Search NASA⌕ Search

SEARCH · Search NASA

Results for “reference cell performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

RF Processing Experience with the GTF Prototype RF Gun

The SSRL Gun Test Facility (GTF) was built to develop a high brightness electron injector for the LCLS and has been operational since 1996. A total of five different metal cathodes (4 Cu and 1 Mg) have been installed on the GTF gun. The rf processing history with the different cathodes will be presented including peak field achieved at the cathode. The LCLS gun is intended to operate at 120 MV/m and fields up to 140 MV/m have been achieved in the GTF gun. After installing a new cathode the number of rf pulses required to reach 120 MV/m is approximately 5-10 million. Total emitted dark current and Fowler Nordheim plots are also shown over the life of the cathode. The GTF photo-injector gun is an S-band standing-wave structure, with two resonant cavities and an intervening thick washer (Figure 1). The flat, back wall of the first cavity is a copper plate that serves as photocathode when illuminated with ultraviolet light from a pulsed, high-power laser. RF power enters the gun through an iris on the outer wall of the second cavity, and is coupled to the first through the axial opening of the washer. The first cavity is often referred to as a half cell, because its full-cell length has been truncated by the cathode plate and the second cavity is called the full cell. The gun is designed to operate in a {pi} mode, with the peak field on axis in each cell approximately equal. The maximum in the half cell occurs at the cathode, and in the full cell near the center of the cavity. The field profile and tuning procedures are discussed in a separate tech note [1].

43 PARTICLE ACCELERATORS↗

Investigation of accelerated stress factors and failure/degradation mechanisms in terrestrial solar cells

Research on the reliability of terrestrial solar cells was performed to identify failure/degradation modes affecting solar cells and to relate these to basic physical, chemical, and metallurgical phenomena. Particular concerns addressed were the reliability attributes of individual single crystalline, polycrystalline, and amorphous thin film silicon cells. Results of subjecting different types of crystalline cells to the Clemson accelerated test schedule are given. Preliminary step stress results on one type of thin film amorphous silicon (a:Si) cell indicated that extraneous degradation modes were introduced above 140 C. Also described is development of measurement procedures which are applicable to the reliability testing of a:Si solar cells as well as an approach to achieving the necessary repeatability of fabricating a simulated a:Si reference cell from crystalline silicon photodiodes.

Lathrop, J. W.↗

Thin Cation-Exchange Layers Enable High-Current-Density Bipolar Membrane Electrolyzers via Improved Water Transport

With suitable water dissociation (WD) catalysts, bipolar membranes (BPMs) can efficiently dissociate water into H + and OH – at the junction between anion- and cation-exchange layers (AEL and CEL, respectively). First, however, water must be transported through the AEL or CEL and thus against the outward flow of hydrated H + and OH – . This is a challenge intrinsic to the BPM architecture and limits operation to current densities typically less than ~0.5 A·cm –2 . Here we explore how water transport affects durability and performance in reference alkaline and acidic membrane electrolyzers, and we use the insight gained to design BPMs with improved water transport. We demonstrate a thin-CEL BPM (2-μm Nafion CEL|~200 nm TiO 2 |~200 nm NiO + ionomer|50 μm Sustainion AEL) which maintains a pH difference of ~14 units between the anode and cathode for current densities of up to 3.4 A·cm –2 with a total water electrolysis voltage of ~4 V and an estimated WD overpotential of ~1.5 V. Finally, such high-current-density operation is crucial for key emerging BPM applications, including in water and carbon-dioxide electrolyzers and in (regenerative) fuel cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-T-35: A General Fill Factor Definition Serving to Characterise the MLC Misalignment Detection Capabilities of Two-Dimensional Detector Arrays

Purpose: To present a general definition of the fill factor realistically characterizing the “field coverage”, i.e. the MLC misalignment detection capabilities of a detector array. Methods: According to Gago-Arias et al.{sup 1} the fill factor of a 2D array is defined as the ratio of the area enclosed by the FWHM of the fluence response function KM(x) of a single detector and its cell area defined by the detector spacing. More generally - accounting also for the possible overlap between FWHM’s of neighboured detectors - the fill factor is here defined as that fraction of the sum of the detector cell areas in which a defined MLC misalignment is detectable when the induced percentage signal changes exceed a detection threshold d. Ideally the generalized fill factor may reach 100 %. With user code EGS-chamber and a 2 MeV photon slit beam 0.25 mm wide, both types of the fill factor were calculated for an array with total cell area 100 cm{sup 2} for chamber widths 1–9 mm, using =1mm, d=5%. Results: For single chamber width 5 mm, fill factors were 0.49 (FWHM) and 0.61 (generalized). For chamber width 2 mm the FWHM fill factor was 0.13 whereas the generalized fill factor was 0.32. For chamber widths above 7 mm, the FWHM fill factor exceeds unity, and the general fill factor is exactly 1.00. Conclusions: An updated fill factor definition is introduced which, as a generalization of the FWHM-based definition, more closely estimates the performance of small array chambers and gives a realistic value in the case of overlapping sensitive areas of neighboured chambers. References:{sup 1}A. Gago-Arias, L. Brualla-Gonzalez, D.M. Gonzalez-Castano, F. Gomez, M.S. Garcia, V.L. Vega, J.M. Sueiro, J. Pardo-Montero, “Evaluation of chamber response function influence on IMRT verification using 2D commercial detector arrays,” Phys. Med. Biol. 57, 2005–2020 (2012)

60 APPLIED LIFE SCIENCES↗

Optical Displacement Sensor (ODS), a LISA's inertial reference sensor candidate.

We propose here an optical displacement sensor (ODS) as a supplemental or backup sensor for the LISA inertial reference sensor concept. This simple ODS consists of a laser diode and a quad-cell photodiode (both commercially available). The inertial mass’ reflective surface directs the laser beam onto the quad-cell photodiode. Changes in the inertial mass’ position and orientation are then extracted from ratios of the differences and sums of the quad-cell photodiode outputs. A simpler proto-type using a 200 microns wide slit has demonstrated a resolution of 10 nm/√Hz at 1 mHz and 1 nm/√Hz above 5 mHz. The electronics noise was 1 nm/√Hz at and above 1 mHz with simple and off the shelf electronics components. Although this ODs’ current performance does not meet the LISA’s system requirement’ of 1 nm/ at 1 mHz, we think that is achievable in the near future

Abramocivi, Alex↗

Washington Clean Energy Fund: Energy Storage System Performance Test Plans and Data Requirements

This report documents the test plans, including detailed duty cycles, used in evaluating the technical performance of five energy storage systems (ESSs) sponsored by the Washington State Clean Energy Fund (CEF). These ESSs were installed at three participating utilities’ (Avista, Snohomish Public Utility District or SnoPUD, and Puget Sound Energy or PSE) designated sites. Under each test plan, a number of baseline and use case tests are defined. This report documents the test plan for each utility, including duty cycles, data and performance reporting requirements. Baseline tests defined in this report mainly focus on determining an initial or reference performance for each ESS, which may be compared with the performance at any later time to assess the state of health of the ESS. Parameter values of a given ESS obtained from baseline tests are applied for different modeling purposes and use case tests. The stored energy capacity test is the first test conducted in the baseline test program, which generates data to calculate round trip efficiency (RTE). The response time and ramp rate tests provide the time required for an ESS to change from zero to full charging/discharging rate and hence the ramp rate, which is important in understanding ESS performance for applications calling for fast response. Internal resistance testing of ESS cells is also conducted in conjunction with the response time and ramp rate tests. Finally, the baseline tests include frequency regulation (FR) and peak shaving (PS) tests based on real-world duty cycles. Upon completion of the baseline tests, use case tests are conducted at each of the storage sites with duty cycles developed to meet the site-specific criteria and conditions. The use cases are grouped according to their intended target benefits within the electric infrastructure topology (e.g., transmission versus distribution). Although an ESS may be located on the low-voltage side of a substation that provides power to a distribution feeder, a use case that addresses bulk power services could still be provided and would be grouped under the transmission or bulk-power benefits. Use cases for ESS applications deep into the distribution circuit would be categorized under the distribution system cases.

25 ENERGY STORAGE↗

Plan for resolution of technical issues at the Hanford waste treatment and immobilization plant project - 15596

The Waste Treatment and Immobilization Plant (WTP) Project has a number of first-of-a-kind technical challenges that have necessitated expert analysis and testing activities to resolve. Since 2006, the U.S. Department of Energy (DOE) chartered two major WTP technical reviews. Most recently, in 2012, a number of top scientists and engineers conducted a review focused on the design and operability of WTP black cell and hard-to-reach areas. To provide leadership and oversight for resolution of the technical issues, DOE assembled a Design Completion Team composed of personnel from the DOE Office of River Protection (ORP), DOE contractors, and the national laboratories. The Design Completion Team established five technical sub-teams to address specific focus areas. The work of these sub-teams has evolved such that the project is now focused on eight technical issues referred to as T1 to T8. The WTP contractor has developed, and DOE has approved, plans for resolution of these issues. These plans form the basis for the Pretreatment (PT) Facility engineering work that will be performed over the coming years. This work, along with a corresponding update to the PT Facility safety basis, will result in an authorization to resume the engineering work necessary to complete the PT Facility design. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A reduced basis approach for PDEs on parametrized geometries based on the shifted boundary finite element method and application to a Stokes flow

Here we propose a model order reduction technique integrating the Shifted Boundary Method (SBM) with a POD-Galerkin strategy. This approach allows to deal with complex parametrized domains in an efficient and straightforward way. The impact of the proposed approach is threefold. First, problems involving parametrizations of complex geometrical shapes and/or large domain deformations can be efficiently solved at full-order by means of the SBM. This unfitted boundary method permits to avoid remeshing and the tedious handling of cut cells by introducing an approximate surrogate boundary. Second, the computational effort is reduced by the development of a Reduced Order Model (ROM) technique based on a POD-Galerkin approach. Third, the SBM provides a smooth mapping from the true to the surrogate domain, and for this reason, the stability and performance of the reduced order basis are enhanced. This feature is the net result of the combination of the proposed ROM approach and the SBM. Similarly, the combination of the SBM with a projection-based ROM gives the great advantage of an easy and fast to implement algorithm considering geometrical parametrization with large deformations. The transformation of each geometry to a reference geometry (morphing) is in fact not required. These combined advantages will allow the solution of PDE problems more efficiently. We illustrate the performance of this approach on a number of two-dimensional Stokes flow problems.

42 ENGINEERING↗

Comparing Simulation Results from CHARM and RotCFD to the Multirotor Test Bed Experimental Data

Advanced multirotor vertical flight aircraft concepts are emerging faster than rigorous individualized tests can investigate their utility and performance. There are several analysis tools that predict multirotor performance and flow characteristics, but the accuracy of these predictions is still being debated due to lack of experimental data from multirotor tests that are needed to validate the analyses. The objective of this paper is to simulate multirotor configurations using two different mid-fidelity rotorcraft analysis tools, Comprehensive Hierarchical Aeromechanics Rotorcraft Model (CHARM) and Rotorcraft Computational Fluid Dynamics (RotCFD), and compare the simulation results to experimental data from a wind tunnel test of the Multirotor Test Bed (MTB). The MTB, developed by NASA Ames Research Center, is a new capability for testing a wide array of advanced vertical take-off and landing (VTOL) rotor configurations, with a primary focus on testing in the U.S. Army 7-by 10-Foot Wind Tunnel at NASA Ames Research Center. The MTB was designed to allow adjustment of the vertical, lateral, and longitudinal placement of up to six rotors, as well as allow tilt adjustment of each rotor and pitch adjustment of the whole assembly. The six-axis load cells under each rotor give the MTB the capability of measuring the rotor performance in a wide array of configurations. The overall goal of the MTB project is to help gain a better understanding of the performance, control, interactional aerodynamics, and acoustics of multirotor and tilting-rotor systems. For the work presented here, the MTB data were used to validate RotCFD and CHARM results for several multirotor test configurations. With confidence in both analyses established by the validation exercise, additional simulations were performed to explore quadrotor configurations that will be tested during the MTB’s second wind tunnel entry planned for 2022. This second tunnel entry will examine quadrotor configurations that represent published NASA reference designs for urban air mobility concept vehicles. Results from this paper confirm the ability of RotCFD and CHARM to simulate multirotor aerodynamic interactions on individual rotor performance under edgewise forward-flight conditions.

CHARM↗

Electrochemical Membrane for Carbon Dioxide Capture and Power Generation

FuelCell Energy, Inc. (FCE), in collaboration with AECOM Corporation (formerly URS Corporation) and Pacific Northwest National Laboratory, has been developing a novel Combined Electric Power and Carbon-dioxide Separation (CEPACS) system. The CEPACS system is based on electrochemical membrane (ECM) technology derived from FCE’s carbonate fuel cell products featuring internal (methane steam) reforming and carrying the trade name of Direct FuelCell®. The unique chemistry of carbonate fuel cells offers an innovative approach for separation of CO 2 from existing fossil-fuel power plant exhaust streams (flue gases). The ECM-based CEPACS system has the potential to become a transformational CO 2 -separation technology by working as two devices in one: it separates the CO 2 from the exhaust of other plants such as an existing coal-fired plant and simultaneously produces clean electric power at high efficiency using a supplementary fuel. The development effort was carried out under the U.S. Department of Energy (DOE) cooperative agreement DE-FE0007634. The overall objective of this project was to successfully demonstrate the ability of FCE’s ECM-based CEPACS system technology to separate ≥90% of the CO 2 from a simulated Pulverized Coal (PC) power plant flue gas stream and to compress the captured CO2 to a state that can be easily transported for sequestration or beneficial use. In addition, a key objective was to show, through the technical and economic feasibility study and bench scale testing, that the ECM-based CEPACS system is an economical alternative for CO 2 capture in PC power plants, and that it meets DOE’s objective related to the incremental cost of electricity (COE) for post-combustion CO 2 capture (no more than 35% increase in COE). The project was performed in three budget periods (BP). The specific objective for BP1 was to complete the Preliminary Technical and Economic Feasibility Study. The T&EF study was based on the carbon capture system size suitable for a reference 550 MW PC power plant. The specific objectives for BP2 were to perform (flue gas) contaminant effect evaluation tests, small area membrane tests using clean simulated flue gas, design a flue gas pretreatment system for processing of the gas feed to ECM, update the Technical & Economic Feasibility Study (T&EFS) incorporating results of contaminant effect tests and small area membrane tests, and to prepare a test facility for bench scale testing. The specific objectives for BP3 were to perform bench scale testing (parametric and long-duration testing) of a 11.7 m 2 ECM-based CO 2 capture, purification and compression system, and update (as final) the Technical and Economic Feasibility Study. In addition, an Environmental Health and Safety evaluation (assessment) of the ECM technology was included. This final technical report presents the progress made under the project.

20 FOSSIL-FUELED POWER PLANTS↗

Development of a Transferable Density-Functional Tight-Binding Model for Organic Molecules at the Water/Platinum Interface

A computationally efficient and transferable approach for modeling reactions at metal/water interfaces could significantly accelerate our understanding and ultimately the development of new catalytic transformations, particularly in the context of the emerging field of biomass conversion. Here, we present a parametrization of Pt–X (X = H, O, C) density-functional tight-binding (DFTB) for addressing this need. We first constructed Pt–H, Pt–O, and Pt–C repulsive potential splines. These pairwise parameters were then augmented to include many-body interactions using the Chebyshev Interaction Model for Efficient Simulation (ChIMES). We compare the geometrical and energetic performances of both DFTB and DFTB/ChIMES methods with DFT reference data across a variety of organic molecules at the platinum surface from nanoparticles to single-crystal surfaces. DFTB shows limited transferability between extended crystal surfaces and small nanoparticles. This transferability is significantly improved through the introduction of three-body interactions with Pt in DFTB/ChIMES, which provides consistent results across various systems, with reductions in the RMSD from around 30 kcal/mol in DFTB to around 10 kcal/mol. We demonstrate the stability and reliability of the obtained parameters by performing metadynamic simulations for the adsorption of phenol on Pt(111). We observe that DFTB itself is undersolvating the surface, leading to only one or two chemisorbed water molecules in a c(4 × 6) unit cell. In contrast, DFTB/ChIMES leads to a coverage of about 0.5 ML and successfully captures the chemisorbed mode of phenol at both the solid/liquid and the solid/gas interfaces. Furthermore, in agreement with experimental measurements, the adsorption at the solid/liquid interface is significantly weaker than that at the solid/gas interface. As a result, we highlight that even with DFTB, where we can accumulate dynamics for more than 1 ns for a given system, the simulations are not fully converged.

Adsorption↗

In Situ Reliability Investigation of All-Vanadium Redox Flow Batteries by a Stable Reference Electrode

Redox flow batteries (RFBs) have been studied over the past several decades as a promising candidate for stationary energy storage applications. It is therefore important to understand the reliability of RFBs and the mechanisms that cause degradation with time. Contributions from individual electrodes (cathode or anode) are difficult to separate especially for long-term cycle testing, due to the lack of a stable reference electrode. In our work, the reliability and degradation mechanisms of an all-vanadium RFB were investigated by a stable reference electrode based on the dynamic hydrogen electrode (DHE). With factor exploration and design optimization, the newly developed DHE reference electrode demonstrated high accuracy and long-term stability that enables in-situ monitoring of individual electrode signals (potentials and impedances) over hundreds of cycles in a vanadium RFB. This approach enables the full cell degradation to be separated and the degradation attributed to contributions from the cathode and anode. The cathode and anode were found to play quite different roles in the increase in overpotential of the vanadium RFB during long-term cycling. The anode reaction limited both the charge and discharge capacity over 100 cycles. In addition, the negative side also appeared to be the rate limiting factor throughout cycling as determined by EIS measurement. The cathode contributed to the performance degradation as cycling exceeded 50 cycles.

Huang, Qian↗

Impedances of electrochemically impregnated nickel electrodes as functions of potential, KOH concentration, and impregnation method

Impedances of fifteen electrodes form each of the four U.S. manufactures were measured at 0.200 V vs. the Hg/HgO reference electrode. This corresponds to a voltage of 1.145 for a Ni/H2 cell. Measurements were also made of a representative sample of these at 0.44 V. At the higher voltage, the impedances were small and very similar, but at the lower voltage there were major differences between manufacturers. Electrodes from the same manufacturers showed only small differences. The impedances of electrodes from two manufacturers were considerably different in 26 percent KOH from those in 31 percent KOH. These preliminary results seen to correlate with the limited data from earlier life testing of cells from these manufacturers. The impedances of cells being tested for Space Station Freedom are being followed, and more impendance measurements of electrodes are being performed as functions of manufacturer, voltage, electrolyte concentration, and cycle history in hopes of finding better correlations of impedance with life.

Reid, Margaret A.↗

Grid Convergence for Three Dimensional Benchmark Turbulent Flows

Grid convergence studies are performed to establish reference solutions for benchmark three dimensional turbulent flows in support of the ongoing turbulence model verification and validation e ort at the Turbulence Modeling Resource website curated by NASA. The bench- mark cases are a subsonic flow around a hemisphere cylinder and a transonic flow around the ONERA M6 wing with a sharp trailing edge. The study applies widely-used computational fluid dynamics codes developed and supported at the NASA Langley Research Center: FUN3D, USM3D, and CFL3D. Reference steady-state solutions are computed for the Reynolds-Averaged Navier-Stokes equations with the Spalart-Allmaras turbulence model on families of consistently-refined grids composed of different types of cells. Coarse-to- ne and code-to-code solution variation is described in detail.

Diskin, Boris↗

On the effect of scalar flux weighing of linearly anisotropic scattering matrices in few-group transport calculations

The majority of the codes available for homogenized group constant generation for deterministic transport calculations apply the approximation of scalar flux weighting during energy group condensation of higher-order anisotropic scattering matrices. In this paper, we discuss the effect of scalar flux weighting of the linearly anisotropic scattering matrices in the frame of S P{sub 3} and S{sub 12} calculations performed for a two-dimensional VVER-440 reactor benchmark. To compare group constants generated for two neutron energy groups, an infinite pin cell was homogenized with Serpent 2 and ERANOS ECCO. Serpent 2 applies scalar flux, while ERANOS ECCO performs current weighting of the linearly anisotropic scattering matrices during energy group condensation. For analyzing the effect of the various weighting options, three simple reactor models were built assuming different core sizes using standard rectangular assemblies with 15*15 fuel pins. Diffusion, SP{sub 3} and S{sub 12} calculations were performed for the 3 models using group constants generated with Serpent 2 and ERANOS ECCO. The effect of scalar flux weighting of linearly anisotropic scattering matrices is shown by comparing the decrease in reactivity due to the decreased reactor size, as well as the assembly power distribution to reference results obtained with Serpent 2 Monte Carlo calculations. Neglecting higher than linearly anisotropic scattering and indirect application of diffusion coefficients in higher-order transport calculations is advised if angular flux-moment spectra weighted higher-order scattering matrices cannot be generated. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Prospective Study of Hippocampal-Sparing Prophylactic Cranial Irradiation in Limited-Stage Small Cell Lung Cancer

Purpose: To prospectively evaluate cognitive function and intracranial failure patterns after hippocampal-sparing prophylactic cranial irradiation (PCI) for limited-stage small cell lung cancer (SCLC). Methods and Materials: Adults with limited-stage SCLC, achieving a complete response to chemoradiotherapy and no brain metastases, were eligible. Patients received PCI 25 Gy/10 fractions, with a mean hippocampal dose limited to <8 Gy and ≥90% of the brain receiving 90% of the prescription. A diverse battery of neuropsychological testing was performed at baseline and 6 and 12 months after PCI. Brain MRI scans were performed at baseline and 6, 12, 18, and 24 months. The primary endpoint was memory measured by the Hopkins Verbal Learning Test-Revised Delayed Recall at 6 months after PCI. The 25-Gy arm of Radiation Therapy Oncology Group protocol 0212 was used as a reference of potential efficacy. Development of intracranial metastases was recorded. Overall survival and progression-free survival were estimated using the Kaplan-Meier method. Results: Eight men and 12 women with a median age of 61 years enrolled. Two-year overall survival was 88% (95% confidence interval 68%-100%). There was no significant decline in performance between baseline and 6 or 12 months for any of the tests. The association between baseline intelligence quotient and change in performance on testing was not significant. Magnetic resonance imaging revealed asymptomatic brain metastases at a cumulative rate of 20%, with no concurrent extracranial progression. Two patients developed a metastasis in the under-dosed region. Neither involved the dentate gyrus, but 1 involved the avoidance region. Both patients concurrently developed additional metastasis in fully treated brain regions. There were 2 neurologic deaths. Conclusions: This prospective study suggests a potential benefit of hippocampal sparing in limiting the neuropsychological sequelae of brain radiation, but with a risk of failures in the spared region. These data strongly support continued enrollment on ongoing cooperative group randomized trials. Clinical Trials registration number: (NCT01797159).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Grid resolution requirement of chemical explosive mode analysis for large eddy simulations of premixed turbulent combustion

Full Article Figures & data References Citations Metrics Reprints & Permissions Read this article Abstract The grid resolution requirement for trustworthy Chemical Explosive Mode Analysis (CEMA) in Large Eddy Simulation (LES) of premixed turbulent combustion is proposed. Explicit filtering, to emulate the effect of the LES filter, is applied to one-dimensional laminar flame and three-dimensional planar turbulent flames across a wide range of Karlovitz numbers (5 - 239). The identification of the flame front by CEMA is found relatively insensitive to the cell size (Δ), while the combustion mode identification shows more significant sensitivity. Specifically, increasing Δ falsely enhances the auto-ignition and local extinction modes and suppresses the diffusion-assisted mode. Limited dependence of the CEMA performance on the turbulent combustion regime (Karlovitz number) is observed. A simple grid size criterion for reliable CEMA mode identification in LES is proposed as Δ ≲ δ L /2; The criterion can be relaxed to Δ ≲ δ L in the laminar flame limit. Furthermore, theoretical analysis is conducted on an idealised chemistry-diffusion system. The effects of the filtering process and turbulence on the local combustion mode are demonstrated, which is consistent with the numerical observations. Further, by incorporating turbulent combustion models in CEMA, potential improvement in identifying local combustion modes can be expected.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Insight to the Duration of 120 °C Baking on the Performance of SRF Niobium Cavities

Low-temperature baking at 100 °C - 140 °C in ultra-high vacuum for several hours is the final cavity processing technique to achieve the highest accelerating gradient cavity by eliminating the high field Q-slope, typically on cavities made of high purity fine grain niobium and subjected to electropolishing. The temperature and duration of baking control the onset of the high field Q-slope and overall quality factor over the baseline measurements. The increase in quality factor is generally related to the reduction in the temperature-dependent surface resistance, which refers to BCS surface resistance due to the reduction in the electronic mean free path and elimination of high field Q-slope is still being actively investigated. Here, we present the results of a series of measurements on 1.3 GHz TESLA shape single-cell cavities with successive low-temperature baking at 120 °C up to 96 hours. The rf loss related to the trapping of residual magnetic field refer to flux trapping sensitivity was measured with respect to the duration of 120 °C bake.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗