Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser absorption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Apparatus for extraction and separation of a preferentially photo-dissociated molecular isotope into positive and negative ions by means of an electric field

Molecules of one and the same isotope were preferentially photodissociated by a laser and an ultraviolet source, or by multiphoton absorption of laser radiation. The resultant ions were confined with a magnetic field, moved in opposite directions by an electric field, extracted from the photodissociation region by means of screening and accelerating grids, and collected in ducts.

Wilhelm, H. E.↗

Room-Temperature Operation of Index-Coupled Distributed-Feedback 4.75 Micron Quantum Cascade Lasers Fabricated Without Epitaxial Regrowth

The Mars Science Laboratory (MSL) was spin-stabilized during its cruise to Mars. We discuss the effects of spin on the radiometric data and how the orbit determination team dealt with them. Additionally, we will discuss the unplanned benefits of detailed spin modeling including attitude estimation and spacecraft clock correlation.

quantum cascade lasers↗

Effect of CO{sub 2}-laser power density on the absorption coefficient of polycrystalline CVD diamonds

The effect of 1-s irradiation of an uncooled polycrystalline CVD diamond plate by a focused cw CO{sub 2} laser beam with a power density of 300 – 800 kW cm{sup −2} is investigated. The absorption coefficient of the sample at a power density of 800 kW cm{sup −2} is found to be 0.035 cm{sup −1} larger as compared with that at 300 kW cm{sup −2}, which is related to the temperature dependence of its phonon-induced absorption with a change in temperature from 44 to 100 °C. It is shown that polycrystalline diamond, in contrast to other optical materials, does not exhibit nonlinear (avalanche-like) rise in absorption at high CO{sub 2}-laser power densities, at least up to 800 kW cm{sup −2}. (paper)

36 MATERIALS SCIENCE↗

Absorption spectrum of the laser-populated 3D metastable levels in barium

This paper deals with the details of the absorption spectrum of the 3D metastable term in barium. The 3D term was selectively populated with a tuneable dye laser. The fundamental triplet series (6s5d 3D-6snf 3F) is identified and extended out to n = 32. In addition, the absolute photoionization cross section was measured at 303 nm. The relative cross section from 303 to 250 nm was also measured with the absolute scale set by the measurement at 303 nm and was found to be nearly constant in the wavelength region measured.

Carlsten, J. L.↗

A two-dimensional model of the hydrogen plasma for a laser powered rocket

A two-dimensional, closed-form model originally developed by Batteh and Keefer (1974) is modified and applied to the absorption of laser radiation by a hydrogen plasma. The model is used to predict the power absorbed by plasmas at one- and ten-atmosphere pressure as a function of laser beam radius. Predicted isotherms are given for one- and ten-atmosphere plasmas, together with thermal loading of the absorption chamber wall. The model is also used in predicting the laser power required to sustain a hydrogen plasma as a function of the absorption coefficient.

Keefer, D.↗

Sensor for Monitoring Nanodevice-Fabrication Plasmas

The term plasma process diagnostics (PPD) refers to a spectroscopic technique and sensing hardware that have been proposed for monitoring plasma processes used to fabricate electronic devices that feature sizes as small as several nanometers. Nanometer dimensions are characteristic of the quantum level of miniaturization, where single impurity atoms or molecules can drastically change the local properties of the nanostructures. Such changes may be purposely used in nanoscale design but may also be extremely damaging or cause improper operation of the fabricated devices. Determination of temperature and densities of reactants near the developing features is important, since the structural synthesis is affected by characteristics of the local microenvironment. Consequently, sensors capable of nonintrusive monitoring with high sensitivity and high resolution are essential for real-time atomistic control of reaction kinetics and minimizing trace contamination in plasma processes used to fabricate electronic nanodevices. Such process-monitoring sensors are required to be compact, multiparametric, and immune to the harsh environments of processing plasmas. PPD is intended to satisfy these requirements. The specific technique used to implement plasma diagnostics with a PPD sensor would be an advanced version of continuous-wave cavity-ringdown spectroscopy (CW-CRDS) capable of profiling spectral line broadenings in order to derive both Doppler and Stark components. CRDS is based on measurements of the rate of absorption of laser light in an optical resonator. The ultimate sensitivity results from a very long absorption path length within the cavity and immunity to variations in incident laser intensity. The proposed version of this technique would involve the use of multiplexing tunable laser diodes and an actively modulated high-reflectivity optical resonator, thus offering a synergistic combination of simplicity, compactness, high sensitivity, and high resolution. The multiplexing capabilities of diode lasers could be utilized to make the PPD sensor a single, simple, compact, and inexpensive tool for the acquisition of multiparametric data. A PPD sensor would be capable of continuous measurement of such physical parameters as gas temperature, gas velocity, electron number density, and absolute densities of reacting chemical species. A laser beam can be easily adjusted to analyze the immediate vicinity of the growing nanostructures (or features etched down) in real time. The absorption enhancement in an optical cavity would afford the sensitivity needed for measurement of the temperature and densities of species at concentrations significantly lower than measurable by other nonintrusive techniques. It is anticipated that fully developed PPD sensors would enable simultaneous measurement of local temperature and determination of plasma species responsible for the synthesis and functionalization of nanodevices. These sensors would also enable tracking the pathways and origins of damaging contaminants, thereby providing feedback for adjustment of processes to optimize them and reduce contamination. The PPD sensors should also be useful for optimization of conventional microelectronics manufacturing plasma processes. Going beyond plasma processes for fabrication of electronic devices, PPD sensors could be used for monitoring of atoms, molecules, ions, radicals, clusters, and particles in a variety of other settings, including outer space. Because of their high sensitivity, such sensors could also prove useful for detecting traces of illegal drugs and explosives.

Bolshakov, Alexander↗

Excitation/Detection Strategies for OH Planar Laser-Induced Fluorescence Measurements in the Presence of Interfering Fuel Signal and Absorption Effects

Planar laser-induced fluorescence (PLIF) excitation/detection methods have been applied to obtain spatial distributions of the hydroxyl [OH] reacting intermediary and hydrocarbon [HC] primary species in laminar and turbulent combustion reactions. In this report, broadband and narrowband excitation/filtering techniques are explored to identify an optimal experimental configuration yielding significant fluorescent signal with low absorption losses. The combustion environments analyzed include 1) a laminar non-premixed methane/air flame and 2) a turbulent, non-premixed Jet-A/air fueled flame within a lean flame tube combustor. Hydrocarbon-based fuel and OH were excited via the R1 (1), R1(10) and R2(7) transitions of the A(sup 2)Epsilon(+) X(sup 2)pi(1,0) band using a broadband Nd:YAG pumped optical parametric oscillator (OPO) and narrowband Nd:YAG/dye laser with ultraviolet frequency extension (UVX) package. Variables tested for influence on fluorescent signal and absorption characteristics were excitation line, laser energy, exciting linewidth, combustion reactants, and test flow conditions. Results are intended to guide the transition from a dye/UVX laser to an OPO system for performing advanced diagnostics of low-emission combustion concepts.

Heath, Christopher M.↗

Tunable diode laser heterodyne radiometer measurement of atmospheric absorption of solar radiation

A tunable infrared heterodyne radiometer (TIHR) which uses a diode laser as the local oscillator is described as well as methods for the evaluation of the excess noise characteristics of the tunable diode laser. Preliminary atmospheric absorption data taken with the TIHR are presented and show the capability of the TIHR for making the highest resolution atmospheric measurements to date.

Harward, C. N.↗

Laser optogalvanic spectroscopy of molecules

In laser optogalvanic (LOG) spectroscopy, a tunable laser is used to probe the spectral characteristics of atomic or molecular species within an electrical discharge in a low pressure gas. Optogalvanic signals arise when the impedance of the discharge changes in response to the absorption of laser radiation. The technique may, therefore, be referred to as impedance spectroscopy. This change in impedance may be monitored as a change in the voltage across the discharge tube. LOG spectra are recorded by scanning the wavelength of a chopped CW dye laser while monitoring the discharge voltage with a lock-in amplifier. LOG signals are obtained if the laser wavelength matches a transition in a species present in the discharge (or flame), and if the absorption of energy in the laser beam alters the impedance of the discharge. Infrared LOG spectroscopy of molecules has been demonstrated and may prove to be the most productive application in the field of optogalvanic techniques.

Webster, C. R.↗

Diode Laser Sensors for Arc-Jet Characterization

The development and application of tunable diode laser (TDL) absorption sensors to monitor the health and operating conditions in the large-scale 60 MW arc-heated- plasma wind-tunnel at NASA Ames Research Center is reported. The interactive heating facility (THF) produces re-entry flow conditions by expanding the gas heated in a constricted plasma arc-heater to flow at high velocity over a model located in a test cabin. This facility provides the conditions needed to test thermal protective systems for spacecraft re-entering the earth s atmosphere. TDL sensors are developed to monitor gas flows in both the high-temperature constricted flow and the supersonic expansion flow into test cabin. These sensors utilize wavelength-tuned diode lasers to measure absorption transitions of atomic oxygen near 777.2 nm, atomic nitrogen near 856.8 nm, and atomic copper near 793.3 nm. The oxygen and nitrogen sensors measure the population density in exited electronic states of these atoms. The measurements combined with the assumption of local thermal and chemical equilibrium yield gas temperature (typically near 7,000K). The nitrogen and oxygen population temperatures are redundant, and their close agreement provides an important test of the local thermal equilibrium assumption. These temperature sensors provide time-resolved monitors of the operating conditions of the arc-heater and can be used to verify and control the test conditions. An additional TDL sensor was developed to monitor the copper concentration in the arc-heater flow yielding values as high as 13 ppm. Measurements of copper in the flow can identify flow conditions with unacceptably rapid electrode erosion, and hence this sensor provides valuable information needed to schedule maintenance to avoid costly arc-heater failure. TDL sensors were also developed for measurements in the test cabin, where absorption measurements of the populations of argon and molecular nitrogen in excited metastable electronic states established that the number density of these excited species is much lower than estimated using frozen-chemistry approximations. This key finding suggests that in the post-expansion region there is not a significant energy sequestration in electronically excited species. Finally, TDL measurements of atomic potassium seeded into the test cabin flow were used to directly measure the static temperature of the test gas. The results of this study illustrate the high potential of time-resolved TDL measurements for routine and economical sensing of arc-heater health (gas temperature and electrode erosion) as well as the time-resolved test-cabin-flow conditions in front of the model.

Hanson, Ronald K.↗

Numerical solution of strong radiation gasdynamic interactions in a hydrogen-seedant mixture

Theoretical and experimental results are provided for the absorption of laser energy by a gas flow. A two-dimensional numerical model described the temperature field, fluid dynamics, variable absorptivity and gas dynamics. The model was tested using a hydrogen-seedant mixture injected with 10.6 micron laser radiation. The laser mix was selected to allow reduced temperature gradients and energy source terms. It was found possible, by varying parameters such as the laser power and flash pressure, to precisely position the peak absorptance region in higher speed flows. More refined models are being tested to achieve accurate absorptance predictions in flows below Mach 0.0001.

Merkle, C. L.↗

An intercomparison of carbon monoxide, nitric oxide, and hydroxyl measurement techniques - Overview of results

Results from an intercomparison of methods to measure carbon monoxide (CO), nitric oxide (NO), and the hydroxyl radical (OH) are discussed. The intercomparison was conducted at Wallops Island, Virginia, in July 1983 and included a laser differential absorption and three grab sample/gas chromatograph methods for CO, a laser-induced fluorescence (LIF) and two chemiluminescence methods for NO, and two LIF methods and a radiocarbon tracer method for OH. The intercomparison was conducted as a field measurement program involving ambient measurements of CO (150-300 ppbv) and NO (10-180 pptv) from a common manifold with controlled injection of CO in incremental steps from 20 to 500 ppbv and NO in steps from 10 to 220 pptv. Only ambient measurements of OH were made. The agreement between the techniques was on the order of 14 percent for CO and 17 percent for NO. Hardware difficulties during the OH tests resulted in a data base with insufficient data and uncertanties too large to permit a meaningful intercomposition.

Hoell, J. M.↗

Program Models A Laser Beam Focused In An Aerosol Spray

Monte Carlo analysis performed on packets of light. Program for Analysis of Laser Beam Focused Within Aerosol Spray (FLSPRY) developed for theoretical analysis of propagation of laser pulse optically focused within aerosol spray. Applied for example, to analyze laser ignition arrangement in which focused laser pulse used to ignite liquid aerosol fuel spray. Scattering and absorption of laser light by individual aerosol droplets evaluated by use of electromagnetic Lorenz-Mie theory. Written in FORTRAN 77 for both UNIX-based computers and DEC VAX-series computers. VAX version of program (LEW-16051). UNIX version (LEW-16065).

Barton, J. P.↗

A Flat Analyzer Polycapillary Spectrometer for X-ray Absorption Spectroscopy of Dilute Transition Metals at X-ray-Free Electron Lasers

X-ray absorption spectroscopy (XAS) coupled with highly intense pulses from an X-ray-free electron laser (XFEL) can be used to track ultrafast chemical dynamics. Nonetheless, measurements for dilute samples (≤1 mM) have been exceptionally challenging, as scattering background signals dominate over the sample’s X-ray fluorescence. We show that femtosecond time-resolved XAS measurements of sub-millimolar transition metal solutions are now possible at the Linac Coherent Light Source (LCLS) using a high-throughput polycapillary XAS spectrometer, designed, developed, and commissioned at LCLS and the Stanford Synchrotron Radiation Lightsource (SSRL). The instrument integrates three polycapillary optics that collect and collimate X-ray fluorescence emitted from the interaction point with a high solid angle. X-ray collimated fluorescence is then selectively diffracted by coupled graphite analyzer crystals. As a result, the contribution of scattered photons is suppressed. Experiments at the Pt L 3 -edge on 0.1 mM aqueous K 2 PtCl 6 (delivered via a 100 μm liquid jet) were successfully performed in the laser pump X-ray probe configuration at the LCLS XCS and XPP instruments. We report the transient spectra of hexachloroplatinate within the first 10 ps after a 266 nm photoexcitation. We observed a short-lived reduced intermediate (≈2 ps). The polycapillary X-ray spectrometer at LCLS now enables the efficient study of the dynamics of ultradilute transition metals in solution. This capability opens the door to investigating plasmonic systems, photocatalysts, enzymes, and other scarce and dilute samples.

LCLS↗

Single-Shot Multi-keV X-Ray Absorption Spectroscopy Using an Ultrashort Laser-Wakefield Accelerator Source

We report that single-shot absorption measurements have been performed using the multi-keV x rays generated by a laser-wakefield accelerator. A 200 TW laser was used to drive a laser-wakefield accelerator in a mode which produced broadband electron beams with a maximum energy above 1 GeVand a broad divergence of ≈15 mrad FWHM. Betatron oscillations of these electrons generated 1.2 ± 0.2 x 10 6 photons/eV in the 5 keV region, with a signal-to-noise ratio of approximately 300:1. This was sufficient to allow high-resolution x-ray absorption near-edge structure measurements at the K edge of a titanium sample in a single shot. We demonstrate that this source is capable of single-shot, simultaneous measurements of both the electron and ion distributions in matter heated to eV temperatures by comparison with density functional theory simulations. The unique combination of a high-flux, large bandwidth, few femtosecond duration x-ray pulse synchronized to a high-power laser will enable key advances in the study of ultrafast energetic processes such as electron-ion equilibration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Increased electron, positron, and x-ray production from high intensity laser interactions using micro-wire targets

We report increases in energetic electrons, positrons, and x-rays emitted from high-intensity laser interactions (10 18−20 W/cm 2 ) with structured silicon micro-wires on the surface of a 1 mm gold converter target using a 10 ps laser pulse. A total of four different wire configurations are tested, where the gaps (7–28 μm) between the wires and the thicknesses (3–6 μm) of the wires are varied, while the height remains constant (⁠ ~25 μm). We observe the largest enhancement in electrons, positrons, and x-rays with the sparsest wire configurations. The electron temperature (T e ≈6 MeV) remains consistent across all shots, regardless of whether wires or planar targets are used. This suggests that the observed enhancement is due to increased laser light absorption by the accelerated electrons over a long scale length. Two-dimensional particle-in-cell simulations confirm that absorption is significantly enhanced with the wire target. Additionally, specific simulations examining laser pointing on different parts of the wire structure reveal that, while the final electron spectrum remains largely insensitive, the angular distribution is highly sensitive to these variations.

Bremsstrahlung↗

Effects of non-equilibrium ionization and excitation on radiation absorption in plasma plumes induced by ablation of metal targets with nanosecond laser pulses

Ionization and radiation absorption in nanosecond laser-induced plasma plumes are routinely modeled using the Saha–Boltzmann equilibrium ionization model (EQM). However, the equilibrium assumption can be inaccurate during the laser pulse when non-equilibrium effects significantly impact radiation absorption. In the present work, the EQM and non-equilibrium collisional-radiative model (CRM) are compared to reveal the effect of plasma non-equilibrium on radiation absorption in non-homogeneous plumes and degree of plasma shielding. Simulations of plume expansion induced by irradiation of a copper target in 1 atm argon background gas with a 10 ns Gaussian pulse at a fluence from 8 Jcm −2 to 14 Jcm −2 are performed with a hybrid computational model that couples a lumped particle direct simulation Monte Carlo method with either CRM or EQM. The simulations show that the EQM strongly underestimates the effects of ionization and radiation absorption compared to CRM and, contrary to the CRM, predict strong ionization of the background gas. The differences between the models are explained by the qualitatively different coupling between plume expansion and dynamics of ionization and exitation processes in the CRM and EQM under conditions when the characteristic times for most radiation- and electron-induced processes are longer than the pulse duration. The CRM-based predictions are also found to agree much better with available experimental data. In conclusion, these results indicate that the model of Saha–Boltzmann equilibrium cannot be used for reliable prediction of the degree of plasma shielding in plumes induced by nanosecond laser pulses or for processing results of spectroscopic measurements at early stages of expansion of such plumes.

Physics - Plasma physics↗