Search NASA⌕ Search

SEARCH · Search NASA

Results for “irradiation testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Active cavity radiometer type IV

A new cavity pyrheliometer, the active cavity radiometer type IV (ACR IV), has been developed for the measurement of total solar optical irradiance. Analysis predicts its ability to measure at the solar constant level with 0.1% uncertainty in SI units. In comparison tests ACR IVs have consistently demonstrated 0.3% higher results than the World Radiometric Reference scale. A prototype has been tested, and a flight instrument has been developed and flown in a sounding rocket experiment to determine the solar constant. ACR IV instrumentation is being developed for flight experiments on the Spacelab I and Solar Maximum missions to monitor the total solar output of optical radiation as part of a long-term program to detect variations of climatological significance.

Willson, R. C.↗

Physical interpretation of variations in total solar irradiance

Radiometry from the Solar Maximum Mission and Nimbus 7 satellites has demonstrated that the solar constant varies at a peak-to-peak level of up to 0.2 percent on time scales of weeks. The rotation and evolution of dark spots and bright faculae across the sun's disk accounts for most of that variation. Reasonable explanations have been put forward to explain how the spot-blocked heat flow might be stored, and to explain the source of the intense radiation that gives rise to the increased irradiance produced by the bright magnetic faculae. Time-dependent models of the response of the solar convection zone to small perturbations also indicate that slower variations in total solar irradiance of comparable magnitude are likely. More precise observations of the total solar irradiance and radius over long time scales are required to demonstrate the existence of such climatologically relevant changes, and to test models that would enable the interpretation and prediction of these changes.

Foukal, P.↗

The Environmental Performance at Low Intensity, Low Temperature (LILT) of High Efficiency Triple Junction Solar Cells

A number of JPL missions, either active or in the p l d g stages, require the accurate LILT flew intensity - low temperate) climate of triple-junction solar. Although triple ignition LILT performance was reported as recently as 2002, there has been an evolutionary advance in cell technology by both U.S. space cell manufacturers that, for mission design purposes, effectively obsoletes the earlier data. As a result, JPL initiated a program to develop a database for the LILT performance of the new high performance triple junction solar cells. JPL obtained Emcore Advanced triple Juntion CIC assemblies and Spectrolab Ultra Triple Junction CIC assemblies. These cells were tested at temperature-intensity ranges designed to cover applications between 1 and 5.18 AU solar distances. 1 MeV electron irradiation from 25 E14 to 1 El5 w were performed on the cells to evaluate the combined effect of particulate radiation and LILT conditions. The effect of LILT conditions was observed to incur an increase in the variation of cell performances such that at simulted 5.18 AU conditions the average performance was approximately 30% with the best cells measuring between 32 and 34% efficiency. The 30% average efficiency compares with approximately 25% average efficiency measured on earlier technology triple junction solar cells.

triple junction↗

Irradiance calibration with solar diffuser

The sun's energy is used in combination of movable and fixed diffuser plates, windows and apertures which are positioned in a series of test sequences (modes) for reflectance monitoring and calibration without the use of man-made sources. There are three embodiments, or implementations, of the invention--one embodiment uses two diffusers--a working diffuser and a secondary diffuser--the second embodiment uses three diffusers, a working diffuser, a secondary diffuser and a reference diffuser--and the third embodiment uses two diffusers--a working diffuser and a secondary diffuser, the latter also functioning as a cover for the working diffuser. The movable diffusers are mounted on rotatable cones and, in all embodiments, the sun is blocked from reaching the diffusers when not in use. Thus, the sun is used as a stable source for calibration and monitoring and the sun/diffuser combination is used in such a way that the response of all elements of the optical subsystem of the TOMS can be unambiguously and efficiently characterized with high accuracy and precision.

Haring, Robert E.↗

Test Plan for a Calibration Demonstration System for the Reflected Solar Instrument for the Climate Absolute Radiance and Refractivity Observatory

The Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission addresses the need to observe high-accuracy, long-term climate change trends and to use decadal change observations as the most critical method to determine the accuracy of climate change. One of the major objectives of CLARREO is to advance the accuracy of SI traceable absolute calibration at infrared and reflected solar wavelengths. This advance is required to reach the on-orbit absolute accuracy required to allow climate change observations to survive data gaps while remaining sufficiently accurate to observe climate change to within the uncertainty of the limit of natural variability. While these capabilities exist at NIST in the laboratory, there is a need to demonstrate that it can move successfully from NIST to NASA and/or instrument vendor capabilities for future spaceborne instruments. The current work describes the test plan for the Solar, Lunar for Absolute Reflectance Imaging Spectroradiometer (SOLARIS) which is the calibration demonstration system (CDS) for the reflected solar portion of CLARREO. The goal of the CDS is to allow the testing and evaluation of calibration approaches , alternate design and/or implementation approaches and components for the CLARREO mission. SOLARIS also provides a test-bed for detector technologies, non-linearity determination and uncertainties, and application of future technology developments and suggested spacecraft instrument design modifications. The end result of efforts with the SOLARIS CDS will be an SI-traceable error budget for reflectance retrieval using solar irradiance as a reference and methods for laboratory-based, absolute calibration suitable for climate-quality data collections. The CLARREO mission addresses the need to observe high-accuracy, long-term climate change trends and advance the accuracy of SI traceable absolute calibration. The current work describes the test plan for the SOLARIS which is the calibration demonstration system for the reflected solar portion of CLARREO. SOLARIS provides a test-bed for detector technologies, non-linearity determination and uncertainties, and application of future technology developments and suggested spacecraft instrument design modifications. The end result will be an SI-traceable error budget for reflectance retrieval using solar irradiance as a reference and methods for laboratory-based, absolute calibration suitable for climate-quality data collections.

Thome, Kurtis↗

Reduction of intensity variations on a photovoltaic array with compound parabolic concentrators

The reduction of nonuniformities in the intensity distribution of light focused on a photovoltaic array by a compound parabolic concentrator is investigated. The introduction of small distortions into the surfaces of the reflector in order to diffuse the incident collimated light to fill the angular acceptance of the concentrator is calculated by means of ray tracing to decrease the irradiance nonuniformity at the cost of a lowered effective concentration of the concentrator. Measurements of the intensity distribution on a scale test model in terrestrial sunlight with corrugated aluminized mylar reflectors are shown to be in good agreement with the ray tracing results. A two-stage concentrator consisting of a focusing primary and a nonimaging secondary is also shown to result in a fairly uniform intensity distribution except in the case of a 4-deg incidence angle, which may be corrected by the introduction of distortions into one or both concentration stages.

Greenman, P.↗

Gamma radiation effects on the dynamic fatigue measurements of glass discs

Circular specimens of low iron soda lime silicate glass were blasted with grit after having a circular notch etched into their centers. After separation into two groups, one group was exposed to gamma radiation. The fracture strengths of all samples were then tested by the biaxial technique, i.e., specimens were balanced on three balls and loaded in the center by a piston. The irradiated samples had received a 140,000 Gy dose from a Co-60 source. An enhanced interaction between the ambient moisture and the grit-blasted central notch was observed in the irradiated samples, which displayed accelerated corrosion.

Ananaba, T. O. J.↗

Effect of Ex Vivo Ionizing Radiation on Static and Fatigue Properties of Mouse Vertebral Bodies

For a variety of medical and scientific reasons, human bones can be exposed to a wide range of ionizing radiation levels. In vivo radiation therapy (0.05 kGy) is used in cancer treatment, and ex vivo irradiation (25-35 kGy) is used to sterilize bone allografts. Ionizing radiation in these applications has been shown to increase risk of fracture, decrease bone quality and degrade collagen integrity. Past studies have investigated the deleterious effects of radiation on cortical or trabecular bone specimens individually, but to date no studies have examined whole bones containing both cortical and trabecular tissue. Furthermore, a clear relationship between the dose and the mechanical and biochemical response of bone's extracellular matrix has yet to be established for doses ranging from cancer therapy to allograft sterilization (0.05-35 kGy). To gain insight into these issues, we conducted an ex vivo radiation study to investigate non-cellular (i.e. matrix) effects of ionizing radiation dose on vertebral whole bone mechanical properties, over a range of radiation doses (0.05-35 kGy), with a focus on any radiation-induced changes in collagen. With underlying mechanisms of action in mind, we hypothesized that any induced reductions in mechanical properties would be associated with changes in collagen integrity. METHODS: 20-week old female mice were euthanized and the lumbar spine was dissected using IACUC approved protocols. The lumbar vertebrae (L1- S1) were extracted from the spine via cuts through adjacent intervertebral discs, and the endplates, posterior processes, surrounding musculature, and soft tissues were removed (approx. 1.5mm diameter, approx. 2mm height). Specimens were randomly assigned to one of five groups for ex vivo radiation exposure: x-ray irradiation at 0.05, 1, 17, or 35 kGy, or a 0 kGy control. Following irradiation, the vertebrae were imaged using microcomputed tomography (micro-CT) and then subjected to either monotonic compressive loading to failure or uniform cyclic compressive loading. During cyclic testing, samples were loaded in force control to a force level that corresponded to a strain of 0.46%, as determined in advance by a linearly elastic micro-CT-based finite element analysis for each specimen. Tests were stopped at imminent fracture, defined as a rapid increase in strain. The main outcome for the monotonic test was the strength (maximum force); for cyclic testing it was the fatigue life (log of the number of cycles of loading at imminent failure). A fluorometric assay was used on the S1 vertebrae to measure the number of non-enzymatic collagen crosslinks[4]. A one-way ANOVA was performed on mechanical properties and collagen crosslinks; means were compared with controls using Dunnett's method, with a Tukey-Kramer post-hoc analysis when significance was found (p < or = 0.05). RESULTS: Compared to the unirradiated control group, the concentration of non-enzymatic collagen crosslinks was significantly increased for all irradiated groups (p < 0.0001), and being higher by at least 50% (Figure 1a). By contrast, the radiation effects on the collagen were only evident at the higher doses. For irradiation exposures of 17 kGy or more, strength decreased substantially as the radiation level was increased, but no effect was evident below 17 kGy (Figure 1b). There was no significant change in the stiffness or maximum displacement for any radiation dose (p>0.05). The finite element analysis prescribed force level for cyclic loading exceeded the measured (monotonic) strength of the 17 and 35 kGy irradiated groups (mean +/- SD, 20.6 +/- 5.6 N; 13.2 +/- 3.7 N, respectively) and therefore these groups were eliminated from the fatigue study. The fatigue life for the 0.05 and 1 kGy groups were similar to each other and were not statistically significantly different from the control group (Figure 1c).

radiation↗

Performance of AlGaAs, GaAs and InGaAs cells after 1 MeV electron irradiation

Electron irradiations were made on three different types of III-V cells. AlGaAs, GaAs, and InGaAs cells with bandgaps of approximately 1.72, 1.43, and 1.1 eV, respectively, were tested. All of the cells were concentrator cells and performance data from one sun to beyond 100x AMO were taken. The total 1 MeV electron fluence was 3 times 10 to the 15th power e/square cm with data taken at several intermediate fluences. Cell performance is presented as a function of electron fluence for various concentration ratios and two different temperatures (25 and 80 C). Since these three cell types are potential candidates for the individual cells in a cascade structure, it is possible to calculate the loss in performance of cascade cells under 1 MeV irradiation. Data are presented which show the calculated performance of both series-connected and separately connected cascade cells.

Curtis, Henry B.↗

Flight qualification test results for violet cells

The violet solar cell has been submitted to a flight qualification program. The tasks included in this program were: to define the violet cell's electrical output from -100 C to +100 C; to determine the violet cell's degradation under 2 MeV, 1 MeV and .3 MeV proton irradiation, under a high humidity environment and under ultraviolet light; to thermal cycle two similar modules of violet cells; to flight qualify a full size violet cell panel for the IMP-J flight; and to obtain a primary balloon-flown standard of the violet cell type. The results of these tests demonstrate that the violet cell is fully qualified for space flight use with no further development work. The tests show that the violet cell offers a power increase of at least twenty-one per cent over presently available commercial cells.

Gaddy, E. M.↗

Observations on degradation of UV systems on Nimbus spacecraft

Broad band photometer experiments in the 1200 to 3000 A have been operating on Nimbus 3 and 4 since April 1969 for the purpose of determining the nature of variations in the UV solar irradiance. An Ebert-Fastie double monochromator has been measuring the solar irradiance and earth radiance from 2500 to 3400 A for the determination of global atmospheric ozone distributions since April 1970. From prelaunch testing and an evaluation of the flight data it is concluded that the principal source of degradation is probably the spacecraft. The degradation produces a characteristic signal loss and change in angular response of the system which might be explained by micron sized droplets becoming a permanent residue under the influence of solar UV radiation.

Heath, D. F.↗

Photoelectrolysis of water at high current density - Use of laser light excitation of semiconductor-based photoelectrochemical cells

In the present paper, some results are given for UV laser light irradiation of the photoanode (SnO2, SrTiO3, or TiO2) in a cell for the light-driven electrolysis of H2O, at radiation intensities of up to 380 W/sq cm. The properties of the anode material are found to be independent of light intensity. Conversion of UV light to stored chemical energy in the form of 2H2/O2 from H2O was driven at a rate of up to 30 W/sq cm. High O2 evolution rates at the irradiated anodes without changes in the current-voltage curves are attributed to the excess oxidizing power associated with photogenerated holes. A test for this sort of hypothesis for H2 evolution at p-type materials is proposed.

Wrighton, M. S.↗

Simulator spectral characterization using balloon calibrated solar cells with narrow band pass filters

The development and implementation of an instrument for spectral measurement of solar simulators for testing solar cell characteristics is reported. The device was constructed for detecting changes in solar simulator behavior and for comparing simulator spectral irradiance to solar AM0 output. It consists of a standard solar cell equipped with a band pass filter narrow enough so that, when flown on a balloon to sufficient altitude along with sufficient numbers of cells, each equipped with filters of different bandpass ratings, the entire spectral response of the standard cell can be determined. Measured short circuit currents from the balloon flights thus produce cell devices which, when exposed to solar simulator light, have a current which does or does not respond as observed under actual AM0 conditions. Improvements of the filtered cells in terms of finer bandpass filter tuning and measurement of temperature coefficients are indicated.

Goodelle, G. S.↗

Radiation effects in IRAS extrinsic infrared detectors

During the calibration and testing of the Infrared Astronomy Satellite (IRAS) focal plane, it was observed that the extrinsic photoconductor detectors were affected by gamma radiation at dose levels of the order of one rad. Since the flight environment will subject the focal plane to dose levels of this order from protons in single pass through the South Atlantic Anomaly, an extensive program of radiation tests was carried out to measure the radiation effects and to devise a method to counteract these effects. The effects observed after irradiation are increased responsivity, noise, and rate of spiking of the detectors after gamma-ray doses of less than 0.1 rad. The detectors can be returned almost to pre-irradiation performance by increasing the detector bias to breakdown and allowing a large current to flow for several minutes. No adverse effects on the detectors have been observed from this bias boost, and this technique will be used for IRAS with frequent calibration to ensure the accuracy of observations made with the instrument.

Varnell, L.↗

Laser supported detonation wave source of atomic oxygen for aerospace material testing

A pulsed high-flux source of nearly monoenergetic atomic oxygen was developed to perform accelerated erosion testing of spacecraft materials in a simulated low-earth orbit (LEO) environment. Molecular oxygen is introduced into an evacuated conical expansion nozzle at several atmospheres pressure through a pulsed molecular beam valve. A laser-induced breakdown is generated in the nozzle throat by a pulsed CO2 TEA laser. The resulting plasma is heated by the ensuing laser-supported detonation wave, and then it rapidly expands and cools. An atomic oxygen beam is generated with fluxes above 10 to the 18th atoms per pulse at 8 + or - 1.6 km/s with an ion content below 1 percent for LEO testing. Materials testing yielded the same surface oxygen enrichment in polyethylene samples as observed on the STS mission, and scanning electron micrographs of the irradiated polymer surfaces showed an erosion morphology similar to that obtained on low earth orbit.

Krech, Robert H.↗

Single Event Effects Test Results for the Actel ProASIC Plus and Altera Stratix-II Field Programmable Gate Arrays

This work describes radiation testing of Actel's ProASIC Plus and Altera's Stratix-II FPGAs. The Actel Device Under Test (DUT) was a ProASIC Plus APA300-PQ208 nonvolatile, field reprogrammable device which is based on a 0.22micron flash-based LVCMOS technology. Limited investigation has taken place into flash based FPGA technologies, therefore this test served as a preliminary reference point for various SEE behaviors. The Altera DUT was a Stratix-II EP2S60F1020C4. Single Event Upset (SEU) and Single Event Latchup (SEL) were the focus of these studies. For the Actel, a latchup test was done at an effective LET of 75.0 MeV-sq cm/mg at room temperature, and no latchup was detected when irradiated to a total fluence of 1 x 10(exp 7) particles/sq cm. The Altera part was shown to latchup at room temperature.

heavy ions↗

OMH3075 Hall Effect Sensor Total Ionizing Dose Test Report

The purpose of this test was to characterize the OMH3075 Hall Effects sensor degradation for total dose response. The device samples were exposed to low dose irradiations using gamma radiation. Device parameters such as magnetic operating points, leakage currents, supply currents, and rise and fall times were investigated.

Forney, James↗