Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensitivity methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

SU-F-I-56: High-Precision Gamma-Ray Analysis of Medical Isotopes

Purpose: Advanced, time-resolved, Compton-suppressed gamma-ray spectroscopy with germanium detectors is implemented for assaying medical isotopes to study the radioactive decay process leading to a more accurate appraisal of the received dose and treatment planning. Lowell’s Array for Radiological Assay (LARA), a detector array that is comprised of six Compton-suppressed high-purity germanium detectors, is currently under development at UMass-Lowell which combines Compton-suppression and time-and-angle correlations to allow for highly efficient and highly sensitive measurements. Methods: Two isotopes produced Brookhaven Linac Isotope Producer (BLIP) were investigated. {sup 82}Sr which is the parent isotope for producing {sup 82}Rb is often used in cardiac PET. {sup 82}Sr gamma-ray spectrum is dominated by the 511keV photons from positron annihilation which prevent precise measurement of co-produced contaminant isotopes. A second project was to investigate the production of platinum isotopes. Natural platinum was bombarded with protons from 53MeV to 200MeV. The resulting spectrum was complicated due to the large number of stable platinum isotopes in the target, the variety of open reaction channels (p,xn), (p,pxn), (p,axn). Results: By using face-to-face NaI(Tl) counters 90-degrees to the Compton-suppressed germaniums to detect the 511keV photons, a much cleaner and more sensitive measurement of {sup 85}Sr and other contaminants was obtained. For the platinum target, we identified the production of {sup 188–189–191–195}Pt, {sup 191–192–193–194–195–196}Au and {sup 186–188–189–190–192–194–189–190–192–194}Ir. For example, at the lower energies (53 and 65MeV), we measured {sup 191}Pt production cross-sections of 144mb and 157mb. Considerable care was needed in following the process of dissolving and diluting the samples to get consistent results. The new LARA array will help us better ascertain the absolute efficiency of the counting system and more reliable production cross-sections. Conclusion: Modern HPGe spectroscopic techniques provide enhanced sensitivity, promising precise quantification of the quality of radioisotopes used in medical physics. Using new decay information may have non-trivial impact on treatment planning and dose-assessment.

07 ISOTOPE AND RADIATION SOURCES↗

Surface analysis insight note: Synthetic line shapes, integration regions and relative sensitivity factors

Here, methods for estimating photoemission intensity from X-ray photoelectron spectroscopy data are examined. The role played by “synthetic” bell-shaped curves, integration intervals, background curves, and the use of relative sensitivity factors (RSFs) in reporting percentage atomic concentration for a sample is presented. In particular, photoemission lines with differing energy distributions obtained from the NaCl sample surface are used to demonstrate how a comparison of photoemission intensities is dependent on the line shapes, background curves, and appropriate use of RSFs.

42 ENGINEERING↗

SU-E-J-08: Comparison of Unintended Radiation Doses to Organs at Risk Resulting From the Out-Of-Field Therapeutic Beams and From Image-Guidance X-Ray Procedures

Purpose: The unintended radiation dose to organs at risk (OAR) can be contributed from imaging guidance procedures as well as from leakage and scatter of therapeutic beams. This study compares the imaging dose with the unintended out-of-field therapeutic dose to patient sensitive organs. Methods: The Monte Carlo EGSnrc user codes, BEAMnrc and DOSXYZnrc, were used to simulate kV X-ray sources from imaging devices as well as the therapeutic IMRT/VMAT beams and to calculate doses to target and OARs on patient treatment planning CT images. The accuracy of the Monte Carlo simulations was benchmarked against measurements in phantoms. The dose-volume histogram was utilized in analyzing the patient organ doses. Results: The dose resulting from Standard Head kV-CBCT scans to bone and soft tissues ranges from 0.7 to 1.1 cGy and from 0.03 to 0.3 cGy, respectively. The dose resulting from Thorax scans on the chest to bone and soft tissues ranges from 1.1 to 1.8 cGy and from 0.3 to 0.6 cGy, respectively. The dose resulting from Pelvis scans on the abdomen to bone and soft tissues range from 3.2 to 4.2 cGy and from 1.2 to 2.2 cGy, respectively. The out-of-field doses to OAR are sensitive to the distance between the treated target and the OAR. For a typical Head-and-Neck IMRT/VMAT treatment the out-of-field doses to eyes are 1–3% of the target dose, or 2–6 cGy per fraction. Conclusion: The imaging doses to OAR are predictable based on the imaging protocols used when OARs are within the imaged volume and can be estimated and accounted for by using tabulated values. The unintended out-of-field doses are proportional to the target dose, strongly depend on the distance between the treated target and OAR, and are generally higher comparing to the imaging dose. This work was partially supported by Varian research grant VUMC40590.

60 APPLIED LIFE SCIENCES↗

Meta-uncertainty for particle image velocimetry

Uncertainty quantification for Particle Image Velocimetry (PIV) is critical for comparing experimentally measured flow fields with Computational Fluid Dynamics (CFD) results, and model design and validation. However, PIV features a complex measurement chain with coupled, non-linear error sources, and quantifying the uncertainty is challenging. Multiple assessments show that none of the current methods can reliably measure the actual uncertainty across a wide range of experiments, and estimates can vary. Because the current methods differ in assumptions regarding the measurement process and calculation procedures, it is not clear which method is best to use for an experiment where the error distribution is unknown. To address this issue, we propose a method to estimate an uncertainty method's sensitivity and reliability, termed the Meta-Uncertainty. The novel approach is automated, local, and instantaneous, and based on perturbation of the recorded particle images. We developed an image perturbation scheme based on adding random unmatched particles to the interrogation window pair considering the signal-to-noise (SNR) of the correlation plane. Each uncertainty scheme's response to several trials of random particle addition is used to estimate a reliability metric, defined as the rate of change of the inter-quartile range (IQR) of the uncertainties with increasing levels of particle addition. We also propose applying the meta-uncertainty as a weighting metric to combine uncertainty estimates from individual schemes, based on ideas from the consensus forecasting literature. We use planar and stereo PIV measurements across a range of canonical flows to assess the performance of the uncertainty schemes. Further, a novel method is introduced to assess an uncertainty scheme's performance based on a quantile comparison of the error and uncertainty distributions, generalizing the current method of comparing the RMS of the two distributions. Here, the results show that the combined uncertainty method outperforms the individual methods, and this work establishes the meta-uncertainty as a useful reliability assessment tool for PIV uncertainty quantification.

47 OTHER INSTRUMENTATION↗

Gravitational lens modeling with basis sets

We present a strong lensing modeling technique based on versatile basis sets for the lens and source planes. Our method uses high performance Monte Carlo algorithms, allows for an adaptive build up of complexity, and bridges the gap between parametric and pixel based reconstruction methods. We apply our method to a Hubble Space Telescope image of the strong lens system RX J1131-1231 and show that our method finds a reliable solution and is able to detect substructure in the lens and source planes simultaneously. Using mock data, we show that our method is sensitive to sub-clumps with masses four orders of magnitude smaller than the main lens, which corresponds to about 10{sup 8}M{sub ⊙}, without prior knowledge of the position and mass of the sub-clump. The modeling approach is flexible and maximizes automation to facilitate the analysis of the large number of strong lensing systems expected in upcoming wide field surveys. The resulting search for dark sub-clumps in these systems, without mass-to-light priors, offers promise for probing physics beyond the standard model in the dark matter sector.

79 ASTRONOMY AND ASTROPHYSICS↗

Determination of the Newtonian Gravitational Constant Using Atom Interferometry

We present a new measurement of the Newtonian gravitational constant G based on cold-atom interferometry. Freely falling samples of laser-cooled rubidium atoms are used in a gravity gradiometer to probe the field generated by nearby source masses. In addition to its potential sensitivity, this method is intriguing as gravity is explored by a quantum system. We report a value of G=6.667x10{sup -11} m{sup 3} kg{sup -1} s{sup -2}, estimating a statistical uncertainty of {+-}0.011x10{sup -11} m{sup 3} kg{sup -1} s{sup -2} and a systematic uncertainty of {+-}0.003x10{sup -11} m{sup 3} kg{sup -1} s{sup -2}. The long-term stability of the instrument and the signal-to-noise ratio demonstrated here open interesting perspectives for pushing the measurement accuracy below the 100 ppm level.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Challenges and Lessons Learned in Applying Sensitivity Analysis to Building Stock Energy Models

Uncertainty Analysis (UA) and Sensitivity Analysis (SA) offer essential tools to determine the limits of inference of a model and explore the factors which have the most effect on the model outputs. However, despite a well established body of work applying UA and SA to models of individual buildings, a review of the literature relating to energy models for larger groups of buildings undertaken by Fennell et al. (2019) highlighted very limited application at larger scales. This contribution describes the efforts undertaken by a group of research teams in the context of IEA-EBC Annex 70 working with a diverse set of Building Stock Models (BSMs) to apply global sensitivity analysis methods and compare their results. Since BSMs are a class of model defined by their output and coverage rather than their structure and inputs, they represent a diverse set of modelling approaches. Key challenges for the application of SA are identified and explored, including the influence of model form, input data types and model outputs. This study combines results from 7 different modelling teams, each using different models across a range of urban areas to explore these challenges and begin the process of developing standardised workflows for SA of BSMs.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

An experimental and computational investigation of the standard temperature-pressure correction factor for ion chambers in kilovoltage x rays

For ion chambers with cavities open to the surrounding atmosphere, the response measured at a given temperature and pressure must be corrected using the standard temperature-pressure correction factor (P{sub TP}). A previous paper based solely on Monte Carlo simulations [D. J. La Russa and D. W. O. Rogers, Med. Phys. 33, 4590-4599 (2006)] pointed out the shortcomings of the P{sub TP} correction factor when used to correct the response of non-air-equivalent chambers for low-energy x-ray beams. This work presents the results of several experiments that corroborate these calculations for a number of ion chambers. Monte Carlo simulations of the experimental setup revealed additional insight into the various factors affecting the extent of the breakdown of P{sub TP}, including the effect of impurities and the sensitivity to chamber dimensions. For an unfiltered 60 kV beam, the P{sub TP}-corrected response of an NE 2571 ion chamber measured at 0.7 atm was 2.5% below the response measured at reference conditions. In general, Monte Carlo simulations of the experimental setup using EGSnrc were within 0.5% of measured values. EGSnrc-calculated values of air kerma calibration coefficients (N{sub K}) at low x-ray energies are also provided as a means of estimating the level of impurities in the chambers investigated. Calculated values of N{sub K} normalized to the value measured for a 250 kV beam were obtained for three chambers and were within 1% of experiment with one exception, the Exradin A12 in a 50 kV beam.

61 RADIATION PROTECTION AND DOSIMETRY↗

Complementary bimodal approach to monitoring of photodynamic therapy with targeted nanoconstructs: numerical simulations

We propose a new approach to monitoring photodynamic therapy (PDT) of glioblastoma with the use of targeted nanoconstructs containing a photosensitiser (PS) [benzoporphyrin derivative (BPD)] and IRDye800 dye, antibodies for efficient accumulation of the drug in a tumour, and a chemotherapeutic agent for combined effect on tumour cells. Application of IRDye800 is determined by the shift of its absorption and fluorescence spectra to the near-IR range with respect to BPD that ensures a higher imaging depth. Monitoring of PDT is based on the simultaneous fluorescence and optoacoustic (OA) imaging. Fluorescence imaging provides visualisation of fluorescence agents with high molecular sensitivity and monitoring of the effectiveness of PDT by PS photobleaching. OA allows one to examine the vascular pattern of the tumour environment, as well as assess the depth of the tumour. IRDye800 is a better contrast agent in comparison to BPD due to red-shifted spectral characteristics and a higher fluorescence quantum yield. Monte Carlo simulations combined for OA simulations with K-wave modelling allowed the feasibility of the complementary approach to be studied and demonstrated that this combination allows one to localise a tumour with a size of 2 mm at depths from 100 μm to 2 mm. (paper)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-334: Dosimetric Impacts of Organ at Risk (OAR) Contour Errors in Prostate Volumetric Modulated Arc Therapy (VMAT) Planning: A Sensitivity Study

Purpose: To investigate the dosimetric impacts of OAR contour errors in prostate VMAT planning with a sensitivity analysis method. Methods: Ten randomly selected prostate VMAT patients were used to simulate OAR contour error in rectum and bladder. For each OAR 12 even spaced contour control points were selected in every three slices. For each simulation, only one of the control points was simulated to move inwards or outwards by up to 6 voxels and coordinates of adjacent voxels to that moving control point were moved accordingly with a 3D-spline smooth function. An in-house software was used to predict OARs dosimetric endpoints based on geometric relationship between PTV and OAR. In this study, the V75, V70, V65, V60 of rectum and V80, V75, V70, V65 of bladder with and without perturbed contours were calculated and compared. Results: The percentage of OAR dose volume difference around the reference OAR contours were plotted as iso-error lines overlaid on CT images. The significant difference was shown in OAR contours adjacent to the PTV where high dose gradient exists. When one of the 12 points adjacent to the PTV moved up to 6 voxels, maximum errors of 1.99%, 2.46%, 2.89%, and 3.19% were found in V75, V70, V65, and V60 of the rectum, and 1.59%, 1.67%, 1.87%, and 1.90% were found in V80, V75, V70, and V65 of the bladder, respectively. Conclusion: We can quantify the dosimetric impact of OAR contouring error by evaluating the percentage of OAR dose volume changes in prostate VMAT planning. For the adaptive radiation therapy, the iso-error lines can provide the planner a guideline that which portion of contour needed to be checked carefully because dosimetric sensitivity of contour errors are different for different part of contours.

60 APPLIED LIFE SCIENCES↗

Sensitivity Analysis of Material Model Parameters to Reproduce Crushing of Composite Tubes

The ability to predict the behavior of composite structures under impact conditions is an important challenge for engineering analysis since it requires modeling beyond the elasticity and into failure initiation and propagation. Crushing of laminate composites is the result of a combination of several and complex failure mechanisms, which are not always possible to reproduce together in a single finite element analysis (FEA). In this paper, models based on lamina-level failure criteria have been used to predict the onset of damage; once failure initiates, the mechanisms of failure propagation require reducing the material properties using several degradation schemes. Among the composite material models available in LS-DYNA, MAT-ENHANCED-COMPOSITE-DAMAGE (MAT-54) has been chosen for modeling the axial crushing of composite tubes with various resistant sections and wall slope, given the reduced experimental input parameters to insert into the card definition. Comparison with experimental data shows that such material model is able to successfully reproduce the crushing behavior, even if the numerical results are strictly correlated with some model parameters which cannot be measured experimentally or are purely mathematical expedients. Therefore, extensive calibration of these parameters by trial-and-error is necessary to achieve successful simulation results. Once done it for a structure made of the same composite material, it is possible to adopt the same card configuration for all the other cases, obtaining good agreement between numerical and experimental results. After, the attempt to model the same geometries using the MAT-LAMINATED-COMPOSITE-FABRIC (MAT-58) card with the same parameter values previously calibrated has been done obtaining results comparable with the experimental data.

36 MATERIALS SCIENCE↗

Physiological Controls on Carbon Fluxes and Biomass Production in Miscanthus: Insights From a Process‐Based Agroecosystem Model

Biomass crops serve as essential feedstocks for renewable energy and bioproducts and play a critical role in achieving lower emissions in the transportation sector. However, dedicated perennial biomass crops such as Miscanthus × giganteus (Miscanthus) remain underrepresented in process-based agroecosystem models, limiting robust evaluation of their economic and environmental performance. In this study, we developed a data-constrained representation of the sterile triploid Miscanthus (IL clone) within the process-based model ecosys, integrating global sensitivity analysis, ensemble simulation, and parameter calibration. Planting, harvesting, and fertilization practices consistent with field management were incorporated, and phenology was constrained using PhenoCam-derived Green Chromatic Coordinate (GCC) data. Using the Morris global sensitivity analysis method, we identified 11 key physiological parameters governing plant carbon, water, and nutrient relations, particularly processes associated with CO 2 assimilation. We then conducted ensemble simulations by perturbing these parameters and calibrated the model against eddy covariance fluxes and field-measured biomass. Building on the calibrated operating state, parameter-response analyses show that different photosynthetic processes influence productivity in different ways. Protein allocation determines whether productivity increases toward a higher level, whereas electron transport capacity controls additional gains once protein allocation approaches saturation. These findings demonstrate that parameter importance depends on physiological context and on which photosynthetic processes remain limiting. Calibration and validation against observations show that ecosys can reliably reproduce carbon and water fluxes, as well as both above- and belowground biomass, with post-calibration GPP R 2 improving from 0.67 to 0.95 during the calibration period and remaining high during validation (R 2 = 0.95). These results provide a mechanistic foundation for regional simulations and sustainable bioenergy assessments.

ecosys↗

Comparing the shock sensitivity of insensitive energetic materials

We present a tabletop method to study the shock sensitivity of plastic-bonded explosives that are considered shock insensitive using high dynamic range optical emission spectroscopy with laser-launched km/s flyer plate impacts (2, 3, and 4 km/s), which measures the spectral radiance (the emission spectrum vs a calibrated intensity standard) every 0.8 ns in the nanosecond and microsecond regimes. The explosives were TATB (1,3,5 trinitro, 2,4,6 triamino benzene), FOX-7 (1,1-diamino-2,2-dinitroethylene), LLM-105 (2,6-diamino-3,5-dinitropyrazine-1-oxide), and NTO (nitrotriazolone), all with 20% Sylgard 182 binder. Time resolving emission from shocked explosives produces a unique fingerprint at each shock pressure, and the emission temporal profile can be used to understand each material's shock response and the underlying mechanisms within the framework of the well-known shock ignition and growth models. Ignition was characterized by the emission intensity during nanosecond hot spot ignition. The growth process, which occurs after the shock has unloaded, was characterized by the time derivative of microsecond emission intensity. Singular-value decomposition was used to determine a characteristic spectral radiance over the entire time range, and this radiance was fit to a graybody model to determine a characteristic temperature Tc. Even though these insensitive explosives have similar shock sensitivities, our method can clearly distinguish their shock response. FOX-7 and NTO were the most sensitive, with FOX-7 having the greatest shock ignition sensitivity, growth rate, and Tc. LLM-105 was much less sensitive than FOX-7 and NTO, and TATB consistently showed the lowest sensitivity by any measure.

Akhtar, Meysam (ORCID:0000000243897837)↗

Quantum AI Based Enhanced Detection of Dementia

Quantum computing has the potential to significantly improve the early detection of Alzheimer's Disease and Related Dementias (ADRD). Quantum-enhanced machine learning can be used to perform an early screening of Alzheimer's disease using brain imaging data based on dataset of MRI scans from both healthy individuals and those diagnosed with Alzheimer's. This study aims to demonstrate the potential of quantum transfer learning to enhance the performance of the classical deep learning model for dementia detection. Using the MRI sagittal images available in the OASIS-2 (64 demented and 72 non-demented subjects between 60 and 96 years), we show how quantum techniques can transform a suboptimal classical model into a more effective solution for dementia detection, highlighting their potential impact on advancing healthcare technology. We begin with a simple classical deep learning model with a significantly smaller number of parameters, which gives suboptimal performance on the problem. Then, we apply different configurations of quantum transfer learning based on the pre-trained weak classifier (Figure 1). We fix the weak classifier's initial convolutional layers at their fixed pre-trained parameters and replace the last set of dense layers with a dressed quantum circuit (DQN), which we train to enhance performance. We performed 4-fold cross-validation for both the classical and the hybrid quantum models and trained them using Pennylane's `default.qubit' simulator and IonQ's Aria-1 simulator (noisy simulation). We showed that with significantly fewer parameters, the quantum transfer learning-based hybrid models showed significant performance enhancement over the base weak classical deep learning model for dementia detection. To classify between a demented and non-demented subject, the accuracy of quantum-based AI methods improved by 6 to 14% compared to classical methods. The sensitivity of the models improved by 4 to 17%. This shows that there are fewer chances of misclassifying demented patients. Figure 2 compares the performance of the hybrid quantum models and their base classical model, and Table 1 summarizes the results. We illustrated that with assistance from quantum machine learning, it is possible to enhance detection for dementia based on brain images. This shows the potential for practical utility of quantum computing in ADRD research.

Bhowmik, Sounak [University of Tennessee, Knoxvill↗

Modeling and Uncertainty Quantification of Vapor Sorption and Diffusion in Heterogeneous Polymers

A high-fidelity model of kinetic and equilibrium sorption and diffusion is developed and exercised. The gas-diffusion model is coupled with a triple-sorption mechanism: Henry’s law absorption, Langmuir adsorption, and pooling or clustering of molecules at higher partial pressures. Sorption experiments are conducted and span a range of relative humidities (0-95%) and temperatures (30-60°C). Kinetic and equilibrium sorption properties and effective diffusivity are determined by minimizing the absolute difference between measured and modeled uptakes. Uncertainty quantification and sensitivity analysis methods are described and exercised herein to demonstrate the capability of this modeling approach. Water uptake in silica-filled and unfilled poly(dimethylsiloxane) networks is investigated; however, the model is versatile enough to be used with a wide range of materials and vapors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coded aperture and Compton imaging for the development of 225 Ac‐based radiopharmaceuticals

Abstract Background Targeted alpha‐particle therapy (TAT) has great promise as a cancer treatment. Arguably the most promising TAT radionuclide that has been proposed is 225 Ac. The development of 225 Ac‐based radiopharmaceuticals has been hampered due to the lack of effective means to study the daughter redistribution of these agents in small animals at the preclinical stage. Purpose The ability to directly image the daughters, namely 221 Fr and 213 Bi, via their gamma‐ray emissions would be a boon for preclinical studies. That said, conventional medical imaging modalities, including single photon emission computed tomography (SPECT) based on nonmultiplexed collimation, cannot be employed due to sensitivity limitations. Methods As an alternative, we propose the use of both coded aperture and Compton imaging with the former modality suited to the 218‐keV gamma‐ray emission of 221 Fr and the latter suited to the 440‐keV gamma‐ray emission of 213 Bi. Results This work includes coded aperture images of 221 Fr and Compton images of 213 Bi in tumor‐bearing mice injected with 225 Ac‐based radiopharmaceuticals. Conclusions These results are the first demonstration of visualizing and quantifying the 225 Ac daughters in small animals through the application of coded aperture and Compton imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Search for new physics with long-lived particles decaying to photons and missing energy in pp collisions at $ \sqrt{s}=7 $ TeV

A search is performed for long-lived neutral particles decaying into a photon and invisible particles. An example of such a signature is the decay of the lightest neutralino with nonzero lifetime into a gravitino and a photon in gauge-mediated supersymmetry, with the neutralino as the next-to-lightest supersymmetric particle and the gravitino as the lightest. The search uses events containing photons, missing transverse energy, and jets. The impact parameter of the photon relative to the beam-beam collision point can be reconstructed using converted photons. The method is sensitive to lifetimes of the order of 0.1 to 1 ns. The data sample corresponds to an integrated luminosity of 2.23 inverse femtobarns in pp collisions at sqrt(s) = 7 TeV, recorded in the first part of 2011 by the CMS experiment at the LHC. Cross-section limits are presented on pair production for such particles, each of which decays into a photon and invisible particles. The observed 95% confidence level limits vary between 0.11 and 0.21 pb, depending on the neutral particle lifetime.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗