Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Self-Assembled Vesicles from Mixed Brush Nanoparticles in Solution

The self-assembly of binary polymer-grafted nanoparticles (NPs) in a selective solvent is investigated using coarse-grained simulations. Simulations are performed using theoretically informed Langevin dynamics (TILD), a particle-based method that employs a particle-to-mesh scheme to efficiently calculate the nonbonded interactions. Here, the particles are densely grafted with two immiscible polymers, A and B, that are permanently bound to the NP either at random grafting sites (random-grafted) or with all the A chains on one hemisphere of the NP and all the B chains on the other hemisphere (Janus-grafted). For NPs with random grafting, the polymers phase-separate on the surface of the NP to form Janus-type structures in dilute solution, even though some of the chains have to stretch around the particle to form the Janus structure. When the solvent quality is sufficiently poor for the solvophobic chains, the binary grafted NPs assemble into various structures, including double-walled vesicles. In particular, vesicles are formed when the solvophilic volume fraction is between 0.2 and 0.3, in a similar range to that required for vesicle formation in diblock copolymers in a selective solvent. For mixed-grafted NPs, there is considerable variation in the structure of each individual NP, but nevertheless, these NPs form ordered vesicles, similar to those formed by Janus-grafted NPs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Resolving cosmic neutrino structure: a hybrid neutrino N-body scheme

We present the first simulation capable of resolving the structure of neutrino clustering on Mpc scales. The method combines grid- and particle-based methods and achieves very good accuracy on both small and large scales, while keeping CPU consumption under control. Such simulations are not only ideal for calculating the non-linear matter power spectrum but also particularly relevant for studies of how neutrinos cluster in galaxy- or cluster-sized halos. We perform the largest neutrino N-body simulation to date, effectively containing 10 different neutrino hot dark matter components with different thermal properties.

79 ASTRONOMY AND ASTROPHYSICS↗

CryoTransformer: a transformer model for picking protein particles from Cryo-EM micrographs

Cryo-electron microscopy (cryo-EM) is a powerful technique for determining the structures of large protein complexes. Picking single protein particles from cryo-EM micrographs (images) is a crucial step in reconstructing protein structures from them. However, the widely used template-based particle picking process requires some manual particle picking and is labor-intensive and time-consuming. Though machine learning and artificial intelligence (AI) can potentially automate particle picking, the current AI methods pick particles with low precision or low recall. The erroneously picked particles can severely reduce the quality of reconstructed protein structures, especially for the micrographs with low signal-to-noise-ratio (SNR).

59 BASIC BIOLOGICAL SCIENCES↗

UN-SiC TRISO Post Irradiation Examination Developmental Work

As part of efforts to strengthen INL?s post irradiation analysis capabilities with non-Advanced Gas Reactor (AGR) tristructural isotropic (TRISO) fuels, two developmental activities were conducted. The first activity was to determine how best to analyze uranium nitride TRISO fuel kernels using electron probe microanalysis, while the second activity focused on developing a method to deconsolidate TRISO fuel particles that have been encased in a silicon carbide matrix. Because these two activities were unrelated, they have been presented separately in this report. Initial EPMA analyses showed nitrogen contents that far exceeded the concentration expected for UN--a line compound. Further examination showed that current literature values for the mass absorption coefficient (MAC) for the N ka X-ray absorbed by U ranged from approximately 1600 to 9500, with most values tending toward 9500. Measuring UN with five different progressively increasing accelerating voltages followed by using the modeling program xMAC suggests the actual MAC is approximately 2115. Additional MAC modifications were required to produce reasonable analytical results. Because of the inaccuracies of necessary MAC coefficients, UN analysis via scanning electron microscopy (SEM) is likely to produce inaccurate results. This is because SEM software does not typically allow the user to alter MACs. Tests have been performed to examine the feasibility of an electrochemical technique to liberate irradiated TRISO fuel from a SiC matrix without damaging the outer pyrolytic carbon layer of the fuel particle. The method is performed by electrochemically exposing the SiC to magnesium metal forming Mg2Si and C. Following exposure, the small SiC samples showed slight mass increases with no evidence of conversion to Mg2Si and C nor obvious degradation of the SiC samples.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Advance optical fiber probe for simultaneous measurements of solids holdup and particles velocity using simple calibration methods for gas-solid fluidization systems

We report advanced gas-solid optical fiber probe technique that can measure simultaneously solids velocity, solids concentration related quantity, and their time series fluctuations has been implemented with simple and new calibration methods for both solids holdup and particles velocity measurements in gas-solid spouted bed and gas-solid fluidized bed. The needed signal and data processing programs have been developed in our laboratory. New, simple, and reliable calibration methods and the related experimental setups have been established to convert the solids concentration related signal to solids holdup which is a meaningful hydrodynamic parameter and to determine the effective distance between the two tips of the probe for the solids velocity measurements. The new calibration methods have been employed to cover a wide range of particle sizes which usually used in gas-solid spouted beds and gas-solid fluidized beds. Selected results have demonstrated the appropriateness of the advanced optical fiber in measuring both solids holdup and particles velocity in the experimental setups of the gas-solid spouted and fluidized beds. The measurements have been compared against independent techniques of gamma ray computed tomography (CT) and radioactive particle tracking (RPT).

42 ENGINEERING↗

Particle velocity measurement within a free-falling particle curtain using microscopic shadow velocimetry

We report an optical method for particle velocity measurement that is suitable for the measurement of particle velocities within dense particle-laden flows with high spatial resolution. The technique is based on particle shadow velocimetry with the use of a long-distance microscopic lens for images collection. The narrow depth of field of the lens allows particles within the focal plane to have much higher pattern intensities than those outside it on the collected images. Data processing was then employed to remove particles from outside the focal plane based on the gradient of the signal and a threshold. Following this, particle velocity was calculated from two successive images in the usual way. The technique was successfully demonstrated in a free-falling particle curtain with volume fractions in the four-way coupling regime of near-spherical micro-particles falling under gravity. The method was successfully employed to measure the transverse velocity profile through the curtain, which is the first time that such a measurement has been performed. Other highly-fidelity experimental data, which is also well suited to model development and validation, include the particle mass flow rate, curtain thickness and opacity.

Han, Shipu (ORCID:0000000278545882)↗

Multiplicity and transverse momentum dependence of two- and four-particle correlations in pPb and PbPb collisions

Measurements of two- and four-particle angular correlations for charged particles emitted in pPb collisions are presented over a wide range in pseudorapidity and full azimuth. The data, corresponding to an integrated luminosity of approximately 31 inverse nanobarns, were collected during the 2013 LHC pPb run at a nucleon-nucleon center-of-mass energy of 5.02 TeV by the CMS experiment. The results are compared to 2.76 TeV semi-peripheral PbPb collision data, collected during the 2011 PbPb run, covering a similar range of particle multiplicities. The observed correlations are characterized by the near-side (abs(Delta(phi)~0) associated pair yields and the azimuthal anisotropy Fourier harmonics (v[n]). The second-order (v[2]) and third-order (v[3]) anisotropy harmonics are extracted using the two-particle azimuthal correlation technique. A four-particle correlation method is also applied to obtain the value of v[2] and further explore the multi-particle nature of the correlations. Both associated pair yields and anisotropy harmonics are studied as a function of particle multiplicity and transverse momentum. The associated pair yields, the four-particle v[2], and the v[3] become apparent at about the same multiplicity. A remarkable similarity in the v[3] signal as a function of multiplicity is observed between the pPb and PbPb systems. Predictions based on the color glass condensate and hydrodynamic models are compared to the experimental results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Preconcentrator with high volume chiller for high vapor pressure particle detection

Apparatus and method for collecting particles of both high and low vapor pressure target materials entrained in a large volume sample gas stream. Large volume active cooling provides a cold air supply which is mixed with the sample gas stream to reduce the vapor pressure of the particles. In embodiments, a chiller cools air from ambient conditions to 0-15.degree. C. with the volumetric flow rate of the cold air supply being at least equal to the volumetric flow rate of the sample gas stream. In further embodiments an adsorption media is heated in at least two stages, a first of which is below a threshold temperature at which decomposition products of the high vapor pressure particle are generated.

47 OTHER INSTRUMENTATION↗

Sublimation systems and associated methods

A system for vaporizing and sublimating a slurry comprising a fluid including solid particles therein. The system includes a first heat exchanger configured to receive the fluid including solid particles and vaporize the fluid and a second heat exchanger configured to receive the vaporized fluid and solid particles and sublimate the solid particles. A method for vaporizing and sublimating a fluid including solid particles therein is also disclosed. The method includes feeding the fluid including solid particles to a first heat exchanger, vaporizing the fluid, feeding the vaporized fluid and solid particles to a second heat exchanger and sublimating the solid particles. In some embodiments the fluid including solid particles is liquid natural gas or methane including solid carbon dioxide particles.

03 NATURAL GAS↗

Multimodal photon and neutron imaging devices with fast event-by-event multisampling readout and optimized particle type discrimination

A particle imaging method for distinguishing between types of incident particles, such as neutrons, photons, and alphas, and improving the position resolution of particle imaging devices with matrix readout. The method includes high frequency multisampling readout electronics that provides the sequences of multiple measurements for each detected event, resulting in recorded detailed waveform information describing the signals. Such detailed information is used to approximate each signal waveform with a parameterized function in which the extracted parameter sets determine the type of the incident particle in an optimized fashion. The detailed event-by-event multisampling information for each signal readout channel in the matrix readout of the radiation imaging devices improves and optimizes the position resolution for variable shapes of the signals. Such devices can be used in mixed radiation fields, creating a new class of multimodal photon and neutron imagers.

Degtiarenko, Pavel V.↗

Synthesis of nanocrystalline CeO{sub 2} particles by different emulsion methods

Cerium oxide nanoparticles were synthesized using three different methods of emulsion: (1) reversed micelle (RM); (2) emulsion liquid membrane (ELM); and (3) colloidal emulsion aphrons (CEAs). Ammonium cerium nitrate and polyoxyethylene-4-lauryl ether (PE4LE) were used as cerium and surfactant sources in this study. The powder was calcined at 500 Degree-Sign C to obtain CeO{sub 2}. The effect of the preparation procedure on the particle size, surface area, and the morphology of the prepared powders were investigated. The obtained powders are highly crystalline, and nearly spherical in shape. The average particle size and the specific surface area of the powders from the three methods were in the range of 4-10 nm and 5.32-145.73 m{sup 2}/g, respectively. The CeO{sub 2} powders synthesized by the CEAs are the smallest average particle size, and the highest surface area. Finally, the CeO{sub 2} prepared by the CEAs using different cerium sources and surfactant types were studied. It was found that the surface tensions of cerium solution and the type of surfactant affect the particle size of CeO{sub 2}. - Graphical Abstract: The emulsion droplet size distribution and the TEM images of CeO{sub 2} prepared by different methods: reversed micelle (RM), emulsion liquid membrane (ELM) and colloidal emulsion aphrons (CEAs). Highlights: Black-Right-Pointing-Pointer Nano-sized CeO{sub 2} was successfully prepared by three different emulsion methods. Black-Right-Pointing-Pointer The colloidal emulsion aphrons method producing CeO{sub 2} with the highest surface area. Black-Right-Pointing-Pointer The surface tensions of a cerium solution have slightly effect on the particle size. Black-Right-Pointing-Pointer The size control could be interpreted in terms of the adsorption of the surfactant.

36 MATERIALS SCIENCE↗

Systematic studies of elliptic flow measurements in Au + Au collisions at sqrt sNN = 200 GeV

We present inclusive charged hadron elliptic flow (v{sub 2}) measured over the pseudorapidity range |{eta}| < 0.35 in Au+Au collisions at {radical}s{sub NN} = 200 GeV. Results for v{sub 2} are presented over a broad range of transverse momentum (p{sub T} = 0.2-8.0 GeV/c) and centrality (0-60%). To study nonflow effects that are correlations other than collective flow, as well as the fluctuations of v{sub 2}, we compare two different analysis methods: (1) the event-plane method from two independent subdetectors at forward (|{eta}| = 3.1-3.9) and beam (|{eta}| > 6.5) pseudorapidities and (2) the two-particle cumulant method extracted using correlations between particles detected at midrapidity. The two event-plane results are consistent within systematic uncertainties over the measured p{sub T} and in centrality 0-40%. There is at most a 20% difference in the v{sub 2} between the two event-plane methods in peripheral (40-60%) collisions. The comparisons between the two-particle cumulant results and the standard event-plane measurements are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Massively-parallel Lagrangian particle code and applications

Massively-parallel, distributed-memory algorithms for the Lagrangian particle hydrodynamic method (Samulyak et al., 2018) have been developed, verified, and implemented. The key component of parallel algorithms is a particle management module that includes a parallel construction of octree databases, dynamic adaptation and refinement of octrees, and particle migration between parallel subdomains. The particle management module is based on the p4est (parallel forest of k-trees) library. The massively-parallel Lagrangian particle code has been applied to a variety of fundamental science and applied problems. A summary of Lagrangian particle code applications to the injection of impurities into thermonuclear fusion devices and to the simulation of supersonic hydrogen jets in support of laser-plasma wakefield acceleration research has also been presented.

97 MATHEMATICS AND COMPUTING↗

Applicability of discrete element method with spherical and clumped particles for constitutive study of granular materials

Discrete element method (DEM) has been intensively used to study the constitutive behaviour of granular materials. However, to what extent a real granular material can be reproduced by virtual DEM simulations remains unclear. This study attempts to answer this question by comparing DEM simulations with typical features of experimental granular materials. Three groups of models with spherical and clumped particles are investigated from four perspectives: (i) deviatoric stress and volumetric behaviour; (ii) critical state behaviour; (iii) stress-dilatancy relationship; and (iv) the evolution of principal stress ratio against axial strain. The results demonstrate that DEM with spherical or clumped particles is capable of qualitatively describing macroscopic deviatoric stress responses, volumetric behaviour, and critical state behaviour observed in experiments for granular materials. On the other hand, some qualitative deviations between experiments and the investigated DEM simulations are also observed, in terms of the stress-dilatancy behaviour and principal stress ratio against axial strain, which are proven to be critical for constitutive modelling. The results demonstrate that DEM with spherical or clumped particles may not necessarily fully capture experimental features of granular materials even from a qualitative perspective. It is thus encouraged to thoroughly validate DEM with experiments when developing constitutive models based on DEM observations.

58 GEOSCIENCES↗

Phase-coexistence simulations of fluid mixtures by the Markov Chain Monte Carlo method using single-particle models

We present a single-particle Lennard–Jones (L-J) model for CO{sub 2} and N{sub 2}. Simplified L-J models for other small polyatomic molecules can be obtained following the methodology described herein. The phase-coexistence diagrams of single-component systems computed using the proposed single-particle models for CO{sub 2} and N{sub 2} agree well with experimental data over a wide range of temperatures. These diagrams are computed using the Markov Chain Monte Carlo method based on the Gibbs-NVT ensemble. This good agreement validates the proposed simplified models. That is, with properly selected parameters, the single-particle models have similar accuracy in predicting gas-phase properties as more complex, state-of-the-art molecular models. To further test these single-particle models, three binary mixtures of CH{sub 4}, CO{sub 2} and N{sub 2} are studied using a Gibbs-NPT ensemble. These results are compared against experimental data over a wide range of pressures. The single-particle model has similar accuracy in the gas phase as traditional models although its deviation in the liquid phase is greater. Since the single-particle model reduces the particle number and avoids the time-consuming Ewald summation used to evaluate Coulomb interactions, the proposed model improves the computational efficiency significantly, particularly in the case of high liquid density where the acceptance rate of the particle-swap trial move increases. We compare, at constant temperature and pressure, the Gibbs-NPT and Gibbs-NVT ensembles to analyze their performance differences and results consistency. As theoretically predicted, the agreement between the simulations implies that Gibbs-NVT can be used to validate Gibbs-NPT predictions when experimental data is not available.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Triple-decker: Interfacing atomistic-mesoscopic-continuum flow regimes

Multiscale flow phenomena in microfluidic and biomedical applications require the use of heterogeneous modeling approaches. In this paper we present a hybrid method based on coupling the Molecular Dynamics (MD) method, the Dissipative Particle Dynamics (DPD) method, and the incompressible Navier-Stokes (NS) equations. MD, DPD, and NS are formulated in separate subdomains and are coupled via an overlapping region by communicating state information at the subdomain boundaries. Imposition of boundary conditions in the MD and DPD systems involves particle insertion and deletion, specular wall reflection and body force terms. The latter includes a boundary pressure force in order to minimize near-boundary density fluctuations, and an adaptive shear force which enforces the tangential velocity component of boundary conditions. The triple-decker algorithm is verified for prototype flows, including simple and multi-layer fluids (Couette, Poiseuille, and lid-driven cavity), using highly accurate reference solutions. A zero-thickness interface is also possible if it is aligned with the flow streamlines.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modeling and implementation of vertical excursion FFA in the Zgoubi ray-tracing code

Vertical Fixed Field Accelerators (vFFAs) feature complex and highly non-linear magnetic fields, which require simulation codes allowing step-wise particle tracking. Methods to model the 3D magnetic field of scaling vFFAs have been developed in the ray-tracing code Zgoubi. The field modeling and particle tracking methods include the field non-linearities, the fringe fields, and the field superposition of neighboring magnets. The procedure implements the vFFA analytical field expressions, allowing design studies and parameter optimizations using the Zgoubi built-in fit method. The vFFA procedure has been applied to a ten-fold symmetry ring with a triplet focusing structure designed to accelerate protons from 3 MeV to 12 MeV and studied under the ISIS-II proton driver prototype project. Results from particle tracking in externally generated 3D semi-analytical field maps and the developed vFFA analytical model are shown to be in excellent agreement.

43 PARTICLE ACCELERATORS↗