DOE OSTI · 2367526
COMMISSIONING RESULTS OF THIRD C75 CRYOMODULE FOR CEBAF
Abstract
The program to upgrade CEBAF cryomodules has been implemented to enhance the energy gain of refur-bished cryomodules up to 75 MeV. This strategy in-volves reusing the waveguide end-groups from original CEBAF cavities produced in the 1990s, and existing five elliptical cell cavities are replaced with a new optimized cell shape cavity constructed from large-grain, ingot Nb material. Following fabrication, each cavity undergoes centrifugal barrel polishing and electropolishing and is tested at 2.07 K. Eight cavities are then assembled into "cavity pairs" and tested at 2.07 K before integration into the cryomodule. This paper pre-sents the outcomes of the cavity qualification for the third C75 module, providing a detailed account of the assessment in both a vertical cryostat and the acceptance test results of the cryomodule. Furthermore, efforts have been made to address performance limitations arising from field emission and multipacting
Keep this discovery
Explore connections, maps & timelines
Senevirathne, I., Cheng, G., McCaughan, M., Drury, M., Ciovati, G., Weaks, M.. 2024-05-01. COMMISSIONING RESULTS OF THIRD C75 CRYOMODULE FOR CEBAF. https://doi.org/10.18429/jacow-ipac2024-mopc55
Cite the original work for its findings. Save a collection to share your selection of sources.