Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Stripline Block Sensor System

he Long Baseline Neutrino Facility requires remote handling of the stripline block, the component responsible for providing current to the focusing horns. There are many constraints due to the surroundings the modules reside in such as small clearances as well as a highly radioactive environment. Existing systems have already been implemented within the process; however, these systems offer limited information leaving much risk during operations. This calls for a sensor system that is sufficiently accurate, complies with project constraints, and provides valuable information throughout the replacement period. A proposed solution utilizes a three dimensional indoor positioning system to provide the operator with real-time positioning and rotational information. Future work would consist of finding vendors capable of providing technology that fits our constraints, proof of concept tests, implementation planning, as well as trails within the target hall itself. A three dimensional indoor positioning system would provide an incredibly diverse tool capable of being utilized in a variety of situations.

Espinoza, David↗

A 12.5 GHz-spaced optical frequency comb spanning >400 nm for near-infrared astronomical spectrograph calibration

A 12.5 GHz-spaced optical frequency comb locked to a global positioning system disciplined oscillator for near-infrared (IR) spectrograph calibration is presented. The comb is generated via filtering a 250 MHz-spaced comb. Subsequent nonlinear broadening of the 12.5 GHz comb extends the wavelength range to cover 1380-1820 nm, providing complete coverage over the H-band transmission window of earth's atmosphere. Finite suppression of spurious sidemodes, optical linewidth, and instability of the comb has been examined to estimate potential wavelength biases in spectrograph calibration. Sidemode suppression varies between 20 and 45 dB, and the optical linewidth is {approx}350 kHz at 1550 nm. The comb frequency uncertainty is bounded by {+-}30 kHz (corresponding to a radial velocity of {+-}5 cm/s), limited by the global positioning system disciplined oscillator reference. These results indicate that this comb can readily support radial velocity measurements below 1 m/s in the near IR.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Uranium Attenuated by a Wetland 50 Years after Release into a Stream

: Wetlands have several important roles in the hydrological cycle, including maintaining water quality by removing surface and groundwater contaminants. Over time, the wetlands themselves can become contaminated, posing a secondary environmental threat. The objective of this study was to calculate the inventory of uranium (U) remaining in a wetland 50 years after the Fuel Fabrication Facility on the Savannah River Site located in South Carolina released 43.5 Mg of U into the nearby environment. Over 232 700 gamma spectra and their associated global positioning system (GPS) coordinates were collected and collated into a map of the contaminated land area. Five core samples were also collected that contained U concentrations as high as 14 099 mg/kg (background levels are about 2.7 mg/kg U). The contaminated area was 278 000 m2 , and it contained 36.2 Mg U, about 83% of the U released. About 80% of the U in the wetland was concentrated in a former beaver pond, a 73 000 m2 area (26% of the contaminated area). This contaminated wetland area was almost 2 km from the source, indicating that it comprised unique hydro-biogeochemical properties for immobilizing the released U. To the best of our knowledge, this is the first data-rich study to quantify the long-term effectiveness of a wetland to immobilize inorganic contaminants. Significant environmental changes to the system, such as those associated with hydrology, forest fires, or anthropogenic land use, may alter the complex hydro-biogeochemical interactions necessary for the long-term immobilization of the U.

Contaminant inventory↗

Containerless processing technology

A brief review of containerless processing activities sponsored by NASA's Microgravity Science Division is presented. Attention is given to ground based systems such as shot tower processing of molten materials, single axis levitation and flight processing concepts including BeO processing aboard the Space Shuttle, a medium temperature three-axis acoustic positioning system and a high temperature single axis acoustic positioning system. In the future, more sophisticated experiments will be conducted using improved measurement techniques which will quantitatively define the advantages of containerless processing, as well as improve the understanding of nuclear kinetics and of the thermophysical properties of materials at high temperatures.

Oran, W. A.↗

NASA program

Areas of the NASA global positioning system (GPS) related programs including satellite/navigation tracking, shuttle applications, land/sea applications, and civil aviation applications are described. The development of technologies for the GPS such as high precision RNAV, a collision warning/avoidance system, and an automated position, velocity, identification reporting system is discussed.

Reid, H. J., Jr.↗

Lithospheric dynamics near plate boundaries

The progress report on research conducted between 15 Mar. - 14 Sep. 1992 is presented. The focus of the research during the first grant year has been on several problems broadly related to the nature and dynamics of time-dependent deformation and stress along major seismic zones, with an emphasis on western North America but with additional work on seismic zones in oceanic lithosphere as well. The principal findings of our research to date are described in the accompanying papers and abstract. Topics covered include: (1) Global Positioning System measurements of deformations associated with the 1987 Superstition Hills earthquake: evidence for conjugate faulting; (2) Global Positioning System measurements of strain accumulation across the Imperial Valley, California: 1986-1989; (3) present-day crustal deformation in the Salton Trough, southern California; (4) oceanic transform earthquakes with unusual mechanisms or locations: relation to fault geometry and state of stress in the lithosphere; and (5) crustal strain and the 1992 Mojave Desert earthquakes.

Solomon, Sean C.↗

Propagation effects on satellite systems at frequencies below 10 GHz: A handbook for satellite systems design

Frequencies below 10 GHz continue to be used for a large portion of satellite service, and new applications, including mobile satellite service and the global positioning system, use frequencies below 10 GHz. As frequency decreases below 10 GHz, attenuation due to precipitation and gases decreases and ionospheric effects increase. Thus the ionosphere, which can be largely neglected above 10 GHz, receives major attention. Although attenuation and depolarization due to rain are less severe below 10 GHz than above, they are nevertheless still important and constitute another major topic. The handbook emphasizes the propagation effects on satellite communications but material that is pertinent to radio navigation and positioning systems and deep-space telecommunications is included as well. Chapter 1 through 7 describe the various propagation impairments, and Chapter 9 is devoted to the estimation or calculation of the magnitudes of these effects for use in system design. Chapter 10 covers link power budget equations and the role of propagation effects in these equations. Chapter 8 deals with the complex subject of interference between space and terrestrial systems.

Flock, Warren L.↗

Spaceborne GPS Current Status and Future Visions

The Global Positioning System (GPS), developed by the Department of Defense, is quickly revolutionizing the architecture of future spacecraft and spacecraft systems. Significant savings in spacecraft life cycle cost, in power, and in mass can be realized by exploiting Global Positioning System (GPS) technology in spaceborne vehicles. These savings are realized because GPS is a systems sensor-it combines the ability to sense space vehicle trajectory, attitude, time, and relative ranging between vehicles into one package. As a result, a reduced spacecraft sensor complement can be employed on spacecraft and significant reductions in space vehicle operations cost can be realized through enhanced on- board autonomy. This paper provides an overview of the current status of spaceborne GPS, a description of spaceborne GPS receivers available now and in the near future, a description of the 1997-1999 GPS flight experiments and the spaceborne GPS team's vision for the future.

Bauer, Frank H.↗

Ionosphere Delay Calibration and Calibration Errors for Satellite Navigation of Aircraft

The Federal Aviation Administration (FAA) is implementing a satellite-based navigation system for aircraft using the Global Positioning System (GPS). Positioning accuracy of a few meters will be achieved by broadcasting corrections to the direct GPS signal. These corrections are derived using the wide-area augmentation system (WAAS), which includes a ground network of at least 24 GPS receivers across the Continental US (CONUS). WAAS will provide real-time total electron content (TEC) measurements that can be mapped to fixed grid points using a real-time mapping algorithm. These TECs will be converted into vertical delay corrections for the GPS L1 frequency and broadcast to users every five minutes via geosynchronous satellite. Users will convert these delays to slant calibrations along their own lines-of-sight (LOS) to GPS satellites. Uncertainties in the delay calibrations will also be broadcast, allowing users to estimate the uncertainty of their position. To maintain user safety without reverting to excessive safety margins an empirical model of user calibration errors has been developed. WAAS performance depends on factors that include geographic location (errors increase near WAAS borders), and ionospheric conditions, such as the enhanced spatial electron density gradients found during ionospheric storms.

Harris, Ian↗

Validation of ADAR System 5500 Digital Imagery: Delivery Task Order #1, Task Request #857 - Brookings, SD

This work was performed under NASA's Verification and Validation Program as an independent check of data supplied by Positive Systems, Inc. through the Earth Science Enterprise's Scientific Data Purchase (SDP) Program. This document serves as the basis for reporting results associated with validation of multispectral imagery according to the specifications of contract NAS 13-98049. The validation was performed under the Positive Systems Imaging System Validation Work Instruction CRSP-WI-28: Spectral registration, spatial resolution, endlaps, sidelaps, and image quality were evaluated. The validation was proceded by Shipment Verification, as described in the Work Instruction CRSP-WI-22: Every image was passed through an automatic ingest verification and thumbnail review process to identify omissions, problems with media integrity, and gross errors in data quality. Validation of metadata files is not within the scope of this report, but it was performed separately.

Blonski, Slawomir↗

Using GPS Receiver 1PPS Output to Verify Time Stamp Accuracy and Measure Propagation Delay

A simple pulse overlay circuit using a logic OR gate was developed to overlay a precise leading edge 1 pulse per second time reference marker from a global positioning system receiver onto a non-return -to- zero-level pulse code modulation telemetry data stream to validate time stamp accuracy and measure propagation delay in telemetry equipment. A pulse overlay (PO) circuit was designed to produce a time reference marker within a pulse code modulation (PCM) telemetry data stream that was recorded and analyzed to validate an IRIG Standard 106-17 Chapter 10 recorder’s time stamp accuracy [1]. A manufacturer of a newly purchased Chapter 10 recorder claimed the time stamp accuracy to be better than 10 microseconds (μs) with only IRIG-B120 (IRIG-B) input and better than 1 μs with IRIG-B and one pulse per second (1PPS) inputs. The PO circuit and a Chapter 10 recorder test setup were used to verify the vendor’s data-time synchronization claims and to justify infrastructure upgrade costs to connect additional cables to each purchased recorder. The circuit was also used to measure the propagation delay (PD) of a long distance Telemetry multiplexer/demultiplexer telecommunication system which the manufacturer did not provide a PD specification. Using the one pulse per second time reference marker of the global positioning system receiver and the pulse overlay circuit to overlay the one pulse per second variable pulse width signal into a pulse code modulation telemetry stream provided an excellent means to validate time stamp accuracy within a Chapter 10 recorder and to measure propagation delays within a normal telemetry operating environment. The positive results from the Chapter 10 recorder tests validated the vendor’s claims and justified the implementation to add the one pulse per second signal to the range Chapter 10 recorders. The pulse overlay circuit and test setups defined in this paper can easily be used to measure other telemetry equipment.

Knudtson, Kevin↗

Cavity Beam Position Monitor System for ATF2

The Accelerator Test Facility 2 (ATF2) in KEK, Japan, is a prototype scaled demonstrator system for the final focus required for a future high energy lepton linear collider. The ATF2 beam-line is instrumented with a total of 38 C and S band resonant cavity beam position monitors (CBPM) with associated mixer electronics and digitizers. The current status of the BPM system is described, with a focus on operational techniques and performance. The ATF2 C-band system is performing well, with individual CBPM resolution approaching or at the design resolution of 50 nm. The changes in the CBPM calibration observed over three weeks can probably be attributed to thermal effects on the mixer electronics systems. The CW calibration tone power will be upgraded to monitor changes in the electronics gain and phase. The four S-band CBPMs are still to be investigated, the main problem associated with these cavities is a large cross coupling between the x and y ports. This combined with the large design dispersion in that degion makes the digital signal processing difficult, although various techniques exist to determine the cavity parameters and use these coupled signals for beam position determination.

43 PARTICLE ACCELERATORS↗

Multipath effects in a Global Positioning Satellite system receiver

This study, as a part of a large continuing investigation being conducted by the Communications Systems Branch of the Information and Electronic Systems Laboratory at the Marshall Space Flight Center, was undertaken to explore the multipath response characteristics of a particular Global Positioning Satellite (GPS) receiver which was available in the laboratory at the beginning and throughout the entirety of the study, and to develop a suitable regime of experimental procedure which can be applied to other state-of-the-art GPS receivers in the larger investigation.

Mcdonald, Malcolm W.↗

Stripline Block Sensor System

The Long Baseline Neutrino Facility requires a secondary sensor system to aid in the installation and replacement of the stripline blocks. These blocks are responsible for delivering large amounts of current to the horn and must be installed with high precision to avoid possible physical damage. There are many constraints due to the modules' surroundings, such as small clearances and a highly radioactive environment. Existing systems have already been implemented within the process; however, these systems offer limited information, leaving much risk during operations. This calls for a sufficiently accurate sensor system, which has a small space requirement and provides valuable information throughout the replacement period. A variety of methods and technologies were explored to provide an applicable approach to the issue. The proposed solution consisted of the use of retroreflective and target, however, it cannot provide positional feedback throughout the entire process. A proposed alternative utilizes a three-dimensional indoor positioning system to provide the operator with real-time positioning and rotational information. Sensors placed on the module and stripline would communicate with fixed receivers surrounding the target hall to provide precise positional feedback. However, this solution may still contain line-of-sight issues as well as installation complications due to the radioactive environment. Future work would consist of finding vendors capable of providing technology that fits our constraints, proof of concept tests for both solutions, implementation planning, and trials within the target hall itself. Due to its ability to provide continuous positional and rotational feedback, the indoor positioning system is the most suitable solution for accurately installing the stripline block.

Espinoza, David [Unlisted, US]↗

Cavity Beam Position Monitor System for ATF2

The Accelerator Test Facility 2 (ATF2) in KEK, Japan, is a prototype scaled demonstrator system for the final focus required for a future high energy lepton linear collider. The ATF2 beam-line is instrumented with a total of 38 C and S band resonant cavity beam position monitors (CBPM) with associated mixer electronics and digitizers. The current status of the BPM system is described, with a focus on operational techniques and performance.

43 PARTICLE ACCELERATORS↗

TOPOS: A new topometric patient positioning and tracking system for radiation therapy based on structured white light

Purpose: A patient positioning system for radiation therapy based on structured white light and using off-the-shelf hardware components for flexibility and cost-effectiveness has been developed in house. Increased accuracy, patient comfort, abandonment of any skin marks, accelerated workflow, objective reading/recording, better usability and robust sensor design, compared to other positioning approaches, were the main goals of this work. Another aim was the application of a 6 degrees of freedom tracking system working without dose deposition. Methods: Two optical sensors are the main parts of the TOPOS Registered-Sign system (Topometrical Positioning, cyberTECHNOLOGIES, Germany). The components: cameras, projectors, and computers are commercial off-the-shelf products, allowing for low production costs. The black/white cameras of the prototype are capable of taking up to 240 frames per second (resolution: 640 Multiplication-Sign 488 pixels). The projector has a resolution of 1024 Multiplication-Sign 768 and a refresh rate of 120 Hz. The patient's body surface is measured continuously and registered to a reference surface, providing a transformation to superimpose the patient's surface to the reference (planning CT) surface as best as possible. The execution of the calculated transformation provides the correct patient position before the treatment starts. Due to the high-speed acquisition of the surfaces, a surveillance of the patient's (respiration) motion during treatment is also accomplished. The accuracy of the system was determined using a male mannequin. Two treatment sites were evaluated: one simulating a head and neck treatment and the other simulating a thoracic wall treatment. The mannequin was moved to predefined positions, and shift vectors given by the surface registration were evaluated. Additionally manual positioning using a color-coding system was evaluated. Results: Two prototypes have been developed, each allowing a continuous high density scan of a 500 Multiplication-Sign 500 Multiplication-Sign 400 mm{sup 3} (L Multiplication-Sign W Multiplication-Sign D) large volume with a refresh rate of 10 Hz (extendible to 20 Hz for a single sensor system). Surface and position correction display, as well as respiratory motion, is shown in real-time (delay < 200 ms) using present graphical hardware acceleration. For an intuitive view of the patient's misalignment, a fast surface registration algorithm has been developed and tested and a real-time color-coding technique is proposed and verified that allows the user to easily verify the position of the patient. Using first the surface registration and then the color coding the best results were obtained: for the head and neck case, the mean difference between the actual zero position and the final match was 0.1 {+-} 0.4, -0.2 {+-} 0.7, and -0.1 {+-} 0.3 mm in vertical, longitudinal, and lateral direction. For the thoracic case, the mean differences were 0.3 {+-} 0.5, -0.6 {+-} 1.9, 0.0 {+-} 0.4 mm. Conclusions: The presented system copes with the increasing demand for more accurate patient positioning due to more precise irradiation technologies and minimizes the preparation times for correct patient alignment, therefore optimizing the treatment workflow. Moreover, TOPOS is a versatile and cost effective image guided radiation therapy device. It allows an objective rating of the patient's position before and during the irradiation and could also be used for respiratory gating or tracking.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Codeless GPS Applications to Multi-Path: CGAMP

Cordless Global Positioning System (GPS) Applications to Multi-Path (CGAMP) is meeting the challenge of exploiting the L-band signals from the Global Positioning System (GPS) satellites for the measurement of the impulse response of radio transmission channels over space-Earth paths. This approach was originally suggested by E. K. Smith and has been pursued by J. Lemmon, without an affordable implementation being identifiable. In addition to the high cost of a suitable P code correlating GPS receiver, there is also the major impediment of the often announced Department of Defense policy of selective availability/anti-spoof (SA/AS) that clouds reliable access to the wideband (20 MHz) P channel of the GPS signals without cryptographic access. A technique proposed by MacDoran utilizes codeless methods for exploiting the P channel signals implemented by the use of a pair of antennas and cross correlation signal detection.

Macdoran, P. F.↗

High precision GPS orbit determination using March 1985 demonstration data

Preliminary orbit determination for satellites in the U.S. Department of Defense's Global Positioning System has been performed using GPS carrier phase data collected in March-April 1985 at 10 sites in the continental United States. The data were analyzed using a new data processing software package called GIPSY (GPS Inferred Positioning SYstem) and with existing covariance analysis software. Data from one day have been processed with average formal position errors of 1.4 to 3.6 meters. The true errors are probably somewhat larger. Covariance results are presented which suggest that the orbits can be obtained with formal errors under 2 meters after certain software issues are resolved.

Bertiger, W.↗