Search NASA⌕ Search

SEARCH · Search NASA

Results for “capillary”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Thermal modulation for gas chromatography

A thermal modulator device for gas chromatography and associated methods. The thermal modulator device includes a recirculating fluid cooling member, an electrically conductive capillary in direct thermal contact with the cooling member, and a power supply electrically coupled to the capillary and operable for controlled resistive heating of the capillary. The capillary can include more than one separate thermally modulated sections.

Hasselbrink, Ernest F.↗

Improved Devices for Collecting Sweat for Chemical Analysis

Improved devices have been proposed for collecting sweat for biochemical analysis - especially for determination of the concentration of Ca2+ ions in sweat as a measure of loss of Ca from bones. Unlike commercially available sweat-collection patches used previously in monitoring osteoporosis and in qualitative screening for some drugs, the proposed devices would not allow evaporation of the volatile chemical components (mostly water) of sweat. Moreover, the proposed devices would be designed to enable determination of the volumes of collected sweat. From these volumes and the quantities of Ca(2+) and/or other analytes as determined by other means summarized below, one could determine the concentrations of the analytes in sweat. A device according to the proposal would be flexible and would be worn like a commercial sweat-collection patch. It would be made of molded polydimethylsiloxane (silicone rubber) or other suitable material having properties that, for the purpose of analyzing sweat, are similar to those of glass. The die for molding the silicone rubber would be fabricated by a combination of lithography and electroplating. The die would reproducibly form, in the silicone rubber, a precisely defined number of capillary channels per unit area, each channel having a precisely defined volume. Optionally, electrodes for measuring the Ca(2+) content of the sweat could be incorporated into the device. The volume of sweat collected in the capillary channels of the device would be determined from (1) the amount of light or radio waves of a given wavelength absorbed by the device and (2) the known geometry of the array of capillary channels. Then, in one of two options, centrifugation would be performed to move the sweat from the capillary tubes to the region containing the electrodes, which would be used to measure the Ca(2+) content by a standard technique. In the other option, centrifugation would be performed to remove the sweat from the device to make the sweat available to other analytical instruments for measuring concentrations of substances other than Ca(2+).

Feedback, Daniel L.↗

Improved Devices for Collecting Sweat for Chemical Analysis

Improved devices have been proposed for collecting sweat for biochemical analysis especially for determination of the concentration of Ca2+ ions in sweat as a measure of loss of Ca from bones. Unlike commercially available sweat-collection patches used previously in monitoring osteoporosis and in qualitative screening for some drugs, the proposed devices would not allow evaporation of the volatile chemical components (mostly water) of sweat. Moreover, the proposed devices would be designed to enable determination of the volumes of collected sweat. From these volumes and the quantities of Ca2+ and/or other analytes as determined by other means summarized below, one could determine the concentrations of the analytes in sweat. A device according to the proposal would be flexible and would be worn like a commercial sweat-collection patch. It would be made of molded polydimethylsiloxane (silicone rubber) or other suitable material having properties that, for the purpose of analyzing sweat, are similar to those of glass. The die for molding the silicone rubber would be fabricated by a combination of lithography and electroplating. The die would reproducibly form, in the silicone rubber, a precisely defined number of capillary channels per unit area, each channel having a precisely defined volume. Optionally, electrodes for measuring the Ca2+ content of the sweat could be incorporated into the device. The volume of sweat collected in the capillary channels of the device would be determined from (1) the amount of light or radio waves of a given wavelength absorbed by the device and (2) the known geometry of the array of capillary channels. Then, in one of two options, centrifugation would be performed to move the sweat from the capillary tubes to the region containing the electrodes, which would be used to measure the Ca2+ content by a standard technique. In the other option, centrifugation would be performed to remove the sweat from the device to make the sweat available to other analytical instruments for measuring concentrations of substances other than Ca2+.

Feeback, Daniel L.↗

Pressure Profiles in a Loop Heat Pipe Under Gravity Influence

During the operation of a loop heat pipe (LHP), the viscous flow induces pressure drops in various elements of the loop. The total pressure drop is equal to the sum of pressure drops in vapor grooves, vapor line, condenser, liquid line and primary wick, and is sustained by menisci at liquid and vapor interfaces on the outer surface of the primary wick in the evaporator. The menisci will curve naturally so that the resulting capillary pressure matches the total pressure drop. In ground testing, an additional gravitational pressure head may be present and must be included in the total pressure drop when LHP components are placed in a non-planar configuration. Under gravity-neutral and anti-gravity conditions, the fluid circulation in the LHP is driven solely by the capillary force. With gravity assist, however, the flow circulation can be driven by the combination of capillary and gravitational forces, or by the gravitational force alone. For a gravity-assist LHP at a given elevation between the horizontal condenser and evaporator, there exists a threshold heat load below which the LHP operation is gravity driven and above which the LHP operation is capillary force and gravity co-driven. The gravitational pressure head can have profound effects on the LHP operation, and such effects depend on the elevation, evaporator heat load, and condenser sink temperature. This paper presents a theoretical study on LHP operations under gravity neutral, anti-gravity, and gravity-assist modes using pressure diagrams to help understand the underlying physical processes. Effects of the condenser configuration on the gravitational pressure head and LHP operation are also discussed.

0000↗

Pressure Profiles in a Loop Heat Pipe under Gravity Influence

During the operation of a loop heat pipe (LHP), the viscous flow induces pressure drops in various elements of the loop. The total pressure drop is equal to the sum of pressure drops in vapor grooves, vapor line, condenser, liquid line and primary wick, and is sustained by menisci at liquid and vapor interfaces on the outer surface of the primary wick in the evaporator. The menisci will curve naturally so that the resulting capillary pressure matches the total pressure drop. In ground testing, an additional gravitational pressure head may be present and must be included in the total pressure drop when LHP components are placed in a non-planar configuration. Under gravity-neutral and anti-gravity conditions, the fluid circulation in the LHP is driven solely by the capillary force. With gravity assist, however, the flow circulation can be driven by the combination of capillary and gravitational forces, or by the gravitational force alone. For a gravity-assist LHP at a given elevation between the horizontal condenser and evaporator, there exists a threshold heat load below which the LHP operation is gravity driven and above which the LHP operation is capillary force and gravity co-driven. The gravitational pressure head can have profound effects on the LHP operation, and such effects depend on the elevation, evaporator heat load, and condenser sink temperature. This paper presents a theoretical study on LHP operations under gravity-neutral, anti-gravity, and gravity-assist modes using pressure diagrams to help understand the underlying physical processes. Effects of the condenser configuration on the gravitational pressure head and LHP operation are also discussed.

Thermal Control Systems↗

Testing of a Helium Loop Heat Pipe for Large Area Cryocooling

Future NASA space telescopes and exploration missions require cryocooling of large areas such as optics, detector arrays, and cryogenic propellant tanks. One device that can potentially be used to provide closed-loop cryocooling is the cryogenic loop heat pipe (CLHP). A CLHP has many advantages over other devices in terms of reduced mass, reduced vibration, high reliability, and long life. A helium CLHP has been tested extensively in a thermal vacuum chamber using a cryocooler as the heat sink to characterize its transient and steady performance and verify its ability to cool large areas or components in the 3K temperature range. A copper plate with attached electrical heters was used to simulate the heat source, and heat was collected by the CLHP evaporator and transferred to the cryocooler for ultimate heat rejection. The helium CLHP thermal performance test included cool-down from the ambient temperature, startup, capillary limit, heat removal capability, rapid power changes, and long duration steady state operation. The helium CLHP demonstrated robust operation under steady state and transient conditions. The loop could be cooled from the ambient temperature to subcritical temperatures very effectively, and could start successfully without pre-conditioning by simply applying power to both the capillary pump and the evaporator plate. It could adapt to rapid changes in the heat load, and reach a new steady state very quickly. Heat removal between 10mW and 140mW was demonstrated, yielding a power turn down ratio of 14. When the CLHP capillary limit was exceeded, the loop could resume its normal function by reducing the power to the capillary pump. Steady state operations up to 17 hours at several heat loads were demonstrated. The ability of the helium CLHP to cool large areas was therefore successfully verified.

Crycooling↗

Testing of a Helium Loop Heat Pipe for Large Area Cryocooling

Future NASA space telescopes and exploration missions require cryocooling of large areas such as optics, detector arrays, and cryogenic propellant tanks. One device that can potentially be used to provide closed-loop cryocooling is the cryogenic loop heat pipe (CLHP). A CLHP has many advantages over other devices in terms of reduced mass, reduced vibration, high reliability, and long life. A helium CLHP has been tested extensively in a thermal vacuum chamber using a cryocooler as the heat sink to characterize its transient and steady performance and verify its ability to cool large areas or components in the 3K temperature range. A copper plate with attached electrical heaters was used to simulate the heat source, and heat was collected by the CLHP evaporator and transferred to the cryocooler for ultimate heat rejection. The helium CLHP thermal performance test included cool-down from the ambient temperature, startup, capillary limit, heat removal capability, rapid power changes, and long duration steady state operation. The helium CLHP demonstrated robust operation under steady state and transient conditions. The loop could be cooled from the ambient temperature to subcritical temperatures very effectively, and could start successfully without pre-conditioning by simply applying power to both the capillary pump and the evaporator plate. It could adapt to rapid changes in the heat load, and reach a new steady state very quickly. Heat removal between 10mW and 140mW was demonstrated, yielding a power turn down ratio of 14. When the CLHP capillary limit was exceeded, the loop could resume its normal function by reducing the power to the capillary pump. Steady state operations up to 17 hours at several heat loads were demonstrated. The ability of the helium CLHP to cool large areas was therefore successfully verified.

cryocooling↗

Thermal Vacuum Testing of a Helium Loop Heat Pipe for Large Area Cryocooling

Future NASA space telescopes and exploration missions require cryocooling of large areas such as optics, detector arrays, and cryogenic propellant tanks. One device that can potentially be used to provide closed-loop cryocooling is the cryogenic loop heat pipe (CLHP). A CLHP has many advantages over other devices in terms of reduced mass, reduced vibration, high reliability, and long life. A helium CLHP has been tested extensively in a thermal vacuum chamber using a cryocooler as the heat sink to characterize its transient and steady performance and to verify its ability to cool large areas or components in the 3 degrees Kelvin temperature range. The helium CLHP thermal performance test included cool-down from the ambient temperature, startup, capillary limit, heat removal capability, rapid power changes, and long duration steady state operation. The helium CLHP demonstrated robust operation under steady state and transient conditions. The loop could be cooled from the ambient temperature to subcritical temperatures very effectively, and could start successfully by simply applying power to both the capillary pump and the evaporator plate without pre-conditioning. It could adapt to a rapid heat load change and quickly reach a new steady state. Heat removal between 10 megawatts and 140 megawatts was demonstrated, yielding a power turn down ratio of 14. When the CLHP capillary limit was exceeded, the loop could resume its normal function by reducing the power to the capillary pump. Steady state operations up to 17 hours at several heat loads were demonstrated. The ability of the helium CLHP to cool large areas was therefore successfully verified.

Thermal Control Systems↗

Final Report Document: Microgravity Medical Eyewash B

Senior Capstone Design Team 15 has been commissioned by the National Aeronautics and Space Administration (NASA) to redesign the current microgravity eye wash station. The current design exhibits four primary limitations: single-use operation, excessive mass and volume, operational complexity requiring coordination with external systems, and dependence on frequent Earth resupply missions. Our updated eyewash design will be deployed on long-range space missions that could last multiple years. Based on these and other requirements from our customer, we have developed our updated eyewash design. Our compact, single-eye system uses capillary-driven flow and a free-floating water ball. This design allows us to eliminate pumps and bulky tubing, decreasing the mass and volume of the overall system. The containment eyecup is held to the astronaut's face with a strap, and a silicone seal prevents leakage while improving user comfort. Contaminated water is contained within a disposal bag containing wicking material to pull it back out of the eyecup after washing the eye. This system is reusable, efficient, and easy to activate quickly. We evaluated our design through calculations, microfluidic testing, and user try-on testing to verify our requirements. Our work demonstrated that steady-state flow was capable with our capillary framework, achieving 1.31 L/min. The prototype construction confirmed mass and volume reductions, and try-on-testing evaluated the ability to put on the system quickly. Almost all major design requirements were achieved, and water loss could be validated by testing in microgravity. Our design went through a number of iterations to reach the final solution presented in this report. These changes were driven by our testing and collaboration from each member of the team. Updated models optimized tube placement and geometry of the eyecup to better direct flow as it pools across the eye. Changes to our tubing bends improved capillary efficiency and increased the flow rate we were capable of achieving. And improved bracket placements adjusted the fit, comfort, and seal of the eyecup to the astronaut's face. Our capillary-based eyewash system is technically feasible and has been theoretically validated to operate effectively in microgravity conditions. Testing and analysis indicate that it can meet or exceed the required performance metrics, including flow rate and safety constraints. Overall, the design represents a viable alternative to current ISS-dependent eyewash systems for future space missions.

Jeffrey Allen↗

Numerical investigation of multiphase flow through self-affine rough fractures

Multiphase flow through fractures has great significance in subsurface energy recovery and gas storage applications. Different fracture and flow properties affect flow through a fracture which is difficult to control in laboratory experiments. Here, we perform lattice Boltzmann simulations in an ensemble of synthetically generated fractures. Drainage simulations are performed at different capillary numbers, wettability, and viscosity ratios. We track the invading front and quantify breakthrough saturations and show that roughness and wettability have a strong effect on fluid invasion through a complex fracture. Invading a more viscous fluid results in more stable displacement regardless of the capillary number while at very low capillary numbers, fluid migration is dependent on the inherent structure of the fracture. We develop a fluid displacement phase diagram in a single rough fracture and compare our results from that in the literature. Finally, we extend the phase diagrams across multiple fractures and demonstrate the importance of natural fracture features of roughness and wettability in identifying stable versus unstable displacement regimes during multiphase flow through rough fractures. Our work presents an end-to-end numerical pathway for testing on experimental data and expanding numerical data sets for testing combinations of different physical phenomenon and make valuable predictions on fluid flow through rough fractures.

02 PETROLEUM↗

Modeling Geologic Waste Repository Systems Below Residual Saturation

The heat generated by high-level radioactive waste can pose numerical and physical challenges to subsurface flow and transport simulators if the liquid water content in a region near the waste package approaches residual saturation due to evaporation. Here, residual saturation is the fraction of the pore space occupied by liquid water when the hydraulic connectivity through a porous medium is lost, preventing the flow of liquid water. While conventional capillary pressure models represent residual saturation using asymptotically large values of capillary pressure, here, residual saturation is effectively modeled as a tortuosity effect alone. Treating the residual fluid as primarily dead-end pores and adsorbed films, relative permeability is independent of capillary pressure below residual saturation. To test this approach, PFLOTRAN is then used to simulate thermal-hydrological conditions resulting from direct disposal of a dual-purpose canister in unsaturated alluvium using both conventional asymptotic and revised, smooth models. Importantly, while the two models have comparable results over 100 000 years, the number of flow steps required is reduced by approximately 94%.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Role of Phytoplankton Biomacromolecules in Controlling Ocean Surface Roughness

Satellite altimetric data routinely map sea surface topography by measuring the ocean return signal. One source of altimeter measurement contamination occurs when the radar ocean backscatter becomes unusually large, a situation termed a Sigma-0 bloom. Past research suggests Sigma-0 blooms are associated with weak wind and natural surface slick conditions where capillary waves at the air–sea interface are suppressed. To date, no explicit connection between these conditions and Sigma-0 bloom presence has been provided. Using a series of simplified equations, our reduced model determines capillary wave heights from estimates of planktonic carbon concentrations and regional wind speed. Our results suggest that the radar signal reflection increases as capillary wave height decreases. This relationship depends on surfactant concentration, surfactant composition, and wind speed. Model sensitivity analysis indicates that the interface reflectivity depends on biological activity and wind speed. Our proposed simplified model provides a method to identify potential Sigma-0 bloom regions. We conclude that because of the demonstrated impact of biological surfactants on ocean roughness, it is necessary to consider the biological activity, i.e., phytoplankton bloom events, when interpreting signals from radar altimetry and when developing ocean hydrology models.

54 ENVIRONMENTAL SCIENCES↗

The Plant Water Management Experiments: Soil

A simple means of watering plants in the low-g environment aboard orbiting spacecraft is not obvious. Since the beginning of spaceflight, numerous approaches have been pursued to water plants that seek to maximize plant viability and system reliability, while minimizing crew time and system complexity. We are not there yet. The Plant Water Management (PWM) Soil experiments seek to apply recent advances in low-g capillary fluidics phenomena to the challenges faced by plant growth operations aboard spacecraft. The primary challenge is to establish earth-like flows minimizing low-g specific adaptations required of the plants. This is difficult due to the ever-present fluid physics challenges of poorly-wetting multiphase inertial-visco-capillary flows in geometrically complex conduits and containers. In this paper, we present recent flight results for the PWM Soil experiments where arcillite ‘soil reservoirs’ are arranged in a non-wetting host soil that serves as an O2-breathing wetting barrier. In this way, a largely terrestrial water-soil environment is mimicked where, as liquid is evapo-transpired through the growing plant foliage, the effective water table passively ‘falls’ reducing viscous lengths and increasing water uptake for the plant. We present data from 6 days of 24-7 experiments on the ISS testing 3 different plant root models. We also present and correlate a capillary flow model which captures the primary features of the flow. Our summary is valued for the assessment of current and future low-g plant watering systems employing soil media.

microgravity↗

Numerical analysis of Microgravity Bubble Separation in Open Channels with ISS Bemchmarks

Spacecraft fluid systems often require specific considerations to operate in a manner similar to those on Earth. For instance, an open wedge shaped channel can serve as a pathway for passively separating bubbles from a liquid in a two phase flow, analogous to buoyancy effects on Earth. As the bubbles merge within the channel, they become increasingly confined in the wedge, driving them upwards and outwards toward the free surface due to capillary forces. These same forces ensure coalescence and allow the bubbles to escape through the free surface. However, in low gravity environments, a challenge arises when bubbles are not sufficiently large. Under such conditions, the bubbles tend to follow trajectories near their inscribed elevations, never fully leaving the liquid. Such unseparated bubbles can lead to downstream pump failure, cavitation, flow instabilities, dryout, and other adverse effects aboard spacecraft. Understanding and exploiting the underlying mechanisms behind this behavior is crucial for enhancing the reliability of passive capillary fluids management in space applications, including cryogenic and storable fuels transport, thermal fluids circulation, water recycling for life support, plant watering systems, and more. The joint German Aerospace Center (DLR) and NASA Capillary Channel Flow (CCF) experiment conducted on the International Space Station has provided an extensive publicly available database documenting such phenomena (https://science.nasa.gov/physical sciences informatics psi). Leveraging this resource, we aim to establish benchmarks for our numerical investigation of zero gravity bubbly two phase flow in open wedge channels. Specifically, we seek to quantitatively understand the mechanisms governing ‘inscribed’ bubble motion, considering the apparent interplay of two competing forces: Saffman lift (causing upward/outward motion) and the Magnus effect (causing downward/inward motion). Our cross cutting findings directly inform the development of robust passive phase separation methods within spacecraft plumbing systems.

bubble↗

Enhancing predictive understanding and accuracy in geological carbon dioxide storage monitoring: Simulation and history matching of tracer transport dynamics

Co-injection of conservative tracers with carbon dioxide (CO 2 ) is a viable tool for monitoring subsurface processes during geological CO 2 storage (GCS). This research investigates the simulation and history-matching of a gas tracer (sulfur hexafluoride, SF 6 ) during CO 2 flooding, employing a core flooding result in Berea sandstone. Four extensively used saturation functions are assessed for their efficacy in history matching of CO 2 /SF 6 injection at the core scale. The history-matching process incorporates particle swarm optimization (PSO) to fine-tune constitutive relationships parameters. Next, employing transport models at the aquifer scale, we interrogate the impact on tracer transport and mixing of saturation function uncertainties, arising from the non-uniqueness of constitutive relationships parameters and saturation function types. To assess the effects of geological heterogeneity on behavior of tracer breakthrough curves (BTCs), we employ two normalized parameters assessing the degree of mixing and SF 6 breakthrough time. The aquifer-scale investigation encompasses both homogeneous and heterogeneous systems with and without capillary heterogeneity effects. Our findings underscore the critical importance of addressing saturation function uncertainties, emphasizing the significance of auxiliary experiments and innovative methodologies to enhance predictive accuracy. The findings highlight significant disparities in arrival times, BTC peaks, tails, and mixing levels, even under optimal conditions. Heterogeneity, with or without capillary heterogeneity, plays a crucial role in shaping BTC variations, resulting in accelerated SF 6 breakthrough times and reduced BTC peaks. Evaluation of monitoring points distant from the injector reveals a dampening effect on the SF6 BTC peak, particularly in heterogeneous systems with capillary heterogeneity, where the peak is halved. These insights underscore the challenges associated with tracer monitoring and the necessity for enhanced methodologies to improve predictive accuracy in subsurface processes during GCS.

58 GEOSCIENCES↗

Effects of alkali dosage and silicate modulus on autogenous shrinkage of alkali-activated slag cement paste

Autogenous shrinkage of alkali-activated slag cement (AASC) paste prepared with different levels of alkali dosage and silicate modulus (M{sub s}) is investigated. The results show that autogenous shrinkage of AASC paste increases at a decreasing rate with alkali dosage, which is attributed to enhanced capillary pore pressure and syneresis of C-A-S-H gels. Autogenous shrinkage of AASC paste with a constant alkali dosage increases as M{sub s} increases from 0.5 to 1.0, followed with a reduction as M{sub s} further increases to 2.0. Increasing M{sub s} initially enhances the capillary pore pressure due to the enhanced reaction degree, and promotes the formation of saturated capillary pores and viscoelasticity, which facilitates the autogenous shrinkage of AASC paste. However, excessive silicate in the activator retards the internal moisture consumption, and subsequently decreases the autogenous shrinkage of AASC paste. Furthermore, increasing M{sub s} can also intensify syneresis of C-A-S-H gels, contributing to the early-age autogenous shrinkage of AASC paste.

36 MATERIALS SCIENCE↗

Understanding the microstructural evolution of hypersaline cemented paste backfill with low-field NMR relaxation

Highlights: • Microstructural evolution of CPB, prepared with tap and hypersaline water, is monitored using low-field NMR relaxometry. • T{sub 1} and T{sub 2} NMR relaxation measurements compared with mechanical strength via UCS tests • Hypersaline mixing water results in slower structural evolution and lower mechanical strength. Cemented paste backfill (CPB) comprising mineral tailings, binders and mixing water is an important potential support material in the mining industry. As the mechanical properties of CPB are significantly influenced by its microstructural characteristics the development of measurement tools to better understand its pore structure evolution is important for its increased utilisation. This study reports the application of low-field nuclear magnetic resonance (NMR) relaxation time measurements to characterise the microstructural evolution of CPB materials over 56 days of hydration, contrasting common tap water and hypersaline water (~22 wt% salt) as mixing water. Distinct NMR relaxation time populations were evidenced within each CPB sample, revealing the presence of both capillary (T{sub 1,2} ≈ 10 ms) and gel pore water (T{sub 1,2} ≈ 300–500 μs), with time-dependent relaxation measurements facilitating characterisation of capillary pore structure evolution over the hydration period assessed. Hypersaline samples demonstrated a time-lag in this measured capillary pore evolution, relative to those hydrated with tap water, while pore structure evolution rates were observed to increase with increased CPB binder content. Further, both T{sub 1} and T{sub 2} NMR relaxation times were found to correlate with the uniaxial compressive strength of the CPB materials investigated, facilitating the formulation of a predictive correlation function between NMR relaxation characteristics and mechanical properties.

36 MATERIALS SCIENCE↗

Comprehensive parametric study of CO 2 sequestration in deep saline aquifers

Carbon dioxide injection in deep saline aquifers is a key method for permanently sequestering anthropogenic CO 2 . Here this study employs a reactive transport model to explore mineral precipitation/dissolution and its impact on reservoir properties in deep saline aquifers. We also assess capillary pressure and relative permeability hysteresis on various CO 2 trapping mechanisms. Results from this study reveal the significant influence of initial brine composition on mineral precipitation/dissolution. The dissolution and precipitation of minerals have different effects around the wellbores compared to the overall reservoir. Additionally, salt concentration (Ca ++ and Mg ++ ) and quartz surface area affect CO 2 mineralization, while Na + impacts halite precipitation, altering flow properties. The effect of capillary pressure is significant, as including the capillary pressure in the simulation case resulted in significantly improved CO 2 trapping, achieving almost total dissolution of the injected CO 2 in around 300 years. This study offers novel insights into the interactions of reservoir minerals, brine properties, and the injected CO 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗