Search NASA⌕ Search

SEARCH · Search NASA

Results for “thermionic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

The NASA thermionic-conversion (TEC-ART) program

The current emphasis is on out-of-core thermionic conversion (TEC). The additional degrees of freedom offer new potentialities, but high-temperature material effects determine the level and lifetime of TEC performance: New electrodes not only raise power outputs but also maintain them regardless of emitter-vapor deposition on collectors. In addition, effective electrodes serve compatibly with hot-shell alloys. Space TEC withstands external and internal high-temperature vaporization problems, and terrestrial TEC tolerates hot corrosive atmospheres outside and near-vacuum inside. Finally, reduction of losses between converter electrodes is essential even though rather demanding geometries appear to be required for some modes of enhanced operation.

Morris, J. F.↗

NASA thermionic-conversion program

Technological processes in out-of-core thermionic energy conversion are described. The emphasis was on high temperature electrode materials and system engineering of converter geometries to produce practical power densities.

Morris, J. F.↗

The plasmatron as an advanced performance thermionic converter

A study concerned with the improvement of thermionic converter performance has shown that the plasma arc drop of the conventional arc (ignited) mode converter can be suppressed by use of an auxiliary ion source as in a plasmatron converter. However, this improved performance is now limited to low current densities and narrow interelectrode spacings because of voltage losses due to plasma resistance. An examination of plasmatron performance characteristics for both argon and cesium plasma has shown that the argon plasmatron is superior.

Hansen, L. K.↗

Low vapor pressure braze alloys for thermionic energy converters

Preliminary results in the use of some low-vapor-pressure braze alloys are reported; these are binary alloys of refractory metals (Th, Zr, Hf, Ru, Nb, Ir, Mo, Ta, Os, Re, W) with vapor pressures below 0.1 nanotorr at 1500 K or 10 microtorr at 2000 K. The melting point minima or eutectics of the alloys range from 1510 K to above 3000 K. Melting points and surface wetting on a Ta base are given. Results are presented on brazing of Ir, LaB6, Nb, Re, W, and ZrO2 (with 22 wt % Zr) into a Ta base or a Nb-1% Zr base. The results are applicable in electrode screening programs for thermionic cesium diodes.

Bair, V. L.↗

NASA Thermionic-Conversion program

NASA's program for applied research and technology (ART) in Thermionic Energy Conversion (TEC) has made worthwhile contributions in a relatively short time. Materials and designs previously prohibited by in-core nucleonics and geometrics now offer new potentialities. High-temperature material effects are crucial to the level and duration of TEC performance: New electrodes must increase and maintain power output regardless of emitter-vapor deposition on collectors. They must also serve compatibly with hot-shell alloys. And while space TEC must face high-temperature vaporization problems externally as well as internally, terrestrial TEC must tolerate hot corrosive atmospheres outside and near-vacuum inside. Furthermore, some modes for decreasing interelectrode losses appear to requisite rather demanding converter geometries to produce practical power densities.

Morris, J. F.↗

Thermionic converter performance with oxide collectors

Thermionic converters using a variety of metal oxide collector surfaces have been fabricated and tested. Both work function and power output data are presented and evaluated. Oxides of barium, strontium, zinc, tungsten and titanium have been incorporated into a variable spacing converter. Tungsten oxide was found to give the highest converter performance and to furnish oxygen for the emitter at the same time. Oxygenated emitters operate at reduced cesium pressure with an increase in electrode spacing. Electron spectroscopy for chemical analysis (ESCA) performed on several tungsten oxide collectors showed cesium penetration of the oxide layer, possibly forming a cesium tungstate bronze. Titanium oxide showed high performance but did not furnish oxygen for the emitter; strontium oxide, in the form of a sprayed layer, appeared to dissociate in the presence of cesium. Sprayed coatings of barium and zinc oxides produced collector work functions of about 1.3 eV, but had excessive series resistance. Lanthanum hexaboride, in combination with oxygen introduced through a silver tube, and cesium produced a low work function collector and better than average performance.

Lieb, D.↗

High-temperature, high-power-density thermionic energy conversion for space

Theoretic converter outputs and efficiencies indicate the need to consider thermionic energy conversion (TEC) with greater power densities and higher temperatures within reasonable limits for space missions. Converter-output power density, voltage, and efficiency as functions of current density were determined for 1400-to-2000 K emitters with 725-to-1000 K collectors. The results encourage utilization of TEC with hotter-than-1650 K emitters and greater-than-6W sq cm outputs to attain better efficiencies, greater voltages, and higher waste-heat-rejection temperatures for multihundred-kilowatt space-power applications. For example, 1800 K, 30 A sq cm TEC operation for NEP compared with the 1650 K, 5 A/sq cm case should allow much lower radiation weights, substantially fewer and/or smaller emitter heat pipes, significantly reduced reactor and shield-related weights, many fewer converters and associated current-collecting bus bars, less power conditioning, and lower transmission losses. Integration of these effects should yield considerably reduced NEP specific weights.

Morris, J. F.↗

Optimize out-of-core thermionic energy conversion for nuclear electric propulsion

Current designs for out of core thermionic energy conversion (TEC) to power nuclear electric propulsion (NEP) were evaluated. Approaches to improve out of core TEC are emphasized and probabilities for success are indicated. TEC gains are available with higher emitter temperatures and greater power densities. Good potentialities for accommodating external high temperature, high power density TEC with heat pipe cooled reactors exist.

Morris, J. F.↗

Diminiode thermionic energy conversion with lanthanum-hexaboride electrodes

Thermionic conversion data obtained from a variable gap cesium diminiode with a hot pressed, sintered lanthanum hexaboride emitter and an arc melted lanthanum hexaboride collector are presented. Performance curves cover a range of temperatures: emitter 1500 to 1700 K, collector 750 to 1000 K, and cesium reservoir 370 to 510 K. Calculated values of emitter and collector work functions and barrier index are also given.

Kroeger, E. W.↗

ERDA-NASA advanced thermionic technology program

Research is summarized on surface studies (work functions of different LaB6 surfaces), plasma studies, converter development (tungsten emitter, nickel collector and tungsten emitter La B6 collector), and hot shell development for using thermionic converters in the topping cycle of fossil-fuel plants.

Source record↗

Control for nuclear thermionic power source

A control for a power source which includes nuclear fuel interspersed with thermionic converters, is described. A power regulator maintains a substantially constant output voltage to a variable load, and a control circuit drives a neutron flux regulator in accordance with the current supplied to the power regulator and the neutron flux density in the region of the converters. The control circuit generates a control signal which is the difference between the neutron flux density and a linear function of the current, and drives the neutron regulator in a direction to decrease or increase the neutron flux according to the polarity of the control signal.

Sawyer, C. D.↗

Experiments with enhanced mode thermionic converters

Reduction of the ionization and scattering losses associated with ignited mode cesium diodes is essential for high thermal-to-electrical conversion efficiency. Use of an auxiliary electrode in conjunction with a noble gas in the interelectrode space should permit more efficient ion generation for space charge neutralization. The characeristics of a thermionic triode utilizing a ring electrode and a dispenser cathode emitter have been studied as a function of xenon pressure, cesium reservoir temperature, spacing, electrode temperature and pulse parameters (i.e., potential, duration and repetition rate) applied to the auxiliary electrode. Pulsed operation significantly enhanced output power with uniform discharges appearing to be sustained at emitter-collector spacings as low as 0.5 mm.

Oettinger, P. E.↗

Experimental and theoretical investigation for the suppression of the plasma arc drop in the thermionic converter

Ion generation and recombination mechanisms in the cesium plasma as they pertain to the advanced mode thermionic energy converter were studied. The decay of highly ionized cesium plasma was studied in the near afterglow to examine the recombination processes. Very low recombination in such a plasma may prove to be of considerable importance in practical converters. The approaches of external cesium generation were vibrationally excited nitrogen as an energy source of ionization of cesium ion, and microwave power as a means of resonant sustenance of the cesium plasma. Experimental data obtained so far show that all three techniques - i.e., the non-LTE high-voltage pulsing, the energy transfer from vibrationally excited diatomic gases, and the external pumping with a microwave resonant cavity - can produce plasmas with their densities significantly higher than the Richardson density. The implication of these findings as related to Lam's theory is discussed.

Shaw, D. T.↗

Diminiode thermionic energy conversion with lanthanum-hexaboride electrodes

This paper presents thermionic-conversion data obtained from a variable-gap cesium diminiode with a hot-pressed, sintered lanthanum-hexaboride emitter and an arc-melted lanthanum-hexaboride collector. Performance curves cover a range of temperatures: emitter 1500 to 1700 K, collector 750 to 1000 K, and cesium reservoir 370 to 510 K. Calculated values of emitter and collector work functions and barrier index are also given.

Kroeger, E. W.↗

Some properties of low-vapor-pressure braze alloys for thermionic converters

Density, dc electrical resistivity, thermal conductivity, and linear thermal expansion are measured for arc-melted rod-shaped samples of binary eutectics of Zr, Hf, Ru, Nb, Ir, Mo, Ta, Os, Re, and W selected as very-low-pressure braze fillers for thermionic converters. The first two properties are measured at 296 K for Zr-21.7 at% Ru, Zr-13 wt% W, Zr-19 wt% W, Zr-22.3 at% Nb, Nb-66.9 at% Ru, Hf-25.3 wt% Re, Zr-25.7 at% Ta, Hf-22.5 at% W, and Nb-35 wt% Mo. The last property is measured from 293 K to 2/3 melting point for specified alloys of different compositions. Resistivities of 0.000055 to 0.000181 ohm-cm are observed with the alloys having resistivities about ten times that of the less resistive constituent metal and about three times that of the more resistive constituent metal, except for Zr-19 wt% W and Nb-35 wt% Mo (greater resistivities). Thermal expansion coefficients vary from 0.000006 to 0.0000105/K. All brazes exhibit linear thermal expansion near that of their constituent metals.

Bair, V. L.↗

Thermionic energy converter investigations

This paper presents evaluation of a variety of thermionic converter configurations to obtain improved efficiency. A variable-spacing diode using an iridium emitter gave emission properties comparable to platinum, but the power output from a sintered LaB6 collector diode was not consistent with its work function. Reflectivities above 0.5 were measured at thermal energies on oxygenated-cesiated surfaces using a field emission retarding potential gun. Performance of converters with structured electrodes and the characteristics of a pulsed triode were studied as a function of emitter, collector, cesium reservoir, interelectrode spacing, xenon pressure, and pulsing parameters.

Goodale, D. B.↗

DOE/JPL advanced thermionic technology program

Progress made in different tasks of the advanced thermionic technology program is described. The tasks include surface and plasma investigations (surface characterization, spectroscopic plasma experiments, and converter theory); low temperature converter development (tungsten emitter, tungsten oxide collector and tungsten emitter, nickel collector); component hardware development (hot shell development); flame-fired silicon carbide converters; high temperature and advanced converter studies; postoperational diagnostics; and correlation of design interfaces.

Source record↗