Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Detailed characterization of the LLNL imaging proton spectrometer

Ultra-intense short pulse lasers incident on solid targets (e.g., thin Au foils) produce well collimated, broad-spectrum proton beams. These proton beams can be used to characterize magnetic fields, electric fields, and density gradients in high energy-density systems. The LLNL-Imaging Proton Spectrometer (L-IPS) was designed and built [H. Chen et al., Rev. Sci. Instrum. 81, 10D314 (2010)] for use with such laser produced proton beams. The L-IPS has an energy range of 50 keV-40 MeV with a resolving power (E/dE) of about 275 at 1 MeV and 21 at 20 MeV, as well as a single spatial imaging axis. In order to better characterize the dispersion and imaging capability of this diagnostic, a 3D finite element analysis solver is used to calculate the magnetic field of the L-IPS. Particle trajectories are then obtained via numerical integration to determine the dispersion relation of the L-IPS in both energy and angular space.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

INCORPORATING DYNAMIC 3D SIMULATION INTO PRA

Through continued advancement in computational resources, development that was previously done by trial and error production is now performed through computer simulation. These virtual physical representations have the potential to provide accurate and valid modeling results and are being used in many different technical fields. Risk assessment now has the opportunity to use 3D simulation to improve analysis results and insights, especially for external event analysis. By using simulations, the modeler only has to determine the likelihood of an event without having to also predict the results of that event. The 3D simulation automatically determines not only the outcome of the event, but when those failures occur. How can we effectively incorporate 3D simulation into traditional PRA? Most PRA plant modeling is made up of components with different failure modes, probabilities, and rates. Typically, these components are grouped into various systems and then are modeled together (in different combinations) as a “system” with logic structures to form fault trees. Applicable fault trees are combined through scenarios, typically represented by event tree models. Though this method gives us failure results for a given model, it has limitations when it comes to time-based dependencies or dependencies that are coupled to physical processes which may themselves be space- or time-dependent. Since, failures from a 3D simulation are naturally time related, they should be used in that manner. In our simulation approach, traditional static models are converted into an equivalent state diagram representation with start states, probabilistic driven movements between states and terminal states. As the state model is run repeatedly, it converges to the same results as the PRA model in cases where time-related factors are not important. In cases where timing considerations are important (e.g., when events are dependent upon each other), then the simulation approach will typically provide superior results and insights. We also couple the state model with the dynamic 3D simulation analysis representing events (such as flooding) to determine which (if any) components fail. Not only does the simulation take into account any failed items from the state model, but any failures caused by the simulation are incorporated back into the state model and factored into the overall results. Using this method we incorporate accurate 3D simulation results, eliminate static-based PRA issues, and have time ordered failure information.

3D Simulation↗

Analysis of ancient-river systems by 3D seismic time-slice technique: A case study in northeast Malay Basin, offshore Terengganu, Malaysia

Fluvial sandstones constitute one of the major clastic petroleum reservoir types in many sedimentary basins around the world. This study is based on the analysis of high-resolution, shallow (seabed to 500 m depth) 3D seismic data which generated three-dimensional (3D) time slices that provide exceptional imaging of the geometry, dimension and temporal and spatial distribution of fluvial channels. The study area is in the northeast of Malay Basin about 280 km to the east of Terengganu offshore. The Malay Basin comprises a thick (> 8 km), rift to post-rift Oligo-Miocene to Pliocene basin-fill. The youngest (Miocene to Pliocene), post-rift succession is dominated by a thick (1–5 km), cyclic succession of coastal plain and coastal deposits, which accumulated in a humid-tropical climatic setting. This study focuses on the Pleistocene to Recent (500 m thick) succession, which comprises a range of seismic facies analysis of the two-dimensional (2D) seismic sections, mainly reflecting changes in fluvial channel style and river architecture. The succession has been divided into four seismic units (Unit S1-S4), bounded by basin-wide strata surfaces. Two types of boundaries have been identified: 1) a boundary that is defined by a regionally-extensive erosion surface at the base of a prominent incised valley (S3 and S4); 2) a sequence boundary that is defined by more weakly-incised, straight and low-sinuosity channels which is interpreted as low-stand alluvial bypass channel systems (S1 and S2). Each unit displays a predictable vertical change of the channel pattern and scale, with wide low-sinuosity channels at the base passing gradationally upwards into narrow high-sinuosity channels at the top. The wide variation in channel style and size is interpreted to be controlled mainly by the sea-level fluctuations on the widely flat Sunda land Platform.

58 GEOSCIENCES↗

Measurements of 3D slip velocities and plasma column lengths of a gliding arc discharge

A non-thermal gliding arc discharge was generated at atmospheric pressure in an air flow. The dynamics of the plasma column and tracer particles were recorded using two synchronized high-speed cameras. Whereas the data analysis for such systems has previously been performed in 2D (analyzing the single camera image), we provide here a 3D data analysis that includes 3D reconstructions of the plasma column and 3D particle tracking velocimetry based on discrete tomography methods. The 3D analysis, in particular, the determination of the 3D slip velocity between the plasma column and the gas flow, gives more realistic insight into the convection cooling process. Additionally, with the determination of the 3D slip velocity and the 3D length of the plasma column, we give more accurate estimates for the drag force, the electric field strength, the power per unit length, and the radius of the conducting zone of the plasma column.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

User's Manual for DuctE3D: A Program for 3D Euler Unsteady Aerodynamic and Aeroelastic Analysis of Ducted Fans

The program DuctE3D is used for steady or unsteady aerodynamic and aeroelastic analysis of ducted fans. This guide describes the input data required and the output files generated, in using DuctE3D. The analysis solves three dimensional unsteady, compressible Euler equations to obtain the aerodynamic forces. A normal mode structural analysis is used to obtain the aeroelastic equations, which are solved using either the time domain or the frequency domain solution method. Sample input and output files are included in this guide for steady aerodynamic analysis and aeroelastic analysis of an isolated fan row.

Srivastava, R.↗

Multi-Scale Analysis of Effective Mechanical Properties of 3D Woven Composite Materials

This work aims to compute and analyze the mechanical properties of 3D woven composite materials that share the same yarn structure but differ in their matrix porosity and fiber volume fraction. Assuming linear elastic behavior, the software PuMA, developed at NASA, was used to characterize the different composites from their constituents' data averaging their elastic properties in three main directions to obtain their effective orthotropic mechanical properties. This was performed in three steps: firstly, the different phases (yarns/matrix) were analyzed as anisotropic materials separately at the micro-scale; then, the results from these analyses were homogenized and used to obtain the anisotropic elasticity tensor at the meso-scale for the different woven materials; and finally, assuming orthotropic mechanical behavior for the unit cell the mechanical properties were obtained at the macro-scale. The 3D woven composite materials selected for this study are made of phenolic resin with porosity values between 0 and 0.6, and resin infiltrated carbon fiber with volume fractions between 0.5 and 0.9 for the yarns. Results from PuMA were validated with external FEA simulations for the non-porous 3D woven material with a fiber volume fraction of 0.9 in the yarns. Results will be included in the final paper after completing the study detailed in Section II.

Sergio Fraile Izquierdo↗

Anatomical background and generalized detectability in tomosynthesis and cone-beam CT

Purpose: Anatomical background presents a major impediment to detectability in 2D radiography as well as 3D tomosynthesis and cone-beam CT (CBCT). This article incorporates theoretical and experimental analysis of anatomical background ''noise'' in cascaded systems analysis of 2D and 3D imaging performance to yield ''generalized'' metrics of noise-equivalent quanta (NEQ) and detectability index as a function of the orbital extent of the (circular arc) source-detector orbit. Methods: A physical phantom was designed based on principles of fractal self-similarity to exhibit power-law spectral density ({kappa}/f{sup {beta}}) comparable to various anatomical sites (e.g., breast and lung). Background power spectra [S{sub B}(f)] were computed as a function of source-detector orbital extent, including tomosynthesis ({approx}10 deg. - 180 deg.) and CBCT (180 deg. +fan to 360 deg.) under two acquisition schemes: (1) Constant angular separation between projections (variable dose) and (2) constant total number of projections (constant dose). The resulting S{sub B} was incorporated in the generalized NEQ, and detectability index was computed from 3D cascaded systems analysis for a variety of imaging tasks. Results: The phantom yielded power-law spectra within the expected spatial frequency range, quantifying the dependence of clutter magnitude ({kappa}) and correlation ({beta}) with increasing tomosynthesis angle. Incorporation of S{sub B} in the 3D NEQ provided a useful framework for analyzing the tradeoffs among anatomical, quantum, and electronic noise with dose and orbital extent. Distinct implications are posed for breast and chest tomosynthesis imaging system design--applications varying significantly in {kappa} and {beta}, and imaging task and, therefore, in optimal selection of orbital extent, number of projections, and dose. For example, low-frequency tasks (e.g., soft-tissue masses or nodules) tend to benefit from larger orbital extent and more fully 3D tomographic imaging, whereas high-frequency tasks (e.g., microcalcifications) require careful, application-specific selection of orbital extent and number of projections to minimize negative effects of quantum and electronic noise. Conclusions: The complex tradeoffs among anatomical background, quantum noise, and electronic noise in projection imaging, tomosynthesis, and CBCT can be described by generalized cascaded systems analysis, providing a useful framework for system design and optimization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Local plate/rod descriptors of 3D trabecular bone micro-CT images from medial axis topologic analysis

Purpose: Trabecular bone microarchitecture is made of a complex network of plate and rod structures evolving with age and disease. The purpose of this article is to propose a new 3D local analysis method for the quantitative assessment of parameters related to the geometry of trabecular bone microarchitecture. Methods: The method is based on the topologic classification of the medial axis of the 3D image into branches, rods, and plates. Thanks to the reversibility of the medial axis, the classification is next extended to the whole 3D image. Finally, the percentages of rods and plates as well as their mean thicknesses are calculated. The method was applied both to simulated test images and 3D micro-CT images of human trabecular bone. Results: The classification of simulated phantoms made of plates and rods shows that the maximum error in the quantitative percentages of plate and rods is less than 6% and smaller than with the structure model index (SMI). Micro-CT images of human femoral bone taken in osteoporosis and early or advanced osteoarthritis were analyzed. Despite the large physiological variability, the present method avoids the underestimation of rods observed with other local methods. The relative percentages of rods and plates were not significantly different between osteoarthritis and osteoporotic groups, whereas their absolute percentages were in relation to an increase of rod and plate thicknesses in advanced osteoarthritis with also higher relative and absolute number of nodes. Conclusions: The proposed method is model-independent, robust to surface irregularities, and enables geometrical characterization of not only skeletal structures but entire 3D images. Its application provided more accurate results than the standard SMI on simple simulated phantoms, but the discrepancy observed on the advanced osteoarthritis group raises questions that will require further investigations. The systematic use of such a local method in the characterization of trabecular bone samples could provide new insight in bone microarchitecture changes related to bone diseases or to those induced by drugs or therapy.

60 APPLIED LIFE SCIENCES↗

Analysis of Metal Site Preference and Electronic Structure of Brownmillerite-Phase Oxides (A[subscript 2]B'[subscript x]B[subscript 2-x]O[subscript 5]; A=Ca, Sr; B'/B=Al, Mn, Fe, Co) by X-ray Absorption Near-Edge Spectroscopy

X-ray absorption near-edge spectroscopic (XANES) measurements of the Fe and Co K-edges for a series of Brownmillerite-type transition-metal oxides (A{sub 2}B{prime}{sub x}B{sub 2-x}O{sub 5}; A = Ca, Sr; B{prime}/B = Al, Mn, Fe, Co) have been made. In these compounds, the metal atoms are present in both octahedral and tetrahedral coordination environments. The spectra were interpreted with the aid of electronic structure calculations. Significant changes in intensity and energy were observed in the Fe K-edge spectra as the average Fe{sup 3+} coordination number (CN) was changed from 5.5 (Ca{sub 2}AlFeO{sub 5}) to 4.2 (Ca{sub 2}FeMnO{sub 5}). In Ca{sub 2}Co{sub x}Fe{sub 2-x}O{sub 5}, the Fe K- and Co K-edge XANES spectra indicated that Fe has a slight octahedral site preference in these series. This confirmed that size effects play a significant role in controlling the site preference of metal atoms in these compounds. The change in the average Fe CN with Co substitution was examined by analysis of a 3D plot, which compared all of the changes observed in the spectra. This type of analysis gives an accurate depiction of the change in Fe CN as compared to standard materials. The Fe K-edge peak intensities in Ca{sub 2-y}Sr{sub y}Fe{sub 2}O{sub 5} decreased with higher values of y, a result of decreased Fe 4p(3d)-O 2p overlap with increasing Sr concentration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A numerical study of the meso-structure variability in the compaction process of prepreg platelet molded composites

Compaction deformations in a thermoplastic composite system molded from chopped prepreg platelets were analyzed to obtain statistical distributions of local distortions that define the final consolidated meso-structure. This study provides an insight into and allows quantification of the intrinsic geometric variability of the composite meso-structure that controls the variability of the effective composite mechanical properties. A two-phase viscoelastic finite element model was utilized to treat the behavior of molten prepreg platelets, which were assumed to be incompressible and inextensible in the fiber direction during processing. A two-step simulation procedure with discretely modeled platelets and platelet-to-platelet contacts is proposed. The analysis begins with a drop simulation of the uncontrolled material deposition followed by a 3D finite element analysis of the preform compaction and bulk material flow. The proposed model provides a method for generating a composite meso-structure ab initio starting from a statistical sampling of the initial conditions for platelet deposition. The predicted platelet thickness distribution, intra-platelet fiber waviness and out-of-plane platelet undulations were found to be in good agreement with experimental measurements. An estimate of the volume of resin pockets was inferred from the compaction simulation.

36 MATERIALS SCIENCE↗

Quantitative microstructural investigation of 3D-printed and cast cement pastes using micro-computed tomography and image analysis

Highlights: • Processing alters the microstructure in 3D-printed lamellar cubic element. • A unique patterned and connected pore microstructure network exists. • Micro-channels are connected through micro-pores present at interfaces regions. • Three distinct pore volume domains exists in hardened microstructure. • Volume and frequency of pore, hydrated, and unhydrated clusters are dissimilar. Microstructural phases and mechanical properties of lamellar 3D-printed and cast hardened cement paste (hcp) elements were investigated using a lab-based X-ray microscope at two levels of magnification (0.4× and 4×). K-means clustering was used for quantitative image analysis. The entire volume of intact 3-days-old 3D-printed and cast hcp elements was characterized at 0.4× magnification. Three microstructural features (macro-pores, micro-channels, and interfacial micro-pores) were found to reside in three distinct pore size domains. The largest pores of the 3D-printed element were larger than the largest pores of the reference cast hcp element. Moreover, the smallest pore sizes of the 3D-printed element were found to be smaller than those present in the cast counterparts. Micro-channels were found to be connected to one another through the micro-pores present at interfacial regions, indicating the presence of a uniquely patterned and interconnected pore network. The role of locally weak and porous interfaces on mechanical response and fracture properties is discussed.

36 MATERIALS SCIENCE↗

3D distribution of interstellar medium in the Galaxy: Preparation for analysis of Gaia observations

Accurate and detailed three-dimensional (3D) maps of Galactic interstellar medium (ISM) are still lacking. One way to obtain such 3D descriptions is to record a large set of individual absorption or reddening measurements toward target stars located at various known distances and directions. The inversion of these measurements using a tomographic method can produce spatial distribution of the ISM. Until recently absorption data were very limited and distances to the target stars are still uncertain, but the situation will greatly improve thanks to current and future massive stellar surveys from ground, and to Gaia mission. To prepare absorption data for inversion from a huge number of stellar spectra, automated tools are needed. We have developed various spectral analysis tools adapted to different type of spectra, early- or late- type star. We also have used diffuse interstellar bands (DIBs) to trace IS structures and kinematics. Although we do not know yet their carriers, they can be a promising tool to trace distant interstellar clouds or Galactic arms. We present some examples of the interstellar fitting and show the potentiality of DIBs in tracing the ISM. We will also briefly show and comment the latest 3D map of the local ISM which reveal nearby cloud complexes and cavities.

79 ASTRONOMY AND ASTROPHYSICS↗

Three-dimensional imaging of nanoscale materials by using coherent x-rays

X-ray crystallography is currently the primary methodology used to determine the 3D structure of materials and macromolecules. However, many nanostructures, disordered materials, biomaterials, hybrid materials and biological specimens are noncrystalline and, hence, their structures are not accessible by X-ray crystallography. Probing these structures therefore requires the employment of different approaches. A very promising technique currently under rapid development is X-ray diffraction microscopy (or lensless imaging), in which the coherent X-ray diffraction pattern of a noncrystalline specimen is measured and then directly phased to obtain a high-resolution image. Through the DOE support over the past three years, we have applied X-ray diffraction microscopy to quantitative imaging of GaN quantum dot particles, and revealed the internal GaN-Ga2O3 core shell structure in three dimensions. By exploiting the abrupt change in the scattering cross-section near electronic resonances, we carried out the first experimental demonstration of resonant X-ray diffraction microscopy for element specific imaging. We performed nondestructive and quantitative imaging of buried Bi structures inside a Si crystal by directly phasing coherent X-ray diffraction patterns acquired below and above the Bi M5 edge. We have also applied X-ray diffraction microscopy to nondestructive imaging of mineral crystals inside biological composite materials - intramuscular fish bone - at the nanometer scale resolution. We identified mineral crystals in collagen fibrils at different stages of mineralization and proposed a dynamic mechanism to account for the nucleation and growth of mineral crystals in the collagen matrix. In addition, we have also discovered a novel 3D imaging modality, denoted ankylography, which allows for complete 3D structure determination without the necessity of sample titling or scanning. We showed that when the diffraction pattern of a finite object is sampled at a sufficiently fine scale on the Ewald sphere, the 3D structure of the object is determined by the 2D spherical pattern. We confirmed the theoretical analysis by performing 3D numerical reconstructions of a sodium silicate glass structure at 2 A resolution from a 2D spherical diffraction pattern alone. As X-ray free electron lasers are under rapid development worldwide, ankylography may open up a new horizon to obtain the 3D structure of a non-crystalline specimen from a single pulse and allow time-resolved 3D structure determination of disordered materials.

36 MATERIALS SCIENCE↗