Search NASA⌕ Search

SEARCH · Search NASA

Results for “temperature monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Air-fuel micromix injector having multibank ports for adaptive cooling of high temperature combustor

A method of using a combustor for high temperature combustion. The combustor is equipped with a showerhead type micromix air-fuel injector. The injector faceplate has its ports concentrically arranged into “banks”, to which delivery of fuel can be controlled on a bank-by-bank basis. During combustor operation, the temperature of the air into the combustor is monitored. If the temperature is above a predetermined threshold, fuel is delivered to fewer than all banks of ports. As a result, the bank(s) of ports to which fuel is not delivered inject only air into the combustion chamber, and the other bank(s) of ports inject the air-fuel mixture as usual.

Coogan, Shane B.↗

Validation of temperature retrievals obtained by the Limb Infrared Monitor of the Stratosphere (LIMS) experiment on Nimbus 7

An outline is given of LIMS temperature determinations (as a function of pressure) from measurements in two channels covering portions of the 15-micrometer band of carbon dioxide. The known sources of error from the radiometer and data reduction are used to estimate the systematic and random errors expected of the results. Observational determinations of the complete end-to-end precision are obtained by computing the standard deviation of six sequential temperature retrievals in regions where the atmosphere is horizontally uniform. This yields values of 0.2 to 0.6 K, in reasonable agreement with the estimates. A correction for horizontal gradients in the atmosphere leads to a large reduction in the differences between the stratospheric temperatures determined on the ascending and descending portions of the orbit. The temperatures agree in the mean with radiosondes and rocketsondes to within 1-2 K in most regions below 1 mbar. Several interesting, previously unseen features included cold regions in the mid-latitude mesosphere and wavelike vertical variations in the tropics.

Gille, J. C.↗

X ray attenuation measurements for high-temperature materials characterization and in-situ monitoring of damage accumulation

The scope of this dissertation is to develop and apply x ray attenuation measurement systems that are capable of: (1) characterizing density variations in high-temperature materials, e.g., monolithic ceramics, ceramic and intermetallic matrix composites, and (2) noninvasively monitoring damage accumulation and failure sequences in ceramic matrix composites under room temperature tensile testing. This dissertation results in the development of: (1) a point scan digital radiography system, and (2) an in-situ x ray material testing system. Radiographic evaluation before, during, and after loading shows the effect of preexisting volume flaws on the fracture behavior of composites. Results show that x ray film radiography can monitor damage accumulation during tensile loading. Matrix cracking, fiber matrix debonding, fiber bridging, and fiber pullout are imaged throughout the tensile loading of the specimens. Further in-situ radiography is found to be a practical technique for estimating interfacial shear strength between the silicon carbide fibers and the reaction bonded silicon nitride matrix. It is concluded that pretest, in-situ, and post test x ray imaging can provide for greater understanding of ceramic matrix composite mechanical behavior.

Baaklini, George Y.↗

Monitoring Acoustically Levitated Samples

Physical behavior of sample acoustically levitated in high-temperature oven optically monitored by new system. Optical system allows visible and infrared monitoring of sample.

Glavich, T. A.↗

Non-thermal distribution of O(1D) atoms in the night-time thermosphere

The 6300 A O(1D-3P) emission has been used for many years to remotely monitor the thermospheric temperature from the Doppler width of its line profile. The O(1D) atoms in the nighttime thermosphere are initially produced by the dissociative recombination of O2(+) ions with kinetic energy much greater than the thermal energy of the ambient neutrals. The validity of the technique to monitor neutral ambient temperature by measuring O(1D) 6300 A emission depends on the degree of thermalization of the O(1D) atoms. The object of this study is to calculate the velocity distribution of the O(1D) atoms and to examine the effect of nonthermal distribution on the nighttime thermospheric neutral temperature determined.

Yee, Jeng-Hwa↗

Optical Diagnostics for High-Temperature Thermal Barrier Coatings

Thermal barrier coatings (TBCs) are typically composed of translucent ceramic oxides that provide thermal protection for metallic components exposed to high-temperature environments, such as in jet turbine engines. Taking advantage of the translucent nature of TBCs, optical diagnostics have been developed that can provide an informed assessment of TBC health that will allow mitigating action to be taken before TBC degradation threatens performance or safety. In particular, rare-earth-doped luminescent sublayers have been integrated into the TBC structure to produce luminescence that monitors TBC erosion, delamination, and temperature gradients. Erosion monitoring of TBC-coated specimens is demonstrated by utilizing visible luminescence that is excited from a sublayer that is exposed by erosion. TBC delamination monitoring is achieved in TBCs with a base rare-earth-doped luminescent sublayer by the reflectance-enhanced increase in luminescence produced in regions containing buried delamination cracks. TBC temperature monitoring is demonstrated using the temperature-dependent decay time for luminescence originating from the specific coating depth associated with a rare-earth-doped luminescent sublayer. The design and implementation of these TBCs with integrated luminescent sublayers is discussed, including co-doping strategies to produce more penetrating near-infrared luminescence. It is demonstrated that integration of the rare-earth-doped sublayers is achieved with no reduction in TBC life. In addition, results for multilayer TBCs designed to also perform as radiation barriers are also presented.

Eldridge, Jeffrey I.↗

Reannealed Fiber Bragg Gratings Demonstrated High Repeatability in Temperature Measurements

Fiber Bragg gratings (FBGs) are formed by periodic variations of the refractive index of an optical fiber. These periodic variations allow an FBG to act as an embedded optical filter, passing the majority of light propagating through a fiber while reflecting back a narrow band of the incident light. The peak reflected wavelength of the FBG is known as the Bragg wavelength. Since the period and width of the refractive index variation in the fiber determines the wavelengths that are transmitted and reflected by the grating, any force acting on the fiber that alters the physical structure of the grating will change the wavelengths that are transmitted and reflected by it. Both thermal and mechanical forces acting on the grating will alter its physical characteristics, allowing the FBG sensor to detect both the temperature variations and the physical stresses and strains placed upon it. This ability to sense multiple physical forces makes the FBG a versatile sensor. To assess the feasibility of using Bragg gratings as temperature sensors for propulsion applications, researchers at the NASA Glenn Research Center evaluated the performance of Bragg gratings at elevated temperatures for up to 300 C. For these purposes, commercially available polyimide-coated high-temperature gratings were used that were annealed by the manufacturer to 300 C. To assure the most thermally stable gratings at the operating temperatures, we reannealed the gratings to 400 C at a very slow rate for 12 to 24 hr until their reflected optical powers were stabilized. The reannealed gratings were then subjected to periodic thermal cycling from room temperature to 300 C, and their peak reflected wavelengths were monitored. The setup shown is used for reannealing and thermal cycling the FBGs. Signals from the photodetectors and the spectrum analyzer were fed into a computer equipped with LabVIEW software. The software synchronously monitored the oven/furnace temperature and the optical spectrum analyzer as well as processed the data. Experimental results presented in the following graph show typical wavelength versus temperature dependence of a reannealed FBG through six thermal cycles (80 hr). The average standard deviation of the temperature-to-wavelength relationship ranged from 1.86 to 2.92 C over the six thermal cycles each grating was subjected to. This is an error of less than 1.0 percent of full scale throughout the entire evaluation temperature range from ambient to 300 C.

Adamovsky, Grigory↗

Evaluation of EDR-3 vibration, shock, temperature, and humidity recording unit

The purpose of this evaluation was to determine if the self-contained, off-the-shelf, Environmental Data Recorder 3 (EDR-3) could be qualified to monitor shock, vibration, and temperature during rail transportation of space shuttle solid rocket components. The evaluation testing started in November 1989 and continued until June 1990. Two EDR-3 units were used to monitor both on- and off-plant shipments of shuttle components. In addition, extensive testing was performed at Thiokol's Vibration Test facility, T-53. Testing demonstrated that the EDR-3 is capable of successfully monitoring actual shipments of solid rocket hardware. Thiokol metrology has verified the accuracy of temperature monitoring. In addition, calibrated shock/vibration testing demonstrated that the EDR-3 does accurately record acceleration. It is recommended that the vendor modify the EDR-3 data recovery system to allow remote communication via a 30-foot cable. This would permit communication with the unit mounted on a case segment after a rail car cover is installed. The vendor will make this change and produce a new model, designated EDR-3-10. It is further recommended that Thiokol qualify the EDR-3-10 for transportation monitoring of redesigned solid rocket motor (RSRM) components.

Rees, Kevin G.↗

Calibration Of Oxygen Monitors

Readings corrected for temperature, pressure, and humidity of air. Program for handheld computer developed to ensure accuracy of oxygen monitors in National Transonic Facility, where liquid nitrogen stored. Calibration values, determined daily, based on entries of data on barometric pressure, temperature, and relative humidity. Output provided directly in millivolts.

Zalenski, M. A.↗

Proposed fast-response oxygen monitoring and control system for the Langley 8-foot high-temperature tunnel

A fast-response oxygen monitoring and control system, based on a Y2O3-stabilized ZrO2 sensor, was developed and tested in the laboratory. The system is capable of maintaining oxygen concentration in the CH4-O2-air combustion product gases at 20.9 + or - 1.0 percent. If the oxygen concentration in the exhaust stream differs from that in normal air by 25 percent or more, an alarm signal is provided for automatic tunnel shutdown. The overall prototype system response time was reduced from about 1 sec in the original configuration to about 0.2 sec. The basis of operation and the results of laboratory tests of the system are described.

Singh, J. J.↗

Application of an Embedded Fracture and Borehole Modeling Approach to the Understanding of EGS Collab Experiment 1

EGS Collab is a series of meso-scale experiments and associated numerical simulation activities being funded by the United States Department of Energy, Geothermal Technologies Office (GTO) to investigate enhanced geothermal system processes under in-situ stress and slightly elevated temperature conditions. This project is designed to provide scientists and engineers with immediate access to impermeable rock at scales larger than possible in the laboratory, but generally smaller than those for commercial production. Immediate access to rock is provided via the existing drifts of the former Homestake Gold Mine, now operated as the Sanford Underground Research Facility in Lead, South Dakota. The objectives of the EGS Collab project are to develop well controlled fracture networks between injector and producer boreholes using normal and shear stimulation for permeability enhancement. The first experimental site was located off the West Access drift on the 4850 Level (4850 feet below ground surface) in phyllite of the Precambrian Poorman formation, and involved the creation of a fracture network comprising a combination of hydraulic and natural fractures. A second experimental site is now being considered near the battery alcove on the 4100 Level in amphibolite and rhyolite of the Yates Unit. Data generated during these experiments will be compared against predictions of a suite of computer codes specifically designed to solve problems involving coupled thermal, hydrological, geomechanical, and geochemical processes. Comparisons between experimental and numerical simulation results will provide code developers with direction for improvements and verification of process models, build confidence in the suite of available numerical tools, and ultimately identify critical future development needs for the geothermal modeling community. Moreover, conducting thorough comparisons of models, modelling approaches, measurement approaches and measured data, via the EGS Collab project, will serve to identify techniques that are most likely to succeed at the Frontier Observatory for Research in Geothermal Energy (FORGE), the GTO’s flagship EGS research effort. Experiment 1 has comprised a series of successful tests, including a long-term chilled-water circulation test, but the testbed has two atypical EGS elements. Active ventilation in the adjacent drift over a 50-year period cooled the testbed rock mass and hydraulic fracturing intersected monitoring boreholes making them conduits for fluid flow. Numerical simulations executed in support of the design of the EGS Collab Experiment 1, computed a radial temperature distribution and stress gradient orthogonal to the drift axis, resulting in the forecast of an oblong hydraulic fracture geometry, extended in the direction of the drift from the stimulation borehole. This paper describes the numerical simulation of long-term chilled-water circulation test with an embedded fracture and borehole modeling approach. The principal objective of the simulation work is show agreement between experimental observations in terms of production fluid temperatures, monitoring borehole temperatures, injection and production pressures, and tracer recoveries using a single conceptual model for the fracture network, using characterization and monitoring data generally available for EGS. A secondary objective is to improve the numerical simulation result comparisons with additional data available from the broader monitoring equipment within the testbed versus deeper, hotter, and more remote EGS. One complicating factor for comparisons between the numerical simulation results and experimental observations, is the Joule-Thomson heating associated with large pressure drops across the fracture network.

numerical simulation, embedded fractures and boreh↗

Temperature control in wafer-level testing of large multi-segment electromigration test structures

The paper describes two methods for maintaining a constant metallization temperature throughout a wafer-level isothermal electromigration test of large multisegment test structures where Joule-heating is high and chip to chuck thermal contact is poor. In the first method, an initial calibration of Joule heating versus metal temperature is carried out. During the isothermal electromigration test, the Joule heating is continuously monitored and the chuck temperature is adjusted based on the calibration results to maintain a constant metal temperature. In the second method, temperature sensors are fabricated on the chip and then the sensors are used to monitor the chip temperature directly. The chuck temperature is then adjusted as needed.

Zamani, Nasser↗

A comparison of Nimbus 7 limb infrared monitor of the stratosphere and radiosonde temperatures in the lower stratosphere poleward of 60N

The quality of the more widely used, mapped version of the LIMS temperature data set (LAMAT) is assessed for the polar lower stratosphere by comparison with lower stratospheric radiosonde (RAOB) temperatures at a set of 22 stations. Average LIMS minus uncorrected RAOB values are within +/-0.3 K at 30, 50, and 70 hPa, and -1.2 +/-2.2 K at 100 hPa. The generally excellent LIMS/RAOB temperature comparisons at 10 to 70 hPa support the contention that there are no significant temperature bias errors in the LIMS constituent distributions for polar regions. LIMS minus RAOB differences at 100 hPa are slightly negative for the present station set, in agreement with that found by Grose et al. (1988). The month-by-month LIMS minus RAOB analysis at 100 hPa showed that LIMS is -1.9 +/-1.8 K too cold in November and December.

Remsberg, Ellis E.↗

Metal-embedded optical fibers for monitoring pressure or corrosion at high temperatures

A fiber optic sensor and a related method of manufacture are provided. The fiber optic sensor includes an embedded optical fiber contained within a metal diaphragm assembly, where the terminal end of the optical fiber is positioned opposite a diaphragm. The method includes forming a metal-embedded optical fiber by ultrasonic additive manufacturing and securing the metal-embedded optical fiber to a housing having a diaphragm that is opposite of the terminal end of the optical fiber. The sensor can provide extremely accurate pressure measurement at high temperatures and in highly corrosive media. An optical fiber-based pressure sensing system is also provided.

Petrie, Christian M.↗

Temperature and Strain Sensing Characteristics of a 128° YX-Cut LiNbO 3 Rayleigh-Mode SAW Sensor From Room to Cryogenic Temperatures

Accurate, passive, and wireless monitoring of cryogenic hardware is essential for high-energy physics, space propulsion, and biomedical instrumentation. Here, this study quantifies the coupled temperature-strain behavior of Rayleigh-mode surface acoustic-wave (SAW) delay-line sensors fabricated on 128° YX-cut LiNbO 3 . A nonlinear finite element (FE) model incorporating Varshni-based elastic constants, higher-order thermal expansion, and temperature-dependent piezo- and dielectric coefficients was developed and validated experimentally between 280K and 80K. Free-standing (first test condition) and bonded/wired (second test condition) devices exhibited indistinguishable thermal responses; the average temperature coefficient of delay (TCD) in the critical cryogenic range from 130K down to 80K differed by only 0.15 ppm/K (0.32%), confirming that bonding-induced stress is negligible. Over 280-80K the measured TCD was 61.77 ppm/K, while the FE model predicted an equivalent temperature coefficient of frequency (TCF) of −62.74 ppm/K with an overall coefficient of determination R2 = 0.998. In the critical cryogenic interval 130-80K the TCD fell to 47.66 ppm/K, indicating improved thermal stability at low temperature. Controlled loading (0-300 με) revealed a strain coefficient of delay (SCD) that rises from 0.53 ± 0.02 ppm/με at 300K to 1.05 ± 0.02 ppm/με at 80K. This modest sensitivity confirms that, for temperature sensing, strain is a second-order perturbation above 135K but must be compensated at deeper cryogenic levels. Overall, this work establishes a predictive multiphysics model together with repeatable wired measurements that confirm the suitability of SAW sensors for temperature and strain monitoring in extreme cryogenic environments, while also providing a baseline for future wireless implementations.

25 ENERGY STORAGE↗

Apparatus, methods and system for temperature gradient aging with in-situ electrical monitoring

An apparatus for making in-situ electrical measurements of a sample while the sample is subjected to a temperature gradient between a first side of the sample and a second side of the sample. The apparatus comprises a first heater and a second heater that are positioned in contact with the first side of the sample and the second side of the sample, respectively. The first heater and the second heater comprise respective faces that each have electrical contacts embedded therein. Electrical measurements pertaining to the sample can be made by way of the electrical contacts embedded in the faces. A temperature at either side of the sample can be monitored by way of thermocouples positioned inside the heaters in proximity to the faces of the heaters.

Reyes, Karla Rosa↗

A system to control CO2 in O2 concentrations in aqueous media (Year 2 Report)

Per the Statement of Work, the following tasks were outlined for completion in Year 2: 1). Testing, modification, and optimization of the system. 2). Addition of oxygen manipulation and monitoring. 3). Expansion of CO2 bubbling/pH reduction system to include oxygen addition/removal and temperature control. 4). Investigate alkalinity modification by the microbial cultures and its impact on the carbonate chemistry control of the system. 5).Deliverable: Seawater chemistry and temperature control and monitoring system for microbial culture studies under present and future ocean conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗