Search NASA⌕ Search

SEARCH · Search NASA

Results for “tracking errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

SU-E-J-44: A Novel Approach to Quantify Patient Setup and Target Motion for Real-Time Image-Guided Radiotherapy (IGRT)

Purpose Isocenter shifts and rotations to correct patient setup errors and organ motion cannot remedy some shape changes of large targets. We are investigating new methods in quantification of target deformation for realtime IGRT of breast and chest wall cancer. Methods Ninety-five patients of breast or chest wall cancer were accrued in an IRB-approved clinical trial of IGRT using 3D surface images acquired at daily setup and beam-on time via an in-room camera. Shifts and rotations relating to the planned reference surface were determined using iterative-closest-point alignment. Local surface displacements and target deformation are measured via a ray-surface intersection and principal component analysis (PCA) of external surface, respectively. Isocenter shift, upper-abdominal displacement, and vectors of the surface projected onto the two principal components, PC1 and PC2, were evaluated for sensitivity and accuracy in detection of target deformation. Setup errors for some deformed targets were estimated by superlatively registering target volume, inner surface, or external surface in weekly CBCT or these outlines on weekly EPI. Results Setup difference according to the inner-surface, external surface, or target volume could be 1.5 cm. Video surface-guided setup agreed with EPI results to within < 0.5 cm while CBCT results were sometimes (∼20%) different from that of EPI (>0.5 cm) due to target deformation for some large breasts and some chest walls undergoing deep-breath-hold irradiation. Square root of PC1 and PC2 is very sensitive to external surface deformation and irregular breathing. Conclusion PCA of external surfaces is quick and simple way to detect target deformation in IGRT of breast and chest wall cancer. Setup corrections based on the target volume, inner surface, and external surface could be significant different. Thus, checking of target shape changes is essential for accurate image-guided patient setup and motion tracking of large deformable targets. NIH grant for the first author as cionsultant and the last author as the PI.

60 APPLIED LIFE SCIENCES↗

SU-D-BRD-05: Online Framework for Plan Tracking and Automatic Checks in Radiation Therapy

Purpose: To develop an online framework that tracks a patient’s plan from initial simulation to treatment and that helps automate elements of the physics plan checks usually performed in the record and verify (RV) system and treatment planning system. Methods: We have developed PlanTracker, an online plan tracking system that automatically imports new patients tasks and follows it through treatment planning, physics checks, therapy check, and chart rounds. A survey was designed to collect information about the amount of time spent by medical physicists in non-physics related tasks. We then assessed these non-physics tasks for automation. Using these surveys, we directed our PlanTracker software development towards the automation of intra-plan physics review. We then conducted a systematic evaluation of PlanTracker’s accuracy by generating test plans in the RV system software designed to mimic real plans, in order to test its efficacy in catching errors both real and theoretical. Results: PlanTracker has proven to be an effective improvement to the clinical workflow in a radiotherapy clinic. We present data indicating that roughly 1/3 of the physics plan check can be automated, and the workflow optimized, and show the functionality of PlanTracker. When the full system is in clinical use we will present data on improvement of time use in comparison to survey data prior to PlanTracker implementation. Conclusion: We have developed a framework for plan tracking and automatic checks in radiation therapy. We anticipate using PlanTracker as a basis for further development in clinical/research software. We hope that by eliminating the most simple and time consuming checks, medical physicists may be able to spend their time on plan quality and other physics tasks rather than in arithmetic and logic checks. We see this development as part of a broader initiative to advance the clinical/research informatics infrastructure surrounding the radiotherapy clinic. This research project has been financially supported by Varian Medical Systems, Palo Alto, CA, through a Varian MRA.

60 APPLIED LIFE SCIENCES↗

A numerical comparison of precipitating turbulent flows between large‐eddy simulation and one‐dimensional turbulence

This study presents the results of computational fluid dynamics simulations of a multiphase, reacting, turbulent mixing layer in an idealized geometry. The purpose is to compare large‐eddy simulation (LES) to one‐dimensional turbulence (ODT) and examine the trends of the flow under differing mixing conditions. Aqueous streams are mixed together to precipitate polymorphs of calcium carbonate. The polymorphs of calcium carbonate are tracked numerically using population balance equations (PBE). Each PBE contains all of the relevant physical models to track the particle evolution including nucleation, growth, and aggregation. A simple subgrid mixing model that is convenient for use with PBEs was implemented in the LES code. The higher spatial resolution achievable with ODT allowed an investigation on the effect of resolution on the mixing‐model error. The Reynolds number of the flow is varied and is shown to cause a decrease in average particle sizes with higher mixing rates. © 2015 American Institute of Chemical Engineers AIChE J , 61: 3185–3197, 2015

Abboud, Alex W.↗

SU-E-J-23: An Accurate Algorithm to Match Imperfectly Matched Images for Lung Tumor Detection Without Markers

Purpose: In order to locate lung tumors on projection images without internal markers, digitally reconstructed radiograph (DRR) is created and compared with projection images. Since lung tumors always move and their locations change on projection images while they are static on DRRs, a special DRR (background DRR) is generated based on modified anatomy from which lung tumors are removed. In addition, global discrepancies exist between DRRs and projections due to their different image originations, scattering, and noises. This adversely affects comparison accuracy. A simple but efficient comparison algorithm is reported. Methods: This method divides global images into a matrix of small tiles and similarities will be evaluated by calculating normalized cross correlation (NCC) between corresponding tiles on projections and DRRs. The tile configuration (tile locations) will be automatically optimized to keep the tumor within a single tile which has bad matching with the corresponding DRR tile. A pixel based linear transformation will be determined by linear interpolations of tile transformation results obtained during tile matching. The DRR will be transformed to the projection image level and subtracted from it. The resulting subtracted image now contains only the tumor. A DRR of the tumor is registered to the subtracted image to locate the tumor. Results: This method has been successfully applied to kV fluoro images (about 1000 images) acquired on a Vero (Brainlab) for dynamic tumor tracking on phantom studies. Radiation opaque markers are implanted and used as ground truth for tumor positions. Although, other organs and bony structures introduce strong signals superimposed on tumors at some angles, this method accurately locates tumors on every projection over 12 gantry angles. The maximum error is less than 2.6 mm while the total average error is 1.0 mm. Conclusion: This algorithm is capable of detecting tumor without markers despite strong background signals.

60 APPLIED LIFE SCIENCES↗

Interactive Effects of Climate Change and Decomposer Communities on the Stabilization of Wood-Derived Carbon Pools: Catalyst for a New Study

Globally, forest soils store ~two-thirds as much carbon (C) as the atmosphere. Although wood makes up the majority of forest biomass, the importance of wood contributions to soil C pools is unknown. Even with recent advances in the mechanistic understanding of soil processes, integrative studies tracing C input pathways and biological fluxes within and from soils are lacking. Therefore, our research objectives were to assess the impact of different fungal decay pathways (i.e., white-rot versus brown-rot)—in interaction with wood quality, soil temperature, wood location (i.e., soil surface and buried in mineral soil), and soil texture—on the transformation of woody material into soil CO 2 efflux, dissolved organic carbon (DOC), and soil C pools. The use of 13 C-depleted woody biomass harvested from the Rhinelander, WI free-air carbon dioxide enrichment (Aspen-FACE) experiment affords the unique opportunity to distinguish the wood-derived C from other soil C fluxes and pools. We established 168 treatment plots across six field sites (three sand and three loam textured soil). Treatment plots consisted of full-factorial design with the following treatments: 1. Wood chips from elevated CO 2 , elevated CO 2 + O 3 , or ambient atmosphere AspenFACE treatments; 2. Inoculated with white rot (Bjerkandera adusta) or brown rot (Gloeophyllum sepiarium) pure fungal cultures, or the original suite of endemic microbial community on the logs; and 3. Buried (15cm in soil as a proxy for coarse roots) or surface applied wood chips. We also created a warming treatment using open-topped, passive warming chambers on a subset of the above treatments. Control plots with no added wood (“no chip control”) were incorporated into the research design. Soils were sampled for initial δ 13 C values, CN concentrations, and bulk density. A subset of plots were instrumented with lysimeters for sampling soil water and temperature data loggers for measuring soil temperatures. To determine the early pathways of decomposition, we measured soil surface CO 2 efflux, dissolved organic C (DOC), and DO 13 C approximately monthly over two growing seasons from a subsample of the research plots. To determine the portion of soil surface CO 2 efflux attributable to wood-derived C, we used Keeling plot techniques to estimate the associated δ 13 C values of the soil CO 2 efflux. We measured the δ 13 CO 2 once during the peak of each growing season. Initial values for soil δ 13 C values and CN concentrations averaged across the six sites were -26.8‰ (standard error = 0.04), 2.46% (se = 0.11), and 0.15% (se = 0.01), respectively. The labeled wood chips from the Aspen FACE treatments had an average δ13C value of -39.5‰ (se 0.10). The >12 ‰ isotopic difference between the soil and wood chip δ 13 C values provides the basis for tracking the wood-derived C through the early stages of decomposition and subsequent storage in the soil. Across our six research sites, average soil surface CO 2 efflux ranged from 1.04 to 2.00 g CO 2 m -2 h -1 for the first two growing seasons. No wood chip controls had an average soil surface CO 2 efflux of 0.67 g CO 2 m -2 h -1 or about half of that of the wood chip treatment plots. Wood-derived CO 2 efflux was higher for loam textured soils relative to sands (0.70 and 0.54 g CO 2 m -2 h -1 , respectively; p = 0.045)), for surface relative to buried wood chip treatments (0.92 and 0.39 g CO 2 m -2 h -1 , respectively; p < 0.001), for warmed relative to ambient temperature treatments (0.99 and 0.78 g CO 2 m -2 h -1 , respectively; 0.004), and for natural rot relative to brown and white rots (0.93, 0.82, and 0.78 g CO 2 m -2 h -1 , respectively; p = 0.068). Our first two growing seasons of soil surface CO 2 efflux data show that wood chip location (i.e., surface vs. buried chip application) is very important, with surface chips loosing twice the wood-derived CO 2 . The DOC data support this trend for greater loss of ecosystem C from surface chips. This has strong implications for the importance of root and buried wood for ecosystem C retention. This strong chip location effect on wood-derived C loss was significantly modified by soil texture, soil temperature, decomposer communities, and wood quality as effected by potential future CO 2 and O 3 levels.

54 ENVIRONMENTAL SCIENCES↗

Automatic tracking of arbitrarily shaped implanted markers in kilovoltage projection images: A feasibility study

Purpose: Certain types of commonly used fiducial markers take on irregular shapes upon implantation in soft tissue. This poses a challenge for methods that assume a predefined shape of markers when automatically tracking such markers in kilovoltage (kV) radiographs. The authors have developed a method of automatically tracking regularly and irregularly shaped markers using kV projection images and assessed its potential for detecting intrafractional target motion during rotational treatment. Methods: Template-based matching used a normalized cross-correlation with simplex minimization. Templates were created from computed tomography (CT) images for phantom studies and from end-expiration breath-hold planning CT for patient studies. The kV images were processed using a Sobel filter to enhance marker visibility. To correct for changes in intermarker relative positions between simulation and treatment that can introduce errors in automatic matching, marker offsets in three dimensions were manually determined from an approximately orthogonal pair of kV images. Two studies in anthropomorphic phantom were carried out, one using a gold cylindrical marker representing regular shape, another using a Visicoil marker representing irregular shape. Automatic matching of templates to cone beam CT (CBCT) projection images was performed to known marker positions in phantom. In patient data, automatic matching was compared to manual matching as an approximate ground truth. Positional discrepancy between automatic and manual matching of less than 2 mm was assumed as the criterion for successful tracking. Tracking success rates were examined in kV projection images from 22 CBCT scans of four pancreas, six gastroesophageal junction, and one lung cancer patients. Each patient had at least one irregularly shaped radiopaque marker implanted in or near the tumor. In addition, automatic tracking was tested in intrafraction kV images of three lung cancer patients with irregularly shaped markers during 11 volumetric modulated arc treatments. Purpose-built software developed at our institution was used to create marker templates and track the markers embedded in kV images. Results: Phantom studies showed mean ± standard deviation measurement uncertainty of automatic registration to be 0.14 ± 0.07 mm and 0.17 ± 0.08 mm for Visicoil and gold cylindrical markers, respectively. The mean success rate of automatic tracking with CBCT projections (11 frames per second, fps) of pancreas, gastroesophageal junction, and lung cancer patients was 100%, 99.1% (range 98%–100%), and 100%, respectively. With intrafraction images (approx. 0.2 fps) of lung cancer patients, the success rate was 98.2% (range 97%–100%), and 94.3% (range 93%–97%) using templates from 1.25 mm and 2.5 mm slice spacing CT scans, respectively. Correction of intermarker relative position was found to improve the success rate in two out of eight patients analyzed. Conclusions: The proposed method can track arbitrary marker shapes in kV images using templates generated from a breath-hold CT acquired at simulation. The studies indicate its feasibility for tracking tumor motion during rotational treatment. Investigation of the causes of misregistration suggests that its rate of incidence can be reduced with higher frequency of image acquisition, templates made from smaller CT slice spacing, and correction of changes in intermarker relative positions when they occur.

60 APPLIED LIFE SCIENCES↗

Towards Realistic and High Fidelity Models for Nuclear Reactor Power Synthesis Simulation with Self-Powered Neutron Detectors

As presented in this report, a weighting function–based inferencing method is being applied to synthesize the power distribution in next-generation and university research reactors based on simulated self power neutron detector (SPND) responses. The overall goal is to assess the impacts of sensor uncertainty and true power distribution perturbations on the error in the synthesized power distribution. Regarding sensor uncertainty, the NuScale Small Modular Reactor (SMR) and the Westinghouse AP1000 serve as testbeds for analyzing the impact of varying the sensor uncertainty, as well as varying the number of sensors per sensor string in the reactor core. The reactor models are informed by Monte Carlo N-Particle (MCNP) neutron flux tallies. For the NuScale SMR and Westinghouse AP1000, the SPND response functions (i.e., the response of the SPNDs to individual segments of fuel) were determined homogeneously. Regarding an analysis of power distribution perturbation detection, the Texas A&M Testing, Research, Isotopes, General Atomics Reactor (TAMU TRIGA) reactor was used as a demonstration case with one particular arrangement of SPNDs; the response functions for this reactor model were determined heterogeneously, making this a uniquely high-fidelity demonstration of perturbation detection. Finally, SPND models generated in the Geometry and Tracking 4 (Geant4) code have been generated and tested for comparison with traditionally implemented analytical SPND models, with the intent for Geant4 integration with the full methodological framework. SPND current outputs as a function of distance from some fuel assembly segment in the NuScale SMR are compared with the analytically determined currents. Results from the sensor uncertainty simulations for the NuScale SMR and AP1000 indicate that the average error in the inferred power distribution on the fuel assembly segment level is reasonably low, being slightly less than the random uncertainty applied to all respective SPNDs in both cores. For example, if all SPNDs in the core have a random uncertainty of 5%, then the corresponding fuel assembly segment level error (i.e. difference between the true and inferred local power) is ~2–3%. However, the maximum error in the inferred power distribution on the fuel assembly segment level can be considerably high (>15%) when SPND random uncertainties start to exceed ~3%. In general, the average and maximum errors in the inferred power distribution were slightly higher in the AP1000 as opposed to the NuScale SMR for the sensor string configurations considered herein. Another result determined from analysis of the sensor uncertainty simulations was that increasing the number of SPNDs per string does not clearly reduce inferred power distribution error and can in fact make the error large in some cases; however, this assessment may skewed due to imposed iteration limits. Results from the perturbation detection demonstration using the high-fidelity TAMU TRIGA model indicate that, given the arrangement of 17 SPND strings and 4 SPNDs per string considered herein, there is a clear, provable ability to infer a localized Gaussian-type peak perturbation in the 3D power distribution. Such a perturbation was detected with an average fuel assembly segment level error of 0.19%, and the general visualization of the detected perturbation clearly indicates that the magnitude and shape were appropriately resolved. Finally, the electrical current output generated by the Geant4 modeled SPND indicates significant magnitude differences than the analytically modeled SPND, demonstrating the need for accurate SPND models which account for finite sensor geometry effects to inform the power synthesis work described herein.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Modeling sequential context effects in diagnostic interpretation of screening mammograms

Prior research has shown that physicians’ medical decisions can be influenced by sequential context, particularly in cases where successive stimuli exhibit similar characteristics when analyzing medical images. This type of systematic error is known to psychophysicists as sequential context effect as it indicates that judgments are influenced by features of and decisions about the preceding case in the sequence of examined cases, rather than being based solely on the peculiarities unique to the present case. We determine if radiologists experience some form of context bias, using screening mammography as the use case. To this end, we explore correlations between previous perceptual behavior and diagnostic decisions and current decisions. We hypothesize that a radiologist’s visual search pattern and diagnostic decisions in previous cases are predictive of the radiologist’s current diagnostic decisions. To test our hypothesis, we tasked 10 radiologists of varied experience to conduct blind reviews of 100 four-view screening mammograms. Eye-tracking data and diagnostic decisions were collected from each radiologist under conditions mimicking clinical practice. Perceptual behavior was quantified using the fractal dimension of gaze scanpath, which was computed using the Minkowski–Bouligand box-counting method. To test the effect of previous behavior and decisions, we conducted a multifactor fixed-effects ANOVA. Further, to examine the predictive value of previous perceptual behavior and decisions, we trained and evaluated a predictive model for radiologists’ current diagnostic decisions. ANOVA tests showed that previous visual behavior, characterized by fractal analysis, previous diagnostic decisions, and image characteristics of previous cases are significant predictors of current diagnostic decisions. Additionally, predictive modeling of diagnostic decisions showed an overall improvement in prediction error when the model is trained on additional information about previous perceptual behavior and diagnostic decisions.

60 APPLIED LIFE SCIENCES↗

Ultimate Bifacial Showdown: 75kW Field Results

This work presents one year results for a side-by-side comparison of 5 different bifacial technologies, deployed in a 75-kW single-axis tracked field at Golden, CO. Four PERC (multi and mono) and 1 Silicon Heterojunction manufacturers are represented. Reference strings of equivalent monofacial PV modules are also installed for a direct technology comparison and calculation of bifacial gain. Analysis indicates performance within expectation, with a cumulative model mean error within +/- 2% for both bifacial and monofacial models and cumulative bifacial energy gain between 6-9%. High accuracy string-level DC monitoring and module-level measurements are also presented, showing effects of snow and edge effects in the order of +/- 3% for non-uniform irradiance across the row. Data from a custom-module to measure shading loss from the torque-tube is installed, showing up to 6% irradiance non-uniformity for the month of January.

bifacial field validation↗

SU-G-JeP1-04: Characterization of a High-Definition Optical Patient Surface Tracking System Across Five Installations

Purpose: To assess the performance of Varian’s real-time, Optical Surface Monitoring System (OSMS) by measuring relative regular and irregular surface detection accuracy in 6 degrees of motion (6DoM), across multiple installations. Methods: Varian’s Intracranial SRS Package includes OSMS, which utilizes 3 HD camera/projector pods to map a patient surface, track intra-fraction motion, and gate the treatment beam if motion exceeds a threshold. To evaluate motion-detection accuracy of OSMS, we recorded shifts of a cube-shaped phantom on a single Varian TrueBeam linear accelerator as known displacements were performed incrementally across 6DoM. A subset of these measurements was repeated on identical OSMS installations. Phantom motion was driven using the TrueBeam treatment couch, and incremented across ±2cm in steps of 0.1mm, 1mm, and 1cm in the cardinal planes, and across ±40° in steps of 0.1°, 1°, and 5° in the rotational (couch kick) direction. Pitch and Roll were evaluated across ±2.5° in steps of 0.1° and 1°. We then repeated this procedure with a frameless SRS setup with a head phantom in a QFix Encompass mask. Results: Preliminary data show OSMS is capable of detecting regular-surfaced phantom displacement within 0.03±0.04mm in the cardinal planes, and within 0.01±0.03° rotation across all planes for multiple installations. In a frameless SRS setup, OSMS is accurate to within 0.10±0.07mm and 0.04±0.07° across 6DoM. Additionally, a reproducible “thermal drift” was observed during the first 15min of monitoring each day, and characterized by recording displacement of a stationary phantom each minute for 25min. Drift settled after 15min to an average delta of 0.26±0.03mm and 0.38±0.03mm from the initial capture in the Y and Z directions, respectively. Conclusion: For both regular surfaces and clinical SRS situations, OSMS exceeds quoted detection accuracy. To reduce error, a warm-up period should be employed to allow camera/projector pod thermal stabilization.

60 APPLIED LIFE SCIENCES↗

Procedure Parsing: A Method for Parsing Handwritten Documents into Computer-Based Procedures

The nuclear industry is heavily procedure driven, where almost everything has a step-by-step instruction that is expected to be followed in detail. Historically, these procedures were printed on paper copies. Recently, the industry transitioned towards electronic copies (i.e., PDFs on tablets). One major drive for this transition is the introduction of human error and loss of situation awareness when using paper copies. However, electronic copies of documents inherently have the same error traps as their paper cousins. Therefore, there is an increased interest in a way to utilize the information in the step-by-step guidance, but to present it in a dynamic manner that guides the user and adapts to any encountered conditions. Researchers at Idaho National Laboratory propose a flexible, automated method based on document parsing and augmented by natural language processing (NLP) techniques, to address these shortcomings and capitalize on these recent advancements in machine learning. The proposed method provides a cost-effective solution for computer-assisted procedure parsing of hand-written control room procedures, originally authored in Word or PDF formats, into instructions that can be displayed as computer-based procedures (CBP) in a modern graphical user interface. The researchers devised, implemented and demonstrated the Operating Procedure Extender for Novel Systems (OPENS) method in 2020. The key to OPENS is to map the original procedure text into a context-free grammar, tying content to equipment, locations, and other steps, actions, etc. This formal grammar is then used to isolate and define keywords and actions verbs, such as “measure” or “evaluate” and tie them to specific equipment referenced within that step or located in other steps, substeps, actions, subactions and tables throughout the procedure. OPENS generates an abstract syntax tree from the document which it uses to store a copy of this information in the open-standard, machine-readable and human-readable file formats XML and JSON. The XML is useful to preserve the relational aspects of the procedure for referencing tables and branching information so the user can be directed to the next appropriate active step based on the values entered for that step and previous steps. The JSON is useful for storing and exchanging data objects used to track responses to previous steps and state changes in simulated environments. In future iterations, these formats can also be used for storing more detailed information about input during plant operation or simulation. The techniques the researcher developed could further be improved by integration of recent advancements in machine learning. NLP methods could standardize documents, correct for grammatical error, and provide automated semantic validation. The researcher expects that self-supervised techniques applied to collections of natural language instructions could strengthen the model with broader context. All these methods together give us a practical way to automatically extract protocols from documents and user interactions, empowering researchers, procedure writers and nuclear operators while moving the industry forward.

99 GENERAL AND MISCELLANEOUS↗

Machine Learning Techniques for Data Reduction of Climate Applications

Scientists conduct large-scale simulations to compute derived quantities-of-interest (QoI) from primary data. Often, QoI are linked to specific features, regions, or time intervals, such that data can be adaptively reduced without compromising the integrity of QoI. For many spatiotemporal applications, these QoI are binary in nature and represent presence or absence of a physical phenomenon. We present a pipelined compression approach that first uses neural-network-based techniques to derive regions where QoI are highly likely to be present. Then, we employ a Guaranteed Autoencoder (GAE) to compress data with differential error bounds. GAE uses QoI information to apply low-error compression to only these regions. This results in overall high compression ratios while still achieving downstream goals of simulation or data collections. Experimental results are presented for climate data generated from the E3SM Simulation model for downstream quantities such as tropical cyclone and atmospheric river detection and tracking. These results show that our approach is superior to comparable methods in the literature.

Li, Xiao [University of Florida]↗

Data-driven Alignment of the Tracker for the Mu2e Experiment

An alignment of the Mu2e Tracker is investigated using the Mu2e Offline Software and Millepede-II. Simulated misalignments of Tracker planes were inserted between Monte-Carlo event generation and before reconstruction using randomly generated $(x,y,z)$-translations and rotations of the rigid-body planes in the detector model. Cosmic ray muons, with no magnetic field present in the Detector Solenoid, will follow a straight-line trajectory. A maximum-likelihood fit is used to reconstruct a track and determine its parameters. Tracks traversing at least four planes, with ten registered straw hits, and a maximum time residual of $20$ ns are selected to be used in an alignment sample. The cuts were chosen to discard tracks with low information content, such as those with high levels of multiple scattering or those with low numbers of measurements contributing to a single track fit. Millepede-II produces the resulting alignment constants according to a simultaneous least-squares fit of the alignment parameters and the track parameters for all input tracks. The improved alignment constants are used to repeat the process and recover an increased number of suitable tracks, further improving the estimate of the alignment constants in subsequent iterations. A performance study of the process was conducted on a misaligned Tracker in the case of translation-only, and translation plus rotational misalignments. In both cases, the correct alignment constants were recovered to within statistical error after three global fit iterations. Additionally, a continuous integration system was developed for the \texttt{Mu2e/Offline} GitHub repository, introducing a convenient automated testing process for all proposed changes (``pull requests"). The tests developed included a full build of the software, followed by tests of the validation routines, geometry overlap checking, and multi-threading mode. Additionally, code quality checks and low-statistics physics comparison checks a re also available.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Joint Channel Equalization and Symbol Detection for IoT Devices in Severe Multipath Channels

Internet of Things (IoT) devices often transmit very short message blocks without strong error correction coding or pilots for channel equalization. When the transmitted signals encounter a severe multipath channel, the receiver is often unable to equalize the resulting inter-symbol interference (ISI) via traditional methods, leading to a high retransmission rate. This paper proposes a joint channel equalization and symbol detection scheme for this scenario by utilizing the preamble sequence as a training pilot for equalization and the relatively weak cyclic redundancy check (CRC) 8-Dallas code for error correction. By assuming a sparse channel impulse response, the proposed joint channel equalization and symbol detection scheme formulates an l1 norm constrained optimization problem and solves it by a saddle-point algorithm. The proposed algorithm is applied to a set of real-world underwater animal tracking IoT data, and the results show improvement of correct message detection rate from 21:5% to 41:6%.

Jing, Shusen↗

IGRT/ART phantom with programmable independent rib cage and tumor motion

Purpose: This paper describes the design and experimental evaluation of the Methods and Advanced Equipment for Simulation and Treatment in Radiation Oncology (MAESTRO) thorax phantom, a new anthropomorphic moving ribcage combined with a 3D tumor positioning system to move target inserts within static lungs. Methods: The new rib cage design is described and its motion is evaluated using Vicon Nexus, a commercial 3D motion tracking system. CT studies at inhale and exhale position are used to study the effect of rib motion and tissue equivalence. Results: The 3D target positioning system and the rib cage have millimetre accuracy. Each axis of motion can reproduce given trajectories from files or individually programmed sinusoidal motion in terms of amplitude, period, and phase shift. The maximum rib motion ranges from 7 to 20 mm SI and from 0.3 to 3.7 mm AP with LR motion less than 1 mm. The repeatability between cycles is within 0.16 mm root mean square error. The agreement between CT electron and mass density for skin, ribcage, spine hard and inner bone as well as cartilage is within 3%. Conclusions: The MAESTRO phantom is a useful research tool that produces programmable 3D rib motions which can be synchronized with 3D internal target motion. The easily accessible static lungs enable the use of a wide range of inserts or can be filled with lung tissue equivalent and deformed using the target motion system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fully Mechanically Controlled Automated Electron Microscopic Tomography

Knowledge of three-dimensional (3D) structures of each individual particles of asymmetric and flexible proteins is essential in understanding those proteins' functions; but their structures are difficult to determine. Electron tomography (ET) provides a tool for imaging a single and unique biological object from a series of tilted angles, but it is challenging to image a single protein for three-dimensional (3D) reconstruction due to the imperfect mechanical control capability of the specimen goniometer under both a medium to high magnification (approximately 50,000-160,000×) and an optimized beam coherence condition. Here, we report a fully mechanical control method for automating ET data acquisition without using beam tilt/shift processes. This method could reduce the accumulation of beam tilt/shift that used to compensate the error from the mechanical control, but downgraded the beam coherence. Our method was developed by minimizing the error of the target object center during the tilting process through a closed-loop proportional-integral (PI) control algorithm. The validations by both negative staining (NS) and cryo-electron microscopy (cryo-EM) suggest that this method has a comparable capability to other ET methods in tracking target proteins while maintaining optimized beam coherence conditions for imaging.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Can the GPM IMERG Final Product Accurately Represent MCSs’ Precipitation Characteristics over the Central and Eastern United States?

Mesoscale convective systems (MCSs) play an important role in water and energy cycles as they produce heavy rainfall and modify the radiative profile in the tropics and midlatitudes. An accurate representation of MCSs’ rainfall is therefore crucial in understanding their impact on the climate system. The V06B Integrated Multisatellite Retrievals from Global Precipitation Measurement (IMERG) half-hourly precipitation final product is a useful tool to study the precipitation characteristics of MCSs because of its global coverage and fine spatiotemporal resolutions. However, errors and uncertainties in IMERG should be quantified before applying it to hydrology and climate applications. This study evaluates IMERG performance on capturing and detecting MCSs’ precipitation in the central and eastern United States during a 3-yr study period against the radar-based Stage IV product. The tracked MCSs are divided into four seasons and are analyzed separately for both datasets. IMERG shows a wet bias in total precipitation but a dry bias in hourly mean precipitation during all seasons due to the false classification of nonprecipitating pixels as precipitating. These false alarm events are possibly caused by evaporation under the cloud base or the misrepresentation of MCS cold anvil regions as precipitating clouds by the algorithm. IMERG agrees reasonably well with Stage IV in terms of the seasonal spatial distribution and diurnal cycle of MCSs precipitation. A relative humidity (RH)-based correction has been applied to the IMERG precipitation product, which helps reduce the number of false alarm pixels and improves the overall performance of IMERG with respect to Stage IV.

54 ENVIRONMENTAL SCIENCES↗

Unsupervised Parsing of Gaze Data with a Beta-process Vector Auto-regressive Hidden Markov Model

The first stage of analyzing eye-tracking data is commonly to code the data into sequences of fixations and saccades. This process is usually automated using simple, predetermined rules for classifying ranges of the time series into events, such as “if the dispersion of gaze samples is lower than the threshold, then code as a fixation; otherwise code as a saccade.” More recent approaches incorporate additional eye-movement categories in automated parsing algorithms, particularly glissades, by using time-varying, data-driven thresholds. We describe an alternative approach using the beta-process auto-regressive hidden Markov model (BP-AR-HMM). The BP-AR-HMM offers two main advantages over existing frameworks. First, it provides a statistical model for eye movement classification rather than a single estimate. Second, the BP-AR-HMM uses a latent process to model the number and nature of the types of eye-movements and hence is not constrained to predetermined categories. We applied the BP-AR-HMM both to high-sampling rate gaze data from Andersson, Larsson, Holmqvist, Stridh, and Nyström (2016) and to low-sampling rate data from the DIEM project (Mital, Smith, Hill, & Henderson, 2011). Driven by the data properties, the BP-AR-HMM identified clusters of samples resembling saccades, fixations and smooth pursuit, and a category that approximately corresponds to glissades (as well as blinks, errors, etc.). The BP-AR-HMM serves as an effective algorithm for data-driven event parsing alone or as an initial step in exploring the characteristics of gaze data sets.

eye tracking, fixation, fixation, saccade, smooth ↗