Search NASA⌕ Search

SEARCH · Search NASA

Results for “Capacitance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Modeling and Mitigation of Multi-Loops Related Device Overvoltage in Three Level Active Neutral Point Clamped Converter

This paper establishes an analytical model for the device drain-source overvoltage related to the two loops in three level active neutral point clamped (3L-ANPC) converters. Taking into account the non-linear device output capacitance, two commonly used modulations are investigated in detail. The result shows that the line switching frequency device usually has higher overvoltage, and the switching speed of the high switching frequency device is not strongly influenced by the multiple loops. By keeping the non-active clamping switch off, the effect of the non-linear device output capacitance can be significantly mitigated, which helps reduce the overvoltage. Moreover, the loop inductance can be reduced with vertical loop layout and magnetic cancellation in PCB and busbar design. A 500 kVA 3L-ANPC converter using SiC MOSFETs is built and tested. The experimental results validate the overvoltage model of the two modulations as well as the busbar design. With the non-active clamping switch off, the overvoltage of both the high and line switching frequency devices is significantly reduced, which helps achieve higher switching speed.

Model↗

Effect of High Temperature Storage on AC Characteristics of Polymer Tantalum Capacitors

Replacement of MnO2 with conductive polymers as cathode materials in chip tantalum capacitors allows for a substantial reduction of the equivalent series resistance (ESR), improvement of frequency characteristics, and elimination of the possibility of ignition during failures. One of the drawbacks of chip polymer tantalum capacitors (CPTCs) is a relatively poor long-term stability at high temperatures. In this work, variations of capacitance, dissipation factor, and ESR in different types of capacitors including automotive grade parts from three manufacturers have been monitored during storage at temperatures from 100 ºC to 175 ºC for up to 18,000 hours. Results show that ESR is the most and capacitance the least sensitive to degradation parameter. Times to parametric failures have been simulated using a Weibull-Arrhenius model that allowed for assessments of activation energies of the degradation and prediction of times to failure at the use temperature. Degradation of CPTCs was explained by thermo-oxidative processes in conductive polymers that result in exponential increasing of the resistivity with time of ageing. This process starts after a certain incubation period that depends on packaging materials and design and corresponds to the time that is necessary to form delamination between the encapsulating molding compound and lead frame. The effectiveness of the existing qualification procedures to assure stable operation of CPTCs is discussed.

Alexander A Teverovsky↗

Effect of High Temperature Storage on AC Characteristics of Polymer Tantalum Capacitors

Replacement of MnO2 with conductive polymers as cathode materials in chip tantalum capacitors allows for a substantial reduction of the equivalent series resistance (ESR), improvement of frequency characteristics, and elimination of the possibility of ignition during failures. One of the drawbacks of chip polymer tantalum capacitors (CPTCs) is a relatively poor long-term stability at high temperatures. In this work, variations of capacitance, dissipation factor, and ESR in different types of capacitors including automotive grade parts from three manufacturers have been monitored during storage at temperatures from 100 ºC to 175 ºC for up to 18,000 hours. Results show that ESR is the most and capacitance the least sensitive to degradation parameter. Times to parametric failures have been simulated using a Weibull-Arrhenius model that allowed for assessments of activation energies of the degradation and prediction of times to failure at the use temperature. Degradation of CPTCs was explained by thermo-oxidative processes in conductive polymers that result in exponential increasing of the resistivity with time of ageing. This process starts after a certain incubation period that depends on packaging materials and design and corresponds to the time that is necessary to form delamination between the encapsulating molding compound and lead frame. The effectiveness of the existing qualification procedures to assure stable operation of CPTCs is discussed.

Aging↗

Effect of High Temperature Storage on AC Characteristics of Polymer Tantalum Capacitors

Replacement of MnO2 with conductive polymers as cathode materials in chip tantalum capacitors allows for a substantial reduction of the equivalent series resistance (ESR), improvement of frequency characteristics, and elimination of the possibility of ignition during failures. One of the drawbacks of chip polymer tantalum capacitors (CPTCs) is a relatively poor long-term stability at high temperatures. In this work, variations of capacitance, dissipation factor, and ESR in different types of capacitors including automotive grade parts from three manufacturers have been monitored during storage at temperatures from 100 ºC to 175 ºC for up to 18,000 hours. Results show that ESR is the most and capacitance the least sensitive to degradation parameter. Times to parametric failures have been simulated using a Weibull-Arrhenius model that allowed for assessments of activation energies of the degradation and prediction of times to failure at the use temperature. Degradation of CPTCs was explained by thermo-oxidative processes in conductive polymers that result in exponential increasing of the resistivity with time of ageing. This process starts after a certain incubation period that depends on packaging materials and design and corresponds to the time that is necessary to form delamination between the encapsulating molding compound and lead frame. The effectiveness of the existing qualification procedures to assure stable operation of CPTCs is discussed.

Aging↗

Effect of High Temperature Storage on AC Characteristics of Polymer Tantalum Capacitors

Replacement of MnO2 with conductive polymers as cathode materials in chip tantalum capacitors allows for a substantial reduction of the equivalent series resistance (ESR), improvement of frequency characteristics, and elimination of the possibility of ignition during failures. One of the drawbacks of chip polymer tantalum capacitors (CPTCs) is a relatively poor long-term stability at high temperatures. In this work, variations of capacitance, dissipation factor, and ESR in different types of capacitors including automotive grade parts from three manufacturers have been monitored during storage at temperatures from 100 ºC to 175 ºC for up to 18,000 hours. Results show that ESR is the most and capacitance the least sensitive parameter to degradation. Times to parametric failures have been simulated using a Weibull-Arrhenius model that allowed for assessments of activation energies of the degradation and prediction of times to failure at the use temperature. Degradation of CPTCs was explained by thermo-oxidative processes in conductive polymers that result in exponential increase of the resistivity with time of aging. This process starts after a certain incubation period that depends on packaging materials and design and corresponds to the time that is necessary to form delamination between the encapsulating molding compound and lead frame. The effectiveness of the existing qualification procedures to assure stable operation of CPTCs is discussed.

high temperature storage (HTS)↗

A Study on Effect of Tuning Capacitor in Dynamic Radioisotope Power Systems

This study presents the effect of tuning capacitors on the power factor and power output of a gas spring-based free-piston Stirling convertor—Advanced Stirling convertor—when the convertor runs on a forced-oscillation type controller. More specifically, this paper studies how off-nominal tuning capacitance values affects the Stirling convertor in terms of the piston stability and electrical power output, when the convertor is operated by forced-oscillation type controller, such as an alternating current bus controller, and operating conditions of the convertor are unchanged. It has been widely known that tuning capacitors are important circuit components to stabilize the piston amplitude of the free-piston Stirling convertors and correct the power factor for high electrical power output. Recent modeling analysis conducted by NASA Glenn Research Center, however, suggests that while the stability of the convertor is affected by the tuning capacitor value, the power factor and the electrical power output are not affected by the tuning capacitor value, as long as the convertor is controlled by a forced-oscillation controller and the convertor operating conditions, such as the hot-end/cold-end temperatures, piston amplitude, and operating frequency, are unchanged. To verify the modeling analysis results, a test setup is devised where the convertor is controlled by a forced-oscillation controller and the piston amplitude, hot-end temperature, and charge pressure are controlled to 4mm, 760˚C, and 485psig, respectively, while the tuning capacitor value is changed from its nominal value, 840μF to 1040μF and 1240μF. Furthermore, the vibration test results of the same convertor with the three tuning capacitor values are also presented in this paper to show the effect of the tuning capacitor value on the convertor stability. The test results suggest that when the convertor is controlled by a forced-oscillation, the tuning capacitor value determines the convertor stability but not the power factor nor electrical power output. Therefore, the tuning capacitance value in forced-oscillation controllers should be determined based on the convertor stability, system mass, and volume.

Free-Piston Stirling Convertor Controller↗

Degradation of Aluminum and Tantalum Wet Electrolytic Capacitors during High Temperature Storage

Aluminum electrolytic capacitors (AEC) are available to higher ranges of capacitance and voltage compared to tantalum electrolytic capacitors (TEC). However, evaporation of the electrolyte during operation or storage of conventional AEC that is accelerated with temperature does not allow use of these parts in space electronics. Instead, for systems requiring large value capacitors and high operating voltages, designers must use banks of TECs that increases substantially the size and weight of electronic modules. Development of hermetically sealed AECs might be beneficial for space systems provided the necessary reliability is assured. Increase in leakage current during storage of AEC is well known and is often explained by dissolution of aluminum oxide in electrolyte. However, other possible mechanisms of this effect have not been discussed. Although hermetically sealed TEC have been used in space systems for years, there is a lack of information about the effects of storage on their characteristics that is of great interest as a comparison for aluminum capacitors. This work explores degradation of AC characteristics (capacitance, dissipation factor, and equivalent series resistance) and DC characteristics (leakage and absorption currents) in different types of aluminum and tantalum hermetically sealed capacitors during long-term storage at high temperatures (100 °C, 125 °C, and 150 °C). It is shown that leakage currents are degrading in both types of capacitors, but this degradation is reversible after bias application. Mechanisms of degradation are discussed, and explanations based on the processes common for both types of capacitors are suggested. Problems associated with assessments of hermeticity and evaporation of the electrolyte in hermetically sealed capacitors are analyzed.

Alexander Teverovsky↗

Investigation of Hardware and Instrumentation to Measure Hand Grasp Activity with the Spacesuit Gloves

Introduction: During the 2022 suited injury summit, it was hypothesized that there will be concerns for hand and glove injuries for future exploration space missions, especially given the fact that the “total number of Extravehicular activity (EVA) hours and frequency” for lunar surface missions is expected to vastly increase [1]. It has been reported that the hands experienced the greatest “absolute numbers” of reported injuries and far exceeds other injuries during EVA [1, 2]. It was reported that the most fatiguing part of the surface EVA was the repetitive gripping tasks [3]. It was recommended that a “glove sub-team” be created to look at possible injury mechanism and mitigation strategies. Some of the recommendations that were suggested [1] are as follows: examine hand fatigue, utilize motion capture, examine the duration and frequency of hand movements, and identify frequent hand motions. We started assessing hardware and instrumentation to measure hand grasp activity in the pressurized glove environment. The purpose of this test was to perform a hardware evaluation for motion capture (MoCap) gloves obtained from StretchSense (Auckland, New Zealand). The specific gloves used were the Pro Fidelity and SuperSplay to determine the repeatability, reliability, feasibility, and useability inside of a pressurized gloved environment. Methods: The MoCap gloves were customized (e.g., battery/Bluetooth pack relocated to upper arm) to better suit the pressurized testing environment and protect the subject from unintentional injury (Fig. 1). Fourteen total subjects from different demographics (i.e., gender and pressurized glove experience level) participated in this test series. Testing included one session each of a baseline data collection (NASA Johnson Space Center (JSC) building 21) and a spacesuit glove box (Fig. 2 at JSC building 7 room 2027) data collection (under vacuum down to 4.3 psid), where each session lasted 3-5 hours. Controlled and reproducible tasks to systematically evaluate the repeatability and reliability of the hardware were performed during baseline data collection. Additionally, subjects performed simulated EVA-like tasks in a pressurized gloved environment. For all sessions, MoCap gloves were placed on each of the subjects’ hands and the signal from it, or the raw capacitance (Fig. 3), was analysed. The raw capacitance was used to estimate the open and closed hand states between the testing conditions and allow us to provide an offset caused by the pressurized environment. Results & Discussion: Initial observation with the bare hands (baseline) condition showed that the MoCap gloves appeared to track grasping and releasing of the fingers (opening and closing fist) with both high- and low-speed conditions, while adduction and abduction of the fingers were not relatively tracked. A hardware evaluation was done outside of the glove box to assess the reliability and repeatability of the MoCap glove. In one task, a point force was applied to various locations on the back of the hand. When the point force was applied to the space between the 1st digit and the pointer finger, there was a noticeable distortion to the MoCap data. Another task examining an increasing force from a 10 lb. sandbag applied to the back of the hand while lying flat on a table, showed a constant flat line with only a distortion when the weight was increased or added to the back of the hand. Fig. 3 shows an object relocation task where you can see when each individual finger “opened” and “closed” (changed position) when picking up and setting down the dumbbell. When the fingers were stationary, the signal remained relatively flat compared to the peaks and valleys that can be observed in Fig. 3. This study showed promising results and imperative input into an attempt to discriminate between hand states across various functional tasks and should be evaluated with context to the repeatability and reliability outcomes. Depending on the task done inside of the pressurized glove box environment and outside, the results appear to be affected by many different factors (i.e., drift, pressure, hand size, etc.). Significance: If this hardware proves to be reliable and repeatable in determining the open and closed hand states then this may provide critical insight into assisting in the characterization of the pressurized gloved environment and the effect on crew member exertion level. Ultimately, this tool will provide useful data for quantifying the repetitive nature of EVA training and tasks. Acknowledgments: The authors would like to acknowledge the NASA Mars Campaign Office for providing funding for this research. Lastly, thanks to all the engineers and technicians at NASA JSC who helped with this data collection. References: [1] Reiber, et al. (2022), NASA/TM-20220007605; [2] Scheuring, et al. (2009), Av., Sp., and Envir. Med. 80(2). [3] Scheuring, et al. (2007), NASA/TM–2007–214755.

Rachel L Thompson↗

Wideband fixed-tuned SIS receiver for 200-GHz operation

We report on the design and development of a heterodyne receiver, designed to cover the frequency range 176-256 GHz. This receiver incorporates a niobium superconductor-insulator-superconductor (SIS) tunnel junction mixer, which, chiefly for reasons of reliability and ease of operation, is a fixed-tuned waveguide design. On-chip tuning is provided to resonate out the junction's geometric capacitance and produce a good match to the waveguide circuit. Laboratory measurements on the first test receiver indicate that the required input bandwidth (about 40%) is achieved with an average receiver noise temperature of below 50 K. Mixer conversion gain is observed at some frequencies, and the lowest measured receiver noise is less than 30 K. Furthermore, the SIS mixer used in this receiver is of simple construction, is easy to assemble and is therefore a good candidate for duplication.

RECEIVER NOISE TEMPERATURE↗

A comparison of soil moisture sensors for space flight applications

Plants will be an important part of future long-term space missions. Automated plant growth systems require accurate and reliable methods of monitoring soil moisture levels. There are a number of different methods to accomplish this task. This study evaluated sensors using the capacitance method (ECH2O), the heat-pulse method (TMAS), and tensiometers, compared to soil water loss measured gravimetrically in a side-by-side test. The experiment monitored evaporative losses from substrate compartments filled with 1- to 2-mm baked calcinated clay media. The ECH2O data correlated well with the gravimetric measurements, but over a limited range of soil moisture. The averaged TMAS sensor data overstated soil moisture content levels. The tensiometer data appeared to track evaporative losses in the 0.5- to 2.5-kPa range of matric potential that corresponds to the water content needed to grow plants. This small range is characteristic of large particle media, and thus high-resolution tensiometers are required to distinguish changing moisture contents in this range.

NASA Center KSC↗

Mapping Electrical Crosstalk in Pixelated Sensor Arrays

Electronic coupling effects such as Inter-Pixel Capacitance (IPC) affect the quantitative interpretation of image data from CMOS, hybrid visible and infrared imagers alike. Existing methods of characterizing IPC do not provide a map of the spatial variation of IPC over all pixels. We demonstrate a deterministic method that provides a direct quantitative map of the crosstalk across an imager. The approach requires only the ability to reset single pixels to an arbitrary voltage, different from the rest of the imager. No illumination source is required. Mapping IPC independently for each pixel is also made practical by the greater S/N ratio achievable for an electrical stimulus than for an optical stimulus, which is subject to both Poisson statistics and diffusion effects of photo-generated charge. The data we present illustrates a more complex picture of IPC in Teledyne HgCdTe and HyViSi focal plane arrays than is presently understood, including the presence of a newly discovered, long range IPC in the HyViSi FPA that extends tens of pixels in distance, likely stemming from extended field effects in the fully depleted substrate. The sensitivity of the measurement approach has been shown to be good enough to distinguish spatial structure in IPC of the order of 0.1%.

focal plane array↗

Considerations on Electrolytic Conductivity Measurement for Monitoring of Ionic Silver Biocide Dosing

NASA interest in ionic silver (Ag+) as a biocide for spacecraft potable water systems motivates the development of Ag+ concentration sensors to ensure nominal dosing. The electrolytic conductivity change of highly-purified potable water is linearly related to the concentration of chemically-dosed Ag+ and could serve as a useful proxy measurement, while the conductivity change during electrolytic dosing may be less so, depending on the influent water chemistry and electrolytic efficiency. Understanding and mitigating the potentially deleterious effects of Ag+ interaction with conductivity measurement systems requires investigation. Issues associated with traditional conductivity cells, which rely on wetted(typically metal or graphite) electrodes, and capacitively-coupled contactless conductivity detection (C4D) for this application are considered. Traditional conductivity cells may potentially be subject to significant excitation-induced or auto-galvanic reduction of Ag+. These may result in Ag+ depletion or electrode fouling and associated measurement error. Proper selection of electrode material, excitation parameters, and cell geometry may limit such effects. C4D uses electrodes placed outside an inert, insulating material, with dielectric polarization enabling the production of an electric field and resultant current across the analyte solution. This approach could potentially mitigate problems with Ag+ depletion and fouling by eliminating the possibility of auto-galvanic deposition and reducing the Faradaic current density. However, it is necessary to confirm C4D performance at very low conductivity levels and to determine if long-term operation produces conductive deposits, which could result in measurement error. A commercial C4D system with 1/16” (1.59 mm)outer diameter flow tubing and claimed performance in the conductivity range appropriate for this application was identified, and its sensitivity in the upper parts of this range was confirmed in a preliminary experiment. A concept for a C4D detector that could allow for full rate flow-through using planar electrodes and thin-film dielectric layers is discussed.

silver↗

Solid-State Ultracapacitor Polymer Composite

An ultracapacitor made from a polymer loaded with ceramic powder would have several advantages over current ultracapacitors and batteries. First is the possibility of it being printable, which would allow for printing the energy storage device along with the circuit instead of having to find a way to add one later without damaging the rest of the components. When not printed in a specific design for use on a printed wiring board, this type of ultracapacitor could still be cured via a mold to a shape suitable to specific applications. Many polymers maintain some flexibility even after curing, such as the silicone used in this study. The manufacturing process would also be far simpler than that of conventional ultracapacitors.In this work, solid-state ultracapacitors were made by adding the dielectric powder to a two-part polymer (resin and hardener) at the same time. The mixture was then cured in the desired shape at a low temperature until completely set. The addition of the powder to the polymer increased its dielectric properties while leaving most of its physical properties unaltered. At higher powder loading percentages, there were some physical changes as the maximum loading point was approached. To determine the efficiency of these solid-state ultracapacitors, their capacitances were tested, and their dielectric constants (DCs) were measured and compared.

energy storage↗