side equipment. By combining those efforts with decades of proven energy efficiency resources, utilities are poised to effectuate a scaling up of equipment with energy management capabilities installed in homes and businesses across the US and Canada. This paper will provide an overview of how utilities are approaching this era of load growth and new peak demands across the United States and Canada. It will highlight the specific strategies that program administrators are employing to advance market transformation for grid-enabled products and devices that have the greatest potential to reduce energy use and increase load flexibility.

Grant, Peter

Manipulation of Localized Excitons in CrPS4 by Temperature and Magnetic Field

Layered van der Waals magnetic semiconductors provide a versatile platform for exploring excitonic phenomena intertwined with spin and lattice degrees of freedom, enabling excitons to act as sensitive probes of magnetic order. CrPS4 is a layered antiferromagnetic semiconductor that hosts rich excitonic features whose microscopic origin and connection to magnetic ordering remain incompletely understood. Here, we investigate the electronic and excitonic properties of bulk CrPS4 using a combination of many-body perturbation theory, dynamical mean-field theory, and photoluminescence-based experiments. Our calculations establish CrPS4 as a direct-gap semiconductor with a bandgap of 2.48 eV in the antiferromagnetic phase. Several subbandgap excitonic transitions are predicted by theory, comprising multiple spin-allowed excitons and an additional spin-flip excitation, predominantly localized on the Cr3+ ions. Temperature- and magnetic-field-dependent optical measurements reveal thermally driven exciton redistribution among localized states and identify characteristic energy shifts that provide clear optical signatures of magnetic phase transitions in CrPS4. These results provide insights into the excitonic transitions of antiferromagnets and suggest potential routes for all-optical sensing and light-driven control of their magnetic order.

2D materials