Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microstrip”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Dark Matter Research and the PAMELA Space Mission

On the 15th of June 2006, the PAMELA satellite-borne experiment was launched from the Bajkonur cosmodrome and since July 2006 it has been collected data. The core of the apparatus is a silicon-microstrip magnetic spectrometer combined with a time-of-flight system, a silicon-tungsten electromagnetic calorimeter, an anticoincidence system, a shower tail counter scintillator and a neutron detector. The overall devices allow precision studies of the charged cosmic radiation to be conducted over a wide energy range (100 MeV-100's GeV) with high statistics.The primary scientific goal is the measurement of the antiproton and positron energy spectra in order to search for exotic sources, such as dark matter particle annihilation. PAMELA is also searching for primordial antinuclei (He). Concomitant, but not secondary, goals are the measurements of light nuclei and their isotopes for studying the energy dependence of cosmic ray lifetimes in the Galaxy, the monitoring of the solar activity and the study of the radiation belts.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Observation of narrow states in nuclei beyond the proton drip line: {sup 15}F and {sup 16}Ne

Two high-lying states in {sup 15}F and {sup 16}Ne, unbound with respect to one-proton (1p) and two-proton (2p) emissions, have been observed in the fragmentation of {sup 17}Ne at intermediate energies. They undergo mainly sequential emissions of protons via intermediate states in {sup 14}O and {sup 15}F and have decay energies of 7.8(2) and 7.6(2) MeV, respectively. The widths of the newly observed states in {sup 15}F and {sup 16}Ne are much smaller than the Wigner limits for single-particle configurations, of 0.4(4) and 0.8({sub +8}{sup -4}) MeV, respectively. In addition, narrow widths of 0.2(2) MeV are derived for two other high-lying states in {sup 15}F with Q{sub p} of 4.9 and 6.4 MeV, which match features of the recently predicted narrow odd-parity {sup 15}F states with two valence protons in the sd shell. All energies and widths have been obtained by analyzing angular correlations of the decay products, p-p-{sup 14}O and p-p-{sup 13}N, whose trajectories have been measured by a tracking technique with silicon microstrip detectors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Test system for charge collection efficiency measurement (SYCOC) for neutron irradiated silicon sensors

One of the constraints in using standard Float Zone silicon layer as base material for tracking in particle physics is its radiation hardness. The detection efficiency is degraded by the introduction of defects in the silicon crystal and charge trapping becomes the main problem. The Charge Collection Efficiency (CCE) is a relevant parameter in order to determine the detection performance of such devices. A state-of-the-art test system named 'Systeme de mesure de collection de charge' (SYCOC) has been developed for the characterization of diode and microstrip silicon sensors before and after irradiation. The system is designed to perform Charge Collection Efficiency (CCE) and Transient Current Technique (TCT) measurements with laser and radioactive sources in a controlled environment. Initial measurements on diodes are presented. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Multi-Purpose Detector for NICA heavy-Ion Collider at JINR

The Multi-Purpose Detector (MPD) is designed to study heavy-ion collisions at the Nuclotron-based heavy Ion Collider fAcility (NICA) at JINR, Dubna. Its main components located inside a superconducting solenoid are a tracking system composed of a silicon microstrip vertex detector followed by a large volume time-projection chamber, a time-of-flight system for particle identification and a barrel electromagnetic calorimeter. A zero degree hadron calorimeter is designed specifically to measure the energy of spectators. In this paper, all parts of the apparatus are described and their tracking and particle identification parameters are discussed in some detail.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integrated back to back barrier-N-N(+) varactor diode tripler using a split-waveguide block

The back-to-back barrier-N-N(+) (bbBNN) varactor is a nonlinear device being developed for frequency multiplier applications above 100 GHz. Its symmetrical C-V characteristic, low series resistance, freedom from external bias and suitability to planarization make it an ideal choice for high frequency, low power, odd harmonic generation. In this paper, the performance of a 220-GHz waveguide tripler using, for the first time, a planar GaAs bbBNN device integrated on a quartz microstrip circuit is presented. A new split-waveguide block design has been employed to provide the proper embedding impedances to the device at the input and third harmonic output frequencies. A flange-to-flange tripling efficiency of 7% has been obtained at 220 GHz with an output power in excess of 700 mu W. This is believed to be the highest conversion efficiency yet reported for a tripler with an integrated device at this frequency. Theoretical calculations indicate that substantial improvement is possible with modest changes to the device and circuit parameters.

QUARTZ MICROSTRIP CIRCUITS↗

A One-Meter X-Band Inflatable Reflectarray Antenna

Inflatable antenna technology is being developed by JPL/NASA to enable the capabilities of low-mass, high packaging efficiency, and low-cost deployment for future spacecraft high-gain antennas. One of the technologies being studied is the inflatable microstrip reflectarray.

inflatable antenna microstrip reflectarray X-band↗

Transmission Lines for High Frequency and High Density Packaging

We report on resistivity and chemical stability of Cr/Au bilayers deposited by sputtering on three kinds of substrates: alumina, aluminum nitride and aluminum nitride coated alumina. The insertion loss of Cr/Au microstrip lines fabricated on these three substrates was low and stable after 100 cycles in the -65 degree C to 125 degree C temperature range.

high-frequency↗

Design and Performance of the Antenna-Coupled Lumped-Element Kinetic Inductance Detector

Focal plane arrays consisting of low-noise, polarisation-sensitive detectors have made possible the pioneering advances in the study of the cosmic microwave background (CMB). To make further progress, the next generation of CMB experiments (e.g. CMB-S4) will require a substantial increase in the number of detectors compared to current instruments. Arrays of kinetic inductance detectors (KIDs) provide a possible path to realising such large-format arrays owing to their intrinsic multiplexing advantage and relative cryogenic simplicity. In this paper, we report on the design of a variant of the traditional KID design: the antenna-coupled lumped-element KID. A polarisation-sensitive twin-slot antenna placed behind an optimised hemispherical lens couples power onto a thin-film superconducting microstrip line. The power is then guided into the inductive section of an aluminium KID, where it is absorbed and modifies both the resonant frequency and quality factor of the KID. We present the various aspects of the design and preliminary results from the first set of seven-element prototype arrays and compare to the expected modelled performance.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Study of Surface Roughness Effect on Super–Normal Transition of Ti/Au Transition Edge Sensor Calorimeters

We are developing transition edge sensor (TES) X-ray microcalorimeters for the future Japanese mission DIOS. It adopts microstrip readout wiring for low pixel-to-pixel crosstalk. In past samples, TES films composed of Ti and Au have not shown proper super–normal transition when it is deposited on the wiring. Assuming that surface roughness of the substrate can influence the transition, we reduced the surface roughness of the underneath layer before deposition of the TES film by using chemical mechanical polishing. We then found that the substrate becomes much smoother with a roughness of <1 nm rms and the TES film shows a proper transition.

36 MATERIALS SCIENCE↗

Fabrication of OMT-Coupled Kinetic Inductance Detector for CMB Detection

Future cosmic microwave background (CMB) experiments, including the large scale ground-based Stage Four CMB Experiment (CMB-S4), satellites, and balloons, aim to map the CMB to an unprecedented precision in order to answer several key questions in cosmology. However, to reach the target noise sensitivity, more than 100,000 detectors will be needed. Arrays of kinetic inductance detectors (KIDs) are a promising alternative for experiments that require large number of detectors due to the intrinsic multiplexing capabilities. We present the fabrication procedure for a prototype planar orthomode transducer (OMT)-coupled multi-color KID array optimized for 220/270 GHz frequency bands. These devices are made from silicon-on-insulator wafers to provide a low-loss substrate for the KIDs. The OMT couples the two polarizations of light from a wide-band feedhorn to separate Nb/SiN/Nb microstrip lines, which are then coupled to Al/Nb lumped-element KIDs (LEKIDs). The silicon on the backside of the OMT is etched away using deep reactive ion etch to release the OMT membrane to enable operation over a wide bandwidth. Finally, the buried oxide is removed underneath the KID capacitors in order to minimize two-level system noise and loss mitigation. We achieved a good yield (> 80%) on our prototype devices.

47 OTHER INSTRUMENTATION↗

Optical Characterization of OMT-Coupled TES Bolometers for LiteBIRD

Feedhorn- and orthomode transducer- (OMT) coupled transition edge sensor (TES) bolometers have been designed and micro-fabricated to meet the optical specifications of the LiteBIRD high frequency telescope (HFT) focal plane. Here, we discuss the design and optical characterization of two LiteBIRD HFT detector types: dual-polarization, dual-frequency-band pixels with 195/280 GHz and 235/337 GHz band centers. Results show well-matched passbands between orthogonal polarization channels and frequency centers within 3% of the design values. The optical efficiency of each frequency channel is conservatively reported to be within the range 0.64–0.72, determined from the response to a cryogenic, temperature-controlled thermal source. These values are in good agreement with expectations and either exceed or are within 10% of the values used in the LiteBIRD sensitivity forecast. Lastly, we report a measurement of loss in Nb/SiN x /Nb microstrip at 100 mK and over the frequency range 200–350 GHz, which is comparable to values previously reported in the literature.

47 OTHER INSTRUMENTATION↗

Kinetic Inductance Traveling Wave Amplifier Designs for Practical Microwave Readout Applications

Abstract A Kinetic Inductance Traveling Wave Amplifier (KIT) utilizes the nonlinear kinetic inductance of superconducting films, particularly niobium titanium nitride (NbTiN), for parametric amplification. These amplifiers achieve remarkable performance in terms of gain, bandwidth, and compression power and frequently approach the quantum limit for noise. However, most KIT demonstrations have been isolated from practical device readout systems. Using a KIT as the first amplifier in the readout chain of an unoptimized microwave SQUID multiplexer coupled to a transition-edge sensor microcalorimeter, we see an initial improvement in the flux noise [1]. One challenge in KIT integration is the considerable microwave pump power required to drive the non-linearity. To address this, we have initiated efforts to reduce the pump power by using thinner NbTiN films and an inverted microstrip transmission line design. In this article, we present the new transmission line design, fabrication procedure, and initial device characterization—including gain and added noise. These devices exhibit over 10 dB of gain with a 3 dB bandwidth of approximately 5.5–7.25 GHz, a maximum practical gain of 12 dB, and typical gain ripple under 4 dB peak to peak. We observe an appreciable impedance mismatch in the NbTiN transmission line, which is likely the source of the majority of the gain ripple. Finally, we perform an initial noise characterization and demonstrate system-added noise of three quanta or less over nearly the entire 3 dB bandwidth.

Physics↗

New Method to Estimate the Permittivity of Dielectric Materials Using MSPS

A new method to estimate the relative dielectric permittivity of material’s sheet is presented. In this method, a conventional microstrip patch sensor (MSPS) is utilized to resonate at 2.45 GHz. An unknown material, considered as a superstrate layer of 5 mm thickness, is located in the near-field region of the MSPS, at a distance of 5 mm above the sensor. From the changes in the MSPS’s parameters, the dielectric property of the unknown material can be deduced. Based on the conformal map theory, theoretical analyses were performed, and hence, simulation analyses were done using the CST-MW software package. This proposed method was validated through measurements. From the theoretical, simulation, and measurement results, it was shown that depending on the frequency response, the relative permittivity can be estimated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Silicon beam telescope for LHC upgrade tests

A beam telescope based on the CMS Tracker data acquisition prototype cards has been developed in order to test sensor candidates for S-LHC tracking systems. The telescope consists of up to eight reference silicon microstrip modules and slots for a couple of test modules. Beam tracks, as measured by the reference modules, provide a means of determining the position resolution and efficiency of the test modules. The impact point precision of reference tracks at the location of the test modules is about 4 {micro}m. This note presents a detailed description of the silicon beam telescope (SiBT) along with some results from its initial operation in summer 2007 in the CERN H2 beamline.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of the CLAS12 Silicon Vertex Tracker modules

For the 12 GeV upgrade, the CLAS12 experiment has designed a Silicon Vertex Tracker (SVT) using single sided microstrip sensors fabricated by Hamamatsu. The sensors have graded angle design to minimize dead areas and a readout pitch of 156{micro}m, with intermediate strip. Double sided SVT module hosts three daisy-chained sensors on each side with a full strip length of 33 cm. There are 512 channels per module read out by four Fermilab Silicon Strip Readout (FSSR2) chips featuring data driven architecture, mounted on a rigid-flex hybrid. Modules are assembled on the barrel using unique cantilevered geometry to minimize the amount of material in the tracking volume. Design and performance of the SVT modules are presented, focusing on results of electrical measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗