Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operational amplifier”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Fluidic analog amplifier

Five-stage, high-gain, push-pull fluidic amplifier provides increased range and improved linearity. The fluidic amplifier was designed to operate in conjunction with a fluidic transducer.

Mc Kenzie, C. P.↗

Brushless DC motor with dual windings

Motor has high starting torque and high running speeds. Control system consists of Hall effect generator/resolver and associated electronic amplifiers and switches. Motor operation is described.

Auclair, G. F.↗

Intermodulation characteristics of X-band IMPATT amplifiers.

Measurement of the intermodulation products produced when two equal amplitude signals are applied to the input of an X-band IMPATT diode amplifier. A Si p(+)nn(+) IMPATT diode was operated in a double-slug-tuned reflection amplifier circuit that was tuned to provide 20 dB of small-signal gain at 9.340 GHz. The intermodulation tests consist of measurements of the magnitudes and frequencies of the amplifier output signals as a function of the input signal drive levels and frequency separations. The gain and single-frequency characteristics of the amplifier were also measured and are used along with the theoretical device and circuit admittance characteristics as a basis for explanation of the intermodulation results. A low-frequency dominance mechanism is found to exist in which the low-frequency signals are amplified more than the high-frequency signals. This mechanism becomes more significant as the amplifier drive level is increased.

Trew, R. J.↗

Simple photometer circuits using modular electronic components

Operational and peak holding amplifiers are discussed as useful circuits for bioluminescence assays. Circuit diagrams are provided. While analog methods can give a good integration on short time scales, digital methods were found best for long term integration in bioluminescence assays. Power supplies, a general photometer circuit with ratio capability, and variations in the basic photometer design are also considered.

Wampler, J. E.↗

Servo Lead Compensation

Circuit for continuously varying lead compensation in servosystem operative even when integrating amplifier goes into saturation.

Buchanan, E.↗

Simulation and analysis of an intermediate frequency (IF) distribution system with applications for Space Station

Simulation and analysis results are described for a wideband fiber optic intermediate frequency distribution channel for a frequency division multiple access (FDMA) system where antenna equipment is remotely located from the signal processing equipment. The fiber optic distribution channel accommodates multiple signals received from a single antenna with differing power levels. Performance parameters addressed are intermodulation degradations, laser noise, and adjacent channel interference, as they impact the overall system design. Simulation results showed that the laser diode modulation level can be allowed to reach 100 percent without considerable degradation. The laser noise must be controlled as to provide a noise floor of less than -90 dBW/Hz. The fiber optic link increases the degradation due to power imbalance yet diminishes the effects of the transmit amplifier nonlinearity. Overall, optimal operation conditions can be found to yield a degradation level of about .1 dB caused by the fiber optic link.

Costello, Thomas A.↗

Low-Noise MMIC Amplifiers for 120 to 180 GHz

Three-stage monolithic millimeter-wave integrated-circuit (MMIC) amplifiers capable of providing useful amounts of gain over the frequency range from 120 to 180 GHz have been developed as prototype low-noise amplifiers (LNAs) to be incorporated into instruments for sensing cosmic microwave background radiation. There are also potential uses for such LNAs in electronic test equipment, passive millimeter- wave imaging systems, radar receivers, communication receivers, and systems for detecting hidden weapons. The main advantage afforded by these MMIC LNAs, relative to prior MMIC LNAs, is that their coverage of the 120-to-180-GHz frequency band makes them suitable for reuse in a wider variety of applications without need to redesign them. Each of these MMIC amplifiers includes InP transistors and coplanar waveguide circuitry on a 50- mthick chip (see Figure 1). Coplanar waveguide transmission lines are used for both applying DC bias and matching of input and output impedances of each transistor stage. Via holes are incorporated between top and bottom ground planes to suppress propagation of electromagnetic modes in the substrate. On the basis of computational simulations, each of these amplifiers was expected to operate with a small-signal gain of 14 dB and a noise figure of 4.3 dB. At the time of writing this article, measurements of noise figures had not been reported, but on-chip measurements had shown gains approaching their simulated values (see Figure 2).

Pukala, David↗

AD8065 Voltage Feedback Amplifier’s Total Ionizing Dose Characterization Report

The purpose of this testing was to characterize Analog Devices’ AD8065 FastFET amplifier for low-dose rate (LDR) total ionizing dose (TID) response based on the Lucy project requirements and will be used on the L’ORRI instrument being built by Johns Hopkins University Applied Physics Lab. The AD8065 is a voltage feedback amplifier with FET inputs developed with the proprietary eXtra Fast Complementary Bipolar (XFCB) process. The amplifier boasts low noise operation and very high input impedance with a wide supply voltage range.

Megan Casey↗

Analysis of a Novel Diffractive Scanning Wire Beam Position Monitor (BPM) for Discriminative Profiling of Electron Vs. X Ray Beams

Recent numerical studies of Free Electron Lasers (FELs) operating in the Self Amplified Spontaneous Emission (SASE) regime indicate a large sensitivity of the gain to the degree of transverse overlap (and associated phase coherence) between the electron and photon beams traveling down the insertion device. Simulations of actual systems imply that accurate detection and correction for this relative loss of overlap, rather than correction for the absolute departure of the electron beam from a fixed axis, is the preferred function of an FEL amplifier's Beam Position Monitor (BPM) and corrector systems. In this note we propose a novel diffractive BPM with the capability of simultaneously detecting and resolving the absolute (and relative) transverse positions and profiles of electron and x-ray beams co-propagating through an undulator. We derive the equations governing the performance of the BPM and examine its predicted performance for the SLAC Linac Coherent Light Source (LCLS), viz., for profiling multi-GeV electron bunches co-propagating with one-to-several-hundred keV x-ray beams. Selected research and development (r&d) tasks for fabricating and testing the proposed BPM are discussed.

43 PARTICLE ACCELERATORS↗

Feedback Requirements for SASE-FELs

The operation of a Self Amplified Spontaneous Emission (SASE) Free Electron Lasers (FEL) at soft and hard X-ray wavelengths driven by a high brightness electron beam imposes strong requirements on the stability of the accelerator and feedback systems are necessary to both guarantee saturation of the SASE process as well as a stable photon beam for user experiments. Diagnostics for the relevant transverse and longitudinal beam parameters are presented and various examples of feedback systems for bunches with low repetition rate as well as systems for intra bunch train feedbacks are discussed.

43 PARTICLE ACCELERATORS↗

Development of high frequency and wide bandwidth Johnson noise thermometry

We develop a high frequency, wide bandwidth radiometer operating at room temperature, which augments the traditional technique of Johnson noise thermometry for nanoscale thermal transport studies. Employing low noise amplifiers and an analog multiplier operating at 2 GHz, auto- and cross-correlated Johnson noise measurements are performed in the temperature range of 3 to 300 K, achieving a sensitivity of 5.5 mK (110 ppm) in 1 s of integration time. This setup allows us to measure the thermal conductance of a boron nitride encapsulated monolayer graphene device over a wide temperature range. Our data show a high power law (T ∼ 4) deviation from the Wiedemann-Franz law above T ∼ 100 K.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Use of a Solid State Analog Television Transmitter as a Superconducting Electron Gun Power Amplifier

A solid state analog television transmitter designed for 200 MHz operation is being commissioned as a radio frequency power amplifier on the Wisconsin superconducting electron gun cavity. The amplifier consists of three separate radio frequency power combiner cabinets and one monitor and control cabinet. The transmitter employs rugged field effect transistors built into one kilowatt drawers that are individually hot swappable at maximum continuous power output. The total combined power of the transmitter system is 33 kW at 200 MHz, output through a standard coaxial transmission line. A low level radio frequency system is employed to digitally synthesize the 200 MHz signal and precisely control amplitude and phase.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High gain and wideband hybrid optical amplifier using bismuth-doped and neodymium-doped fibers for E-band applications

A hybrid dual-stage bismuth-doped fiber and neodymium-doped fiber amplifier with high optical gain and extended bandwidth of operation in the E-band is demonstrated. The amplifier features a maximum gain of 43 dB, output power of 372 mW, and a minimum noise figure of 5.5 dB, and operation wavelength range of 1397–1472 nm, enabled by 153-m of bismuth-doped fiber and two 7-m lengths of neodymium-doped fiber. The demonstration shows the possibility of achieving improved gain bandwidth by combining fiber amplifiers with overlapping gain spectra in the E-band.

Applied optics↗

A Low Cost SIPM Evaluation and Control Prototyping System including accurate bias voltage generation, leakage current measurement, and temperature control using Peltier cooling

We describe an electronics system to operate SIPMs in the laboratory. The system is comprised of a single channel amplifier board (SIPM Amp) and a 4-channel control board to which up to 4 SIPM Amp boards can be connected. The control board supplies a common low voltage power for the amplifiers. All channels feature individually regulated bias and Peltier power voltages, along withPt10K RTD readout. A graphical user interface allows control of the bias voltages, amplifier voltage, Peltier voltages, and also provides for readback of leakage currents and other voltages. The GUI app has a feedback loop to measure the SIPM temperature (with the PT10K) and generate correction voltages to the Peltier to regulate the temperature. The temperatures, which can be achieved by Peltier cooling depend on the thermal design of the setup, the practical limit being about 50C below ambient. The SIPM Amp. board is a small (3x5cm) PCB that has a single SIPM readout channel. The SIPM scan be surface mounted on the pcb or connected to a 2-pin 0.100" socket. The area around the SIPM footprint is thermally isolated by perforations in the PCB. The RTD is located inside the thermal break. Onboard is BV and LV filtering. The 10X amplifier is based on MiniCircuits' GALI-S66+ integrated circuit, tweaked for a 6V power. The amplifier was selected for a combination of high bandwidth, low noise, and low power. An accoupled amplifier output is connected to an SMA connector. For best operation of this inverting amplifier the output signal should be in the range of 0 to -1V.The Amplifier board is connected to the Control board with a 10-conductor 0.025" pitch ribbon cable, carrying all the services. Peltier power for currents more than 1A should use a separate 2-contact connector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scaling high-energy pulsed solid-state lasers to high average power

Techniques are provided for scaling the average power of high-energy solid-state lasers to high values of average output power while maintaining high efficiency. An exemplary technique combines a gas-cooled-slab amplifier architecture with a pattern of amplifier pumping and extraction in which pumping is continuous and in which only a small fraction of the energy stored in the amplifier is extracted on any one pulse. Efficient operation is achieved by propagating many pulses through the amplifier during each period equal to the fluorescence decay time of the gain medium, so that the preponderance of the energy cycled through the upper laser level decays through extraction by the amplified pulses rather than through fluorescence decay.

Erlandson, Alvin C.↗

Geometric invariants of quantum metrology

Here, we establish a conservation law for the Quantum Fisher Information Matrix (QFIM) expressed as follows; when the QFIM is constructed from a set of observables closed under commutation, i.e., a Lie algebra, the spectrum of the QFIM is invariant under unitary dynamics generated by these same operators. Each Lie algebra therefore endows any quantum state with a fixed “budget” of metrological sensitivity—an intrinsic resource that we show, like optical squeezing in interferometry, cannot be amplified by symmetry-preserving operations. The Uhlmann curvature tensor naturally inherits the same symmetry group, and so quantum incompatibility is similarly fixed. As a result, a metrological analog to Liouville's theorem appears; statistical distances, volumes, and curvatures are invariant under the evolution generated by the Lie algebra. We discuss this as it relates to the quantum analogs of classical optimality criteria. This enables one to efficiently classify useful classes of quantum states at the level of Lie algebras through geometric invariants.

Wilson, Christopher [University of Colorado, Bould↗

Particle simulation of a ka-band gyrotron traveling wave amplifier

The design of a ka-band gyrotron traveling wave (gyro-TWT) amplifier is presented. The gyro-TWT amplifier with a severed structure operates in the fundamental harmonic TE{sub 01} circular electric mode. The beam-wave interaction is studied by using a particle-in-cell (PIC) code. The simulations predict that the amplifier can produce an output peak power of over 155 kW, 22% efficiency, 23 dB gain, and a 3 dB bandwidth of 2 GHz for a 70 kV, 10 A electron beam with an axial velocity spread {Delta}v{sub z}/v{sub z}=5%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗