Search NASA⌕ Search

SEARCH · Search NASA

Results for “Profiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Modification of Edge Profiles, Edge Transport, and ELM Stability with Lithium in NSTX

We report results of an experiment in which lithium wall coatings were graduallyintroduced into NSTX, resulting in a gradual improvement in energy confinement, alterationof edge plasma profiles, and growing periods of ELM suppression. As a result of increasinglithium wall coatings, recycling and edge fueling were reduced, which relaxed the edgedensity profile gradients. In contrast, the edge Te profile was unaffected in the H-modepedestal steep gradient region at constant plasma stored energy; however, the region of steepTe gradients extended radially inward by several cm following lithium coatings.Consequently, the pressure profile width and pedestal height increased substantially, while theELM-free discharge peak pressure gradients were comparable to the pre-lithium ELMydischarge gradients. The measured edge profiles in discharges with and without lithium weresimulated with the SOLPS code, which indicated that both a reduction in recycling and a dropin the edge and SOL cross-field transport was required to match the post-lithium profiles.Edge stability calculations showed that the discharges with lithium coatings were farther fromthe low-n kink/peeling modes boundary than the pre-lithium discharges.

Maingi, Rajesh↗

Ion beam profiling system and related methods

An ion beam profiling system include a beam profiling element, an ion sensitive element electrically isolated from the beam profiling element, an ion source configured to emit an ion beam at the beam profiling element and the ion sensitive element, and a current measuring device coupled to the ion sensitive element. The beam profiling element includes a plate of material having two parallel major surfaces, a first slit aperture extending through the plate of material and having a first longitudinal length extending in a direction parallel to the two parallel major surfaces, and a second slit aperture extending through the plate of material and having a second longitudinal length extending in a direction parallel to the two parallel major surfaces, wherein the first longitudinal length of the first slit aperture is perpendicular to the second longitudinal length of the second slit aperture.

Taylor, Chase N.↗

Development of pseudo-random binary arrays for calibration of surface profile metrology tools

Optical Metrology tools, especially for short wavelength (EUV and X-Ray), must cover a wide range of spatial frequencies from the very low, which affects figure, to the important mid-spatial frequencies and the high spatial frequency range, which produces undesirable scattering. A major difficulty in using surface profilometers arises due to the unknown Point-Spread Function (PSF) of the instruments [1] that is responsible for distortion of the measured surface profile. Generally, the distortion due to the PSF is difficult to account because the PSF is a complex function that comes to the measurement via the convolution operation, while the measured profile is described with a real function. Accounting for instrumental PSF becomes significantly simpler if the result of measurement of a profile is presented in a spatial frequency domain as a Power Spectral Density (PSD) distribution [2]. For example, the measured PSD distributions provide a closed set of data necessary for three-dimensional calculations of scattering of light by the optical surfaces [3], [4]. The distortion of the surface PSD distribution due to the PSF can be modeled with the Modulation Transfer Function (MTF), which is defined over the spatial frequency bandwidth of the instrument [1], [2]. The measured PSD distribution can be presented as a product of the squared MTF and the ideal PSD distribution inherent for the System Under Test (SUT). Therefore, the instrumental MTF can be evaluated by comparing a measured PSD distribution of a known test surface with the corresponding ideal numerically simulated PSD. The square root of the ratio of the measured and simulated PSD distributions gives the MTF of the instrument. In previous work [5], [6] the instrumental MTF of a surface profiler was precisely measured using reference test surfaces based on Binary Pseudo-Random (BPR) gratings. Here, we present results of fabricating and using two-dimensional (2D) BPR arrays that allow for a direct 2D calibration of the instrumental MTF. BPR sequences are widely used in engineering and communication applications such as Global Position System, and wireless communication protocols. The ideal BPR pattern has a flat 'white noise' response over the entire range of spatial frequencies of interest. The BPR array used here is based on the Uniformly Redundant Array prescription [7] initially used for x-ray and gamma ray astronomy applications. The URA's superior imaging capability originates from the fact that its cyclical autocorrelation function very closely approximates a delta function, which produces a flat PSD. Three different size BPR array patterns were fabricated by electron beam lithography and ICP etching of silicon. The basic size unit was 200 nm, 400 nm, and 600 nm. Two different etch processes were used, CF{sub 4}/Ar and HBr, which resulted in undercut and vertical sidewall profiles, respectively. The 2D BPR arrays were used as standard test surfaces for MTF calibration of the MicroMap{trademark}-570 interferometric microscope using all available objectives. The HBr etched two-dimensional BPR arrays have proven to be a very effective calibration standard making possible direct calibration corrections without the need of additional calculation considerations, while departures from the ideal vertical sidewall require an additional correction term for the CF{sub 4}/Ar etched samples. [8] Initial surface roughness of low cost 'prime' wafers limits low magnification calibration but should not be a limitation if better polished samples are used.

36 MATERIALS SCIENCE↗

Bio-optical profiling floats as new observational tools for biogeochemical and ecosystem studies: Potential synergies with ocean color remote sensing

Profiling floats now represent a mature technology. In parallel with their emergence, the field of miniature, low power bio-optical and biogeochemical sensors is rapidly evolving. Over recent years, the bio-geochemical and bio-optical community has begun to benefit from the increase in observational capacities by developing profiling floats that allow the measurement of key biooptical variables and subsequent products of biogeochemical and ecosystem relevance like Chlorophyll a (Chla), optical backscattering or attenuation coefficients which are proxies of Particulate Organic Carbon (POC), Colored Dissolved Organic Matter (CDOM). Thanks to recent algorithmic improvements, new bio-optical variables such as backscattering coefficient or absorption by CDOM, at present can also be extracted from space observations of ocean color. In the future, an intensification of in situ measurements by bio-optical profiling floats would permit the elaboration of unique 3D/4D bio-optical climatologies, linking surface (remotely detected) properties to their vertical distribution (measured by autonomous platforms), with which key questions in the role of the ocean in climate could be addressed. In this context, the objective of the IOCCG (International Ocean Color Coordinating Group) BIO-Argo working group is to elaborate recommendations in view of a future use of bio-optical profiling floats as part of a network that would include a global array that could be 'Argo-relevant', and specific arrays that would have more focused objectives or regional targets. The overall network, realizing true multi-scale sustained observations of global marine biogeochemistry and biooptics, should satisfy the requirements for validation of ocean color remote sensing as well as the needs of a wider community investigating the impact of global change on biogeochemical cycles and ecosystems. Regarding the global profiling float array, the recommendation is that Chla as well as POC should be the key variables to be systematically measured. A first target would be to implement 20% of the Argo floats with these measurements within a five-year term. The yearly additional cost is estimated to 1.5 M$, including additional management structure in each of the two Global Data Assembly Centers.

54 ENVIRONMENTAL SCIENCES↗

Merging Fungal and Bacterial Community Profiles via an Internal Control

Integrated measurements of fungi and bacteria are critical to understand how interactions between these taxa drive key processes in ecosystems ranging from soils to animal guts. High-throughput amplicon sequencing is commonly used to census microbiomes, but the genetic markers targeted for fungi and bacteria (typically ribosomal regions) are domain-specific so profiling must be performed separately, obscuring relationships between these groups. To solve this problem, we developed a spike-in method with an internal control (IC) construct containing primer sites commonly used for bacterial and fungal taxonomic profiling. The internal control offers several advantages: estimation of absolute abundances, estimation of fungal to bacterial ratios (F:B), integration of bacterial and fungal profiles for holistic community analysis, and lower costs compared to other quantitation methods. To validate the IC as a scaling method, we compared IC-derived measures of F:B to measures from quantitative PCR (qPCR) using a commercial mock community (the ZymoBiomic Microbial Community DNA Standard II, containing two fungi and eight bacteria) and complex environmental samples. For both the mock community and the environmental samples, the IC produced F:B values that were statistically consistent with qPCR. Merging the environmental fungal and bacterial profiles based on the IC-derived F:B values revealed new relationships among samples in terms of community similarity. As a result, this IC method is the first spike-in method to employ a single construct for cross-domain amplicon sequencing, offering more reliable measurements.

59 BASIC BIOLOGICAL SCIENCES↗

Dynamic Vertical Profiles of Peat Porewater Chemistry in a Northern Peatland

We measured pH, cations, nutrients, and total organic carbon (TOC) over 3 years to examine weekly to monthly variability in porewater chemistry depth profiles (0–3.0 m) in an ombrotrophic bog in Minnesota, USA. We also compared temporal variation at one location to spatial variation in depth profiles at 16 locations across the bog. Most solutes exhibited large gradients with depth. pH increased by two units and calcium concentrations increased over 20 fold with depth, and may reflect peatland development from minerotrophic to ombrotrophic conditions. Ammonium concentrations increased almost 20 fold and TOC concentrations decreased by half with depth, and these patterns likely reflect mineralization of peat or decomposition of TOC. There was also considerable temporal variation in the porewater chemistry depth profiles. Ammonium, soluble reactive phosphorus, and potassium showed greater temporal variation in near-surface porewater, while pH, calcium, and TOC varied more at depth. This variation demonstrates that deep peat porewater chemistry is not static. Lastly, temporal variation in solute chemistry depth profiles was greater than spatial variation in several instances, especially in shallow porewaters. In conclusion, characterizing both temporal and spatial variability is necessary to ensure representative sampling in peatlands, especially when calculating solute pools and fluxes and parameterizing process-based models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simultaneous Observations of Surface Layer Profiles of Humidity, Temperature, and Wind Using Scanning Lidar Instruments

We demonstrate the combination of three Doppler lidars (DLs), a water vapor differential absorption lidar and a temperature rotational Raman lidar for the investigation of the interactions between the land-surface and the atmospheric boundary layer. This combination of scanning lidars was operated for the first time during the Land-Atmosphere Feedback Experiment at the Atmospheric Radiation Measurement program's Southern Great Plain site, Oklahoma, USA, in August 2017, and provided simultaneous surface layer profiles of horizontal wind, humidity and temperature. The horizontal wind profiles were determined using the dual-Doppler method with two DLs. The scans were performed above four towers providing atmospheric variables and fluxes. These combined lidar data allowed for the estimation of the friction velocity as well as the surface latent and sensible heat fluxes. For this purpose, profiles calculated with Monin-Obukhov similarity theory were fitted with the Levenberg-Marquardt nonlinear least squares curve-fitting method to the measured surface-layer lidar profiles. We present case studies of three 50-min periods to illustrate the new method. The measurements resulted in friction velocities of 0.31, 0.29, and 0.38 ms –1 , sensible surface heat fluxes of 312.1, 234.1, and 183.3 Wm –2 and latent surface heat fluxes of 251.8, 227.3, and 274.4 Wm –2 . These values were compared with the in-situ measurements of the towers. Considering the sampling differences and the error analyses, the results agree within 25.1%, 42.5%, and 28.8%, respectively, demonstrating that this synergy of scanning active remote sensing systems can be used to derive surface fluxes with reasonable accuracy.

54 ENVIRONMENTAL SCIENCES↗

Production of electron cyclotron resonance plasma by using multifrequencies microwaves and active beam profile control on a large bore electron cyclotron resonance ion source with permanent magnets

A new concept on magnetic field with all magnets on plasma production and confinement has been proposed to enhance efficiency of an electron cyclotron resonance (ECR) plasma for broad and dense ion beam source under the low pressure. The magnetic field configuration is constructed by a pair of magnets assembly, i.e., comb-shaped magnet which cylindrically surrounds the plasma chamber. The resonance zones corresponding to the fundamental ECR for 2.45 GHz and 11-13 GHz frequencies are constructed at different positions. The profiles of the plasma parameters in the ECR ion source are different from each frequency of microwave. Large bore extractor is set at the opposite side against the microwave feeds. It is found that differences of their profiles also appear at those of ion beam profiles. We conducted to launch simultaneously multiplex frequencies microwaves controlled individually, and tried to control the profiles of the plasma parameters and then those of extracted ion beam.

43 PARTICLE ACCELERATORS↗

Characterization of the Li beam probe with a beam profile monitor on JET

The lithium beam probe (LBP) is widely used for measurements of the electron density in the edge plasma of magnetically confined fusion experiments. The quality of LBP data strongly depends on the stability and profile shape of the beam. The main beam parameters are as follows: beam energy, beam intensity, beam profile, beam divergence, and the neutralization efficiency. For improved monitoring of the beam parameters, a beam profile monitor (BPM) from the National Electrostatics Corporation (NEC) has been installed in the Li beam line at JET. In the NEC BPM, a single grounded wire formed into a 45 deg. segment of a helix is rotated by a motor about the axis of the helix. During each full revolution, the wire sweeps twice across the beam to give X and Y profiles. In this paper, we will describe the properties of the JET Li beam as measured with the BPM and demonstrate that it facilitates rapid optimization of the gun performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatially resolved measurements of electron cyclotron resonance ion source beam profile characteristics

Simulations predict that the concentric rings and the triangular structures in the profiles of strongly focused ion beams that are found in different experiments should be dominated by ion species with the same or at least similar m/q-ratio. To verify these theoretical predictions we have tuned our ECR ion source to deliver a beam consisting of multiple ion species whose particular m/q-depending focusing ranges from weakly focused to overfocused. We then recorded spatially resolved charge-state distributions of the beam profile at characteristic positions in the plane perpendicular to the beam line. The results validate theoretical predictions and are summarized in this paper. To achieve the required beam profile characteristics we moved the extraction along the beam line to achieve stronger focusing than by only changing the extraction voltage. To fit the regions of interest of the beam profile into the transmission area of the sector magnet, we steered the beam by moving the extraction in the plane perpendicular to the beam axis. The results of both investigations, beam focusing and beam steering by using a 3D-movable extraction, are also reported in this paper. A brief overview of the new beam monitor extensively used during these measurements, the Faraday cup array, is also given.

43 PARTICLE ACCELERATORS↗

Influence of the Edge Plasma Profile and Parameters on the Coupling of an ICRH Antenna. Application to ITER

The coupling to the fast wave of an ICRH antenna is principally determined by its distance to an optimum plasma density correlated to the cutoff one and by the density gradient between this optimum density and the bulk plasma. This explains the differences in coupling for the various heating and current drive phasings as predicted for different plasma edge profiles considered for ITER. For a given electron density edge profile the ion mix, the steady magnetic field and the frequency have also a significant effect on the coupling performances. These quantities affect the coupling mainly by influencing the position of the optimum density in the profile. A marked perturbation of the coupling leading to a large edge power deposition can occur when the Alfven resonance lies in the edge profile. The results are applied to different ICRF scenarios considered for ITER at full and half toroidal field.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Runaway electron plateau current profile reconstruction from synchrotron imaging and Ar-II line polarization angle measurements in DIII-D

Abstract Current profile reconstructions are obtained for high current ( I p ≃ 550 kA) post-disruption runaway electron (RE) plateau plasmas in DIII-D. Two novel methods of measuring the RE current profile in high-current RE plateaus are introduced and compared: localization of the q = 2 rational surface using visible synchrotron emission (SE) imaging and the measurement of the polarization angle of line-integrated Ar-II line emission. The two methods are found to be consistent with each other within the data uncertainties. Different simulations of the RE current profile are compared with the measurements: the toroidal fluid RE model is found to best fit the data, within the measurement uncertainties. In addition to introducing two novel methods to measure the RE current profile and validating present simulation capabilities, this work demonstrates that instabilities can grow at q = 2 and q = 1 surfaces without necessarily causing a RE final loss instability. Numerical simulations are also presented to elucidate the role of these instabilities on synchrotron emission.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stellar and weak lensing profiles of massive galaxies in the Hyper-Suprime Cam survey and in hydrodynamic simulations

ABSTRACT We perform a consistent comparison of the mass and mass profiles of massive (M⋆ > 1011.4 M⊙) central galaxies at z ∼ 0.4 from deep Hyper Suprime-Cam (HSC) observations and from the Illustris, TNG100, and Ponos simulations. Weak lensing measurements from HSC enable measurements at fixed halo mass and provide constraints on the strength and impact of feedback at different halo mass scales. We compare the stellar mass function (SMF) and the Stellar-to-Halo Mass Relation (SHMR) at various radii and show that the radius at which the comparison is performed is important. In general, Illustris and TNG100 display steeper values of α where $M_{\star } \propto M_{\rm vir}^{\alpha }$. These differences are more pronounced for Illustris than for TNG100 and in the inner rather than outer regions of galaxies. Differences in the inner regions may suggest that TNG100 is too efficient at quenching in situ star formation at Mvir ≃ 1013 M⊙ but not efficient enough at Mvir ≃ 1014 M⊙. The outer stellar masses are in excellent agreement with our observations at Mvir ≃ 1013 M⊙, but both Illustris and TNG100 display excess outer mass as Mvir ≃ 1014 M⊙ (by ∼0.25 and ∼0.12 dex, respectively). We argue that reducing stellar growth at early times in $M_\star \sim 10^{9-10} \, \mathrm{M}_{\odot }$ galaxies would help to prevent excess ex-situ growth at this mass scale. The Ponos simulations do not implement AGN feedback and display an excess mass of ∼0.5 dex at r < 30 kpc compared to HSC which is indicative of overcooling and excess star formation in the central regions. The comparison of the inner profiles of Ponos and HSC suggests that the physical scale over which the central AGN limits star formation is r ≲ 20 kpc. Joint comparisons between weak lensing and galaxy stellar profiles are a direct test of whether simulations build and deposit galaxy mass in the correct dark matter haloes and thereby provide powerful constraints on the physics of feedback and galaxy growth. Our galaxy and weak lensing profiles are publicly available to facilitate comparisons with other simulations.

79 ASTRONOMY AND ASTROPHYSICS↗

Profile etching for prefiguring X-ray mirrors

A method to pre-shape mirror substrates through etching with a broad-beam ion source and a contoured mask is presented. A 100 mm-long elliptical cylinder substrate was obtained from a super-polished flat Si substrate with a 48 nm root-mean-square (r.m.s.) figure error and a 1.5 Å r.m.s. roughness after one profile-etching process at a beam voltage of 600 V without iteration. A follow-up profile coating can be used to achieve a final mirror. Profile etching and profile coating combined provide an economic way to make X-ray optics, such as nested Kirkpatrick–Baez mirrors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Data-Driven Modeling of High-Resolution Residential Load Profiles Using Low-Resolution Smart Meter Measurements

Accurate and high-resolution residential load profiles are essential for power system modeling, demand response planning, and effective grid operation. As the energy sector moves towards a more actively managed distribution system, the ability to understand residential energy consumption at a minute-by-minute scale becomes increasingly critical. High-resolution load profiles provide key insights into demand patterns and user behavior, enabling grid operators to design more effective energy solutions; however, residential load measurements in the field are typically recorded at low resolutions, such as 15-60 minutes, which makes it hard to study the characteristics of different residential customers. This paper addresses these challenges by introducing a data-driven approach to generate realistic, high-resolution residential load profiles based on lowre-solution measurements and weather information. The proposed method retains the key features of the actual residential load measurements while offering appliance-level energy consumption details for each residential building. The results demonstrate the effectiveness of the proposed load profile generator, proving its capability to support utilities in optimizing residential energy management and ensuring a more reliable and resilient grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Concentration Profiles in Screened Wells Under Static and Pumped Conditions

Purge and pump sampling results from screened wells can be affected by the processes of concentration averaging and contaminant redistribution by wellbore flow. The effects due to concentration averaging were assessed in a screened well at the Hanford Site by investigating the vertical profile of a technetium-99 plume in the aquifer. Nitrate is a co-contaminant with technetium-99 and the dominant anion in the aquifer water, which enabled measurements of specific conductance to be used as an analog for technetium-99. Time-series measurements were collected during purging from three specific conductance probes installed in the well at 1.2 m, 3.1 m, and 4.9 m below the water table in a 7.7 m deep screened well. The vertical contaminant profile in the aquifer was calculated using a wellbore flow and mixing model. The highest concentrations occurred primarily in the upper part of the screened interval, and the purge and pump sample results were 41% to 58% of the calculated peak concentration in the aquifer due to concentration averaging. Plume stratification became more pronounced as pumping continued. Extended pumping may have reversed the effect of contaminant redistribution by wellbore flow. It was also found that the vertical profile of contamination in the wellbore under static (i.e., non-pumping conditions) was not representative of the profile in the aquifer. Thus, passive or micro-purge sampling techniques, which essentially sample the wellbore water, will not necessarily yield results representative of the aquifer.

54 ENVIRONMENTAL SCIENCES↗

TH-C-18A-04: Validation of Dosimetric Measurement of CT Radiation Profile Width

Purpose: The ACR now requires that the CT radiation profile width be measured at all clinically used collimations. We developed a method for measuring the profile width using dosimetry alone to allow a faster and simpler measurement of beam widths. Methods: A pencil ionization chamber is used to take two dose-length product measurements in air for a wide collimation. One of these is taken with a 1cm tungsten mask on the pencil chamber. The difference between these measurements is the calibration factor, or the DLP in air per unit length. By dividing the doselength product for any given collimation by this factor, we can rapidly determine the beam profile width.We measured the beam width for all available detector configurations and focal spot sizes on three different CT scanners from two different manufacturers. The measurements were done using film, CR cassette, and the present dosimetric method. Results: The beam widths measured dosimetrically are approximately 2% wider than those measured using film or computed radiography; this difference is believed due to off-focus or scattered radiation. After correcting for this, the dosimetric beam widths match the film and CR widths with an RMS difference of approximately 0.2mm. The measured beam widths are largely insensitive to errors in positioning of the mask, or to tilt errors in the pencil chamber. Conclusion: Using the present method, radiation profile widths can be measured quickly, with an accuracy better than 1mm.

07 ISOTOPE AND RADIATION SOURCES↗

An investigation into factors affecting the precision of CT radiation dose profile width measurements using radiochromic films

Purpose: To investigate the impact of x-ray beam energy, exposure intensity, and flat-bed scanner uniformity and spatial resolution on the precision of computed tomography (CT) beam width measurements using Gafchromic XR-QA2 film and an off-the-shelf document scanner. Methods: Small strips of Gafchromic film were placed at isocenter in a CT scanner and exposed at various x-ray beam energies (80–140 kVp), exposure levels (50–400 mA s), and nominal beam widths (1.25, 5, and 10 mm). The films were scanned in reflection mode on a Ricoh MP3501 flat-bed document scanner using several spatial resolution settings (100 to 400 dpi) and at different locations on the scanner bed. Reflection measurements were captured in digital image files and radiation dose profiles generated by converting the image pixel values to air kerma through film calibration. Beam widths were characterized by full width at half maximum (FWHM) and full width at tenth maximum (FWTM) of dose profiles. Dependences of these parameters on the above factors were quantified in percentage change from the baselines. Results: The uncertainties in both FWHM and FWTM caused by varying beam energy, exposure level, and scanner uniformity were all within 4.5% and 7.6%, respectively. Increasing scanner spatial resolution significantly increased the uncertainty in both FWHM and FWTM, with FWTM affected by almost 8 times more than FWHM (48.7% vs 6.5%). When uncalibrated dose profiles were used, FWHM and FWTM were over-estimated by 11.6% and 7.6%, respectively. Narrower beam width appeared more sensitive to the film calibration than the wider ones (R{sup 2} = 0.68 and 0.85 for FWHM and FWTM, respectively). The global and maximum local background variations of the document scanner were 1.2%. The intrinsic film nonuniformity for an unexposed film was 0.3%. Conclusions: Measurement of CT beam widths using Gafchromic XR-QA2 films is robust against x-ray energy, exposure level, and scanner uniformity. With proper film calibration and scanner resolution setting, it can provide adequate precision for meeting ACR and manufacturer’s tolerances for the measurement of CT dose profiles.

60 APPLIED LIFE SCIENCES↗