Search NASA⌕ Search

SEARCH · Search NASA

Results for “POLISHING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Exploring a quantum-information-relevant magnonic material: Ultralow damping at low temperature in the organic ferrimagnet V[TCNE]x

Quantum information science and engineering require novel low-loss magnetic materials for magnon-based quantum-coherent operations. The search for low-loss magnetic materials, traditionally driven by applications in microwave electronics near room temperature, has gained additional constraints from the need to operate at cryogenic temperatures for many applications in quantum information science and technology. Whereas yttrium iron garnet (YIG) has been the material of choice for decades, the emergence of molecule-based materials with robust magnetism and ultra-low damping has opened new avenues for exploration. Specifically, thin films of vanadium tetracyanoethylene (V[TCNE]x) can be patterned into the multiple, connected structures needed for hybrid quantum elements and have shown room-temperature Gilbert damping (α = 4 × 10−5) that rivals the intrinsic (bulk) damping otherwise seen only in highly polished YIG spheres (far more challenging to integrate into arrays). Here, the authors present a comprehensive and systematic study of the low-temperature magnetization dynamics for V[TCNE]x thin films, with implications for their application in quantum systems. These studies reveal a temperature-driven, strain-dependent magnetic anisotropy that compensates the thin-film shape anisotropy and the recovery of a magnetic resonance linewidth at 5 K that is comparable to room-temperature values (roughly 2 G at 9.4 GHz). The authors can account for these variations of the V[TCNE]x linewidth within the context of scattering from very dilute paramagnetic impurities and anticipate additional linewidth narrowing as the temperature is further reduced.

Yusuf, H. (ORCID:0000000194627928)↗

Molybdenum and silver photoemission survey spectra from hard x-rays

Electron emission from thick polished samples of polycrystalline molybdenum (Mo) and single crystalline $\langle$111$\rangle$ silver (Ag) was measured with hard x-ray photoemission spectroscopy. Six different excitation x-ray energies were used, nominally 8.0, 11.0, 13.0, 15.0, 18.0, and 21.5 keV. Survey spectra were recorded with each excitation to a kinetic energy of at most 15 keV, often capturing the entire emission range. The Mo 1s core peak was measured. Detailed LMM Auger spectra of Mo show marked increases in intensity and altered shape when x-ray energy exceeds the Mo 1s binding energy. The Mo and Ag L-shell photoelectron peaks are measured at four x-ray energies up to 18 keV showing the transition from 2p3/2 to 2s photoionization dominance.

47 OTHER INSTRUMENTATION↗

Vapor phase deposition of alumina on interior surfaces of tritium storage containers

Efficient tritium management and containment are critical challenges for nuclear fusion. To mitigate issues related to permeation into structural materials and isotopic exchange with protium, permeation barriers must be applied to the nonplanar internal surfaces of tritium handling components. In this study, we developed an atomic layer deposition (ALD) system to deposit films on canisters used to store and transport tritium. Growth conditions for deposition of Al 2 O 3 were mapped spatially along the length of a canister using silicon witness samples characterized by ellipsometry, atomic force microscopy, and x-ray reflectivity (XRR). We identified ALD process windows for growth at temperatures between 100 and 140 °C. Furthermore, we compared films grown on our Si witness samples to those grown on polished stainless steel 316 (SS316). X-ray photoelectron spectroscopy indicates two distinct chemical states for the alumina, while XRR confirms that the overall growth rate is similar to the 1.1 Å/cycle that we observed on the Si witness samples.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analytical expressions of the surface shape of ‘diaboloid’ mirrors

Modern deterministic polishing processes allow fabrication of x-ray optics with almost any arbitrary aspherical surface shape. Among these optics, the so called "diaboloid"mirror is of special interest. The diaboloid mirror that converts a cylindrical wave to a spherical wave would improve focusing in x-ray beamlines implementing a diffraction element between a parabolic cylinder and a toroidal mirror. The replacement of the toroidal mirror in existing beamlines by the diaboloid mirror would mitigate aberrations. The shape of the diaboloid mirror is usually calculated numerically based on a truncated polynomial solution of the optical path problem. Here, we present an exact analytical solution for the shape of a diaboloid mirror as a function of the conjugate parameters of the mirror placed in a beamline. The derived analytical expressions for the diaboloid mirror in both the canonical and mirror-based coordinate systems are implemented in ray-tracing simulations to verify the beamline performances.

Yashchuk, Valeriy V.↗

Determining Infrared Optical Constants for Dolomite using Single Angle Reflectance and Spectroscopic Ellipsometry

The optical constants, namely the real (n) and imaginary (k) parts of the complex refractive index, are of particular interest to generate the infrared (IR) spectra of liquid and solid materials in different morphologies. To obtain n/k, however, most materials are typically not found in the monolithic forms necessary to easily measure n/k, and thus require the use of other methods such as pressing powders to form planar, specularly-reflective pellets. In this work dolomite crystals are measured using fixed-angle IR reflectance spectroscopy in both 1) a monolithic form with the crystal fixed in epoxy and polished, but data are also recorded from 2) pressed-pellet forms of powders of the same mineral using the same spectroscopic protocols. First results for the two methods are compared. It was found that the measured reflectance can vary by as much as a factor of two between the dolomite crystals and the pressed powder forms. For the two-sample preparation approaches the preliminary spectra are compared and the implications and limitations of each method for determining the optical constants of given materials are discussed. Comparison to literature data suggest that polarization effects likely account for the differing amplitude results for reflectance (and hence the k -vectors): Dolomite is known to be biaxial with significantly differing ordinary and extraordinary rays; the pressed pellet method measures an ensemble of microcrystals in randomly oriented positions, whereas the single crystal maintains just one orientation relative to the optical axis.

ellipsometry, dolomite, complex refractive index, ↗

Binary pseudo-random array standards for calibration of 3D optical surface profilers used for metrology with aspheric x-ray optics

High-accuracy surface metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate x-ray light with nanometer-scale wavelengths. The current and potential capabilities of x˗ray mirror manufacturing are limited by inherent imperfections of the integrated metrology tools. Metrology tools are currently calibrated with super-polished flat test-standard/reference mirrors. This is acceptable for fabrication of slightly curved x-ray optics. However, for even moderately curved aspherical x-ray mirrors the flat-reference calibration is not sufficiently accurate. For micro-stitching interferometry developed for surface measurements with curved x-ray mirrors, the tool aberration errors are known to be transferred into the optical surface topography of x-ray mirrors. Our approach to improving metrology is to thoroughly calibrate the measuring tool and apply the results of the calibration to deconvolution of the measured data. Here we explore the application of a recently developed technique for calibrating the instrument transfer function (ITF) of 3D optical surface profilers to metrology with significantly curved x-ray optics. The technique, based on test standards patterned with two-dimensional (2D) binary pseudo-random arrays (BPRAs), employs the unique properties of the BPRA patterns in the spatial frequency domain. The inherent 2D power spectral density of the pattern has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range and field of view of an instrument. The high efficacy of the technique has been previously demonstrated in application to metrology with flat and slightly curved optics. Here, we concentrate on development of an efficient fabrication process for production of highly randomized (HR) BPRA test standards on flat and 500-mm spherical optical substrates. We also compare and discuss the results of the ITF calibration of an interferometric microscope when using the HR BPRA standards on flat and curved substrates.

Munechika, Keiko↗

Preshaping clear glass at low temperatures

Advances in available glass chemistries and glass processing methods have accompanied and enabled some of the biggest technology revolutions, from the development and mass production of light bulbs to low-loss fiber optics and durable smartphone touchscreens. An emerging generation of low-temperature processing technologies aims to continue this important trend and make a broader array of glass components mass producible. In the issue, Mader et al. (1) describe one such innovation in glass processing—the use of low-temperature injection molding to preshape silica particle–filled composites that can later be transformed into transparent fused silica glass objects. Traditionally, transparent glass objects are manufactured in high volume from molten or softened glass, which is floated, drawn, blown, cast, or blow-molded to a desired shape (see the figure, top). The glass composition and processing technique dictate the working temperature, which is usually quite high (near 1000°C) and often restricts the choice of compatible equipment or limits the choice of glass composition. Because geometry-specific capital investment is required for production, drastic or frequent component design changes or small batches may be cost prohibitive. Alternatively, transparent glass components can also be shaped at ambient temperature from solid glass by a series of subtractive processes, including cutting or multiple stages of grinding, followed by slower processing steps, such as polishing or etching. This approach is somewhat less amenable to mass production, and certain geometries containing tool-inaccessible regions cannot be fabricated in this way. Several emerging glass-shaping technologies aim to reduce the required manufacturing temperatures and still provide access to a broader range of glass compositions and component geometries (see the figure). These approaches use a three-step process. First, a desired shape is preformed at low temperature from a glass-forming, organic-inorganic composite. Next, the preform is dried, and organic materials used to bind particles are removed. Finally, the preform is heated (sintered) well below the glass-melting temperature to densify to transparent glass. Although the second and third steps do occur at increased temperatures, only standard, geometry-agnostic driers and furnaces are required. This strategy builds on the well-studied sol-gel approach to forming monolithic glass, where silica network–forming chemical solutions are poured into molds, slowly dried, and condensed into dense glass without melting (2). In a departure from the sol-gel process, these new technologies use solvents, cross-linkers, and polymers to formulate organic-inorganic composites tuned for compatibility with a particular shaping process, with formats ranging from photocurable liquids to shear-thickening pastes to solids. The composite inorganic loadings are also typically higher than those in the pure sol-gel approach, which drastically reduces shrinkage in comparison.

36 MATERIALS SCIENCE↗

The Effect of Sulfuric Acid Anodization on the Electrochemical Properties of Aluminum Alloy AlSi 10 Mg Prepared by Selective Laser Melting

Aluminum alloy, AlSi 10 Mg, prepared by selective laser melt (SLM) fabrication was anodized in 9.8% sulfuric acid (Type II) at 15 V for a total of 23 min. Experiments were performed to study the potentiostatic anodization process and its effects on the oxide coating morphology, thickness, and electrochemical properties of the alloy. Prior to anodization, the alloy microstructure is composed of aluminum cells encapsulated in a silicon network. Anodizing the abraded and polished AlSi 10 Mg surface produced a porous oxide layer with a thickness of 5μm. The oxide coating weight was 698 ± 29 mg/ft 2 . The oxide coating forms in the aluminum cells that are isolated from one another by the silicon eutectic phase. In electrochemical tests, the anodic and cathodic potentiodynamic polarization currents were suppressed by factors of 15× and 215×, respectively, as compared to the unanodized controls. The data indicate the anodic oxide coating suppresses the cathodic more than the anodic reaction rate. Linear polarization resistance (R p ) values increased by 279× after anodization. The corrosion current density values (j corr ) decreased by 133× after anodization. Taken together, the electrochemical data indicate the anodic oxide coating (unsealed) increases the corrosion resistance of the SLM alloy by two orders of magnitude.

Electrochemistry↗

Improved Infrared Optical Constants from Pressed Pellets: II. Ellipsometric n and k Values for Ammonium Sulfate with Variability Analysis

Infrared spectral imaging is facilitated via the comparison of spectra recorded in situ to a databank of actual or synthetic infrared reflectance spectra. It has recently been shown that reference spectra corresponding to the many different morphological forms of the same chemical can be generated synthetically using the imaginary, k, and real, n, components of the complex refractive index, n~ = n + ik. One method to obtain the n and k vectors is infrared ellipsometry, which measures the changes in amplitude, tan ?, and phase, ?, of polarized light reflected from the sample both as a function of wavenumber and angle of incidence. The method requires specularly reflected light so best results are usually obtained with polished planar samples of large surface area. Due to the difficulties of obtaining such samples, however, we investigate the possibility of pressing powders of neat materials and obtaining the corresponding optical constants from the pellets. In this paper, variability in the sample pellet and preparation method is investigated, as is variability in the fitting procedure for the derived optical constants. The n/k vectors are derived from the measured ellipsometric parameters, tan ? and ?, as they are fit by an oscillator model which yield n(?) and k(?) vectors as a function of wavenumber, ?. Construction of the oscillator model is not automatic and depends on significant input from the analyst as well as the sample’s physical characteristics. For the pellet pressing, the experimental variability was found to be minimized for size-selected powdered samples as gauged by the minimal variance in ? and ? for three different pellets; similarly, the analytical precision for multiple measurements of the same pellet was also quite good, suggesting that a pressed pellet is a viable sample preparation method. The greatest variability came in the analytic fitting procedure with differences up to 20% arising from four different fits to the same data set. The final ellipsometric n/k data are compared to literature values obtained from crystalline (NH4)2SO4 samples as well as single-angle reflectance measurements that also used pressed pellets. Comparison with the previous literature values shows generally good agreement although higher k-values are observed for the independent sets of data derived from pressed pellets. These data are suggested as an improved set of optical constants for (NH4)2SO4.

optical constants, ellipsometry, ammonium sulfate,↗

Sapphire advanced mitigation process: wet etch to expose sub-surface damage and increase laser damage resistance and mechanical strength

In this study, a novel, to the best of our knowledge, method of wet chemical etching of sapphire workpieces (such as optics, wafers, windows, and cones), called the sapphire advanced mitigation process (or sapphire AMP), has been developed that exposes sub-surface mechanical damage created during the optical fabrication process and significantly enhances the surface laser damage resistance (> 2×) and mechanical strength (up to ~ 2.6×). Sapphire AMP involves first treating the workpiece with a mixture of sulfuric and phosphoric acid ([H 2 SO 4 ]:[H 3 PO 4 ]= 1 : 3) at 220°C, followed with phosphoric acid at 160°C, then with sodium hydroxide base (NaOH) and surfactant at 40°C, and finally with a high-pressure deionized water spray rinse. Sapphire AMP has been demonstrated on both A- and C-plane sapphire workpieces. The mechanism of this etch process involves the reaction of the sapphire (Al 2 O 3 ) surface with sulfuric acid (H 2 SO 4 ) forming aluminum sulfate [Al2(SO4)3], which has low solubility. The high phosphoric acid content in the first and second steps of sapphire AMP results in the efficient conversion of Al 2 (SO 4 ) 3 to aluminum phosphate (AlPO 4 ), which is very soluble, greatly reducing reaction product redeposition on the workpiece surface. Sapphire AMP is shown to expose sub-surface mechanical damage on the sapphire surface created during the grinding and polishing processes, whose etched morphology has either isotropic or anisotropic evolution depending on the nature of the initial surface damage. Sapphire AMP was also designed to remove the key known surface, laser absorbing precursors (namely, foreign chemical impurities, the fracture surface layer of preexisting sub-surface damage, and reaction product or foreign species redeposition or precipitation). Static and sliding indention induced surface microfractures on sapphire are shown after sapphire AMP to have a significant decrease in the fast photoluminescence intensity (a known metric for measuring the degree of laser damaging absorbing precursors). In addition, the onset of laser damage (at 351 nm 3 ns) on sapphire AMP treated workpieces was shown to increase in fluence from ~ 4 to >9.5J/cm 2 . Finally, biaxial ball-on-ring mechanical tests on sapphire disks showed an increase in the failure stress from 340 MPa (with pre-existing 28 µm flaws) to ~ 900MPa after sapphire AMP, which is attributed to the blunting of the surface microfractures.

36 MATERIALS SCIENCE↗

Enhanced laser-induced damage performance of all-glass metasurfaces for energetic pulsed laser applications

To fabricate optical components with surface layers compatible with high power laser applications that may operate as antireflective coatings, polarization rotators, or harness physical anisotropy for other uses, metasurfaces are becoming an appealing candidate. In this study, a large-beam (1.05 cm diameter) 351-nm laser-induced damage testing was done on an all-glass metasurface structure composed of cone-like features with a subwavelength spacing of adjacent features. These structures were fabricated on untreated fused silica glass and damage tested, as were structures that were fabricated on fused silica glass that experienced a preliminary etching process to remove the surface Beilby layer that is characteristic of polished fused silica. The laser-induced damage onset for structures on untreated fused silica glass was 19.3 J∙cm -2 , while the sample that saw an initial pretreatment etch exhibited an improved damage onset of 20.4 J∙cm -2 , only 6% short of the reference pretreated glass damage onset of 21.7 J∙cm -2 . For perspective, the National Ignition Facility (NIF) operational average fluence at this wavelength and pulse length is about 10 J/cm2. At a fluence of 25.5 J∙cm -2 , the reference (pretreated) fused silica initiated 5.2 damage sites per mm 2 , while the antireflective metasurface sample with a preliminary etching process treatment initiated 9.8 damage sites per mm 2 . In conclusion, these findings demonstrate that substrate-engraved metasurfaces are compatible with high energy and power laser applications, further broadening their application space.

36 MATERIALS SCIENCE↗

Temporal contrast degradation from mid-spatial-frequency surface error on stretcher mirrors

Temporal contrast degradation due to mid-spatial-frequency error in chirped-pulse amplification stretcher optics is studied. Third-order cross-correlation measurements reveal a temporal peak that appears when using two different mirrors processed by magnetorheological finishing, despite an improvement in rms roughness compared to a third unprocessed mirror. Simulations based on measured power spectral density show how the actual impact on contrast is different from measurements using a typical bandwidth-limited third-order cross correlator. Furthermore, strategies are proposed to avoid this type of contrast degradation while exploiting computer numerically controlled polishing techniques for enhancement of surface figure and roughness.

47 OTHER INSTRUMENTATION↗

Subsurface mechanical damage of fused silica glass during grinding by various sub-aperture tools with and without ultrasonics

The subsurface mechanical damage (SSD) depth after grinding fused silica glass with a comprehensive set of sub-aperture fixed abrasive grinding tools [cup, wheel, belt, pad, and rotary face mill (with and without ultrasonics)] and process parameters has been statistically measured using the taper wedge technique and evaluated. Consistent with a previously reported grinding model [J. Non-Cryst. Solids 352, 5601–5617 (2006) Crossref , Materials Science and Technology of Optical Fabrication (Wiley & Sons, 2018)], based on the sliding indentation fracture by sliding particles or asperities where the normal load per particle determines the depth of the fracture (and ultimately the overall SSD depth), the dominant factor controlling SSD depth was found to be the abrasive size regardless of the tool type and process conditions. Compared to full aperture grinding methods, the overall SSD depth was higher using the sub-aperture tools, likely due to the higher effective pressure and higher load per particle distribution. Here, in addition to abrasive size, a significant reduction in SSD depth was achieved by: (1) reducing the load distribution on the abrasive particles via increase in contact area and/or decrease in mechanical loading; (2) using a more compliant host tool medium; and (3) in what we believe is a more novel way, using ultrasonics. Combining low abrasive size, larger contact area, and a compliant host, the 6 µm diamond in a resin matrix (Trizact) on a foam pad led to very low SSD depth (~ 4.6 µm), relatively fast grinding rate (186 mm 3 /h), and little or no figure degradation. This grinding tool/process is an attractive choice for final grind, resulting in significantly reduced polish out (i.e., “grey out”) times. With the rotary face mill tool, the use of ultrasonics consistently led to a SSD depth reduction (ranging from 17%–34%). A new fracture mechanics-based model, to the best of our knowledge, where the relevant normal load is parallel to the feed direction, has been developed to explain how ultrasonics leads to lower SSD depth. The key factors, supported by finite element stress analysis and load measurements, are (1) the initiation of fractures at higher z heights during the tool’s ultrasonic vertical oscillations, thus propagating less deep into workpiece; (2) reduction in load (and therefore reduction in fracture propagation distance) due to smaller tool-workpiece feed direction contact area (again caused by higher heights relative to depth of cut); (3) upward movement of the tool during oscillation leads to fracturing toward the surface instead into the depth; and finally (4) at tool’s lowest point of oscillation cycle, there may not be enough time for the fracture to propagate to its full length.

Optics and optical instruments↗

Micro-fabricated mirrors with finesse exceeding one million

The Fabry–Perot resonator is one of the most widely used optical devices, enabling scientific and technological breakthroughs in diverse fields including cavity quantum electrodynamics, optical clocks, precision length metrology, and spectroscopy. Though resonator designs vary widely, all high-end applications benefit from mirrors with the lowest loss and highest finesse possible. Fabrication of the highest-finesse mirrors relies on centuries-old mechanical polishing techniques, which offer losses at the parts-per-million (ppm) level. However, no existing fabrication techniques are able to produce high-finesse resonators with the large range of mirror geometries needed for scalable quantum devices and next-generation compact atomic clocks. In this paper, we introduce a scalable approach to fabricate mirrors with ultrahigh finesse ( ≥ <#comment/> 10 6 ) and user-defined radius of curvature spanning of four orders of magnitude ( 10 − <#comment/> 4 − <#comment/> 10 0 m ). We employ photoresist reflow and reactive ion etching to shape and transfer mirror templates onto a substrate while maintaining sub-Angstrom roughness. This substrate is coated with a dielectric stack and used to create arrays of compact Fabry–Perot resonators with finesse values as high as 1.3 million and measured excess loss < <#comment/> 1 p p m . Optical ringdown measurements of 43 devices across five substrates reveal that the fabricated cavity mirrors—with both small and large radii of curvature—produce an average coating-limited finesse of 1.05 million. This versatile approach opens the door to scalable fabrication of high-finesse miniaturized Fabry–Perot cavities needed for emerging quantum optics and frequency metrology technologies.

42 ENGINEERING↗

High finesse buckled microcavities

Optical cavities are widely used in modern science and technology to enable a wide range of both quantum and classical applications. Recently, the growing demand for miniaturization and high performance has fueled the exploration of new fabrication methods beyond traditional polishing techniques and macroscopic mirrors. Visible and near-infrared (NIR) wavelengths are particularly important for quantum applications, where achieving low-loss resonators is also more challenging than in the telecom range, presenting unique challenges and opportunities for microscopic cavity systems. Here, we present a fabrication method for making NIR microcavities using buckled dielectric membrane mirrors, achieving a record finesse of 0.9 million at 780 nm for microcavities. We demonstrated flexible device geometries—including singular mirrors and mirror arrays, featuring radii of curvature ranging from 1 to 10 mm. The fabrication process offers high uniformity, high yield, and robust performance across a wide range of cavity lengths. Additionally, we can produce easy-to-assemble microcavity packages, with a total volume of ~2(4) mm 3 , featuring optical modes with a linewidth of 5.16 MHz (570 kHz) and a free spectral range (FSR) of 3.18 THz (150 GHz). Our results extend the frontier of microcavity fabrication for classical and quantum photonic technologies.

Ding, Sophie Weiyi [Harvard Univ., Cambridge, MA (↗

Scalable low-loss cryogenic packaging of quantum memories in CMOS-foundry processed photonic chips

Optically linked solid-state quantum memories such as color centers in diamond are a promising platform for distributed quantum information processing and networking. Photonic integrated circuits (PICs) have emerged as a crucial enabling technology for these systems, integrating quantum memories with efficient electrical and optical interfaces in a compact and scalable platform. Packaging these hybrid chips into deployable modules while maintaining low optical loss and resiliency to temperature cycling is a central challenge to their practical use. We demonstrate a packaging method for PICs using surface grating couplers and angle-polished fiber arrays that is robust to temperature cycling, offers scalable channel count, applies to a wide variety of PIC platforms and wavelengths, and offers pathways to automated high-throughput packaging. Using this method, we show optically and electrically packaged quantum memory modules integrating all required qubit controls on chip, operating at millikelvin temperatures with <3 dB losses achievable from fiber to quantum memory for the TE 0 mode at a wavelength of 737 nm.

Bernson, Robert [Tyndall National Institute, Cork ↗

COMMISSIONING RESULTS OF THIRD C75 CRYOMODULE FOR CEBAF

The program to upgrade CEBAF cryomodules has been implemented to enhance the energy gain of refur-bished cryomodules up to 75 MeV. This strategy in-volves reusing the waveguide end-groups from original CEBAF cavities produced in the 1990s, and existing five elliptical cell cavities are replaced with a new optimized cell shape cavity constructed from large-grain, ingot Nb material. Following fabrication, each cavity undergoes centrifugal barrel polishing and electropolishing and is tested at 2.07 K. Eight cavities are then assembled into "cavity pairs" and tested at 2.07 K before integration into the cryomodule. This paper pre-sents the outcomes of the cavity qualification for the third C75 module, providing a detailed account of the assessment in both a vertical cryostat and the acceptance test results of the cryomodule. Furthermore, efforts have been made to address performance limitations arising from field emission and multipacting

Senevirathne, I.↗

Evaluation of Single-Cell Cavities Made of Forged Ingot Niobium at Jefferson Lab

Currently, fine grain niobium (Nb) (grain size ~ 50 um) and large grain Nb (grain size of a few cm) are being used for the fabrication of superconducting radio frequency (SRF) cavities. Medium grain forged ingot with grain size of a few hundred um may be beneficial for cost-effectiveness as well as providing better performance for future SRF-based accelerators. Forged ingot Nb with medium grain size is a novel production method to obtain Nb discs used for the fabrication of superconducting radio frequency cavities. We have fabricated two 1.5 GHz single cell cavities made from forged Nb ingot with a residual resistivity ratio of ~100. The cavities were chemically and mechanically polished and heat-treated in the temperature range of 650-1000 C before the rf test. One of the cavities reached an accelerating gradient of 34 MV/m with a quality factor Q > 1e10, while the second cavity was limited at 14 MV/m, likely due to a weld defect at the equator.

Dhakal, P.↗