Search NASA⌕ Search

SEARCH · Search NASA

Results for “Worker”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Guidelines for Posting Soil Contamination Areas

All soil guidelines were determined using RESRAD, version 6.1. All offsite guidelines are based on 15 mrem/year. This dose rate is sufficiently low to protect human health and is in accordance with DOE guidance and the proposed EPA 40-CFR-196 regulations for members of the public (never promulgated). For those onsite areas where general employees (non-radiological workers) could have routine access, soil concentrations should be based on a dose rate of 30 mrem/year (approximately one-third of the onsite LANL non-radiological worker dose of 100 mrem/year). In this case, soil concentration guidelines may be obtained by doubling the 15 mrem/year guidelines. Several scenarios were developed to provide maximum flexibility for application of the guidelines. The offsite guidelines were developed using: residential scenarios for both adults and children; a construction worker scenario; a resource user (e.g., a hunter) scenario; a child playing within canyon reaches scenario, a trail using jogger within canyon reaches scenario, and a trail using hiker within canyon reaches scenario. The residential guidelines represent the lowest values from both the adult residential scenario and the child residential scenario.

58 GEOSCIENCES↗

Sampling for Air Chemical Emissions from the Life Sciences Laboratory II

Sampling for air chemical emissions from the Life Science Laboratory II (LSL-II) ventilation stack was performed in an effort to determine potential exposure of maintenance staff to laboratory exhaust on the building roof. The concern about worker exposure was raised in December 2015 and several activities were performed to assist in estimating exposure concentrations. Data quality objectives were developed to determine the need for and scope and parameters of a sampling campaign to measure chemical emissions from research and development activities to the outside air. The activities provided data on temporal variation of air chemical concentrations and a basis for evaluating calculated emissions. Sampling for air chemical emissions was performed in the LSL-II ventilation stack over the 6-week period from July 26 to September 1, 2016. A total of 12 sampling events were carried out using 16 sample media. Resulting analysis provided concentration data on 49 analytes. All results were below occupational exposure limits and most results were below detection limits. When compared to calculated emissions, only 5 of the 49 chemicals had measured concentrations greater than predicted. This sampling effort will inform other study components to develop a more complete picture of a worker’s potential exposure from LSL-II rooftop activities. Mixing studies were conducted to inform spatial variation in concentrations at other rooftop locations and can be used in conjunction with these results to provide temporal variations in concentrations for estimating the potential exposure to workers working in and around the LSL-II stack.

54 ENVIRONMENTAL SCIENCES↗

Long-Term Instrumentation, Information, and Control Systems (II&C) Modernization Future Vision and Strategy

Life extension beyond 60 years for the U.S operating nuclear fleet requires that instrumentation and control (I&C) systems be upgraded to address aging and reliability concerns. It is impractical for the legacy systems based on 1970’s vintage technology operate over this extended time period. Indeed, utilities have successfully engaged in such replacements when dictated by these operational concerns. However, the replacements have been approached in a like-for-like manner, meaning that they do not take advantage of the inherent capabilities of digital technology to improve business functions. And so, the improvement in I&C system performance has not translated to bottom-line performance improvement for the fleet. Therefore, wide-scale modernization of the legacy I&C systems could prove to be cost-prohibitive unless the technology is implemented in a manner to enable significant business innovation as a means of off-setting the cost of upgrades. A Future Vision of a transformed nuclear plant operating model based on an integrated digital environment has been developed as part of the Advanced Instrumentation, Information, and Control (II&C) research pathway, under the Light Water Reactor (LWR) Sustainability Program. This is a research and development program sponsored by the U.S. Department of Energy (DOE), performed in close collaboration with the nuclear utility industry, to provide the technical foundations for licensing and managing the long-term, safe and economical operation of current nuclear power plants. DOE’s program focus is on longer-term and higher-risk/reward research that contributes to the national policy objectives of energy security and environmental security . The Advanced II&C research pathway is being conducted by the Idaho National Laboratory (INL). The Future Vision is based on a digital architecture that encompasses all aspects of plant operations and support, integrating plant systems, plant work processes, and plant workers in a seamless digital environment to enhance nuclear safety, increase productivity, and improve overall plant performance. The long-term goal is to transform the operating model of the nuclear power plants (NPP)s from one that is highly reliant on a large staff performing mostly manual activities to an operating model based on highly integrated technology with a smaller staff. This digital transformation is critical to addressing an array of issues facing the plants, including aging of legacy analog systems, potential shortage of technical workers, ever-increasing expectations for nuclear safety improvement, and relentless pressure to reduce cost. The Future Vision is based on research is being conducted in the following major areas of plant function: 1. Highly integrated control rooms 2. Highly automated plant 3. Integrated operations 4. Human performance improvement for field workers 5. Outage safety and efficiency. Pilot projects will be conducted in each of these areas as the means for industry to collectively integrate these new technologies into nuclear plant work activities. The pilot projects introduce new digital technologies into the nuclear plant operating environment at host operating plants to demonstrate and validate them for production usage. In turn, the pilot project technologies serve as the stepping stones to the eventual seamless digital environment as described in the Future Vision.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of an Active, Man-Portable, Cooling System with Dehumidification Capabilities for Personal Protective Clothing/Equipment

Mainstream Engineering Corporation completed a highly successful SBIR program, during which we developed and commercialized products for microclimate cooling systems (MCS) and the heating, ventilation, air-conditioning, and refrigeration (HVAC/R) industry. We are marketing the MCS family of products for use with personal protective clothing/equipment (PPC/PPE) for firefighters, workers in clean rooms, HAZMAT response and other contamination/remediation teams, and military personnel that are required to wear Mission-Oriented Protective Posture (MOPP) suits and bomb disposal suits. Workers in these industries risk heat stress when confined within protective garments while in hot and humid environments. Our family of MCS and HVAC/R products that resulted from this SBIR program includes: 1. Active, Man-Portable, MCS for PPC/E—Our active system provides 350 W cooling of personal cooling for workers in thermally stressed environments. Although industrially hardened, this system is compact (0.69 ft 3 ) and lightweight (22.9 lbs). The MSC is easily decontaminated or disposed of between uses. 2. Miniature Screw Compressor for MCS—Our 350 Wcooling miniature screw compressor was originally designed for MCS and personal cooling systems. Occupying only 11 in 3 and weighing 1.4 lbs, the size and weight are less than any commercially available compressor with a similar cooling capacity. This miniature screw compressor is marketable as a low-pressure compressor or refrigerant pump. 3. Miniature Sliding Vane Compressor and Drive for MCS—Our 350 Wcooling compressor subassembly consists of a commercial miniature sliding vane compressor packaged with our motor controller. At 29.4 in3 and 1.5 lbs, this compressor is larger and heavier than the miniature screw but is lower cost and capable of producing higher head pressure. 4. Small Screw Compressor for HVAC/R—Our 50 kW cooling small screw compressor is for commercial HVAC/R applications. This compressor is extremely power dense at 0.34 ft 3 and 43 lbs and has a specific cooling capacity (kW/lb) five times greater than existing commercial compressors. We demonstrated high reliability (>5,100 hrs of operation and >3,400 on/off cycles), and we are currently discussing commercialization opportunities with laser manufacturers for cooling of their high-power devices. This final report summarizes the design, fabrication, testing, features, and benefits of each product. The commercialization potential and recommendations for the future are included.

42 ENGINEERING↗

The Challenge and Promise of Remote Work: A Brief Study of Remote Work and Best Practices

Due to the shift in labor market from manufacturing and construction to service-based (Statistics 2016); the commoditization of high-bandwidth communication tools; advancements in management techniques; a dearth of trained knowledge workers within a geographic region; and a growing demand for flexible scheduling options, organizations are embracing and encouraging the growing distributed workforce. These workers are actual employees, not contractors; they may work independently or as part of a team; they have direct organizational supervision; and they work in a variety of virtual arrangements. This informal field study looks at several organizations that support the remote work model from the perspective of individual employees and presents several technologies, tools, and policies that can serve to maintain company culture and otherwise close the gap between onsite and remote workers.

99 GENERAL AND MISCELLANEOUS↗

User Requirements Specification for the Universal Real Time Controller: Ergonomic Design for Placement of Three NI 9157/9159 Chassis

The Air Delivered Weapons Tester Development Group (2256) is currently designing a new type of test system, the Universal Real Time Controller (URTCON). The URTCON will provide the surveillance community with technologies that advance the state of knowledge in stockpile stewardship. Success for its implementation depends on whether the components comprising the URTCON can be reliably and accurately maintained in the field. A system is maintainable when the worker has visual and physical access to the components that need to be serviced. To address this need, a layout was determined that best facilitates the worker's ability to easily see and reach components. A list of user-system requirements was initially prepared to guide decisions affecting the layout. Then, five design options depicting various ways to lay out the components were evaluated. Based on this effort, a best design option was identified for implementation. It is expected that the design recommended herein will provide the workers with a workplace that permits unhindered access to the components requiring their attention.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Review of Landscaping Equipment Vibration Risk Exposure, LLNL Site 200 (Various Locations), Whole Body Vibration Seated and Standing Mowers

WBV (Whole-Body Vibration) for operators of seated and standing lawn mowers was conducted during landscape activities from April 2019 through August 2019 at various locations around LLNL Site 200. Mowing is generally performed by each landscaper for 2-3 days every other week with a maximum duration of 3-5 hours each day. On mowing days, other tasks are performed for the remainder of the day that do not expose the worker to WBV such as irrigation, blowing, or sweeping. The mowing terrain at LLNL is variable with typical reported conditions such as gopher holes, exposed tree roots, quick turns, normal and high growth, weeds, and mushy/wet ground that can result in jolts to the mower operator. The Larson Davis HVM200 seat pad with tri-axial accelerometer was used for monitoring workers. For the seated mowers, the HVM200 seat pad with tri-axial accelerometer was placed on the seat between the user and seat pan of the mower. For standing mowers, the seat pad with tri-axial accelerometer was wrapped with Dycem (for seat pad protection) and placed directly on top of the mower deck and underneath the end-user’s right foot. Monitoring for WBV was conducted while operators used different types, makes, and models of mowers. A total of sixteen samples were collected from the operators of seated mower and 6 samples were collected from operators of standing mower. This initial data sampling was part of a discovery phase to identify if WBV exposure met the 2016 ACGIH TLVs (Threshold Limit Values). This initial data identified that workers operating the mowers do not exceed either the TLV or Action Level (AL) for Weighted Acceleration Levels (A(8)) but typically exceed the Vibration Dose Value (VDV) lower boundary for the standing mowers.

59 BASIC BIOLOGICAL SCIENCES↗

Celebrating Native American Heritage Month: Area’s earliest inhabitants become valuable part of Lab workforce

By the time the then-secret laboratory was established in Los Alamos in 1943, the nearby pueblos we know today were well-established communities. To complete its wartime mission to build the world’s first nuclear weapons, the Laboratory needed many workers for all aspects of the project. As such, many Native Americans were hired to work at the Lab in various roles, such as technicians, researchers, machinists, and support staff. By the end of the Manhattan Project in 1945, shortly after the end of World War II, many friendships had been forged between employees from the pueblos and other workers at Los Alamos. This was evidenced by gatherings, such as a post-war celebration at the San Ildefonso Pueblo, as well as individual relationships between Lab staff and pueblo residents. Meanwhile, pueblo residents remained on as valuable members of the post-war Lab staff with additional workers hired as well. In honor of November’s Native American Heritage Month, staff at the National Security Research Center are taking a look back to LANL’s early workforce and the contributions -- both to our mission and our cultural enrichment -- made by Native Americans.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Tier 2 Safety Basis Document: Weapons and Complex Integration - Building 225

This Safety Basis Document (SBD) covers operations in the Weapons and Complex Integration (WCI) Building 225 (B225) facility. B225 is located in the southwestern quadrant of Lawrence Livermore National Laboratory (LLNL) and is operated and owned by WCI. This SBD satisfies the requirements of LLNL ES&H Manual Document 3.1, Nonnuclear Safety Basis Program (Ref. 2). B225 is classified as a Low Hazard Facility based on the inventory of radiological materials. Other hazards in B225: chemicals, radiation generating devices, and industrial hazards are managed at the Light Science and Industry (LSI) level. Biological and explosive hazards are not authorized in B225. There are four general Administrative Controls (ACs) identified as the B225 Operational Safety Requirements (OSRs). These administrative controls are deemed sufficient to ensure safe operations with respect to co-located workers and the public. Other safety features and administrative requirements are required by the LLNL ES&H Manual, including those to protect the facility workers and the environment, but these have not been selected as credited controls to protect the co-located workers or the public, which are the target populations of concern for the SBD.

61 RADIATION PROTECTION AND DOSIMETRY↗

User’s Manual for RESRAD-BUILD Code V.4: Vol. 1 – Methodology and Models Used in RESRAD-BUILD Code

The RESRAD-BUILD computer code models radionuclide release and transport in indoor environments and performs pathway analyses to evaluate the potential radiological dose and risk incurred by an individual who works or lives in a building contaminated with radioactive material or housing radioactively contaminated furniture or equipment. The code provides four geometries to characterize a radiation source: point, line, area, and volume, in which radionuclides are homogeneously distributed. Radionuclides contained in a source are considered to be released to the indoor air due to various processes including erosion (mechanically or weathering), diffusion (for tritium and radon in a volume source), or emanation (radon in a point, line, or area source). The release can proceed through different time phases with different rates. In RESRAD-BUILD Version 4.0, a dynamic ventilation model is implemented to simulate the fate and transport of source material particles and radionuclides after their releases. This dynamic ventilation model considers (1) air exchange between rooms in the building and between the rooms and the outdoor environment, (2) deposition from air to floor, (3) resuspension from the floor to the air, and (4) periodical vacuuming that reduces the floor deposition. The fate and transport modeling provides estimates of radionuclide concentrations in the source, in the air, and on the floor at different times, which are then integrated over the exposure duration for the calculation of radiation doses and cancer risks. A single run of the RESRAD-BUILD code can model a building with up to 9 rooms, 10 sources, and 10 receptors. The potential radiation dose and cancer risk incurred by each receptor are calculated for seven exposure pathways: (1) external radiation directly from the sources (accounting for shielding), (2) external radiation from radioactive particles deposited on the floors, (3) external radiation from airborne radionuclides, (4) inhalation of airborne radionuclides, (5) inhalation of radon and radon progenies, (6) inadvertent ingestion of radioactive particles directly from the source, and (7) ingestion of radioactive particles deposited on the floors. Various exposure scenarios can be modeled with RESRAD-BUILD, including but are not limited to, office worker, renovation worker, decontamination worker, building visitor, and resident. Both deterministic and probabilistic analyses can be performed to obtain results in both text reports and graphic displays.

61 RADIATION PROTECTION AND DOSIMETRY↗

Accidental Disassembly of a Multi Branch Outlet Strip with Surge Protector (Investigation Report)

On December 16 a worker attempted to disconnect a computer plug from a multi outlet surge protector strip. The plastic housing of the surge protector disintegrated while the plug was pulled exposing the bare conductors of the internal wiring. The worker disconnected the wall plug on the multi outlet strip and de-energized the outlet strip. The worker contacted the FOD and the FOD called the ISR DESO for advice. The DESO collected the pieces and performed an autopsy on the device.

42 ENGINEERING↗

Radon Survey of Los Alamos National Laboratory Buildings and Los Alamos County Residential Buildings

A radon survey of office spaces was of interest to LANL for several reasons. First, exposure to natural radon in LANL office spaces has been considered to be outside the regulatory reach of the federal regulations and the U.S. Department of Energy (U.S. DOE) orders, and thus has not been studied as extensively as occupational exposure to other radionuclides and is not subject to the same rigorous radiological controls. Second, a general survey of radon concentrations in LANL workspaces was of interest to management to ensure safe environments for workers and is in keeping with the intent of OSHA requirements. Though radon in LANL offices would not be derived from enhanced radioactive sources, radon exposure in general office spaces has the potential to significantly impact worker risk. The purpose of the 2009 radon survey was to measure and document indoor radon levels across a broad spectrum of office-type workspaces and neighboring homes. The measured concentrations were compared against those measured across the United States and across the world. The results were also compared against a wide variety of radiation protection thresholds such as (1) the action levels of 148 Bq m -3 (the U.S. EPA action level for public housing), (2) ≈1,200 Bq m -3 OSHA threshold for office spaces, (3) effective dose threshold of 1 mSv threshold for defining a radiological worker, (4) 50 mSv occupational effective dose limit, and (5) 0.1 mSv and 1 mSv limits for public exposures from the air pathway and all pathways, respectively.

07 ISOTOPE AND RADIATION SOURCES↗

Ventilation: Fume Hoods Self-Study Course # 48002

This course presents an overview of the requirements and safe work practices for the use of engineered ventilation controls (EVCs) at Los Alamos National Laboratory (LANL). EVCs addressed in this manual include fume hoods, local exhaust ventilation (LEV) systems other than fume hoods, portable and in-place high-efficiency particulate air (HEPA) filtration systems. Requirements from LANL Procedure P101-16, Industrial Ventilation (non-HVACR) that address EVC certification and use, along with responsibilities of workers who use EVCs and the responsible line managers (RLMs) of such workers, are also presented. Per 101-16, 6.1, workers who use, maintain, or certify (i.e., inspect and test) fume hoods, or Persons in Charge (PICs) who oversee others in those tasks, must complete this course.

42 ENGINEERING↗

Motion Planning Algorithms for Safety and Quantum Computing Efficiency

Motion planning remains a fundamental problem in robotics. Sampling-based algorithms use randomization to allow efficient solutions to this complex problem. As mobile robots and autonomous vehicles become more prevalent in everyday life, motion planning must be applied to increasingly challenging scenarios. Safety has become a paramount concern in motion planning for ensuring robotic applications enrich human lives. To date, many motion planning techniques to increase safety in the face of uncertain and dynamic environments have been developed. This dissertation first addresses distributional safety of Rapidly-Exploring Random Trees (RRT) through our algorithm W-Safe RRT. To acknowledge distributional uncertainty and poor modeling, W-Safe RRT uses the Wasserstein metric to provide a probabilistic bound on the distributional distance between a robot and obstacles. Human-interpretable environmental agent classification allows online safety margin adaptation. We propose and analyze an integrating region method for online classification that increases actor labeling accuracy based on behavioral feature values when compared to state of the art methods. The method performs class assignments based on local maximum likelihood in a created behavioral feature-space, allowing a notion of classification uncertainty. Model-based methods with safety guarantees can quickly become computationally in tractable, especially with multiple agents, higher dimensions, and plentiful unknowns. Sampling based algorithms have been parallelized for computation with multi-core computers and GPUs. We consider the use of quantum algorithms and computers for sampling-based motion planning for the first time. Quantum computing performs operations on superpositions of states and can solve certain problems much more efficiently than classical computers, but introduces previously unseen challenges. With Quantum-RRT, we recast the motion planning problem into a database-search structure and use Quantum Amplitude Amplification to find reachable states in the database with a quadratic performance increase over classical methods. We address two error sources with this method: quantum measurement and quantum oracle errors. We then extend this method to Parallel Quantum-RRT, which uses a manager-worker architecture with multiple parallel quantum workers to increase database search efficiency. We compare algorithm architectures and characterize probabilities of multiple workers finding solutions. Lastly, we test in simulation the quantum algorithms against classical versions in a wide variety of scenarios, concluding that a similar parallelization improvement is to be found in the quantum case as was found in the parallelization of classical RRT.

97 MATHEMATICS AND COMPUTING↗

Supporting Growth of a Skilled Workforce in the Building Energy Efficiency Industry (Final Technical Report)

The Interstate Renewable Energy Council (IREC), having worked for well over a decade to develop national networks and best practices focused on attracting and training high quality workers for the clean energy industries, sought to address shortfalls in skilled workers who build, retrofit, operate, and maintain energy efficient buildings. Through this project, IREC created and promoted a Green Buildings Career Map (GBCM)—a career awareness and recruitment tool—that seeks to boost the nationwide growth of workers entering the energy efficiency (EE) industry. Working with a team of subject matter experts and our partner organizations—Building Performance Association (BPA), Building Performance Institute (BPI), Community Action Partnership (CAP), and the National Institute of Building Sciences (NIBS)—IREC produced an interactive, engaging career map to attract and motivate individuals into pursuing careers in energy efficiency, and in support of the Weatherization Assistance Program. The GBCM was designed for a broad audience including educators, career advisors, employers, policymakers, workforce professionals, and jobseekers who may otherwise have little or no awareness of the exciting and rewarding opportunities within targeted industry sectors. Most individuals seeking careers do not know about the breadth of careers awaiting them in the built environment and the same is true for most career and guidance counselors, educators, and parents. The GBCM provides this broad audience with a vision of the myriad jobs that could lead to a long-standing career in energy efficiency. The GBCM describes diverse occupations across the EE industry, charts possible progression between those occupations, and identifies the training, skills, and credentials necessary to do them well.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fall Protection Introduction: Participant Guide

Worker safety is paramount at Los Alamos National Laboratory (LANL). According to the U.S. Bureau of Labor and Statistics, an estimated 671 workers are killed and approximately 58,000 injured on the job each year due to fall-related events. Therefore, ensuring that workers are provided with proper training and protection is critical. This module presents examples of activities that require fall protection, fall protection regulations and requirements, key definitions associated with fall protection, and training requirements for employees engaged in activities that require fall protection.

99 GENERAL AND MISCELLANEOUS↗

The Challenges of Safe Troubleshooting Work

Troubleshooting work presents electrical and other workers with a challenging combination of physical hazards, working conditions, and time pressure, which can lead to unwanted outcomes if not carefully managed. Summaries of several incidents in which workers were injured or at risk of injury while performing troubleshooting work are presented, identifying organizational weaknesses and error precursors that contributed to each incident. The primary challenges include: Deranged equipment. Equipment that needs troubleshooting is not in a normal operating condition. Actions that are safe when the equipment is in a normal state may not be safe in the deranged state. Work planning and control. The steps taken in troubleshooting are most often determined by the results of the immediately previous diagnostic test, making effective work planning challenging. Multiple types of hazards. Most equipment will present a troubleshooting worker with several types of hazards, including hazardous energy as defined in 29 CFR 1910.147. Portions of the troubleshooting activity may be infeasible without these hazards present. Time pressure. Restoring operation of failed equipment often involves an explicit or implicit sense of urgency. There are effective methods for addressing each challenge, most of which require a combination of advance preparation and management commitment.

Mertz, David E.↗

When and Why Hiring and Training Occur: A Survey of Building Efficiency Contractors

As state and local governments, along with homeowners, work to enhance building energy performance, a sufficiently skilled energy-efficiency workforce is essential for implementing solutions at scale. In recent years, employers in the energy efficiency sector, including building performance contractors, have frequently reported challenges finding qualified workers. Additionally, as building performance technologies evolve and become more sophisticated, current workers need to acquire new skills and practices to maintain high-quality work. This study surveyed 209 contractors involved in building energy performance projects across 37 U.S. states, Washington, D.C., Guam, and the Marshall Islands. The survey aimed to understand their experiences in the labor market, their business practices, and their decision-making processes when hiring new workers and training existing employees. The findings highlight contractors' motivations and considerations in hiring and training, as well as the most significant challenges they face in the labor market. These insights can help workforce development practitioners design training programs that are aligned with workforce needs and responsive to employer concerns.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗